VAILLANT VCW GB 282 EH

GLOBALLY REPLACED

Next: &13, *

CENTRAL HEATING

HEATING SWITCH ON
ROOM STAT CALLING FOR HEAT
RADIATOR VALVES OPEN

Next: &707, f667

DIVERTER VALVE CH MODE

HEATING SWITCH ON
ROOM STAT CALLING FOR HEAT

Next: &1, f219

SERVO VALVE CENTRAL HEATING MODE

HEATING SWITCH ON
SYSTEM CALLING FOR HEAT

Next: &2, f607

HIGH FLAME

HEATING SWITCH OFF
ATTACH PRESSURE GAUGE TO BURNER PRESSURE TEST POINT

Next: &437, ?473, ?475

LOW FLAME TEST

HEATING SWITCH OFF

Next: &5, ?62, ?64, ?66, ?512

FAN RUNNING

HEATING SWITCH OFF

Next: &294, f44

DIVERTER VALVE

HEATING SWITCH OFF

Next: &9, f29

OPERATION SERVO VALVE CAM

HEATING SWITCH OFF

Next: &642, ?23, ?25

MAINS SUPPLY TO BOILER

HEATING SWITCH OFF
(BOTH ON CONTROL PANEL)

Next: &11, f16

VAILLANT VCW GB 282 EH

G.C. NUMBER 47 044 1

Next: &12, !f161

YELLOW NEON CHECK

HEATING SWITCH OFF

Next: &7, f295

HOT WATER

HEATING SWITCH OFF

Next: &3, ?670, ?672

RESISTANCE DHW MICROSWITCH

REMOVE ONE OF THE WIRES FROM THE DHW MICROSWITCH

Next: &10, !f643

OPERATION PUMP AND FAN OVERRUN

Next: &nff, ?708, ?710

FUSE F2 2A

SET - 10 OFF FUSES 2.0AT

Next: End

CH OVERHEAT THERMOSTAT

TEMPERATURE LIMITER

Next: End

DIFFERENTIAL VALVE

DIFFERENTIAL PRESSURE VALVE

Next: End

SPARKING HEARD

PCB - FLAME FAILURE DEVICE - IGNITION

Next: End

DIVERTER VALVE

CONTROL LINE

Next: End

ELECTRICAL SAFETY CHECKS

ELECTRICAL SAFETY CHECKS

Next: End

FUSE F1 2A

SET - 10 OFF FUSES 2.0AT

Next: End

EXTERNAL FAULT

Next: End

DHW THERMOSTAT

TEMPERATURE LIMITER

Next: End

NTC RESISTOR

SENSOR - NTC

Next: End

YELLOW NEON CHECK

WIRE - NTC CONNECTION

Next: End

MICROSWITCH M1

MICROSWITCH ASSEMBLY

Next: End

YELLOW NEON

PCB - FLAME FAILURE DEVICE - IGNITION

Next: End

YELLOW NEON TEST

ELECTRODES (SENSING AND SPARK)

Next: End

DIVERTER VALVE CH

CONTROL LINE

Next: End

PUMP

PUMP 230V 6M

Next: End

FAN RUNNING

PCB - FAN CIRCUIT

Next: End

EXTERNAL CONTROLS

Next: End

ELECTRONIC PCB

PCB - ELECTRONIC CONTROL SYSTEM

Next: End

DHW MODULATES MODULATES QUICKLY

SENSOR - NTC

Next: End

DHW MODULATES MODULATES QUICKLY

TEMPERATURE LIMITER

Next: End

HOT WATER

ELECTRODES (SENSING AND SPARK)

