Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
BAXI 100 HE
WARNING - IMPORTA
FAN RUNS
ENSURE BOILER IS COOL
DHW OPERATION
HW DEMAND
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
HOW TO SET MULTIMETER TO DIODE TEST
THE IMAGES BELOW SHO
FUSE INVESTIGATION TREE
OUTSIDE MODEL
OBSERVATION POWER LED
BOILER TEMPERATURE CONTROL SET TO OFF POSITION
FAULT CODE DRY FIRE
NOT USED
FAULT CODE SAFETY LOCKOUT
NOT USED
FAULT CODE IGNITION
NOT USED
OBSERVATION SPARKING CONFIRMATION
REMOVE THE TOP TWO S
EXPLOSIVE IGNITION
ELECTRODES
EXPLOSIVE IGNITION 4
ELECTRODES
EXPLOSIVE IGNITION 6
ELECTRODES
EXPLOSIVE IGNITION 1
ELECTRODES
EXPLOSIVE IGNITION 5
ELECTRODES
EXPLOSIVE IGNITION 7
ELECTRODES
NO SPARKING 2
ELECTRODES
NO SPARKING 3
ELECTRODES
EXPLOSIVE IGNITION
COMBUSTION SEALS
EXPLOSIVE IGNITION
HEAT EXCHANGER FLUE WAYS
EXPLOSIVE IGNITION
VENTURI
EXPLOSIVE IGNITION
BURNER ASSEMBLY
EXPLOSIVE IGNITION
FLUE
EXPLOSIVE IGNITION
PCB CONTROL JUMPER JP4
EXPLOSIVE IGNITION
HARNESS IGNITION - 3 SHORT WIRES
EXPLOSIVE IGNITION
SPARK ELECTRODE LEAD
EXPLOSIVE IGNITION 2
COMBUSTION SEALS
EXPLOSIVE IGNITION 3
HEAT EXCHANGER FLUE WAYS
EXPLOSIVE IGNITION 3
VENTURI
EXPLOSIVE IGNITION 3
BURNER ASSEMBLY
EXPLOSIVE IGNITION 3
FLUE
EXPLOSIVE IGNITION 3
PCB CONTROL JUMPER JP4
EXPLOSIVE IGNITION 2
ELECTRODES
EXPLOSIVE IGNITION 3
COMBUSTION SEALS
EXPLOSIVE IGNITION 1
HEAT EXCHANGER FLUE WAYS
EXPLOSIVE IGNITION 1
VENTURI
EXPLOSIVE IGNITION 1
BURNER ASSEMBLY
EXPLOSIVE IGNITION 1
FLUE
EXPLOSIVE IGNITION 1
PCB CONTROL JUMPER JP4
NO SPARKING 2
SPARK ELECTRODE LEAD
EXPLOSIVE IGNITION 2
HEAT EXCHANGER FLUE WAYS
EXPLOSIVE IGNITION 2
BURNER ASSEMBLY
EXPLOSIVE IGNITION 2
VENTURI
EXPLOSIVE IGNITION 1
COMBUSTION SEALS
EXPLOSIVE IGNITION 2
FLUE
EXPLOSIVE IGNITION 2
PCB CONTROL JUMPER JP4
EXPLOSIVE IGNITION 1
SPARK ELECTRODE LEAD
EXPLOSIVE IGNITION 1
HARNESS IGNITION - 3 SHORT WIRES
EXPLOSIVE IGNITION 3
ELECTRODES
NO SPARKING 3
SPARK ELECTRODE LEAD
FUSE INVESTIGATION
PUMP EXTERNAL
FUSE INVESTIGATION
TRANSFORMER 24V 50VA
FUSE INVESTIGATION
FAN ASSEMBLY - MVL
FUSE INVESTIGATION
GAS VALVE - HONEYWELL
FUSE INVESTIGATION
PLUGLEAD - RECTIFICATION - GAS VALVE
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
POWER LED
Z REDIRECT
MAINS FUSE - PUMP VIA EXT CONTROLS
Z REDIRECT
RUNNING SLOW - NO PUMP
PUMP EXTERNAL
NO POWER TO PUMP
PCB CONTROL
FAN DOES NOT RUN
PUMP EXTERNAL
FAN RUNS
THERMOSTAT - OVERHEAT
FAN RUNS 1
THERMOSTAT - OVERHEAT
FAN DOES NOT RUN
FAN ASSEMBLY - MVL
FAN DOES NOT RUN
PCB CONTROL
FAN RUNS
BOARD ELECTRONIC USER ASSEMBLY
SPARKING PRESENT CH
PCB CONTROL
SPARKING PRESENT
FUSE F3 2AT IGNITION BOARD
POOR CONDITION GAP INCORRECT
ELECTRODES
NO SPARKING 4
ELECTRODES
NO SPARKING
SPARK ELECTRODE LEAD
NO SPARKING
ELECTRODES
NO SPARKING 5
ELECTRODES
NO SPARKING
HARNESS IGNITION - 3 SHORT WIRES
SPARKING NOT PRESENT
ELECTRODES
SPARKING PRESENT
SPARK ELECTRODE LEAD
WATER2
GAS VALVE - HONEYWELL
DRIED ALL WORKING2
IMPULSE TUBE WATER INGRES
