Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the fan assembly
Remove connector X2 from the PCB
Remove connector X2 from the PCB
Measurement:
Test 1.
Measure the resistance between pin 4 (green) on
connector X2 to pin 2 (green) on the fan connector.
Test 2.
Measure the resistance between pin 10 (green) on
connector X2 to pin 3 (green) on the fan connector.
Test 3.
Measure the resistance between pin 1 (earth) on
the fan connector to a suitable earth point.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness and the connectors.
Measure the resistance between pin 4 (green) on
connector X2 to pin 2 (green) on the fan connector.
Test 2.
Measure the resistance between pin 10 (green) on
connector X2 to pin 3 (green) on the fan connector.
Test 3.
Measure the resistance between pin 1 (earth) on
the fan connector to a suitable earth point.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness and the connectors.

Isolate as per TOPs P4
and refit as necessary