Next: End

STICKING PREVENTING MOVEMENT

SPINDLE AND SUPPORT PLATE

Next: End

STICKING NOT RETURNING

SPINDLE AND SUPPORT PLATE

Next: End

WATER SECTION SPRING DISCONNECTED

SERVO VALVE

Next: End

CH OPERATION

CONTROL LINE

Next: End

CH OPERATION 2

CONTROL LINE

Next: End

DIVERTER VALVE 2

CONTROL LINE

Next: End

LEAKING PREVENTING HIGH FLAME

BANJO CONNECTOR

Next: End

HOSE CONNECTION

TUBES TO DIAPHRAGM PUMP

Next: End

NO POWER TO APS

PCB - FAN CIRCUIT

Next: End

YELLOW NEON

AIR PRESSURE MONITOR

Next: End

YELLOW NEON

HOSE SILICONE RUBBER

Next: End

FLUEWAYS

PRIMARY HEAT EXCHANGER

Next: End

MICROSWITCH M3

MICROSWITCH M3

Next: End

OVERHEAT THERMOSTAT

OVERHEAT CUT - OFF DEVICE

Next: End

FUSE F3 160MA

PACK - 10 OFF FUSE 0.16AT

Next: End

PREVENTING DIVERTER MOVEMENT

SYSTEM PRESSURE / AIR

Next: End

PREVENTING DIVERTER MOVEMENT 2

SYSTEM PRESSURE / AIR

Next: End

PREVENTING GAS VALVE OPERATOR MOVING

SYSTEM PRESSURE / AIR

Next: End

MICROSWITCH M2

MICROSWITCH ASSEMBLY

Next: End

CONTROL BOX CLICKS, NO SPARKING HEARD FROM ELECTRODE

ELECTRODES (SENSE & SPARK)

Next: End

CH OPERATION ON HW TREE

CONTROL LINE

Next: End

DHW MODULATES POOR DHW

SENSOR - NTC

Next: End

DHW MODULATES POOR DHW

TEMPERATURE LIMITER

Next: End

STUCK ON

Next: End

HIGH FLAME

GAS PRESSURE GOVERNOR

Next: End

RESTRICTED OR BLOCKED

INJECTORS

Next: End

LOW FLAME TEST (1)

PCB - FLAME FAILURE DEVICE - IGNITION

Next: End

FLUE

FLUE

Next: End

BLOCKED / RESTRICTED

ORIFICE / BUSHES

Next: End

MAINS SUPPLY TO BOILER

PCB

Next: End

DIVERTER VALVE

TRANSFORMER

Next: End

LOW FLAME TEST

ELECTRODES (SENSING AND SPARK)

Next: End

NO SPARKING HEARD

ELECTRODES (SENSE & SPARK)

Next: End

SPARKING HEARD

GAS PRESSURE GOVERNOR

Next: End

YELLOW NEON CHECK

TRANSFORMER - IGNITION

Next: End

CH

Next: End

DIVERTER VALVE CENTRAL HEATING MODE

DIVERTER VALVE OR PARTS

Next: End

FAN

FAN

Next: End

CH DEMAND

PCB

Next: End

DHW MODULATES MODULATES QUICKLY

HEAT EXCHANGER - SECONDARY - DHW

Next: End

BOILER MODULATES MODULATES QUICKLY

PRIMARY HEAT EXCHANGER

Next: End

BOILER MODULATES MODULATES QUICKLY

MICROSWITCH ASSEMBLY

Next: End

DHW MODULATES MODULATES QUICKLY

PCB - ELECTRONIC CONTROL SYSTEM

Next: End

HOT WATER

PCB - FLAME FAILURE DEVICE - IGNITION

Next: End

NOT RETURNING

SERVO VALVE

Next: End

CAM NOT MOVING FULLY OVER

WATER VALVE

Next: End

SPINDLE REMAINS UP

WATER VALVE

Next: End

SERVO VALVE

SERVO VALVE

Next: End

DIVERTER VALVE

DIVERTER VALVE OR PARTS

Next: End

DIAPHRAGM PUMP

DIAPHRAGM PUMP

Next: End

YELLOW NEON

FAN

Next: End

NOT FIRING FOR CH

PCB - ELECTRONIC CONTROL SYSTEM

Next: End

DHW MODULATES

HEAT EXCHANGER - SECONDARY - DHW

Next: End

BOILER MODULATES

PRIMARY HEAT EXCHANGER

Next: End

SERVO VALVE BOILER MODULATES

SERVO VALVE

Next: End

BOILER MODULATES

MICROSWITCH ASSEMBLY

Next: End

FAULTY OVERRUN FUNCTION

PCB

Next: End

ON WITH NO DEMAND

PCB

Next: End

DHW MODULATES POOR DHW

PCB - ELECTRONIC CONTROL SYSTEM

Next: End

BLANK FOR LED INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

DIVERTER VALVE POOR DHW

DIVERTER VALVE OR PARTS

Next: End

DIVERTER VALVE (1)

PCB

Next: End

LOW FLAME TEST (2)

