VAILLANT ECOMAX PRO 18 AND 28E
GLOBALLY REPLACED
CH OPERATION
ENSURE ALL HEATING CONTROLS ARE CALLING
F6 FAULT CODE
OUT OF MODEL
F8 / F12 FAULT CODE
HEADER FOR F8 / F12 FAULT CODE - OUTSIDE MODEL
OVERHEAT INVESTIGATION
OUT OF MODEL
F2 F3 FAULT CODE
OUT OF MODEL
F11 / F13 FAULT CODE
HEADER FOR F11 / F13 FAULT CODE - OUTSIDE MODEL
F17 FAULT CODE
OUT OF MODEL
FUSE INVESTIGATION IRIS
OUTSIDE MODEL
FUSE INVESTIGATION SYMS
OUTSIDE MODEL
F14 FLOW ABOVE 95 DEG
OUT OF MODEL
BOILER SHUT DOWN
ENSURE ALL HEATING CONTROLS ARE CALLING
F18 FAULT CODE
HEADER FOR FAULT CODE - NOT USED
F20
OUTSIDE MODEL
F2 F3
HARNESS - CONTROL
FAN SPEED CONTROL
FAN ASSEMBLY
F3 NO VOLTAGE ON DEMAND
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
HALL SENSOR
FAN ASSEMBLY
BLOWING FUSE
GAS VALVE ASSEMBLY
BLOWN FUSE
IGNITOR - ZIG
FUSE F1 IRIS
GAS VALVE ASSEMBLY
FUSE F1 IRIS
IGNITOR - ZIG
FUSE F1 IRIS
TRANSFORMER - WIJDEVEN
BLOWING FUSES
SYSTEM PUMP FAULT
IRISBLOWING FUSES
SYSTEM PUMP FAULT
F14 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT 4F14
SYSTEM PUMP FAULT
FAULTY 1
MOD CARD
FAN CONTROL 29999
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
CALIBRATION 19999
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 19999
THERMISTOR - HEATING FLOW / RETURN
OC 19999
THERMOSTAT - OVERHEAT
FAN CONTROL 2
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
CALIBRATION 1
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 1
THERMISTOR - HEATING FLOW / RETURN
OC 1
THERMOSTAT - OVERHEAT
PREHEAT FAN FUNCTION
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
BLOWN
FUSE F2
BLOCKED 2
SIPHON
FLAME SENSE
LEAD - IGNITION
ELECTRODE RECTIFICATION
ELECTRODE - SPARK
PUMP FUNCTION 1
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT 3
SYSTEM PUMP FAULT
FAULT CODE F11/12
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
OVERHEAT 2
THERMISTOR - HEATING FLOW / RETURN
OVERHEAT
THERMISTOR - HEATING FLOW / RETURN
F13
WIRING HARNESSES
FAULT CODE 11 F13
HARNESS - INTERFACE
FAULT CODE F11/12 F13
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F12 IRIS SYMS PCB
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F12 IRIS SYMS PCB F13
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F18
BOARD - DISPLAY
FLASHING DISPLAY (SYMS)
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FLASHING DISPLAY IRIS PCB
HARNESS - INTERFACE
PUMP FUNCTION 2
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FATIGUE SYSMI
FUSE (FUSED SPUR)
BLOWN
FUSE F1
NO DISPLAY
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
DISPLAY PCB VOLTAGE
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT 4
SYSTEM PUMP FAULT
NO DISPLAY
HARNESS - INTERFACE
FATIGUE IRIS
FUSE (FUSED SPUR)
BLOWN
FUSE F1
FAULT 2
HARNESS - INTERFACE
INFORMATION DISPLAY SETUP
Z BLANK
F8
PARAMETER SETTING
FAN RUNSFAN SPEED CONTROL
FAN ASSEMBLY
FAN RUNS CONTINUALLY
HARNESS - CONTROL
FAN RUNS9999
HARNESS - CONTROL
FAN RUNS
HARNESS - CONTROL
NO SPARKING
HARNESS - CONTROL
F20
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
INSPECTION FLUE COLLECTOR AND SEALS
FLUE COLLECTOR / SEALS
CALIBRATION 2
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 2
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 4
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 4
THERMISTOR - HEATING FLOW / RETURN
OC 2
THERMOSTAT - OVERHEAT
FAULT 3
FLUE
FAULT 3
SIPHON
CALIBRATION 3
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 3
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 5
THERMISTOR - HEATING FLOW / RETURN
CALIBRATION 5
THERMISTOR - HEATING FLOW / RETURN
OC 3
THERMOSTAT - OVERHEAT
FAULT 4
FLUE
FAULT 4
SIPHON
CH OPERATION 2F14
THERMISTOR - HEATING FLOW / RETURN
CH CALIBRATIONF14
THERMISTOR - HEATING FLOW / RETURN
FLUEWAYS SHUTTING OFF
HEAT EXCHANGER
FAULTY
FLUE
NOT ESTABLISHING
GAS VALVE SETTINGS
RECTIFICATION
IGNITOR - ZIG
COMBUSTION
SIPHON
BLOCKED999RATIO
FLUE
COMBUSTION
BURNER
FLUEWAYS
HEAT EXCHANGER
BLOCKED
SIPHON
BLOCKED
FLUE
GAP
ELECTRODE - SPARK
