Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
FERROLI MODENA / T-ONE
GLOBALLY REPLACED
OBSERVATION APPLIANCE SELF CHECK
ENSURE NO DEMANDS
ECO MODE ON (ECO ON THE DISPLAY)
FAN INVESTIGATION F15,A05
INTENTIONALLY BLANK HEADER FOR F15 AND A05
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
RETURN THERMISTOR INVESTIGATION F11
INTENTIONALLY BLANK HEADER FOR F11
FLOW / STAT THERMISTOR INVESTIGATION F10, F14 AND F52
OK TO BE BLANK
EXHAUST TEMP SENSOR INVESTIGATION F13
OK TO BE BLANK
POWER SUPPLY VOLTAGE F34
INTENTIONALLY BLANK HEADER FOR F34
POWER SUPPLY FREQUENCY F35
INTENTIONALLY BLANK HEADER FOR F35
FLAME DETECTED AFTER BURNER SHUTDOWN A02
INTENTIONALLY BLANK HEADER FOR A02 FAULT CODE
GAS VALVE A62
INTENTIONALLY BLANK HEADER FOR A62 FAULT CODE
BURNER SHUTDOWN A06
INTENTIONALLY BLANK HEADER FOR A06
FUSE INVESTIGATION
INTENTIONALLY BLANK HEADER FOR FUSE INVESTIGATION
OVERHEAT INVESTIGATION - A03
OK TO BE BLANK
F43 INVESTIGATION
OK TO BE BLANK
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
OBSERVATION DHW PREHEAT OPERATION
ENSURE APPLIANCE IS
DHW SENSOR INVESTIGATION F12
OK TO BE BLANK
PCB FAULT - A61, A63, A65, F64, F66
OK TO BE BLANK
INCORRECT SYSTEM WATER PRESSURE - F37
OK TO BE BLANK
WATER PRESSURE SENSOR FAULT - F47
OK TO BE BLANK
FLOW SENSOR DISCONNECTED A41
OK TO BE BLANK
OBSERVATION DHW DEMAND RECOGNISED
ECO MODE ON (ECO ON DISPLAY)
TURN HOT WATER TAP ON WITH A FLOW RATE OF 2 L/MIN
DHW TEMP SENSOR NOT CONNECTED A44
OK TO BE BLANK
HIGH LIMIT PROTECTION IN CH F50
OK TO BE BLANK
DHW ISOLATION VALVE
PACK - ISOLATION VALVES (COLD WATER)
INSUFFICIENT
WATER SUPPLY
BLANK FOR FAULT CODES 2
Z DIRECTION CHOICE OR CONTINUE
CANCELLING AIR PURGE INFO
Z DIRECTION CHOICE OR CONTINUE
BLOWN THROUGH FATIGUE
FUSE MAINS
BLANK FOR FUSE FH1
Z DIRECTION CHOICE OR CONTINUE
NO DISPLAY
PCB
SHORTED
HARNESS X2 / X3
NO POWER TO PUMP
PCB
PUMP DOES NOT RUN
HARNESS X2 / X3
PUMP RUNS CONTINUOUSLY
SENSOR - DHW
UNSATISFACTORY
GAS INLET PRESSURE
FLAT
EXPANSION VESSEL - 7 LITRE
ONLY PARTIALLY OPENING GAS VALVE
PIPE - INTERNAL - CONDENSATE
AIR GAS MIXER RESTRICTED
FAN AND BURNER ASSEMBLY
DOES NOT IGNITE
ELECTRODE C/W LEAD
DOES NOT IGNITE
SILENCER - AIR
GAS VALVE DAMAGED PCB
PCB AND GAS VALVE
GAS VALVE SECTION
HARNESS X2 / X3
NO PRESSURE DROP
FLUE
LOW CAUSING BAFFLING
GAS INLET PRESSURE
BLOCKED CAUSING BAFFLING
PIPE - INTERNAL - CONDENSATE
BAFFLING
SILENCER - AIR
DOES NOT ESTABLISH
PIPE - INTERNAL - CONDENSATE
LOW CAUSING NO RECTIFICATION
GAS INLET PRESSURE
DOES NOT ESTABLISH
SILENCER - AIR
DOES NOT ESTABLISH
FLUE
DOES NOT ESTABLISH
FAN AND BURNER ASSEMBLY
HW TOO HOT
SENSOR - DHW
F12 FAULT CODE
SENSOR - DHW
A06 FAULT CODE
PIPE - INTERNAL - CONDENSATE
A06 FAULT CODE
GAS INLET PRESSURE
A06 FAULT CODE
SILENCER - AIR
A06 FAULT CODE
FLUE
UP TO TEMP RADS COLD
