WORCESTER 24 CDI OF LPG

GLOBALLY REPLACED

Next: &20, *

RE-IGNITE DELAY

BOILER ON/OFF SWITCH ON

Next: &nff, !f169

OVERRUN OPERATION

BOILER ON/OFF SWITCH ON

Next: &1, !f168

SPILLAGE CHECK

Next: &2, !f167

CH MODULATION

{ISOLATEMAINSPOWER}<

Next: &3, f164

EXCESSIVE SYSTEM PRESSURE RISE

BOILER ON/OFF SWITCH ON
CH TEMPERATURE SELECTOR TO MAXIMUM
ROOM THERMOSTAT (IF FITTED) CALLING

Next: &290, !f163

DHW MODULATION

{ISOLATEMAINSPOWER}<

Next: &5, f146

GAS VALVE SOUNDNESS

Next: &251, !f108

AUTOMATIC FROST PROTECTION

CH TEMPERATURE SELECTOR TO OFF
DHW TEMPERATURE SELECTOR TO MINIMUM
BOILER ON/OFF SWITCH ON

Next: &9, f105

CH BURNER IGNITES

{ISOLATEMAINSPOWER}<

Next: &10, ?95, ?97

DHW HIGH FLAME

{ISOLATEMAINSPOWER}<

Next: &11, f315

DHW LOW FLAME

{ISOLATEMAINSPOWER}<

Next: &12, f495

DHW BURNER IGNITES

{ISOLATEMAINSPOWER}
ATTACH U-GAUGE TO GAS VALVE OUTLET PRESSURE TEST POINT

Next: &201, ?50, ?52, ?54, ?56

DHW PUMP RUNS

Next: &15, f33

DHW DEMAND

{ISOLATEMAINSPOWER}
REMOVE PLASTIC COVER FROM DIVERTER VALVE MICROSWITCH

Next: &16, f30

DHW FLOW RATE

Next: &17, f462

SYSTEM CHECKS

Next: &346, !f22

WORCESTER 24 CDI OF LPG

Next: &19, !f21

DHW OPERATION

DHW TEMPERATURE SELECTOR TO MAXIMUM

Next: &7, ?252, ?254, ?256, ?327

CENTRAL HEATING OPERATION

BOILER ON/OFF SWITCH ON
ROOM THERMOSTAT (IF FITTED) CALLING

Next: &4, ?291, ?293, ?458

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &348, !f347

FAULT CODES

Next: &18, !f349

FAIL POINT A

OUTSIDE MODEL

Next: &nff, f351

FAIL POINT B

OUTSIDE MODEL

Next: &nff, f357

FAIL POINT C

OUTSIDE MODEL

Next: &nff, f363

FAIL POINT D

OUTSIDE MODEL

Next: &nff, f367

FAIL POINT E

OUTSIDE MODEL

Next: &nff, f375

FAIL POINT F

OUTSIDE MODEL

Next: &nff, f387

FAIL POINT G

OUTSIDE MODEL

Next: &nff, f393

FAIL POINT H - LINK TO DHW BURNER IGNITES

OUTSIDE MODEL

Next: &nff, !f434

FAIL POINT I

OUTSIDE MODEL

Next: &nff, f529

FAIL POINT J

OUTSIDE MODEL

Next: &nff, f442

FAIL POINT K

OUTSIDE MODEL

Next: &nff, f446

FUSE INVESTIGATION TREE

OUTSIDE MODEL

Next: &nff, f522

PRIMARY SENSOR (AUTO FROST)

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

GAS VALVE SOUNDNESS

GAS VALVE

Next: End

DHW MODULATION

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

EXPANSION VESSEL

EXPANSION VESSEL 10 LITRES

Next: End

PRIMARY SENSOR (CH MODULATION)

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

FLUE CHECK

FLUE

Next: End

PCB (OVERRUN FUNCTION)

PCB (OVERRUN FUNCTION)

Next: End

PCB (RE-IGNITION DELAY)

PCB (RE-IGNITION DELAY)

Next: End

PRIMARY SENSOR (CH HIGH FLAME)

