Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach pressure gauge to the inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Cancel purge cycle.
Allow ignition sequence to commence.
Monitor the inlet pressure throughout the ignition sequence.
Does the pressure gauge show an acceptable minimum
gas inlet pressure throughout its operation ?
Note.
When pressure gauge is removed test point should be tightened and checked for gas tightness.