PACK - ISOLATION VALVES (FLOW AND RETURN)
UP TO TEMP RADS COLD
PUMP ASSEMBLY
RADS FAIL TO REACH SET TEMP
THERMOSTAT - COMBINED
HEAT EXCHANGER KETTLES
PUMP ASSEMBLY
HEAT EXCHANGER KETTLES
VALVE - BYPASS
DHW COOL RADS COOL
EXTERNAL MIXING
DHW COOL RADS COOL
SENSOR - DHW
PCB FAULT CODES
PCB
PARAMETERS
Z DIRECTION CHOICE OR CONTINUE
F37
SYSTEM PRESSURE
FAULT CODE F47
PRESSURE GAUGE
FAULT CODE F37
PARAMETER WATER PRESSURE PROTECTION - B03
NO PRESSURE DROP
SILENCER - AIR
DOES NOT IGNITE
INJECTOR
NOT LIGHTING
ELECTRODE C/W LEAD
BURNER DOES NOT IGNITE
INJECTOR
BAFFLING
FAN AND BURNER ASSEMBLY
BAFFLES OR NOISY
INJECTOR
DOES NOT ESTABLISH
ELECTRODE C/W LEAD
DOES NOT ESTABLISH
INJECTOR
A06 ERROR CODE
FAN AND BURNER ASSEMBLY
FAULT CODE A06
INJECTOR
SHORTING
PUMP ASSEMBLY
APPLIANCE TO TEMP RADS COOL OR DO NOT HEAT
SYSTEM PRESSURE
NOT FITTED CORRECTLY
SENSOR FITMENT
OVERHEAT
SENSOR C/W BRACKET 10K NTC
OVERHEAT
THERMOSTAT - COMBINED
BLOCKED NOT SHOWING PRESSURE
PRESSURE GAUGE
FULLY OR PARTIALLY CLOSED - OVERHEAT
PACK - ISOLATION VALVES (FLOW AND RETURN)
NOT FITTED CORRECTLY F42
SENSOR FITMENT
OVERHEAT F42
SENSOR C/W BRACKET 10K NTC
FULLY OR PARTIALLY CLOSED - OVERHEAT F42
PACK - ISOLATION VALVES (FLOW AND RETURN)
BLOCKED NOT SHOWING PRESSURE F42
PRESSURE GAUGE
PASSING CAUSING A02
GAS VALVE
A02 FAULT CODE
GAS VALVE
A02 FAULT CODE
ELECTRODE C/W LEAD
BLOCKED NOT SHOWING PRESSURE FLUE OVERHEAT
PRESSURE GAUGE
NOT FITTED CORRECTLY FLUE OVERHEAT
SENSOR FITMENT
FLUE OVERHEAT
SENSOR - HEAT EXCHANGER
OVERHEAT FLUE OVERHEAT
SENSOR C/W BRACKET 10K NTC
CAUSING OVERHEAT FLUE OVERHEAT
PUMP ASSEMBLY
FLUE OVERHEAT
FLUE
DAMAGED FLUEWAYS CAUSING FLUE OVERHEAT
HEAT EXCHANGER FLUEWAYS
EXPLOSIVE IGNITION
PARAMETER IGNITION LEVEL - P01
EXPLOSIVE IGNITION
SILENCER - AIR
EXPLOSIVE IGNITION
FAN AND BURNER ASSEMBLY
EXPLOSIVE IGNITION 1
ELECTRODE C/W LEAD
EXPLOSIVE IGNITION
INJECTOR
EXPLOSIVE IGNITION
GAS INLET PRESSURE
RADS FAIL TO REACH SET TEMP
SENSOR C/W BRACKET 10K NTC
APPLIANCE AND RADS FAIL TO REACH SET TEMP
PARAMETER CH MAX OUTPUT - P13
DHW COOL RADS COOL
GAS INLET PRESSURE
POOR HW TEMP
PARAMETER DHW MAX OUTPUT - P20
PUMP DOES NOT RUN CH DEMAND
HARNESS X2 / X3
TRANSPARENT PARAMETERS
Z DIRECTION CHOICE OR CONTINUE
HOW TO ACTIVATE TEST MODE
Z DIRECTION CHOICE OR CONTINUE
FAULT CODE F47
PARAMETER WATER PRESSURE PROTECTION - B03
AC SECTION SHORTING
FAN AND BURNER ASSEMBLY
A41 FAULT CODE
SENSOR FITMENT
FLUE THERMISTOR FAULT CODE
HARNESS X2 / X3
TURBINE
HARNESS X2 / X3
FAN DOES NOT RUN
SENSOR - DHW
FAN DOES NOT RUN
THERMOSTAT - COMBINED
FAN AC SECTION
HARNESS X2 / X3
FAN DC SECTION
HARNESS X2 / X3
FAN FAULT CODE
PCB
FAN ERROR CODE
FAN PCB
FAN RUNNING CONTINUOUSLY
FAN PCB
FAN RUNS CONTINUOUSLY
HARNESS X2 / X3
FAULT CODE
SENSOR C/W BRACKET 10K NTC
RESISTANCE INCORRECT
GAS VALVE