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

GAS PRESSURE PRESENT, NO SPARKING

SPARK ELECTRODE ASSEMBLY

Next: End

SPARK ELECTRODE LEADS

HARNESS ASSEMBLY - IGNITION

Next: End

GAS PRESSURE PRESENT, NO SPARKING

HARNESS - FLUE GAS SUPERVISOR

Next: End

BURNER NOT ESTABLISHING

GAS INLET PRESSURE

Next: End

MINIMUM GAS PRESSURE

GAS VALVE

Next: End

ELECTRICAL CHECKS

ELECTRICAL CHECKS

Next: End

SYSTEM CHECKS

SYSTEM CHECKS

Next: End

DHW NOISY

HEAT EXCHANGER - GAS TO WATER

Next: End

DHW NOISY

PUMP

Next: End

DHW RUNS HOT AND COLD DHW MODULATION

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

DHW HOT AND COLD

HEAT EXCHANGER - GAS TO WATER

Next: End

DHW RUNS HOT AND COLD

PUMP

Next: End

CH NOISY

PUMP

Next: End

BOILER NOISY

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

CH OP NOISY

HEAT EXCHANGER - GAS TO WATER

Next: End

RADS DO NOT HEAT

ISOLATING VALVE 22MM

Next: End

RADS DO NOT HEAT

PUMP

Next: End

CH RADS COLD

DIVERTER VALVE ASSEMBLY

Next: End

DIVERTER VALVE (DIAPHRAGM)

DIVERTER VALVE (DIAPHRAGM)

Next: End

DHW NOISY

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

DHW HIGH FLAME

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

DHW HIGH FLAME

GAS INLET PRESSURE

Next: End

DHW COOL

PUMP

Next: End

DHW TOO COOL

HEAT EXCHANGER - GAS TO WATER

Next: End

DHW COOL RADS COOL

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

DHW COOL RADS COOL

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

TYPE OF DIAGNOSTIC PROCEDURE

Z REDIRECT

Next: End

FAULT CODES

Z REDIRECT

Next: End

FAIL POINT A

FUSE F1 (2 AMP)

Next: End

FAIL POINT A

Next: End

FAIL POINT B

FUSE F2 (1.25 AMP)

Next: End

FAIL POINT B

TRANSFORMER - JUNKER

Next: End

FAIL POINT C

PCB

Next: End

FAIL POINT D

Next: End

FAIL POINT E

DIVERTER VALVE (DIAPHRAGM)

Next: End

FAIL POINT E

DIVERTER VALVE (MICROSWITCH)

Next: End

FAIL POINT F

FROST PROTECTION

Next: End

FAIL POINT F

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

FAIL POINT G

GAS INLET PRESSURE

Next: End

FAIL POINT G - BOSCH GV

GAS VALVE

Next: End

FAIL POINT G - DUNGS GV

GAS VALVE

Next: End

FAIL POINT G

PCB ADJUSTMENT

Next: End

FAIL POINT G

HEAT EXCHANGER - GAS TO WATER

Next: End

FAIL POINT G

PLATE HEAT EXCHANGER

Next: End

FAIL POINT G

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

FAIL POINT H

Z REDIRECT

Next: End

TRANSFORMER

TRANSFORMER - JUNKER

Next: End

FAIL POINT K

Z REDIRECT

Next: End

FAIL POINT J

HARNESS - FLUE GAS SUPERVISOR

Next: End

CH OPERATION SHUTTING DOWN EARLY

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

DIVERTER VALVE (DHW FLOW ADJUSTER)

DIVERTER VALVE (DHW FLOW ADJUSTER)

Next: End

DHW INLET FILTER

FILTER STAINLESS STEEL - WATER INTER ALBION

Next: End

FLOW RESTRICTOR

FLOW REGULATOR

Next: End

DHW FLOW RATE

MAINS WATER SUPPLY

Next: End

DHW PUMP RUNS

DIVERTER VALVE (MICROSWITCH)

Next: End

DHW BURNER ESTABLISHES - LEAD DAMAGED

PROBE - FLAME SENSE C/W LEAD

Next: End

FLAME SENSE ELECTRODE

HARNESS MAIN

Next: End

HIGH FLAME - BOSCH GV

GAS VALVE

Next: End

HIGH FLAME - DUNGS GV

GAS VALVE

Next: End

DHW LOW FLAME

GAS INLET PRESSURE

Next: End

DHW LOW FLAME - BOSCH GV

GAS VALVE

Next: End

DHW LOW FLAME - DUNGS GV

GAS VALVE

Next: End

DHW PUMP RUNS

FUSE F2 (1.25 AMP)

