WORCESTER 230 RSF
G.C. NUMBER 47 311 1
HOT WATER
SELECTOR SWITCH WATER POSITION
HW BURNER MODULATION
{ISOLATEMAINSPOWER}<
HW HIGH FLAME
{ISOLATEMAINSPOWER}<
HW PILOT IGNITES
OPERATING SWITCH IN WATER POSITION
HW DEMAND INDICATOR
OPERATING SWITCH IN WATER POSITION
PUMP OVERRUN
OPERATING SWITCH IN HEATING AND WATER POSITION
TEMPERATURE CONTROL TO MAX
CENTRAL HEATING
SELECTOR SWITCH HEATING AND WATER POSITION
C/H BURNER MODULATION
OPERATING SWITCH IN HEATING & WATER POSITION
TEMPERATURE CONTROL TO MAX
C/H HIGH FLAME
{ISOLATEMAINSPOWER}<
C/H LOW FLAME
{ISOLATEMAINSPOWER}<
WATER PUMP RUNNING
{ISOLATEMAINSPOWER}
OPERATING SWITCH IN HEATING & WATER POSITION
C/H DEMAND INDICATOR
OPERATING SWITCH IN OFF POSITION
WORCESTER 230 RSF
{ISOLATEMAINSPOWER}<
C/H PILOT IGNITES
OPERATING SWITCH IN HEATING & WATER POSITION
CH LOW FLAME CORRECT PRESSURE
{ISOLATEMAINSPOWER}<
FUSE INVESTIGATION TREE
BLANK
HW BURNER MODULATION
HOT WATER TEMPERATURE SENSOR FIXING
HW DEMAND INDICATOR
DIVERTER VALVE (MICROSWITCH)
CH LOW FLAME CORRECT
MODUREG-GAS VALVE
CH HIGH FLAME
CENTRAL HEATING TEMPERATURE SENSOR FIXING
CH MODULATION
CENTRAL HEATING TEMPERATURE SENSOR.
CH BURNER MODULATION
TEMPERATURE CONTROL POTENTIOMETER
CH BURNER MODULATION
MODUREG-GAS VALVE
HW BURNER MODULATION
HOT WATER TEMPERATURE SENSOR
CH
INLET PRESSURE
CH HIGH FLAME 2
CENTRAL HEATING TEMPERATURE SENSOR.
CH HIGH FLAME
TEMPERATURE CONTROL POTENTIOMETER
ELECTRICAL CHECK
ELECTRICAL CHECK
POWER ON INDICATOR
POWER ON INDICATOR NEON (AMBER)
C/H HIGH FLAME
DIVERTER VALVE (DIAPHRAGM SPINDLE)
CH DEMAND INDICATOR
OPERATING SWITCH / PROGRAMMER
CH DEMAND INDICATOR
DIVERTER VALVE (MICROSWITCH)
CH DEMAND INDICATOR
DEMAND INDICATOR NEON (GREEN)
FROST THERMOSTAT (IF FITTED)
FROST THERMOSTAT (OPTIONAL).
HW HIGH FLAME
DIVERTER VALVE (MICROSWITCH)
CH HIGH FLAME DOES NOT INCREASE
DIVERTER VALVE (DIAPHRAGM SPINDLE)
POWER ON INDICATOR
MAINS FUSE
FUSE F1
FUSE F1.
CH PILOT IGNITES
CENTRAL HEATING TEMPERATURE SENSOR.
CH PILOT IGNITES
FUSE F2.
AIR PRESSURE SWITCH: NO AIR
AIR PRESSURE SWITCH
CH PILOT IGNITES
OVERHEAT THERMOSTAT
CH PILOT IGNITES
FLUE ASSEMBLY
AIR PRESSURE TUBES
AIR PRESSURE TUBES
PILOT IGNITES
FAN ASSEMBLY
PILOT IGNITES
INLET PRESSURE
HW DEMAND INDICATOR
WATER SUPPLY
HW DEMAND INDICATOR
ISOLATING VALVE (DHW)
HW DEMAND INDICATOR
FILTER - STAINLESS STEEL
HW DEMAND INDICATOR
FLOW REGULATOR
FUSE INVESTIGATION
WATER PUMP.
