Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the pump connector

Measurement:

Test 1.
Measure the resistance between the Live and Neutral pins on the pump.
Expected resistance as per table below:
ApplianceResistance Ohms (approx)
Modena 25C292
Modena 27C 292
Modena 30C228
Modena 32C228
Ferroli T-ONE 25C292
Ferroli T-ONE 30C228

Test 2.
Measure the resistance between either the Live or Neutral pin on the pump to the Earth pin.
Expected resistance greater than 1Mohm.
Note.
A reading of O.L on test 2 is acceptable as this is greater than 1 MOhm.