Next: End

DHW PUMP RUNS

FUSE F1 (2 AMP)

Next: End

DHW PUMP RUNS

MAINS FUSE

Next: End

DHW BURNER IGNITES

GAS INLET PRESSURE

Next: End

FUSE INVESTIGATION

PUMP

Next: End

FUSE INVESTIGATION - MAIN

GAS VALVE

Next: End

FUSE INVESTIGATION - MODUREG

GAS VALVE

Next: End

FAIL POINT I

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

FAIL POINT I

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

FAULT CODE G

THERMOSTAT - OVERHEAT

Next: End

GAS PRESSURE AND SPARKING PRESENT BUT NO IGNITION

HARNESS - FLUE GAS SUPERVISOR

Next: End

GAS PRESSURE AND SPARKING PRESENT BUT NO IGNITION

SPARK ELECTRODE ASSEMBLY

Next: End

OVERHEAT THERMOSTAT

THERMOSTAT - OVERHEAT

Next: End

NO GAS PRESENT, NO SPARKING PRESENT

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

NO GAS PRESSURE, NO SPARKING PRESENT

KIT - THERMISTOR SENSOR - PRIMARY/DOMESTIC

Next: End

NO GAS PRESENT, NO SPARKING PRESENT

DIVERTER VALVE (MICROSWITCH)

Next: End

NO GAS PRESSURE, NO SPARKING PRESENT

HARNESS - FLUE GAS SUPERVISOR

Next: End

MAIN GAS VALVE VOLTAGE

HARNESS - FLUE GAS SUPERVISOR

Next: End

PCB (AUTO FROST)

PCB (AUTO FROST)

Next: End

DHW MODULATION

PCB

Next: End

DHW BURNER IGNITES

PCB (24 VOLTS SUPPLY)

Next: End

PCB (IGNITION TRANSFORMER)

PCB (IGNITION TRANSFORMER)

Next: End

DIVERTER VALVE

DIVERTER VALVE ASSEMBLY

Next: End

DHW OPERATION NOISY

PLATE HEAT EXCHANGER

Next: End

DHW OPERATION HOT AND COLD

PLATE HEAT EXCHANGER

Next: End

CH OP NOISY

Next: End

RADS DO NOT HEAT

Next: End

DIVERTER VALVE (SPINDLE)

DIVERTER VALVE (SPINDLE)

Next: End

DHW HIGH FLAME

PCB (24 VOLTS SUPPLY)

Next: End

DHW COOL RADIATORS COOL

PLATE HEAT EXCHANGER

Next: End

DHW TOO COOL

PCB

Next: End

DHW TOO COOL RADS COLD

INJECTOR - MAIN BURNER - LPG

Next: End

DHW TOO COOL RADS COLD

BURNER - AEROMATIC

Next: End

FAIL POINT A

PCB

Next: End

FAIL POINT B

PCB

Next: End

FAIL POINT C

Z REDIRECT

Next: End

FAIL POINT D

Z REDIRECT

Next: End

FAIL POINT E

DIVERTER VALVE (SPINDLE)

Next: End

FAIL POINT E

PCB

Next: End

FAIL POINT E

Z REDIRECT

Next: End

FAIL POINT F

PCB

Next: End

FAIL POINT G

PRESSURE GAUGE

Next: End

FAIL POINT G

SYSTEM PRESSURE

Next: End

FAIL POINT G - BOSCH GV

GAS VALVE ADJUSTMENT

Next: End

FAIL POINT G - DUNGS GV

GAS VALVE ADJUSTMENT

Next: End

FAIL POINT G

Next: End

FAIL POINT G

THERMOSTAT - OVERHEAT

Next: End

NO FAULT FOUND

OVERHEAT

Next: End

FAIL POINT J

PCB

Next: End

FAIL POINT K

PCB

Next: End

DHW PUMP RUNS

PCB

Next: End

PUMP

PUMP

Next: End

DHW FLOW RATE

PLATE HEAT EXCHANGER

Next: End

PCB (PUMP RELAY)

PCB (PUMP RELAY)