CH NOT RECOGNISED
HARNESS X4
CH NOT RECOGNISED
HARNESS X1
NOT SWITCHING
INTEGRAL TIMER
PUMP DOES NOT RUN F43
HARNESS X2 / X3
PUMP DOES NOT RUN A03
HARNESS X2 / X3
FAN DOES NOT RUN
SENSOR C/W BRACKET 10K NTC
USER DISPLAY GUIDE
Z DIRECTION CHOICE OR CONTINUE
PARAMETER INFO
Z DIRECTION CHOICE OR CONTINUE
DHW COOL RADS COOL
INJECTOR
POOR HW OUTPUT
FAN AND BURNER ASSEMBLY
OVERHEAT FLUE OVERHEAT
THERMOSTAT - COMBINED
PUMP DOES NOT RUN F07
HARNESS X2 / X3
DHW COOL RADS COOL
FLUE
POOR HW OUTPUT
SILENCER - AIR
CORRECTLY ACTIVATED APPLIANCE COLD
FROST PROTECTION
APPLIANCE FAILS TO REACH SET TEMP
SYSTEM PRESSURE
RADS FAIL TO REACH SET TEMP
AIR IN APPLIANCE / SYSTEM
A03 FAULT CODE
SYSTEM PRESSURE
A03 OVERHEAT
AIR IN APPLIANCE / SYSTEM
F07 FAULT CODE
SYSTEM PRESSURE
F07 OVERHEAT
AIR IN APPLIANCE / SYSTEM
F43 FAULT CODE
SYSTEM PRESSURE
F43 OVERHEAT
AIR IN APPLIANCE / SYSTEM
UP TO TEMP RADS COLD
AIR IN APPLIANCE / SYSTEM
APPLIANCE RACHES TEMP RADS COOL
PRESSURE GAUGE
HEAT EXCHANGER KETTLES
AIR IN APPLIANCE / SYSTEM
CH KETTLING
SYSTEM PRESSURE
CH KETTLING
PRESSURE GAUGE
DHW KETTLING
SYSTEM PRESSURE
DHW KETTLING
PRESSURE GAUGE
FIRING WITH NO DEMAND
SENSOR - DHW
FIRING WITH NO DEMAND
THERMOSTAT - COMBINED
FLOW THERMISTOR FAULT CODE F42
HARNESS X2 / X3
FLOW THERMISTOR FAULT CODE
HARNESS X2 / X3
FAULT CODE A41
HARNESS X2 / X3
FAN DOES NOT RUN
EXTERNAL PROBE LINK
FAN DOES NOT RUN
SENSOR - HEAT EXCHANGER
FAN AC SECTION SHORTING
HARNESS X2 / X3
SHORTED
INTEGRAL TIMER
TURBINE HARNESS SHORTED
HARNESS X2 / X3
UP TO TEMP RADS COLD
VALVE - BYPASS
A03 OVERHEAT INVESTIGATION
VALVE - BYPASS
CAUSING OVERHEAT
PUMP ASSEMBLY
F42 INVESTIGATION
VALVE - BYPASS
CAUSING OVERHEAT F42
PUMP ASSEMBLY
A44 DHW SENSOR
SENSOR FITMENT
A44
SENSOR - DHW
POOR HW
SENSOR FITMENT
APPLIANCE FAIL TO REACH SET TEMP
PRESSURE GAUGE
F50
PARAMETER VARIABLE INPUT SWITCH
A03 FAULT CODE
SENSOR - DHW
FAN NOT RUNNING
EXTERNAL PROBE LINK
BLANK FOR CASE OFF
Z DIRECTION CHOICE OR CONTINUE
FAN DC SECTION 2
HARNESS X2 / X3
BLANK FOR TYPE OF DIAGNOSTIC PROCEDURE
Z DIRECTION CHOICE OR CONTINUE
POOR DHW FLOW
FILTER - FLOW METER - DHW
POOR DHW FLOW
RESTRICTOR - FLOW
RESTRICTED BLOCKED OR JAMMED
FLOW METER
BLANK FOR FAULT CODES
Z DIRECTION CHOICE OR CONTINUE
OPEN OR PASSING ALLOWING FLOW
HOT WATER OUTLETS
REGISTERING DEMAND WHEN NONE PRESENT
FLOW METER
BLANK FOR MAINS FUSE INVESTIGATION
Z DIRECTION CHOICE OR CONTINUE
BLOWN THROUGH FATIGUE
FUSE F1
SHORTED
FAN AND BURNER ASSEMBLY
DISPLAY JUMBLED
PCB
NOT RUNNING
PUMP ASSEMBLY
EXPANSION VESSEL PIPE
PIPE - BYPASS / EXPANSION VESSEL
DROPPING AWAY COMPLETELY
GAS INLET PRESSURE
INCORRECT SPARK GAP
ELECTRODE C/W LEAD
CAUSING NO IGNITION
FAN AND BURNER ASSEMBLY
DOES NOT IGNITE
PCB
HARNESS GONE DAMAGED PCB
PCB AND HARNESS X4
NOT OPENING
GAS VALVE
NO PRESSURE DROP