FUSE INVESTIGATION
FAN ASSEMBLY
FUSE INVESTIGATION
MAIN GAS VALVE
CH PILOT IGNITES
ELECTRODE LEAD (SPARK)
CH PILOT IGNITES
ELECTRODE (SPARK)
CH PILOT IGNITES
PILOT INJECTOR
PILOT VOLTAGE
IGNITION CONTROL BOARD
WATER PUMP RUNNING
PUMP OVERRUN THERMOSTAT
CH LOW FLAME
SENSING ELECTRODE LEAD
CH LOW FLAME
SENSING ELECTRODE
CH LOW FLAME
MAIN GAS VALVE
PUMP OVERRUN
PUMP OVERRUN THERMOSTAT
HW PILOT IGNITES
HOT WATER TEMPERATURE SENSOR
DHW HIGH FLAME
HOT WATER TEMPERATURE SENSOR
HW DEMAND INDICATOR
OPERATING SWITCH / PROGRAMMER
HW HIGH FLAME
MODUREG-GAS VALVE
DHW
INLET PRESSURE
HOT WATER
SECONDARY HEAT EXCHANGER (WATER TO WATER)
CH MODULATION
MAIN DRIVER BOARD
DHW MODULATION
MAIN DRIVER BOARD
HOT WATER
DIVERTER VALVE
MODUREG-GAS VALVE
MODUREG-GAS VALVE
PRESSURE INCREASES IMMEDIATELY
MAIN DRIVER BOARD
FAULTY POWER NEON
Z REDIRECT
CH HIGH FLAME
MAIN DRIVER BOARD
PRESSURE INCREASES IMMEDIATELY
DIVERTER VALVE (MICROSWITCH)
CH DEMAND INDICATOR
ROOM THERMOSTAT (OPTIONAL)
FAULTY DEMAND NEON
Z REDIRECT
DEMAND NEON LIT
PUMP OVERRUN THERMOSTAT
DHW HIGH FLAME
MAIN DRIVER BOARD
C/H HIGH FLAME
DIVERTER VALVE (MICROSWITCH)
MAINS ELECTRICITY SUPPLY
MAINS ELECTRICITY SUPPLY
MAINS FUSE
Z REDIRECT
FUSE INVESTIGATION F1
Z REDIRECT
CH PILOT IGNITES
MAIN DRIVER BOARD
CH PILOT IGNITESFUSE INVESTIGATION F1
Z REDIRECT
CH PILOT IGNITES
FAN ASSEMBLY
AIR PRESSURE SWITCH: NO AIR
IGNITION CONTROL BOARD
SPARK GENERATOR
AIR PRESSURE SWITCH
CH PILOT IGNITES
MAIN GAS VALVE
HW DEMAND INDICATOR
DIVERTER VALVE (DIAPHRAGM SPINDLE)
HW DEMAND INDICATOR
SECONDARY HEAT EXCHANGER (WATER TO WATER)
NO FAULT FUSE INVESTIGATION
FUSE FURTHER INVESTIGATION
CH PILOT IGNITES
MAIN GAS VALVE (PILOT VALVE)
SPARK GENERATOR
IGNITION CONTROL BOARD
WATER PUMP RUNNING
WATER PUMP.
CH LOW FLAME
IGNITION CONTROL BOARD
CH LOW FLAME
MAIN BURNER
CENTRAL HEATING
PRIMARY HEAT EXCHANGER (GAS TO WATER)
HOT WATER UNSATISFACTORY RADIATORS REMAIN COLD
CHARACTERISTIC TEST FROM HOT WATER
HOT WATER UNSATISFACTORY RADIATORS GET WARM
CHARACTERISTIC TEST FROM HOT WATER
BURNER PRESSURE DOES NOT INCREASE.
CHARACTERISTIC TEST FROM C/H HIGH FLAME
BURNER PRESSURE INCREASES IMMMEDIATELY.
CHARACTERISTIC TEST FROM C/H HIGH FLAME
DEMAND NEON ILLUMINATED WITH NO DEMAND
CHARACTERISTIC TEST FROM C/H DEMAND INDICATOR
DEMAND NEON DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM C/H DEMAND INDICATOR
PILOT PERMANENTLY LIT
CHARACTERISTIC TEST FROM C/H PILOT IGNITES
PILOT DOES NOT LIGHT
CHARACTERISTIC TEST FROM C/H PILOT IGNITES
HEAT EXCHANGER NOISY
CHARACTERISTIC TEST FROM CENTRAL HEATING
HEAT EXCHANGER QUIET
CHARACTERISTIC TEST FROM CENTRAL HEATING
24/08/2018 11:04:12 1808_1_50_1 20/09/2018 10:51:50
24/08/2018 14:05:40
H/W SENSOR FIXING
{ISOLATEMAINSPOWER}
INLET PRESSURE DHW
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
GAS ON
C/H SENSOR FIXING
{ISOLATEMAINSPOWER}
TEMPERATURE POTENTIOMETER
{ISOLATEMAINSPOWER}<
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE THE DIVERTER VALVE MICRO SWITCH COVER.
OPERATING SWITCH
OPERATING SWITCH IN THE HEATING & WATER POSITION
FUSE F1
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB (USE INSULATION MAT AS REQUIRED)
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE THE DIVERTER VALVE MICRO SWITCH COVER.