Next: End

HIGH FLAMED - BOSCH GV

GAS VALVE ADJUSTMENT

Next: End

HIGH FLAMED - DUNGS GV

GAS VALVE ADJUSTMENT

Next: End

DHW LOW FLAME - BOSCH GV

GAS VALVE ADJUSTMENT

Next: End

DHW LOW FLAME - DUNGS GV

GAS VALVE ADJUSTMENT

Next: End

DHW PUMP RUNS - F2

Z REDIRECT

Next: End

DHW PUMP RUNS - F1

Z REDIRECT

Next: End

ON / OFF SWITCH

PCB

Next: End

DHW PUMP RUNS

Next: End

DHW PUMP RUNS - MAINS

Z REDIRECT

Next: End

SPARKING BUT NO GAS PRESSURE

GAS VALVE

Next: End

FUSE INVESTIGATION

PCB - FUSE INVESTIGATION

Next: End

FAIL POINT I - PRIMARY SENSOR

HARNESS MAIN

Next: End

FAIL POINT I

PCB

Next: End

FAIL POINT I - DHW SENSOR

HARNESS MAIN

Next: End

BURNER INJECTOR

INJECTOR - MAIN BURNER - LPG

Next: End

PCB (LOCKOUT RESET STATUS)

PCB (LOCKOUT RESET STATUS)

Next: End

BURNER IGNITES AT HIGH FLAME

DIVERTER VALVE (MICROSWITCH)

Next: End

DHW NOISY

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p266

DHW RUNS HOT AND COLD

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p271

DHW COOL, RADIATORS WARM

CHARACTERISTIC TEST FROM DHW OPERATION

Next: !p257

BOILER REACHES TEMPERATURE, RADS DO NOT HEAT

CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION

Next: p292

BOILER NOISY

CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION

Next: p294

DHW TOO COOL, RADIATORS COLD

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p329

BURNER INJECTOR BLOCKED OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER AND INJECTOR

Next: !p343

BURNER BLOCKED OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER AND INJECTOR

Next: !p345

PRESSURE READS CORRECTLY BUT DOES NOT INCREASE

CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM

Next: !p396

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM

Next: !p398

RETURNS TO OVERHEAT FAULT CODE BEFORE 82°C

CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE

Next: !p426

FLOW TEMPERATURE ABOVE 88°C AND BOILER DOES NOT SHUT DOWN

CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE

Next: p428

SYSTEM BEGINS TO HEAT BUT BOILER SHUTS DOWN BEFORE REACHING TEMPERATURE

CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION

Next: p459

GAS PRESSURE PRESENT, NO SPARKING

CHARACTERISTIC TEST FROM DHW BURNER IGNITES

Next: p187

GAS PRESSURE AND SPARKING PRESENT BUT NO IGNITION

CHARACTERISTIC TEST FROM DHW BURNER IGNITES

Next: p53

NO GAS PRESSURE, NO SPARKING PRESENT

CHARACTERISTIC TEST FROM DHW BURNER IGNITES

Next: p55

SPARKING BUT NO GAS PRESSURE

CHARACTERISTIC TEST FROM DHW BURNER IGNITES

Next: p57

BURNER IGNITES AT HIGH FLAME

CHARACTERISTIC TEST FROM CH BURNER IGNITES

Next: !p96

BURNER DOES NOT IGNITE OR IGNITES BUT DOES NOT RAMP UP

CHARACTERISTIC TEST FROM CH BURNER IGNITES

Next: p98

PRIMARY SENSOR (AUTO FROST)

{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM SENSOR

Next: !p107, !f106

DHW SENSOR MODULATION RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT YELLOW WIRES FROM DHW SENSOR

Next: !p148, !f147

PRIMARY SENSOR (CH MODULATION)

CH TEMPERATURE SELECTOR TO MAXIMUM

Next: !p166, !f165

PRESSURE GAS INLET

{ISOLATEMAINSPOWER}<

Next: p203, !f204

DHW SENSOR MODULATION RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT YELLOW WIRES FROM DHW SENSOR

Next: !p275, !f276

DIVERTER VALVE DIAPHRAGM

{ISOLATEMAINSPOWER}
WATER OFF
DRAIN AND DISCHARGE BOILER

Next: !p32, !f31

PRESSURE GAS INLET

{ISOLATEMAINSPOWER}<

Next: p321, !f326

DHW SENSOR (HIGH FLAME)