BURNER DOES NOT IGNITE
GAS INLET PRESSURE
BURNER DOES NOT IGNITE
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
BURNER DOES NOT IGNITE
GAS VALVE - HONEYWELL
GV HARNESS RECTIFIER
PLUGLEAD - RECTIFICATION - GAS VALVE
BURNER DOES NOT IGNITE
INJECTOR PIPE
BURNER DOES NOT IGNITE
ELECTRODES
NO SPARKING 1
ELECTRODES
NO SPARKING 1
SPARK ELECTRODE LEAD
BURNER DOES NOT IGNITE 1
ELECTRODES
NO SPARKING 6
ELECTRODES
NO SPARKING 1
HARNESS IGNITION - 3 SHORT WIRES
SPARKING NOT PRESENT 1
ELECTRODES
BURNER DOES NOT IGNITE
SPARK ELECTRODE LEAD
BURNER DOES NOT IGNITE
VENTURI
DOES NOT IGNITE
HEAT EXCHANGER FLUE WAYS
BURNER DOES NOT IGNITE
BURNER ASSEMBLY
DOES NOT IGNITE
PCB CONTROL JUMPER JP4
DOES NOT ESTABLISH SHORTING TO EARTH
KIT - CONDENSATE TRAP
BURNER IGNITES BUT DOES NOT ESTABLISH
KIT - CONDENSATE TRAP
IMPULSE TUBE 3
GAS VALVE - HONEYWELL
IMPULSE TUBE 3
IMPULSE TUBE WATER INGRES
BURNER IGNITES BUT DOES NOT ESTABLISH
ELECTRODES
DOES NOT ESTABLISH
HARNESS
BURNER IGNITES BUT DOES NOT ESTABLISH
HEAT EXCHANGER FLUE WAYS
BURNER IGNITES BUT DOES NOT ESTABLISH
BURNER ASSEMBLY
FAULT CODES
Z REDIRECT
FAULT CODE SAFETY STAT 2
THERMOSTAT - OVERHEAT
FAULT CODE SAFETY STAT 1
THERMOSTAT - OVERHEAT
FAULT CODE SAFETY STAT
PUMP EXTERNAL
FAULT CODE SAFETY STAT
THERMISTOR FLOW TEMPERATURE
FAULT CODE THERMISTOR
THERMISTOR FLOW TEMPERATURE
FAULT CODE THERMISTOR
PCB CONTROL
FAULT CODE IGNITION 2
FAN ASSEMBLY - MVL
FAULT CODE IGNITION
PCB CONTROL
POWER LED
PCB CONTROL
FAN DOES NOT RUN
SET - 10 OFF FUSES 4A 20MM
NO LED
HARNESS
FAN RUNS 2
THERMISTOR FLOW TEMPERATURE
SPARKING CONFIRMATION
Z REDIRECT
RADIATORS PROVIDE INSUFFICIENT HEAT
GAS INLET PRESSURE
GAS RATE
KIT - CONDENSATE TRAP
GAS RATE
FLUE
GAS RATE
VENTURI
GAS RATE
FAN ASSEMBLY - MVL
GAS RATE
BURNER ASSEMBLY
RADIATORS PROVIDE INSUFFICIENT HEAT
THERMISTOR FLOW TEMPERATURE
BOILER NOISY
PUMP EXTERNAL
FAULT CODE SAFETY STAT
COMBUSTION SEALS
INSUFFICIENT HEAT
PCB CONTROL JUMPERS
CH TO MUCH HEAT
PCB CONTROL JUMPERS
ELECTRICAL CHECKS
ELECTRICAL CHECKS
BOILER TO TEMPERATURE RADIATORS COOL
PUMP EXTERNAL
BOILER TO TEMPERATURE RADIATORS COOL
THERMISTOR FLOW TEMPERATURE
RADS TOO HOT
THERMISTOR FLOW TEMPERATURE
BOILER NOISY
THERMISTOR FLOW TEMPERATURE
DIES AWAY
GAS INLET PRESSURE
BURNER BAFFLES OUT
HEAT EXCHANGER FLUE WAYS
WATER
GAS VALVE - HONEYWELL
DRIED ALL WORKING
IMPULSE TUBE WATER INGRES
BURNER BAFFLES
BURNER ASSEMBLY
BURNER BAFFLES
FLUE
DIODE INFORMATION
Z REDIRECT
EXPLOSIVE IGNITION - WATER DAMAGE
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION
IMPULSE TUBE WATER INGRES
EXPLOSIVE IGNITION
GAS INLET PRESSURE
EXPLOSIVE IGNITION - NOT OPENING PROPERLY
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION - NOT OPENING PROPERLY 3
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION - NOT OPENING PROPERLY 1
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION - NOT OPENING PROPERLY 2
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