BURNER IGNITES - DOES NOT IGNITE - LOW PRESSURE
HEAT EXCHANGER
PART BLOCKED OR DAMAGED
BURNER
NO VOLTAGE TO GAS VALVE
PCB + GAS VALVE
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY CHECKS
DIRECTIONAL
Z DIRECTION
FAULT CODES
Z DIRECTION
F19FAULT F6
THERMISTOR - HEATING FLOW / RETURN
F10F19
THERMISTOR - HEATING FLOW / RETURN
FAULT F16
GAS VALVE ASSEMBLY
FAULT F6
THERMISTOR - HEATING FLOW / RETURN
F10
THERMISTOR - HEATING FLOW / RETURN
FAULT CODE 11
HARNESS - INTERFACE
F5 FAULTF5 FAULT
THERMOSTAT - OVERHEAT
F5 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F5 FAULT CODE
SYSTEM PUMP FAULT
F5 FAULTF25
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F5 FAULT CODELIMIT TEMP
SYSTEM PUMP FAULT
OVERHEATLIMIT TEMP
THERMISTOR - HEATING FLOW / RETURN
1F5/F9LIMIT TEMP
THERMISTOR - HEATING FLOW / RETURN
OC 4
THERMOSTAT - OVERHEAT
CASE OFF
Z DIRECTION
FUSE F1 IRIS
BOARD 230V - OPTION
FUSE
BOARD 230V - OPTION
DAMAGE
ELECTRODE - SPARK
F1 LOCKOUT
WIRING HARNESSES
OVERHEAT
THERMISTOR - HEATING FLOW / RETURN
1F5/F9
THERMISTOR - HEATING FLOW / RETURN
1F5 FAULT
THERMOSTAT - OVERHEAT
PUMP OVERRUN
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
POOR NOT ESTABLISH
GAS SUPPLY
CYCLING NO DEMAND
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAN SPEED CONTROL
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F2 F3 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
SYMS FUSE
HARNESS - CONTROL
NO FAULT
FUSE INVESTIGATION SYMS PCB
SPARK GENERATOR
HARNESS - IGNITION
IRIS FUSE
HARNESS - CONTROL
SPARK GEN IRIS
HARNESS - IGNITION
NO FAULT
FUSE INVESTIGATION IRIS PCB
PUMP
HARNESS - PUMP
IRISPUMP
HARNESS - PUMP
F14 FAULT
SYSTEM PUMP FAULT
FAN RUN PREHEAT
TRANSFORMER - WIJDEVEN
PREHEAT FAN RUN
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
PREHEAT DEMAND
FAN ASSEMBLY
FAN RUN PREHEAT 2
TRANSFORMER - WIJDEVEN
FAULT 1
SYSTEM PUMP FAULT
PERMANENT DEMAND 240
BOARD 230V - OPTION
NO FAN OPERATION
FAN ASSEMBLY
NO FAN OPERATION 2
FAN ASSEMBLY
NO FAN OPERATION 3
FAN ASSEMBLY
NO FAN OPERATION 4
FAN ASSEMBLY
FAN SPEED
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT CODE F3
FAN ASSEMBLY
FAULT CODE F3 2
FAN ASSEMBLY
FAULT F5F5 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
OVERHEAT 3
HARNESS - CONTROL
OVERHEAT 4
HARNESS - CONTROL
F13 RESET
Z DIRECTION
F8 / F12 IRIS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
F8 / F12 SYMS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
F11 / F13 IRIS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
F11 / F13 SYMS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT 2
SYSTEM PUMP FAULT
JUMBLED DISPLAY - SYMS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
JUMBLED DISPLAY - IRIS
PCB - MAIN - CONNECTION FAULT (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULTY
HARNESS - MAINS INLET
FUSE INVESTIGATION 1AFUSE IRIS
Z BLANK
NO DISPLAY B2
FAN ASSEMBLY
FAULTY
BOARD - DISPLAY
FAULTY9999
HARNESS - MAINS INLET
FUSE FURTHER INVESTIGATION
Z BLANK
FUSE INVESTIGATION 1A
Z BLANK
NO DISPLAY IRIS PCB
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO DEMAND TO FAN
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO DEMAND TO FAN 3
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
OVERHEAT NOT SHUTTING OFF
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAN RUNSFAN SPEED CONTROL
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO SPARKING F2 F3 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO SPARKING HALL SENSOR
FAN ASSEMBLY
DHW CALIBRATION
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
DHW BOILER SHUTS DOWN PREMATURELY
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
CH INSUFF HEAT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
CH BOILER SHUTS DOWN PREMATURELY
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
AIRRESCRICTIONS
BOILER NOW WORKING
TEMP FAULT CODE NOT SHUTTING OFF
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
OVERHEAT2OVERHEATLIMIT TEMP
HEAT EXCHANGER
F14AIRRESCRICTIONS
BOILER NOW WORKING