{ISOLATEMAINSPOWER}
DISCONNECT YELLOW WIRES FROM DHW SENSOR
ENSURE DHW IS COOL

Next: !p324, !f325

ON/OFF SWITCH VOLTAGE (OUTPUT)

BOILER ON/OFF SWITCH ON

Next: p35, f507

DIFFERENTIAL PRIMARY HEAT EXCHANGER

{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS INDICATED

Next: !p334, !f335

FUSE F1 (2 AMP) (FAULT CODE)

{ISOLATEMAINSPOWER}
REMOVE FUSE F1 FROM PCB

Next: p352, !f353

FUSE F2 (1.25 AMP) (FAULT CODE)

{ISOLATEMAINSPOWER}
REMOVE FUSE F2 FROM PCB

Next: p358, !f359

INFORMATION FAIL POINT C

Next: !p364, !f365

ROOM THERMOSTAT/EXTERNAL CONTROLS RESISTANCE

{ISOLATEMAINSPOWER}
ROOM THERMOSTAT (IF FITTED) CALLING

Next: !p370, !f371

DHW DEMAND

{ISOLATEMAINSPOWER}
REMOVE PLASTIC COVER FROM DIVERTER VALVE MICROSWITCH

Next: p378, f379

DIVERTER VALVE DIAPHRAGM

{ISOLATEMAINSPOWER}
WATER OFF
DRAIN AND DISCHARGE BOILER

Next: !p380, !f381

TEMPERATURE AMBIENT

{ISOLATEMAINSPOWER}

Next: p388, !f389

INSPECTION PRESSURE SYSTEM

Next: p538, ?395, ?397

FUSE F2 (1.25 AMP)

{ISOLATEMAINSPOWER}
REMOVE FUSE F2 FROM PCB

Next: p43, f504

PUMP VOLTAGE

{ISOLATEMAINSPOWER}

Next: !p401, !f402

PRESSURE GAS INLET

{ISOLATEMAINSPOWER}<

Next: p407, !f408

ADJUSTMENT PRESSURE MAX AND MIN (BOSCH)

{ISOLATEMAINSPOWER}<

Next: !p411, !f412

DIFFERENTIAL PLATE HEAT EX

{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS INDICATED

Next: !p419, !f420

FLUE SPILLAGE SENSOR (FAULT CODE)

{ISOLATEMAINSPOWER}<

Next: !p443, !f449

INFORMATION FAIL POINT K

{ISOLATEMAINSPOWER}<

Next: !p447, !f448

DIVERTER VALVE MICROSWITCH RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: !p49, !f48

ADJUSTMENT PRESSURE MAX AND MIN (BOSCH)

{ISOLATEMAINSPOWER}<

Next: !p491, !f492

PRESSURE GAS INLET

{ISOLATEMAINSPOWER}<

Next: p496, !f497

ADJUSTMENT PRESSURE MAX AND MIN (BOSCH)

{ISOLATEMAINSPOWER}<

Next: !p500, !f501

FUSE FURTHER INVESTIGATION

Next: !p505, !f506

FUSE F1 (2 AMP)

{ISOLATEMAINSPOWER}
REMOVE FUSE F1 FROM PCB

Next: p508, f509

FUSE FURTHER INVESTIGATION

Next: !p510, !f511

RESISTANCE MAINS FUSE

{ISOLATEMAINSPOWER}
REMOVE THE FUSE FROM THE FUSED SPUR

Next: !p514, f515

FUSE FURTHER INVESTIGATION

Next: !p516, !f517

RESISTANCE PUMP AND HARNESS (FUSE INVESTIGATION)

{ISOLATEMAINSPOWER}
DISCONNECT PLUG ST15 FROM THE PCB

Next: p523, !f524

RESISTANCE PRIMARY SENSOR AT PCB (FAULT CODE)

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: p530, f531

PRIMARY SENSOR FAULT CODE

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH TEMPERATURE SENSOR

Next: !p532, !f533

DHW SENSOR (CALLING)