EXPLOSIVE IGNITION 1
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
EXPLOSIVE IGNITION 2
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
EXPLOSIVE IGNITION 3
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
FUSE INVESTIGATION
HARNESS
FUSE INVESTIGATION
FURTHER INFORMATION FUSE BLOWN
POWER LED
HARNESS
PUMP WIRED VIA BOILER PUMP FEED
PUMP EXTERNAL
PUMP WIRED VIA BOILER PUMP FEED
PCB CONTROL
PUMP RUNS
FLOW SWITCH - ALTECNIC
PUMP WIRED VIA BOILER PUMP FEED
HARNESS
FAN DOES NOT RUN
FLOW SWITCH - ALTECNIC
FAN DOES NOT RUN
HARNESS
FAN RUNS OUTPUT FROM PCB
HARNESS
VOLTAGE OK NOT RUNNING
FAN ASSEMBLY - MVL
FAN RUNS
HARNESS
FUSE INVESTIGATION F3
Z REDIRECT
NO SPARKING 2
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
NO SPARKING 1
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
NO SPARKING
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
SPARKING PRESENT
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
IMPULSE TUBE2
WATER LEAK AND GAS VALVE
IMPULSE TUBE2
WATER LEAK
MECHANICAL FAILURE
GAS VALVE - HONEYWELL
SPARKING ABSENT 1
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
SPARKING ABSENT
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
NO SPARKING 3
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
BURNER DOES NOT IGNITE 1
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
DOES NOT IGNITE WITH PRESSURE DROP
GAS VALVE - HONEYWELL
IMPULSE TUBE 3
WATER LEAK AND GAS VALVE
IMPULSE TUBE 3
WATER LEAK
IGNITES BUT DOES NOT ESTABLISH
PCB CONTROL
BURNER IGNITES BUT DOES NOT ESTABLISH
BOARD ELECTRONIC ASSEMBLY - IGNITION PCB
FAULT CODE DRY FIRE
PCB CONTROL
FAULT CODE SAFETY STAT
PCB CONTROL
FAULT CODE SAFETY STAT
HARNESS
FAULT CODE SAFETY STAT
FAULT CODE
FAULT CODE SAFETY STAT 1
PCB CONTROL
FAULT CODE THERMISTOR
HARNESS
FAULT CODE THERMISTOR
FAULT CODE
FAULT CODE IGNITION
Z REDIRECT
FAULT CODE IGNITION
HARNESS
FAULT CODE IGNITION
FAN ASSEMBLY - MVL
POWER LED
TRANSFORMER 24V 50VA
FUSE INVESTIGATION F2
Z REDIRECT
NO LED
BOARD ELECTRONIC USER ASSEMBLY
NO LED
PCB CONTROL
FAN RUNS 2
HARNESS
GAS RATE
HEAT EXCHANGER FLUE WAYS
RADS TOO COOL
PCB CONTROL
FAULT CODE SAFETY STAT 3
THERMOSTAT - OVERHEAT
RADS TOO MUCH HEAT
PCB CONTROL
HEAT EXCHANGER ASSEMBLY
HEAT EXCHANGER ASSEMBLY
IMPULSE TUBE
WATER LEAK AND GAS VALVE
IMPULSE TUBE
WATER LEAK
BURNER BAFFLES
GAS VALVE - HONEYWELL
EXPLOSIVE IGNITION
WATER LEAK AND GAS VALVE
EXPLOSIVE IGNITION
WATER LEAK
3 SHORT WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 SHORT WIRE AND 2 LONG WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
3 SHORT WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 SHORT WIRE AND 2 LONG WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
PUMP DOES NOT RUN - WIRED VIA BOILER PUMP FEED
CHARACTERISTIC TEST FROM PUMP RUNS
PUMP DOES NOT RUN - WIRED VIA EXTERNAL CONTROLS
CHARACTERISTIC TEST FROM PUMP RUNS
PUMP STILL DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION PUMP RUNS WITH LINK
