Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
INTERGAS COMBI COMPACT ECO RF 24
GLOBALLY REPLACED
FUSE INVESTIGATION TREE
OUTSIDE MODEL
FAULT CODE 29, 30 - GAS VALVE RELAY FAULTY
OUTSIDE MODEL
FAULT CODE 2 - S1 AND S2 INTERCHANGED
OUTSIDE MODEL
FAULT CODE 1 - TEMPERATURE TOO HIGH
OUTSIDE MODEL
FAULT CODE 0 - SENSOR FAULT AFTER SELF CHECK
OUTSIDE MODEL
FAULT CODE 20, 21, 22, 23, 24 - SENSOR FAULT S2 (RETURN)
OUTSIDE MODEL
FAULT CODE 10, 11, 12, 13, 14 - SENSOR FAULT S1 (FLOW)
OUTSIDE MODEL
OBSERVATION DISPLAY OPERATES AND SELF CHECK
ENSURE NO DEMANDS
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
INFORMATION HOW TO SET MULTIMETER TO DIODE TEST
THE IMAGES BELOW SHO
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
HEAT EXCHANGER ASSEMBLY (FLUEWAYS)
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
TRAP - CONDENSATE
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
GAS INLET PRESSURE
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
HEAT EXCHANGER ASSEMBLY (FLUEWAYS)
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
CABLE - IGNITION C/W CAP
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
MODULE - IGNITION - SIEMENS SMART
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
TRAP - CONDENSATE
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
GAS INLET PRESSURE
OPERATION DHW - TOO HOT
NTC - DHW
OBSERVATION DHW MODULATION
NTC - DHW
OPERATION DHW - TOO COOL
NTC - DHW
OPERATION DHW - DHW COOL RADS COOL
GAS INLET PRESSURE
FAULT CODE 4
Z REDIRECT
OBSERVATION PUMP RUNS CH DEMAND - AC VOLTAGE
PCB - CONTROL
FAULT CODE 5
Z REDIRECT
OPERATION CH - NOISY
PUMP - YONOS
FAULT CODE 6
Z REDIRECT
OPERATION CH - UP TO TEMP RADS COOL
PUMP - YONOS
OPERATION CH - DOES NOT REACH TEMP - FLOW
NTC 1 -2 (FLOW & RETURN)
OPERATION CH - DOES NOT REACH TEMP - RETURN
NTC 1 -2 (FLOW & RETURN)
OBSERVATION PUMP OVERRUN
PCB - CONTROL
FAULT CODE PAGE 2
Z REDIRECT
OBSERVATION DISPLAY OPERATES AND SELF CHECK
MAINS FUSE
INFORMATION CASE REMOVAL
Z REDIRECT
OBSERVATION BOILER RUNS FOR DHW - NO VOLTAGE TO FAN
PCB - CONTROL
SET PREHEAT AND DHW / CH TEMPERATURE
Z REDIRECT
OBSERVATION BOILER RUNS FOR DHW - FAN RUNS
CABLE - FAN
OBSERVATION BOILER RESPONDS TO CH DEMAND - OPENTHERM
PCB - CONTROL
OBSERVATION BOILER RESPONDS TO CH DEMAND - 24V
PCB - CONTROL
INSPECTION SYSTEM PRESSURE AT TEMPERATURE
EXPANSION VESSEL
PRESSURE SYSTEM COLD - NO VOLTAGE TO SENSOR
PCB - CONTROL
PRESSURE SYSTEM COLD
CABLE - NTC
PRESSURE SYSTEM COLD - IGNORING SENSOR
PCB - CONTROL
FUSE INVESTIGATION
PUMP - YONOS
FAULT CODE 10 11 12 13 14
PCB - CONTROL
FAULT CODE 10 11 12 13 14
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 20 21 22 23 24
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 20 21 22 23 24
PCB - CONTROL
FAULT CODE 0 - FLOW
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 0
PCB - CONTROL
FAULT CODE 0 - RETURN
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 8 - NO VOLTAGE TO FAN
PCB - CONTROL
FAULT CODE 8 - FAN DOES NOT RUN
CABLE - FAN
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
FAULT CODE 8 - FAN RUNS
CABLE - FAN
FAULT CODE 29 30
PCB - CONTROL
FAULT CODE 2
NTC 1 -2 (FLOW & RETURN) - FITMENT
FAULT CODE 2 - FLOW
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 2 - RETURN