HEAT EXCHANGER FLUEWAYS
NO PRESSURE DROP
FAN AND BURNER ASSEMBLY
NO PRESSURE DROP 1
FAN AND BURNER ASSEMBLY
DOES NOT ESTABLISH
HEAT EXCHANGER FLUEWAYS
DOES NOT ESTABLISH 1
ELECTRODE C/W LEAD
DOES NOT ESTABLISH 1
FAN AND BURNER ASSEMBLY
F12 FAULT CODE
PCB
F12 FAULT CODE
HARNESS X2 / X3
POOR FLOW RATE
HEAT EXCHANGER (FLOW RATE)
HEAT EXCHANGER KETTLES (CH)
HEAT EXCHANGER WATERWAYS
DHW COOL RADS COOL
HEAT EXCHANGER WATERWAYS
DHW COOL RADS COOL
HEAT EXCHANGER FLUEWAYS
DHW COOL RADS COOL
FAN AND BURNER ASSEMBLY
DOES NOT IGNITE
HEAT EXCHANGER FLUEWAYS
WRONG MIX NOT IGNITING
GAS VALVE
WRONG MIX BAFFLING
GAS VALVE
BAFFLING
HEAT EXCHANGER FLUEWAYS
DAMAGED CAUSING BAFFLING
FAN AND BURNER ASSEMBLY
A02 FAULT
GAS VALVE
A06 FAULT CODE
HEAT EXCHANGER FLUEWAYS
A06 FAULT CODE
FAN AND BURNER ASSEMBLY
RETEST APPLIANCE OPERATION - PCB FAULT
FAULT CODE RESET
FAULT CODE F37
PCB
FAULT CODE F37
HARNESS X4
FAULT CODE F37
PRESSURE SWITCH - LOW WATER
F37
PRESSURE SWITCH - LOW WATER
FAULT CODE F37
PUMP MANIFOLD
PUMP SECTION SHORTING
HARNESS X2 / X3
OVERHEAT 2
OVERHEAT - PCB
EXPLOSIVE IGNITION
GAS VALVE
EXPLOSIVE IGNITION
ELECTRODE C/W LEAD
EXPLOSIVE IGNITION 1
FAN AND BURNER ASSEMBLY
PUMP DOES NOT RUN CH DEMAND
PUMP ASSEMBLY
FAULT CODE F47
PCB
FAN STUCK
FAN AND BURNER ASSEMBLY
RESISTANCES INCORRECT
FAN AND BURNER ASSEMBLY
FAN FAULT CODE
FAN ELECTRICAL CONNECTIONS
FAULT CODE A41
PCB
FAULT CODE
SENSOR - HEAT EXCHANGER
NOT RECOGNISING DEMAND
FLOW METER
FAN FAULT CODE
FAN PCB
RETURN THERMISTOR FAULT CODE
HARNESS X4
GAS VALVE SECTION A62 FAULT CODE
HARNESS X4
CH DEMAND NOT RECOGNISED
HARNESS X4
NOT RUNNING F43
PUMP ASSEMBLY
NOT RUNNING A03
PUMP ASSEMBLY
NOT RUNNING F07
PUMP ASSEMBLY
NOISY OPERATION DHW
HEAT EXCHANGER WATERWAYS
SHORTED
FLOW METER
FAULT CODE F42
THERMOSTAT - COMBINED
FAULT CODE
THERMOSTAT - COMBINED
FAULT CODE A41
THERMOSTAT - COMBINED
A06 FAULT CODE
ELECTRODE C/W LEAD
PCB TAKING OUT FUSES
PCB - FUSE
SHORTED
HARNESS X1
BOILER REACHES TEMP RADS DO NOT
SYSTEM BLOCKAGE
OVERHEAT F42
OVERHEAT - PCB
A44
PCB
F50
PCB
A03
OVERHEAT - PCB
FAN NOT RUNNING
HARNESS X4
FILTER RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION FLOW METER, FILTER AND RESTRICTOR
FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FLOW METER, FILTER AND RESTRICTOR
FLOW TURBINE RESTRICTED / BLOCKED OR JAMMED
CHARACTERISTIC TEST FROM INSPECTION FLOW METER, FILTER AND RESTRICTOR
FAULT CODE SHOWN
CHARACTERISTIC TEST FROM OBSERVATION APPLIANCE SELF CHECK
APPLIANCE ATTEMPTS TO FIRE WHEN SELF CHECK COMPLETE
CHARACTERISTIC TEST FROM OBSERVATION APPLIANCE SELF CHECK
FAN DOES NOT STOP WHEN SELF CHECK COMPLETE
CHARACTERISTIC TEST FROM OBSERVATION APPLIANCE SELF CHECK
DISPLAY DOES NOT OPERATE
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATION
DISPLAY OPERATES BUT IS JUMBLED OR DISTORTED