PCB - FLAME FAILURE DEVICE - IGNITION

Next: End

IGNITION TRANSFORMER

TRANSFORMER - IGNITION

Next: End

SERVO VALVE CAM DOES NOT MOVE FULLY OVER

CHARACTERISTIC TEST FROM OPERATION SERVO VALVE CAM

Next: p574

SERVO VALVE CAM DOES NOT FULLY RETURN OR ONLY RETURNS WHEN PRESSED

CHARACTERISTIC TEST FROM OPERATION SERVO VALVE CAM

Next: p589

BOILER DOES NOT GO TO HIGH FLAME

CHARACTERISTIC TEST FROM HIGH FLAME

Next: p477

BOILER GOES TO HIGH FLAME BRIEFLY THEN MODULATES QUICKLY OR CUTS OUT

CHARACTERISTIC TEST FROM HIGH FLAME

Next: p488

BOILER DOES NOT REACT TO CH DEMAND

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p493

DIFFERENTIAL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: !p495

BURNER IGNITES BUT SPARKING CONTINUES / LOCKOUT OCCURS

CHARACTERISTIC TEST FROM LOW FLAME TEST

Next: p514

CONTROL BOX CLICKS, BUT NO SPARKING HEARD AT ELECTRODE

CHARACTERISTIC TEST FROM LOW FLAME TEST

Next: p63

NO SPARKING HEARD

CHARACTERISTIC TEST FROM LOW FLAME TEST

Next: p65

SPARKING HEARD BUT BURNER DOES NOT IGNITE AND THEN LOCKS OUT

CHARACTERISTIC TEST FROM LOW FLAME TEST

Next: p151

INSUFFICIENT TEMPERATURE RISE - RADIATORS BEGIN TO HEAT WITH NO DEMAND

CHARACTERISTIC TEST FROM HOT WATER

Next: !p733

BOILER DOES NOT REACT TO CH DEMAND

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p679

DIFFERENTIAL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: !p681

PUMP OR FAN OVER RUN DO NOT BEHAVE AS DESCRIBED

CHARACTERISTIC TEST FROM OPERATION PUMP AND FAN OVERRUN

Next: !p709

BOILER STAYS ON WITH NO DEMAND

CHARACTERISTIC TEST FROM OPERATION PUMP AND FAN OVERRUN

Next: p711

FUSE F1 INTEGRITY CHECK

Next: p18, !f17

VOLTAGE PUMP AT PUMP

HEATING SWITCH OFF
REMOVE PUMP TERMINAL COVER

Next: p657, f222

VOLTAGE EXTERNAL CONTROLS OUT

{GAINPCBACS}
HEATING SWITCH ON

Next: !p471, f318

WATER PUMP VOLTAGE TEST

HEATING SWITCH OFF
REMOVE PUMP TERMINAL COVER

Next: p31, f645

VOLTAGE AIR PRESSURE SWITCH CHECK

APS IS LOCATED AT RE

Next: p296, f629

VOLTAGE EXTERNAL CONTROLS IN

{GAINPCBACS}
HEATING SWITCH ON

Next: !p319, !f472

FAN MAINS VOLTAGE CHECK

HEATING SWITCH OFF

Next: !p46, !f45

DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN EXITING THE BOILER AS INDICATED

Next: !p491, ?492, ?494

VOLTAGE PUMP AT PUMP

HEATING SWITCH OFF
REMOVE PUMP TERMINAL COVER

Next: p500, f501

VOLTAGE EXTERNAL CONTROLS OUT

{GAINPCBACS}
HEATING SWITCH ON

Next: !p502, f503

VOLTAGE EXTERNAL CONTROLS IN

{GAINPCBACS}
HEATING SWITCH ON

Next: !p504, !f505

INSPECTION SPINDLE AND SUPPORT PLATE

REMOVE THE SECURING

Next: !p600, !f597

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p602, !f603

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p608, !f609

VOLTAGE AIR PRESSURE SWITCH (IN)

ATTACH RED CROCODILE CLIP TO BROWN WIRE
ATTACH BLACK CROCODILE CLIP TO A SUITABLE EARTH POINT

Next: p631, !f630

OVERHEAT CUT-OFF DEVICE CHECK

REMOVE COVER FROM THE OVERHEAT CUT-OFF DEVICE
ENSURE APPLIANCE IS COOL

Next: p646, !f647

MICROSWITCHES M1 AND M2 CH OPERATION

REMOVE WIRES FROM DIVERTER MICROSWITCHES AND MAKE SAFE

Next: !p668, !f669

DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN EXITING THE BOILER AS INDICATED