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 2
PCB - CONTROL
FAULT CODE 1 - FLOW
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 1 - RETURN
NTC 1 -2 (FLOW & RETURN)
OPERATION CH - DISPLAY REMAINS ON - FLOW
NTC 1 -2 (FLOW & RETURN)
OPERATION CH - DISPLAY REMAINS ON 1 - RETURN
NTC 1 -2 (FLOW & RETURN)
OPERATION CH - NOISY
AIR IN BOILER / SYSTEM
OPERATION CH - UP TO TEMP RADS COOL
AIR IN BOILER / SYSTEM
OBSERVATION CH MODULATION - FLOW
NTC 1 -2 (FLOW & RETURN)
FAULT CODE 1
PCB - CONTROL
OBSERVATION DISPLAY OPERATES AND SELF CHECK
CABLE - FAN
FUSE INVESTIGATION
GAS VALVE VGU 76S - SIEMENS SMART
FUSE INVESTIGATION
MODULE - IGNITION - SIEMENS SMART
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
CABLE - IGNITION C/W CAP
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
HEAT EXCHANGER ASSEMBLY (FLUEWAYS)
OPERATION DHW - DHW COOL RADS COOL
INJECTOR
OPERATION DHW - DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY (FLUEWAYS)
OPERATION DHW - DHW COOL RADS COOL
BURNER BRAIDED STAINLESS STEEL
OBSERVATION PREHEAT OPERATION
PCB - CONTROL
OBSERVATION DISPLAY OPERATES AND SELF CHECK - FIRES NO DEMAND - FROST
NTC 1 -2 (FLOW & RETURN)
OBSERVATION DISPLAY OPERATES AND SELF CHECK - FIRES NO DEMAND
FROST PROTECTION
OPERATION DHW - DHW COOL RADS COOL
EXTERNAL MIXING
FUSE INVESTIGATION - EARTH
MODULE - IGNITION - SIEMENS SMART
OPERATION CH - NOISY
PCB PARAMETERS
OPERATION CH - UP TO TEMP RADS COOL
PCB PARAMETERS
OPERATION CH - DOES NOT REACH TEMP
PCB PARAMETERS
OPERATION CH - UP TO TEMP RADS COOL
VALVE - RETURN AND VALVE - FLOW
OBSERVATION BOILER RUNS FOR DHW - BLANK
NTC - DHW
OBSERVATION BOILER RUNS FOR DHW - 1
NTC - DHW
OBSERVATION DHW FLOW RATE
WATER SUPPLY
OBSERVATION DHW FLOW RATE
VALVE - WATER - COLD
OBSERVATION DHW FLOW RATE
FLOW SENSOR - SIKA
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
TRAP - CONDENSATE
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
GAS VALVE VGU 76S - SIEMENS SMART AND PCB - CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - NO VOLTAGE TO GAS VALVE
MODULE - IGNITION - SIEMENS SMART
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - NO VOLTAGE TO SPARK GEN
PCB - CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
PIN - IGNITION
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
GAS VALVE VGU 76S - SIEMENS SMART
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
BURNER BRAIDED STAINLESS STEEL
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
BURNER BRAIDED STAINLESS STEEL
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
BURNER BRAIDED STAINLESS STEEL
OPERATION DHW - DHW COOL RADS HEAT
PCB - CONTROL
OPERATION DHW - TOO HOT
PCB - CONTROL
OPERATION DHW - NOISY
HEAT EXCHANGER (WATERWAYS)
OBSERVATION DHW MODULATION
PCB - CONTROL
OBSERVATION PUMP RUNS CH DEMAND
PUMP - YONOS
OPERATION CH - NOISY
HEAT EXCHANGER (WATERWAYS)
OBSERVATION DISPLAY OPERATES AND SELF CHECK - FIRING NO DEMAND
OPEN TAP OR LEAK
FAULT CODE PAGE 1
Z REDIRECT
OBSERVATION DISPLAY OPERATES AND SELF CHECK
SYSTEM PRESSURE
OBSERVATION DISPLAY OPERATES AND SELF CHECK
SENSOR - PRESSURE - CH (BLOCKAGE)
OBSERVATION BOILER RUNS FOR DHW - IGNORING FAN HALL
PCB - CONTROL
OBSERVATION BOILER RUNS FOR DHW - HALL SENSOR