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATION
FAN BEHAVES AS DESCRIBED ABOVE BUT PUMP DOES NOT PULSE AS DESCRIBED
CHARACTERISTIC TEST FROM OBSERVATION APPLIANCE SELF CHECK
FAN BEHAVES AS DESCRIBED ABOVE BUT PUMP RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM OBSERVATION APPLIANCE SELF CHECK
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CH
INLET PRESSURE SATISFACTORY BUT DOES NOT DIP DURING SPARKING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
INLET PRESSURE LOW OR DIES AWAY DURING IGNITION
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
ELECTRDOE GAP TO BURNER SURFACE INCORRECT
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
AIR / GAS MIXER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION AIR / GAS MIXER, BURNER AND HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
ELECTRODE GAP TO BURNER SURFACE INCORRECT
CHARACTERISTIC TEST FROM INSPECTION AIR / GAS MIXER, BURNER AND HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
RADIATORS HEAT BUT HEAT EXCHANGER IS NOISY (KETTLES)
CHARACTERISTIC TEST FROM OPERATION CH
DHW COOL, RADIATORS COOL
CHARACTERISTIC TEST FROM OPERATION DHW
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
LOW WATER PRESSURE SWITCH BLOCKED
CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SWITCH AND MANIFOLD
PUMP MANIFOLD BLOCKED
CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SWITCH AND MANIFOLD
BURNER IGNITES BUT LIGHTS WITH EXPLOSIVE IGNITION
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
ELECTRODE GAP TO BURNER SURFACE INCORRECT
CHARACTERISTIC TEST FROM INSPECTION AIR / GAS MIXER, BURNER AND HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND / OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
DHW COOL, PUMP RUNS AND RADIATORS HEAT
CHARACTERISTIC TEST FROM OPERATION DHW
HEAT EXCHANGER NOISY (KETTLES) DURING OPERATION
CHARACTERISTIC TEST FROM OPERATION DHW
FAN FREE TO ROTATE
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION AND RESISTANCE
FAN RESISTANCES NOT AS EXPECTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION AND RESISTANCE
POOR ELECTRICAL CONNECTION BETWEEN FAN PCB AND FAN MOTOR
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION AND RESISTANCE
ELECTRODE GAP TO BURNER SURFACE INCORRECT
CHARACTERISTIC TEST FROM INSPECTION AIR / GAS MIXER, BURNER AND HEAT EXCHANGER FLUEWAYS
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
APPLIANCE REACHES TEMP RADIATORS REMAIN COOL OR DO NOT HEAT
CHARACTERISTIC TEST FROM OPERATION CH
APPLIANCE AND RADIATORS FAIL TO REACH SET TEMPERATURE
CHARACTERISTIC TEST FROM OPERATION CH
05/10/2021 14:08:23 2108_1_10_1 10/11/2021 16:02:20
07/10/2021 10:47:36
WATER SUPPLY TO PREMISES
TURN ON A COLD WATER TAP
OBSERVATION ISOLATE DHW DOES DEMAND STOP
ISOLATE THE DHW SUPPLY TO THE APPLIANCE ON THE