PUMP RUNS BOILER STILL DOES NOT OPERATE
CHARACTERISTIC TEST FROM OBSERVATION PUMP RUNS WITH LINK
3 SHORT WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 SHORT WIRE AND 2 LONG WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
3 SHORT WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 SHORT WIRE AND 2 LONG WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
1 WIRE VERSION
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
TEMPERATURE EXCEEDS 82 °C & CONTINUES TO FIRE
CHARACTERISTIC TEST FROM OBSERVATION - OVERHEAT
BOILER GOES TO FAULT CODE BEFORE 82°C
CHARACTERISTIC TEST FROM OBSERVATION - OVERHEAT
Burner does not ignite
CHARACTERISTIC TEST FROM BURNER IGNITION
Burner ignites but does not establish
CHARACTERISTIC TEST FROM BURNER IGNITION
Boiler to temperature, radiators cool
CHARACTERISTIC TEST FROM CH OPERATION
Boiler and radiators provide too much heat
CHARACTERISTIC TEST FROM CH OPERATION
HW OPERATION UNSATISFACTORY
CHARACTERISTIC TEST FROM DHW OPERATION
HW DEMAND NOT RECOGNISED
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler noisy
CHARACTERISTIC TEST FROM CH OPERATION
Radiators provide insufficient heat
CHARACTERISTIC TEST FROM CH OPERATION
Burner ignites but flame baffles out or dies away
CHARACTERISTIC TEST FROM BURNER IGNITION
NOISY / EXPLOSIVE IGNITION
CHARACTERISTIC TEST FROM BURNER IGNITION
26/09/2019 11:48:15 1907_1_50_1 07/10/2019 10:51:15
26/09/2019 13:47:55
OBSERVATION SPARK ELECTRODE ASSEMBLY AND GAP
CAREFULLY REMOVE THE ELECTRODE FROM THE COMBUSTION BOX DOOR
OBSERVATION APPLIANCE ISOLATED
{GAINPCBACS}
REMO
RESISTANCE FAN
REMOVE CONNECTOR FROM THE FAN
VOLTAGE CONTROL BOARD IN
{GAINPCBACS}
MAINS POWER SUPPLY AT BOILER
{GAINPCBACS}
RESISTANCE FLOW SWITCH
DISCONNECT THE FLOW
NO VOLTAGE TO PUMP - FURTHER INVESTIGATION
VOLTAGE IS ONLY SUPP
RESISTANCE FLOW SENSOR & HARNESS
REMOVE CONNECTOR CN8 FROM THE PCB
RESISTANCE SAFETY STAT
DISCONNECT ONE OF TH
RESISTANCE FAN
REMOVE CONNECTOR FROM THE FAN
RESISTANCE BOILER TEMPERATURE CONTROL
GAIN ACCESS TO BOILER TEMPERATURE CONTROL PCB
REMOVE CONNECTOR FROM PCB
IGNITION BOARD VOLTAGE IN
{GAINPCBACS}
REMOVE WATER FROM IMPULSE TUBE DOES BOILER NOW LIGHT
REMOVE WATER INGRESS FROM IMPULSE TUBE
FIT IMPULSE TUBE BACK TO GAS VALVE AND COMBUSTION CHAMBER
GAS VALVE VOLTAGE
{GAINPCBACS}
OBSERVATION SPARK ELECTRODE ASSEMBLY AND GAP
CAREFULLY REMOVE THE ELECTRODE FROM THE COMBUSTION BOX DOOR
REMOVE WATER FROM IMPULSE TUBE DOES BOILER NOW LIGHT
REMOVE WATER INGRESS FROM IMPULSE TUBE
FIT IMPULSE TUBE BACK TO GAS VALVE AND COMBUSTION CHAMBER
RESISTANCE FLAME SENSE ELECTRODE
CAREFULLY REMOVE THE ELECTRODE FROM THE COMBUSTION BOX DOOR
RESET BOILER (SAFETY STAT)
ENSURE BOILER IS COOL
RESISTANCE SAFETY THERMOSTATS AND HARNESS - FAULT CODE
DISCONNECT CONNECTOR CN8 FROM THE CONTROL PCB
RESISTANCE SAFETY STAT
DISCONNECT ONE OF TH
RESISTANCE FLOW SENSOR & HARNESS
REMOVE CONNECTOR CN8 FROM THE PCB
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