{ISOLATEMAINSPOWER}
DISCONNECT YELLOW WIRES FROM DHW SENSOR
ENSURE DHW IS COOL

Next: !p536, !f537

FLUE SPILLAGE SENSOR

{ISOLATEMAINSPOWER}<

Next: !p179, !f80

SPARK ELECTRODES

{ISOLATEMAINSPOWER}

Next: p191, !f189

SPARK ELECTRODE LEADS

{ISOLATEMAINSPOWER}
REMOVE SPARK ELECTRODE LEADS FROM ELECTRODES AND PCB

Next: p194, !f196

FLUE SPILLAGE SENSOR

{ISOLATEMAINSPOWER}<

Next: !p199, !f200

PRESSURE GAS IGNITION

{ISOLATEMAINSPOWER}<

Next: p478, !f206

PUMP LIMPET TEST

Next: p307, !f270

CH OPERATION

BOILER ON/OFF SWITCH ON
ROOM THERMOSTAT (IF FITTED) CALLING

Next: !p268, !f269

PUMP LIMPET TEST

Next: p272, !f279

DHW MODULATION

{ISOLATEMAINSPOWER}<

Next: p273, f274

TEMPERATURE DIFFERENTIAL CH

{ISOLATEMAINSPOWER}<

Next: !p277, !f278

INSPECTION ISOLATION VALVES FLOW AND RETURN

{ISOLATEMAINSPOWER}

Next: p301, !f302

PUMP LIMPET TEST

Next: p295, !f296

RESISTANCE PRIMARY SENSOR

{ISOLATEMAINSPOWER}
REMOVE YELLOW WIRES FROM DHW SENSOR

Next: p297, !f298

TEMPERATURE DIFFERENTIAL CH

{ISOLATEMAINSPOWER}<

Next: !p299, !f300

PUMP LIMPET TEST

Next: p303, !f304

CH DIVERTER CHECK

ENSURE SECONDARY HEA

Next: !p305, !f306

RESISTANCE DHW SENSOR

{ISOLATEMAINSPOWER}
REMOVE YELLOW WIRES FROM DHW SENSOR

Next: p267, !f311

ROOM THERMOSTAT/EXTERNAL CONTROLS RESISTANCE

{ISOLATEMAINSPOWER}
ROOM THERMOSTAT (IF FITTED) CALLING

Next: !p313, !f314

FULL VOLTAGE MODULATING SOLENOID

REMOVE CONNECTOR (BL

Next: p488, f323

PUMP LIMPET TEST

Next: p330, !f331

DIFFERENTIAL PLATE HEAT EX

{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS INDICATED

Next: p332, f333

RESISTANCE DHW SENSOR

{ISOLATEMAINSPOWER}
REMOVE YELLOW WIRES FROM DHW SENSOR

Next: p336, !f337

PRIMARY SENSOR (CH HIGH FLAME)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH SENSOR

Next: p338, !f339

INSPECTION BURNER AND INJECTOR

{ISOLATEMAINSPOWER}
REMOVE THE BURNER ASSEMBLY FROM THE BOILER

Next: !p340, ?342, ?344

TRANSFORMER VOLTAGE (OUTPUT)

BOILER ON/OFF SWITCH ON

Next: p41, f40

MAINS POWER

BOILER ON/OFF SWITCH ON

Next: !p354, !f355

TRANSFORMER RESISTANCE

{ISOLATEMAINSPOWER}<

Next: !p360, !f361

INFORMATION FAIL POINT D

Next: !p372, !f373

INFORMATION FAIL POINT E

Next: !p384, !f385

DIVERTER VALVE MICROSWITCH RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: !p382, !f383

PRIMARY SENSOR (CH HIGH FLAME)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH SENSOR

Next: !p390, !f391

DHW PUMP RUNS

Next: p399, f400

PUMP LIMPET TEST

Next: p403, !f404

PRESSURE BURNER MAX AND MIN

{ISOLATEMAINSPOWER}<

Next: p405, f406

PRESSURE BURNER CH MODE

{ISOLATEMAINSPOWER}<

Next: p415, !f416

OBSERVATION GAS VALVE TYPE

THE GAS VALVE WILL N

Next: p409, f410

ADJUSTMENT PRESSURE MAX AND MIN (DUNGS)