ISOLATING VALVE UNDERNEATH THE APPLIANCE
VOLTAGE DC FROM TURBINE (FIRING WITH NO DEMAND)
{GAINPCBACS}
RESISTANCE FUSE MAINS
REMOVE FUSE FROM FUSED SPUR OR PLUG
RESISTANCE ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM COMBUSTION DOOR
DISCONNECT IGNITION LEAD FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE THE CONNECTOR FROM THE GAS VALVE
RESISTANCE DHW SENSOR AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE THE LEADS FROM THE LOW WATER PRESSURE SWITCH (ORANGE LEADS)
INSPECTION WATER PRESSURE SWITCH AND MANIFOLD
APPLIANCE DRAINED AND DISCHARGED
REMOVE THE WATER PRESSURE SWITCH FROM THE PUMP MANIFOLD
RESISTANCE PUMP - FUSE INVESTIGATION
REMOVE THE PUMP CONNECTOR
OBSERVATION BOILER RECOGNISES DEMAND (EXT CONTROLS LINKED OUT)
REMOVE ALL EXTERNAL
RESISTANCE HARNESS EXTERNAL CONTROLS
REMOVE CONNECTOR X4 FROM THE PCB
RESISTANCE FLOW SENSOR / OVERHEAT STAT HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FLOW SENSOR / OVERHEAT STAT
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE FLOW SENSOR / OVERHEAT STAT HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FLOW SENSOR / OVERHEAT STAT
VOLTAGE DC TURBINE - DEMAND
{GAINPCBACS}
VOLTAGE DC TURBINE - SEND
ENSURE NO DEMANDS
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
VOLTAGE INTEGRAL TIMER
{GAINPCBACS}
RESISTANCE INTEGRAL TIMER
DISCONNECT THE TWO LEADS FROM TERMINALS 3 AND 4 ON THE CLOCK
CLOCK SWITCHED ON
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE DC TURBINE - SEND (TURBINE DISCONNECTED)
ENSURE NO DEMANDS
REMOVE THE CONNECTOR FROM THE FLOW TURBINE AND MAKE SAFE
RESISTANCE INTEGRAL TIMER - FUSE INVESTIGATION
DISCONNECT THE LEADS FROM TERMINALS 1 AND 2 ON THE CLOCK MOTOR
RESISTANCE HARNESS TURBINE
REMOVE THE CONNECTOR FROM THE FLOW TURBINE
OBSERVATION FAN RUNNING
NO DEMANDS
OBSERVATION FAN ROTATION AND RESISTANCE
REMOVE THE PCB FROM THE FAN ASSEMBLY
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE FLOW SENSOR / OVERHEAT STAT HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FLOW SENSOR / OVERHEAT STAT
RESISTANCE EXHAUST TEMPERATURE SENSOR AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS EXHAUST TEMPERATURE SENSOR
REMOVE THE SILENCER
SOCKET AND SEE TEST
{GAINPCBACS}
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE THE CONNECTOR FROM THE GAS VALVE
RESISTANCE PUMP AND HARNESS - FUSE INVESTIGATION
REMOVE CONNECTOR X2 FROM THE PCB
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
RESISTANCE ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM COMBUSTION DOOR
DISCONNECT IGNITION LEAD FROM THE PCB
INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
REMOVE BURNER DOOR ASSEMBLY
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
INSPECTION FLOW METER ASSEMBLY
ISOLATE THE COLD WAT
PRESSURE GAS INLET DROP