FAN RUNS - FAULT CODE
ENSURE BOILER IS COOL
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR CN4 FROM THE RIGHT HAND PCB
RESISTANCE FAN
REMOVE CONNECTOR FROM THE FAN
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
REMOVE WATER FROM IMPULSE TUBE DOES BOILER NOW LIGHT
REMOVE WATER INGRESS FROM IMPULSE TUBE
FIT IMPULSE TUBE BACK TO GAS VALVE AND COMBUSTION CHAMBER
REMOVE WATER FROM IMPULSE TUBE DOES BOILER NOW LIGHT
REMOVE WATER INGRESS FROM IMPULSE TUBE
FIT IMPULSE TUBE BACK TO GAS VALVE AND COMBUSTION CHAMBER
OBSERVATION SPARK ELECTRODE ASSEMBLY AND GAP
CAREFULLY REMOVE THE ELECTRODE FROM THE COMBUSTION BOX DOOR
OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
PLEASE SELECT WHICH TYPE OF ELECTRODE IS FITTED TO THE APPLIANCE.
RESISTANCE SPARK ELECTRODE - NO WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 3 SHORT WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 SHORT 2 LONG WIRE VERSION
DISCONNECT THE LEADS
OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
PLEASE SELECT WHICH TYPE OF ELECTRODE IS FITTED TO THE APPLIANCE.
RESISTANCE SPARK ELECTRODE - NO WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 3 SHORT WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 SHORT 2 LONG WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 WIRE VERSION
DISCONNECT THE LEADS
INSPECTION CONTROL BOARD JP4 (POOR IGNITION)
REMOVE CONTROL PCB (RIGHT PCB) FROM ITS HOUSING
INSPECTION CONTROL BOARD JP4 (POOR IGNITION)
REMOVE CONTROL PCB (RIGHT PCB) FROM ITS HOUSING
INSPECTION CONTROL BOARD JP4 (POOR IGNITION)
REMOVE CONTROL PCB (RIGHT PCB) FROM ITS HOUSING
INSPECTION CONTROL BOARD JP4 (POOR IGNITION)
REMOVE CONTROL PCB (RIGHT PCB) FROM ITS HOUSING
RESISTANCE PUMP
DISCONNECT WIRES FROM PUMP
(PUMP IS FITTED EXTERNAL TO APPLIANCE)
RESISTANCE TRANSFORMER
{GAINPCBACS}
DISCONNECT PLUG CN5 FROM THE CONTROL PCB
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR CN4 FROM THE RIGHT HAND PCB
RESISTANCE GAS VALVE
DISCONNECT GAS VALVE ELECTRICAL CONNECTOR PLUG
(HELD BY ONE CENTRE SCREW) FROM GAS VALVE
DIODE TEST HARNESS GAS VALVE
REMOVE THE CONNECTOR
OBSERVATION PUMP RUNS WITH LINK
{GAINPCBACS}
INSE
PUMP SUPPLY
GAIN ACCESS TO PUMP ELECTRICAL CONNECTIONS, USE ISOLATION MAT AS REQUIRED
RESISTANCE FLOW SWITCH
DISCONNECT THE FLOW
RESISTANCE SAFETY THERMOSTATS AND HARNESS
DISCONNECT CONNECTOR CN8 FROM THE CONTROL PCB
RESISTANCE BOILER TEMPERATURE CONTROL & HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB
RESISTANCE FAN PROTECTION STAT
DISCONNECT ONE OF TH
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR CN4 FROM THE RIGHT HAND PCB
VOLTAGE FAN UPLIFT ON CONTROL PCB
{GAINPCBACS}
FUSE F3
REMOVE FUSE F3 FROM THE IGNITION PCB
OBSERVATION SPARK ELECTRODE ASSEMBLY AND GAP
CAREFULLY REMOVE THE ELECTRODE FROM THE COMBUSTION BOX DOOR
OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
PLEASE SELECT WHICH TYPE OF ELECTRODE IS FITTED TO THE APPLIANCE.