RESISTANCE MAINS FUSE
{ISOLATEMAINSPOWER}
REMOVE THE FUSE FROM THE FUSED SPUR
SENSOR CHECK RELAY OPERATION
{ISOLATEMAINSPOWER}
OPERATING SWITCH IN HEATING & WATER POSITION
C/H SENSOR
{ISOLATEMAINSPOWER}
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X2 ON MAIN DRIVER BOARD
IGNITION CONTROL BOARD LIVE
{ISOLATEMAINSPOWER}
OPERATING SWITCH IN HEATING & WATER POSITION
RESISTANCE PUMP
{ISOLATEMAINSPOWER}
DISCONNECT 4 PIN CONNECTOR X6 MARKED "PUMP" ON MAIN DRIVER BOARD
SPARK ELECTRODE LEAD
{ISOLATEMAINSPOWER}
WATER PUMP VOLTAGE
{ISOLATEMAINSPOWER}<
MAIN GAS VALVE VOLTAGE
{ISOLATEMAINSPOWER}<
FLAME SENSE ELECTRODE LEAD
{ISOLATEMAINSPOWER}
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE THE DIVERTER VALVE MICRO SWITCH COVER.
MODUREG VOLTAGE DHW
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB (USE INSULATION MAT AS REQUIRED)
HW SENSOR
{ISOLATEMAINSPOWER}
REMOVE THE MIDDLE PLUG (RED WIRES) FROM CONNECTOR X2 ON MAIN DRIVER BOARD
DIVERTER VALVE MICROSWITCHES HW
{ISOLATEMAINSPOWER}
OPERATING SWITCH IN WATER POSITION
C/H SENSOR
{ISOLATEMAINSPOWER}
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X2 ON MAIN DRIVER BOARD
MODUREG RESISTANCE
{ISOLATEMAINSPOWER}
REMOVE CONNECTOR FROM X2 ON DRIVER PCB
TEMPERATURE POTENTIOMETER
{ISOLATEMAINSPOWER}<
HW SENSOR
{ISOLATEMAINSPOWER}
REMOVE THE MIDDLE PLUG (RED WIRES) FROM CONNECTOR X2 ON MAIN DRIVER BOARD
INLET PRESSURE CH
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
GAS ON
C/H SENSOR
{ISOLATEMAINSPOWER}
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X2 ON MAIN DRIVER BOARD
MODUREG VOLTAGE C/H
OPERATING SWITCH HEATING & WATER POSITION
RESISTANCE DIVERTER VALVE MICROSWITCH DHW HIGH FLAME (OPEN CIRCUIT)
{ISOLATEMAINSPOWER}<
RESISTANCE DIVERTER VALVE MICROSWITCH DHW HIGH FLAME (OPEN CIRCUIT)
{ISOLATEMAINSPOWER}<
ROOM THERMOSTAT
{ISOLATEMAINSPOWER}<
C/H DEMAND VOLTAGE
OPERATING SWITCH IN HEATING & WATER POSITION
OBSERVATION DISCONNECT FROST THERMOSTAT (IF FITTED)
{ISOLATEMAINSPOWER}<
RESISTANCE DIVERTER VALVE MICROSWITCH DHW HIGH FLAME
{ISOLATEMAINSPOWER}<
FAN RUNNING
OPERATING SWITCH IN HEATING & WATER POSITION
AIR PRESSURE SWITCH: AIR DETECT
{ISOLATEMAINSPOWER}<
AIR PRESSURE SWITCH: NO AIR
{ISOLATEMAINSPOWER}
DISCONNECT CONNECTOR CN2 FROM THE IGNITION CONTROL BOARD
FUSE F2
{ISOLATEMAINSPOWER}
FAN VOLTAGE
OPERATING SWITCH IN HEATING & WATER POSITION
INLET PRESSURE
{ISOLATEMAINSPOWER}
CONNECT U GAUGE TO INLET PRESSURE TEST POINT
INSPECTION AIR PRESSURE TUBES
{ISOLATEMAINSPOWER}
INSPECT FAN ASSEMBLY
{ISOLATEMAINSPOWER}
REMOVE FAN ASSEMBLY FROM BOILER
PILOT SOLENOID VOLTAGE
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB (USE INSULATION MAT AS REQUIRED)
INSPECTION DHW ISOLATION VALVE
{ISOLATEMAINSPOWER}
INSPECTION DHW FILTER
{ISOLATEMAINSPOWER}
TURN OFF COLD WATER SUPPLY TO APPLIANCE
INSPECTION FLOW REGULATOR
{ISOLATEMAINSPOWER}
TURN OFF COLD WATER SUPPLY TO APPLIANCE
RESISTANCE FAN
{ISOLATEMAINSPOWER}
DISCONNECT 5 PIN CONNECTOR MARKED CN5 ON THE IGNITION PCB
RESISTANCE GAS VALVE
{ISOLATEMAINSPOWER}
DISCONNECT 9 PIN CONNECTOR MARKED CN3 ON THE IGNITION PCB
SPARK ELECTRODE CHECK
{ISOLATEMAINSPOWER}
PILOT
{ISOLATEMAINSPOWER}
MAIN GAS VALVE MECHANICAL OPERATION
{ISOLATEMAINSPOWER}<
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
System Information
- Total Tests: 176
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control