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
OBSERVATION SPARKING OCCURS
DISCONNECT THE IGNIT
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION SILENCER
REMOVE THE SILENCER
OBSERVATION REMOVE EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
TEMPERATURE PRIMARY HEAT EXCHANGER
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE, AS CLOSE TO THE FLOW SENSOR / STAT AS POSSIBLE
RESISTANCE HARNESS FAN DC
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE PCB MAINS INPUT
{GAINPCBACS}
RESISTANCE FUSE F1
REMOVE THE FUSE FROM THE PCB
OBSERVATION DISCONNECT X3
DISCONNECT CONNECTOR X3 FROM THE PCB AND MAKE SAFE
RESISTANCE HARNESS FAN DC
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE HARNESS PUMP
REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
INSPECTION SILENCER
REMOVE THE SILENCER
PRESSURE EXPANSION VESSEL
APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED
VOLTAGE DC TO GAS VALVE AT PCB
{GAINPCBACS}
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM THE GAS VALVE
INSPECTION SILENCER
REMOVE THE SILENCER
INSPECTION AIR / GAS MIXER, BURNER AND HEAT EXCHANGER FLUEWAYS
REMOVE BURNER DOOR ASSEMBLY
INSPECTION SILENCER
REMOVE THE SILENCER
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
RESISTANCE ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM COMBUSTION DOOR
DISCONNECT IGNITION LEAD FROM THE PCB
INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
REMOVE BURNER DOOR ASSEMBLY
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION SILENCER
REMOVE THE SILENCER
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
INSPECTION BURNER, HEAT EXCHANGER FLUEWAYS AND ELECTRODE
REMOVE BURNER DOOR ASSEMBLY
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
PRESSURE GAS INLET (DHW TOO COOL)
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION BURNER AND HEAT EXCHANGER FLUEWAYS
REMOVE BURNER DOOR ASSEMBLY
INSPECTION BURNER AND HEAT EXCHANGER FLUEWAYS
REMOVE BURNER DOOR ASSEMBLY
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
RESISTANCE FAN - FUSE INVESTIGATION
REMOVE THE FAN PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
OBSERVATION PUMP RUNNING FOR OVERHEAT
ENSURE APPLIANCE IS COOL
OBSERVATION BOILER RECOGNISES DEMAND (EXT CONTROLS LINKED OUT)
REMOVE ALL EXTERNAL
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
OBSERVATION PUMP RUNNING FOR OVERHEAT
ENSURE APPLIANCE IS COOL
PRESSURE STANDING RETURN
ATTACH PRESSURE GAUG
RESISTANCE ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM COMBUSTION DOOR
DISCONNECT IGNITION LEAD FROM THE PCB
RESISTANCE EXHAUST TEMPERATURE SENSOR AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION PRIMARY HEAT EXCHANGER FLUEWAYS
REMOVE BURNER DOOR ASSEMBLY
OBSERVATION SPARKING OCCURS
DISCONNECT THE IGNIT
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION SILENCER