Next: !p677, ?678, ?680

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p684, !f685

VOLTAGE PUMP AT PUMP

HEATING SWITCH OFF
REMOVE PUMP TERMINAL COVER

Next: p688, f689

VOLTAGE EXTERNAL CONTROLS OUT

{GAINPCBACS}
HEATING SWITCH ON

Next: !p690, f691

VOLTAGE EXTERNAL CONTROLS IN

{GAINPCBACS}
HEATING SWITCH ON

Next: !p692, !f693

OPERATOR DC VOLTAGE CHECK

{GAINPCBACS}
HEATING SWITCH OFF

Next: p73, !f72

CENTRAL HEATING OVERHEAT THERMOSTAT CHECK

HEATING SWITCH OFF

Next: p155, !f153

OPERATOR DC VOLTAGE CHECK

{GAINPCBACS}
HEATING SWITCH OFF

Next: p662, !f159

DIFFERENTIAL VALVE MOVEMENT CHECK

HEATING SWITCH OFF

Next: !p157, !f158

FUSE F2 INTEGRITY CHECK

Next: p20, !f100

EXTERNAL

{GAINPCBACS}
HEATING SWITCH OFF

Next: p729, !f21

OBSERVATION REMOVE WIRES FROM DHW OVERHEAT STAT

HEATING SWITCH OFF

Next: p306, !f307

NTC RESISTANCE CHECK

DISCONNECT THE NTC SENSOR FROM THE HARNESS

Next: p308, !f309

PUMP LIMPET TEST

Next: p650, !f41

MICRO SWITCHES M1 & M2 DOMESTIC HOT WATER OPERATION

REMOVE WIRES FROM DIVERTER VALVE MICROSWITCHES AND MAKE SAFE
HOT WATER TAP OFF

Next: p312, !f313

IGNITION TRANSFORMER VOLTAGE CHECK

HEATING SWITCH OFF

Next: p314, !f315

SPARK AND SENSE ELECTRODE CHECK

Next: !p316, !f317

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p322, !f323

GREEN NEON

HEATING SWITCH OFF

Next: p620, !f479

DIFFERENTIAL PLATE HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p489, f490

RESISTANCE NTC-RESISTOR AT SENSOR

DISCONNECT THE NTC SENSOR FROM THE HARNESS

Next: p508, !f509

SERVO VALVE CENTRAL HEATING MODE

HEATING SWITCH ON
SYSTEM CALLING FOR HEAT

Next: p496, f601

DIVERTER VALVE CH MODE

HEATING SWITCH ON
ROOM STAT CALLING FOR HEAT

Next: !p498, f499

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p506, !f507

DISCONNECT OVERHEAT STAT WIRES

HEATING SWITCH OFF

Next: !p510, !f511

SENSE ELECTRODE CHECK

Next: !p515, !f516

INSPECTION SPINDLE AND SUPPORT PLATE

REMOVE THE SECURING

Next: !p599, !f577

INSPECTION SPINDLE GAP

Next: !p588, f595

INSPECTION SERVO VALVE SPRING

Next: p575, !f598

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p619, !f612

INSPECTION BANJO CONNECTOR

Next: p621, !f622

FLAME MODULATION CHECK

ATTACH A PRESSURE GA

Next: p623, !f715

DIAPHRAGM PUMP TUBE (HOSE) CONNECTION

GAIN ACCESS TO THE TUBES RUNNING FROM THE OPERATOR TO THE DIAPHRAGM PUMP IN THE CONTROL BOX

Next: !p627, !f628

AIR (FAN) PRESSURE SWITCH CHECK

REMOVE THE AIR PRESSURE SWITCH FROM THE APPLIANCE

Next: p719, !f633

ORIFICE CHECK

Next: p634, !f728

INSPECTION APS TUBES

Next: p636, !f637

FUSE F3 INTEGRITY CHECK

Next: p734, !f649

IGNITION TRANSFORMER VOLTAGE CHECK

HEATING SWITCH OFF

Next: p71, f70

DIFFERENTIAL PLATE HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p675, f676

RESISTANCE NTC-RESISTOR AT SENSOR

DISCONNECT THE NTC SENSOR FROM THE HARNESS

Next: p696, !f697

SERVO VALVE CENTRAL HEATING MODE

HEATING SWITCH ON
SYSTEM CALLING FOR HEAT

Next: p682, f683

DIVERTER VALVE CH MODE

HEATING SWITCH ON
ROOM STAT CALLING FOR HEAT

Next: !p686, f687

CONTROL LINE BLOCKAGES

WATER OFF
BOILER DRAINED AND DISCHARGED

Next: !p694, !f695

DISCONNECT OVERHEAT STAT WIRES

HEATING SWITCH OFF

Next: p716, !f699

OBSERVATION DISCONNECT EXTERNAL CONTROLS

REMOVE WIRING FROM TERMINALS 3 AND 4 AND MAKE SAFE

Next: !p712, !f713

INSPECTION INJECTORS

Next: !p717, !f718

INSPECTION FLUE

Next: p632, !f727

SENSE ELECTRODE CHECK

Next: !p75, !f74

RESISTANCE TRANSFORMER

{GAINPCBACS}
REMOVE TRANSFORMER CONNECTOR FROM PCB

Next: !p735, !f736