Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect X1 from the PCB
Measurement:
Measure between each of the 4 pins at X1, in turn, to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L) on each wire.
Resistance should be greater than 1MΩ (or O.L) on each wire.

Isolate as per TOPs P4
and refit as necessary