REMOVE THE SILENCER
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
RESISTANCE ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM COMBUSTION DOOR
DISCONNECT IGNITION LEAD FROM THE PCB
INSPECTION INJECTOR
UNDO THE TOP NUT OF THE GAS VALVE, SWING PIPE AROUND AND REMOVE THE INJECTOR
INSPECTION BURNER AND SPARK GAP
REMOVE BURNER DOOR ASSEMBLY
RESISTANCE HARNESS PUMP
REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY
RESISTANCE FAN HARNESS - FUSE INVESTIGATION
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE HARNESS FAN AC
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS TURBINE
REMOVE THE CONNECTOR FROM THE FLOW TURBINE
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE RETURN SENSOR
REMOVE THE LEADS FROM THE RETURN SENSOR (GREEN LEADS)
RESISTANCE HARNESS FAN DC
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE DC FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
VOLTAGE DC FROM FAN HALL SENSOR
{GAINPCBACS}
REMOVE FAN PCB COVER IF REQUIRED
RESISTANCE INTEGRAL TIMER AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
ENSURE CH CONTROLS ARE CALLING FOR HEAT
CLOCK SWITCHED TO ON
RESISTANCE HARNESS PUMP
REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY
RESISTANCE HARNESS PUMP
REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY
RESISTANCE EXHAUST TEMPERATURE SENSOR AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION AIR / GAS MIXER
REMOVE THE INSPECTION COVER FROM THE AIR / GAS MIXER ASSEMBLY
OBSERVATION PUMP RUNNING FOR OVERHEAT
ENSURE APPLIANCE IS COOL
RESISTANCE HARNESS PUMP
REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY
INSPECTION SILENCER
REMOVE THE SILENCER
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
RESISTANCE FLOW SENSOR / STAT COMBINED AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE EXTERNAL PROBE LINK AND HARNESS
REMOVE CONNECTOR X4 FROM THE PCB
RESISTANCE INTEGRAL TIMER AND HARNESS - FUSE INVESTIGATION
REMOVE CONNECTOR X1 FROM THE PCB
INSPECTION INTERNAL BYPASS - OVERHEAT
APPLIANCE DRAINED AND DISCHARGED
REMOVE THE INTERNAL BYPASS VALVE
INSPECTION INTERNAL BYPASS - OVERHEAT
APPLIANCE DRAINED AND DISCHARGED
REMOVE THE INTERNAL BYPASS VALVE
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
RESISTANCE DHW SENSOR
REMOVE THE LEADS FROM THE DHW SENSOR (BLUE LEADS)
VOLTAGE DC FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
RESISTANCE HARNESS FAN DC
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE DC FAN AT PCB
{GAINPCBACS}
REMOVE THE CONNECTOR FROM THE FAN ASSEMBLY AND MAKE SAFE
VOLTAGE DC FROM FAN HALL SENSOR
{GAINPCBACS}
REMOVE FAN PCB COVER IF REQUIRED
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
System Information
- Total Tests: 579
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control