SET - REPLACEMENT - FAN
OBSERVATION BOILER RUNS FOR DHW - NOT RUNNING
SET - REPLACEMENT - FAN
INSPECTION SYSTEM PRESSURE AT TEMPERATURE
HOSE DN10 1=500 - EXPANSION VESSEL
PRESSURE SYSTEM COLD
SYSTEM PRESSURE (TOO HIGH)
PRESSURE SYSTEM COLD
SENSOR - PRESSURE - CH
PRESSURE SYSTEM COLD
SENSOR - PRESSURE - CH (BLOCKAGE)
FAULT CODE 10 11 12 13 14
Z REDIRECT
FAULT CODE 10 11 12 13 14
CABLE - NTC
FAULT CODE 20 21 22 23 24
CABLE - NTC
FAULT CODE 20 21 22 23 24
Z REDIRECT
FAULT CODE 0 - FLOW THERMISTOR
CABLE - NTC
FAULT CODE 0
Z REDIRECT
FAULT CODE 0 - RETURN THERMISTOR
CABLE - NTC
FAULT CODE 8 - NOT RUNNING
SET - REPLACEMENT - FAN
FAULT CODE 8 - IGNORING FAN HALL
PCB - CONTROL
FAULT CODE 8 - HALL SENSOR
SET - REPLACEMENT - FAN
FAULT CODE 29 30
Z REDIRECT
FAULT CODE 2 - FLOW THERMISTOR
CABLE - NTC
FAULT CODE 2 - RETURN THERMISTOR
CABLE - NTC
FAULT CODE 2
Z REDIRECT
FAULT CODE 1 - FLOW THERMISTOR
CABLE - NTC
FAULT CODE 1 - RETURN THERMISTOR
CABLE - NTC
FAULT CODE 1 - SEND TO START OF TESTING CH
Z REDIRECT
OPERATION CH - DISPLAY REMAINS ON 1
PCB - CONTROL
OBSERVATIO CH MODULATION
PCB - CONTROL
OBSERVATION DISPLAY OPERATES AND SELF CHECK - NO DISPLAY
PCB - CONTROL
OBSERVATION DISPLAY OPERATES AND SELF CHECK
SET - REPLACEMENT - FAN
OPERATION DHW - DHW COOL RADS COOL
HEAT EXCHANGER (WATERWAYS)
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - NOT OPENING
GAS VALVE VGU 76S - SIEMENS SMART
FUSE INVESTIGATION
NO FAULT FUSE INVESTIGATION
OPERATION CH - DOES NOT REACH TEMP
PCB - CONTROL
OBSERVATION BOILER RUNS FOR DHW - BLANK
FLOW SENSOR - SIKA
OBSERVATION BOILER RUNS FOR DHW - 1
PCB - CONTROL
OBSERVATION DHW FLOW RATE
HEAT EXCHANGER (FLOW RATE)
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE
GAS INLET PRESSURE
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - NO VOLTAGE TO GAS VALVE
PCB - CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - NO SPARKING
MODULE - IGNITION - SIEMENS SMART
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE - ONLY OPENING PARTIALLY
GAS VALVE VGU 76S - SIEMENS SMART
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT BAFFLES OUT
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
DHW COOL, PUMP RUNS AND RADIATORS HEAT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
HEAT EXCHANGER NOISY (KETTLES) DURING OPERATION
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL, RADIATORS COOL
CHARACTERISTIC TEST FROM OPERATION DHW
RADIATORS HEAT BUT HEAT EXCHANGER NOISY (KETTLES)
CHARACTERISTIC TEST FROM OPERATION CH
BOILER REACHES TEMPERATURE BUT RADIATORS NOT HEATING
CHARACTERISTIC TEST FROM OPERATION CH
BOILER AND RADIATORS DO NOT REACH TEMPERATURE
CHARACTERISTIC TEST FROM OPERATION CH
DISPLAY FLASHING SHOWING LOW PRESSURE
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK
24V CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION TYPE OF EXTERNAL CONTROLS
OPENTHERM CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION TYPE OF EXTERNAL CONTROLS
BOILER SHOWS FAULT CODE
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK
BOILER DOES NOT SHOW PRESSURE
CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD
PRESSURE DOES NOT CHANGE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD
SYSTEM PRESSURE TOO HIGH
CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD
DISPLAY DOES NOT OPERATE
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK
BURNER DOES NOT IGNITE - DISPLAY REMAINS ON 1
CHARACTERISTIC TEST FROM OPERATION CH
BOILER FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK
DISPLAY REMAINS BLANK (AFTER SELF CHECK)
CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW
DISPLAY REMAINS ON 1
CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW
DISPLAY REMAINS ON 3 (MAY GO TO LOCKOUT CODE 8)
CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
INLET PRESSURE DOES NOT DROP DURING SPARKING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
INLET PRESSURE DIES AWAY DURING SPARKING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
06/12/2018 09:24:00 1811_2_50_1 22/01/2019 14:18:14
06/12/2018 09:45:26
RESISTANCE FLOW THERMISTOR (S1) AND HARNESS
DISCONNECT X7 FROM THE PCB
INSPECTION INJECTOR
UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT X7 FROM THE PCB
OBSERVATION TYPE OF EXTERNAL CONTROLS
{GAINPCBACS}
VOLTAGE PUMP (AC)
{GAINPCBACS}
RESISTANCE PUMP
DISCONNECT X2 FROM THE PCB
OBSERVATION TYPE OF EXTERNAL CONTROLS (SELF CHECK)
{GAINPCBACS}
RESISTANCE MAINS FUSE
REMOVE FUSE FROM FUSED SPUR
VOLTAGE PRESSURE SENSOR (PRESSURE)
{GAINPCBACS}
OBSERVATION DISCONNECT X4
DISCONNECT X4 FROM THE PCB AND MAKE SAFE
RESISTANCE HARNESS FAN
DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB
PRESSURE EXPANSION VESSEL
DRAIN BOILERS HEATING CIRCUIT
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2) AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
RESISTANCE FLOW THERMISTOR (S1) AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
VOLTAGE FAN DEMAND
{GAINPCBACS}
DISCONNECT PLUG FROM FAN AND MAKE SAFE
RESISTANCE HARNESS FAN
DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
RESISTANCE FLOW THERMISTOR (S1) AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
OBSERVATION DISCONNECT FAN
DISCONNECT PLUG FROM FAN
RECONNECT X3 AT THE PCB IF YOU HAVE NOT ALREADY DONE SO
OBSERVATION IS BOILER IN FROST PROTECTION
NO DEMANDS
RESISTANCE DHW THERMISTOR
DISCONNECT CONNECTOR TO DHW THERMISTOR (REQUIRES FLUE PIPE & SUMP / CONDENSATE REMOVAL)
VOLTAGE FAN DEMAND
{GAINPCBACS}
DISCONNECT PLUG FROM FAN AND MAKE SAFE
RESISTANCE GAS VALVE
DISCONNECT PLUG FROM GAS VALVE
VOLTAGE SPARK GENERATOR
{GAINPCBACS}
INSPECTION FLUEWAYS
REMOVE GAS / FAN / BURNER ASSEMBLY
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
PRESSURE FAN
ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE
RESISTANCE IGNITION / RECTIFICATION LEAD
DISCONNECT RECTIFICATION LEAD FROM SPARK ELECTRODE AND IGNITION MODULE
INSPECTION FLUEWAYS
REMOVE GAS / FAN / BURNER ASSEMBLY
RESISTANCE IGNITION MODULE RECTIFICATION
DISCONNECT X1 FROM THE PCB
DISCONNECT SPARK / RECTIFICATION LEAD FROM THE IGNITION MODULE
INSPECTION ELECTRODE
REMOVE IGNITION / RE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
PRESSURE FAN
ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE
INSPECTION FLUEWAYS
REMOVE GAS / FAN / BURNER ASSEMBLY
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT X7 FROM THE PCB
PRESSURE GAS INLET (DHW TOO COOL)
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