{ISOLATEMAINSPOWER}<

Next: !p413, !f414

PUMP VOLTAGE

{ISOLATEMAINSPOWER}

Next: !p47, f46

DIFFERENTIAL PRIMARY HEAT EXCHANGER

{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS INDICATED

Next: p417, f418

DIFFERENTIAL PLATE HEAT EX

{ISOLATEMAINSPOWER}
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS INDICATED

Next: p421, !f422

OBSERVATION RUN BOILER UP TO TEMPERATURE

{ISOLATEMAINSPOWER}<

Next: p423, ?425, ?427

OVERRUN OPERATION

BOILER ON/OFF SWITCH ON

Next: !p431, !f432

PRIMARY SENSOR (CH HIGH FLAME)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH SENSOR

Next: !p429, !f430

TRANSFORMER RESISTANCE

{ISOLATEMAINSPOWER}<

Next: !p45, !f44

PRIMARY SENSOR (CH HIGH FLAME)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH SENSOR

Next: !p460, !f461

DHW FLOW RATE ADJUSTER

{ISOLATEMAINSPOWER}

Next: p471, !f472

DHW INLET FILTER

{ISOLATEMAINSPOWER}
WATER OFF
BOILER DRAINED AND DISCHARGED

Next: p473, !f474

FLOW RESTRICTOR

{ISOLATEMAINSPOWER}
WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p475, !f476

RESISTANCE FLAME SENSE ELECTRODE

{ISOLATEMAINSPOWER}

Next: p479, !f480

RESISTANCE FLAME SENSE LEAD

{ISOLATEMAINSPOWER}<

Next: !p481, !f482

OBSERVATION GAS VALVE TYPE

THE GAS VALVE WILL N

Next: p489, f490

ADJUSTMENT PRESSURE MAX AND MIN (DUNGS)

{ISOLATEMAINSPOWER}<

Next: !p493, !f494

OBSERVATION GAS VALVE TYPE

THE GAS VALVE WILL N

Next: p498, f499

ADJUSTMENT PRESSURE MAX AND MIN (DUNGS)

{ISOLATEMAINSPOWER}<

Next: !p502, !f503

MAINS POWER

BOILER ON/OFF SWITCH ON

Next: !p512, f513

PRESSURE GAS INLET

{ISOLATEMAINSPOWER}<

Next: !p519, !f520

MAIN GAS VALVE SOLENOID RESISTANCE (FUSE INVESTIGATION)

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: p525, !f526

RESISTANCE GAS VALVE MODULATING SOLENOID (FUSE INVESTIGATION)

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: !p527, !f528

BURNER PRESSURE (GAS PRESENT)

{ISOLATEMAINSPOWER}
ATTACH A U-GAUGE TO THE OUTLET PRESSURE TEST POINT

Next: p65, !f64

RESISTANCE DHW SENSOR AT PCB

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: !p534, f535

OVERHEAT THERMOSTAT RESISTANCE - FAULT CODE

{ISOLATEMAINSPOWER}
DISCONNECT ORANGE WIRES FROM OVERHEAT THERMOSTAT
ENSURE BOILER IS COOL

Next: p394, !f574

OVERHEAT THERMOSTAT RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT ORANGE WIRES FROM OVERHEAT THERMOSTAT

Next: p69, !f68

MAIN GAS VALVE VOLTAGE

{ISOLATEMAINSPOWER}<

Next: p518, f78

SPARK ELECTRODES

{ISOLATEMAINSPOWER}

Next: !p67, !f66

PRIMARY SENSOR (CH CALLING)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH TEMPERATURE SENSOR

Next: p71, !f70

DHW SENSOR (CALLING)

{ISOLATEMAINSPOWER}
DISCONNECT YELLOW WIRES FROM DHW SENSOR
ENSURE DHW IS COOL

Next: p73, !f72

DIVERTER VALVE MICROSWITCH (RESISTANCE)

{ISOLATEMAINSPOWER}
DISCONNECT PLUG CONNECTOR (MARKED ST16) FROM PCB

Next: p75, !f74

FLUE SPILLAGE SENSOR

{ISOLATEMAINSPOWER}<

Next: !p77, !f76

PRIMARY SENSOR (CH HIGH FLAME)

{ISOLATEMAINSPOWER}
REMOVE RED WIRES FROM CH SENSOR

Next: p312, !f185