Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Carefully remove the electrode from the combustion box door
Observation:
Thoroughly inspect the spark electrode assembly for damage, cracked ceramic and for correct spark gap.
You may have any of the pictured electrodes depending upon the appliance serial number.
All types of the electrode can be deemed satisfactory
as long as the spark gap is 4.0mm +/- 1mm.
Note:
Before reassembly check the integrity of all disturbed
gaskets and seals and replace as necessary.
You may have any of the pictured electrodes depending upon the appliance serial number.
All types of the electrode can be deemed satisfactory
as long as the spark gap is 4.0mm +/- 1mm.
Note:
Before reassembly check the integrity of all disturbed
gaskets and seals and replace as necessary.
Isolate as per TOPs P4
and refit as necessary