INSPECTION PUMP
DRAIN BOILER PRIMARY CIRCUIT
REMOVE GAS VALVE
INSPECTION PUMP
DRAIN BOILER PRIMARY CIRCUIT
REMOVE GAS VALVE
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
OBSERVATION ISOLATE DHW
TURN DHW ISOLATION V
RESISTANCE PCB FUSE
REMOVE FUSE FROM HOLDER ON THE PCB
RESISTANCE HARNESS FAN
DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB
OBSERVATION LINK 24V CONTROLS
REMOVE 24V CONTROL C
OBSERVATION LINK OPENTHERM CONTROLS
REMOVE OPENTHERM CON
VOLTAGE PRESSURE SENSOR (PERMANENT)
{GAINPCBACS}
VOLTAGE PRESSURE SENSOR (PRESSURE)
{GAINPCBACS}
RESISTANCE HARNESS PRESSURE SENSOR
DISCONNECT PLUG FROM WATER PRESSURE SENSOR
DISCONNECT X7 FROM THE PCB
VOLTAGE MAINS AT PCB
{GAINPCBACS}
RESISTANCE RETURN THERMISTOR (S2) AND HARNESS
DISCONNECT X7 FROM THE PCB
VOLTAGE FAN HALL SENSOR
{GAINPCBACS}
RESISTANCE HARNESS FAN
DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB
RESISTANCE FLOW THERMISTOR (S1) AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE RETURN THERMISTOR (S2) AND HARNESS
DISCONNECT X7 FROM THE PCB
RESISTANCE RETURN THERMISTOR (S2) AND HARNESS
DISCONNECT X7 FROM THE PCB
OBSERVATION BOILER RESET (1)
ENSURE BOILER IS COOL
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
RESISTANCE RETURN THERMISTOR (S2)
DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR
OBSERVATION DISCONNECT X3
DISCONNECT X3 FROM THE PCB
RESISTANCE GAS VALVE
DISCONNECT PLUG FROM GAS VALVE
DIODE TEST GAS VALVE HARNESS
REMOVE THE CONNECTOR
RESISTANCE IGNITION / RECTIFICATION LEAD
DISCONNECT RECTIFICATION LEAD FROM SPARK ELECTRODE AND IGNITION MODULE
INSPECTION INJECTOR
UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR
INSPECTION INJECTOR
UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR
VOLTAGE DHW FLOW SENSOR (DEMAND)
{GAINPCBACS}
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT X7 FROM THE PCB
INSPECTION INJECTOR
UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR
INSPECTION FLUEWAYS
REMOVE GAS / FAN / BURNER ASSEMBLY
INSPECTION BURNER
REMOVE FAN / GAS VALVE / BURNER ASSEMBLY
RESISTANCE FLOW THERMISTOR (S1)
DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR
TEMPERATURE DIFFERENCE BOILER TO TAP (MIXER PASSING)
ATTACH TEMPERATURE CLAMP TO DHW OUTLET PIPE UNDERNEATH BOILER (SEE PICTURE)
RESISTANCE HARNESS DHW FLOW SENSOR
DISCONNECT PLUG FROM FLOW SENSOR
DISCONNECT X7 FROM THE PCB
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT X7 FROM THE PCB
INSPECTION INJECTOR
UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR
RESISTANCE HARNESS GAS VALVE TO EARTH
DISCONNECT X1 FROM THE PCB
INSPECTION PARAMETERS 3 AND 3.
NO DEMANDS
INSPECTION PARAMETERS 3 AND 3.
NO DEMANDS
INSPECTION PARAMETERS 3 AND 3.
NO DEMANDS
INSPECTION DHW FLOW SENSOR
DRAIN BOILER DHW CIR
VOLTAGE FAN HALL SENSOR
{GAINPCBACS}
PRESSURE GAS INLET AND DROP
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
OBSERVATION SPARKING AT GENERATOR
REMOVE IGNITION LEAD
VOLTAGE GAS VALVE
{GAINPCBACS}
DIODE TEST GAS VALVE HARNESS
REMOVE THE CONNECTOR
PRESSURE FAN
ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE
INSPECTION ELECTRODE
REMOVE IGNITION / RE
System Information
- Total Tests: 359
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control