RESISTANCE SPARK ELECTRODE - NO WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 3 SHORT WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 SHORT 2 LONG WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 WIRE VERSION
DISCONNECT THE LEADS
CHECK IMPULSE TUBE FOR WATER
IMPULSE TUBE IS LOCATED ON THE GAS VALVE
RUNNING TO THE COMBUSTION CHAMBER
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
GAS USAGE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
ENSURE NO OTHER GAS APPLIANCES ARE IN USE
OBSERVATION SPARKING AT ELECTRODE
REMOVE THE TOP TWO S
GAS VALVE RESISTANCE
DISCONNECT GAS VALVE ELECTRICAL CONNECTOR PLUG (HELD BY ONE CENTRE SCREW) FROM GAS VALVE
DIODE TEST HARNESS GAS VALVE
REMOVE THE CONNECTOR
OBSERVATION WHICH TYPE OF ELECTRODE IS FITTED ?
PLEASE SELECT WHICH TYPE OF ELECTRODE IS FITTED TO THE APPLIANCE.
RESISTANCE SPARK ELECTRODE - NO WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 3 SHORT WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 SHORT 2 LONG WIRE VERSION
DISCONNECT THE LEADS
RESISTANCE SPARK ELECTRODE - 1 WIRE VERSION
DISCONNECT THE LEADS
INSPECTION CONTROL BOARD JP4
REMOVE CONTROL PCB (RIGHT PCB) FROM ITS HOUSING
DISCONNECT CONDENSATE TRAP WIRE
DISCONNECT THE WIRE FROM THE CONDENSATE TRAP AND MAKE SAFE
CHECK IMPULSE TUBE FOR WATER
IMPULSE TUBE IS LOCATED ON THE GAS VALVE
RUNNING TO THE COMBUSTION CHAMBER
RESISTANCE FLAME SENSE ELECTRODE LEAD
DISCONNECT THE FLAME SENSE LEAD / INLINE CONNECTOR FROM THE ELECTRODE
RESISTANCE FAN PROTECTION STAT
DISCONNECT ONE OF TH
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
RESET BOILER
ENSURE BOILER IS COOL
VOLTAGE FAN UPLIFT ON CONTROL PCB
{GAINPCBACS}
FAN RUNS - NO LED
ENSURE BOILER IS COOL
RESISTANCE HARNESS BOARD ELECTRONIC
REMOVE CONNECTORS CN3 CONTROL PCB & FROM ELECTRONIC USER PCB
RESISTANCE FUSE F2
REMOVE FUSE F2 FROM THE CONTROL PCB
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
INSPECTION FAN ASSEMBLY
REMOVE FAN ASSEMBLY & AIR INTAKE FROM FAN ASSEMBLY
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
RESISTANCE FLOW SENSOR
DISCONNECT ONE OF THE RED WIRES FROM THE THERMISTOR
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
CHECK IMPULSE TUBE FOR WATER
IMPULSE TUBE IS LOCATED ON THE GAS VALVE
RUNNING TO THE COMBUSTION CHAMBER
CHECK IMPULSE TUBE FOR WATER
IMPULSE TUBE IS LOCATED ON THE GAS VALVE
RUNNING TO THE COMBUSTION CHAMBER
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
OBSERVATION SPARKING AT ELECTRODE
REMOVE THE TOP TWO S
System Information
- Total Tests: 429
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control