F14TEMP FAULT CODE NOT SHUTTING OFF
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F14OVERHEAT2OVERHEATLIMIT TEMP
HEAT EXCHANGER
FLAME SENSE FUNCTION
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
COMBUSTION
GAS VALVE SETTINGS
NOT PASSING
GAS VALVE ASSEMBLY
POOR 3
GAS SUPPLY
NOT PASSING 999
GAS VALVE ASSEMBLY
GASVALVE FUNCTION
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F19F6 FAULT CODE
HARNESS - CONTROL
FAULT F6F10 FAULTF19
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F6 FAULT CODEF10 FAULTF19
HARNESS - CONTROL
FAULT F16
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT F6
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F6 FAULT CODE
HARNESS - CONTROL
FAULT F6F10 FAULT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F6 FAULT CODEF10 FAULT
HARNESS - CONTROL
F5 FAULT
SYSTEM PUMP FAULT
F5 FAULTF25
SYSTEM PUMP FAULT
OVERHEATLIMIT TEMP
HARNESS - CONTROL
OVERHEAT2LIMIT TEMP
HARNESS - CONTROL
FAN FUNCTION 1
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO VOLTAGE TO CONTROL PCB
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
NO CH DEMAND
BOARD 230V - OPTION
F17
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
F17 IRIS
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
FAULT
IGNITOR - ZIG
DAMAGE
LEAD - IGNITION
F1 LOCKOUT
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
OVERHEAT
HARNESS - CONTROL
OVERHEAT2
HARNESS - CONTROL
OVERHEAT
TEMPERATURE OVERHEAT
OVERHEAT2OVERHEAT
HEAT EXCHANGER
1FAULT F5
PCB - MAIN (SAME PART AS BG330 - GLOWWORM XI MODELS)
Boiler shuts down prematurely
CHARACTERISTIC TEST FROM DHW OPERATION
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION DOES FAN RUN BEFORE FAULT
FAN RUNS ON HIGH SPEED WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION DOES FAN RUN BEFORE FAULT
SYMS17 0 AS STANDARD NO CONTROLLER OR CARD
CHARACTERISTIC TEST FROM TYPE OF FAN CONTROL
SYMS17 0 AS MOD WITH CARD
CHARACTERISTIC TEST FROM TYPE OF FAN CONTROL
Boiler temperature low, system temperature low
CHARACTERISTIC TEST FROM CH OPERATION
Boiler to temperature, radiators cool
CHARACTERISTIC TEST FROM CH OPERATION
VOLTAGE BEHAVES AS DESCRIBED
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)
VOLTAGE ABSENT (LESS THAN 1 VDC, E G 0 VDC)
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL
VOLTAGE BEHAVES AS DESCRIBED
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)
VOLTAGE ABSENT (LESS THAN 1 VDC, E G 0 VDC)
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL
Boiler shuts down prematurely
CHARACTERISTIC TEST FROM DHW OPERATION
VOLTAGE BEHAVES AS DESCRIBED
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)
VOLTAGE ABSENT ( LESS THAN 1 VDC, E G 0 VDC)
CHARACTERISTIC TEST FROM VOLTAGE FAN CONTROL (FAULT CODE F3)
DISPLAY DOES NOT OPERATE
CHARACTERISTIC TEST FROM DISPLAY
DISPLAY OPERATES BUT FLASHES OR DOES NOT SHOW CORRECT INFORMATION
CHARACTERISTIC TEST FROM DISPLAY
FAN RUNS IMMEDIATELY AND CONTINUALLY AT HIGH SPEED
CHARACTERISTIC TEST FROM FAN RUNS
BOILER TEMP RISES RAPIDLY
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
DIFFERENTIAL NOT OK
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
BOILER TEMP RISES RAPIDLY
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
DIFFERENTIAL NOT OK
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
INLET PRESSURE DOES NOT DIP TO INDICATE GAS VALVE IS OPENING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP
INLET PRESSURE UNSATISFACTORY
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP
Fan runs for approximately 4 seconds then stops
CHARACTERISTIC TEST FROM FAN RUNS
Fan does not run
CHARACTERISTIC TEST FROM FAN RUNS
20V OR GREATER MEASURED ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE CONTROLS PCB DEMAND
LESS THAN 2V MEASURED ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE CONTROLS PCB DEMAND
SPARKING PRESENT BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITION
Sparking absent
CHARACTERISTIC TEST FROM BURNER IGNITION
BOILER GOES TO F1 FAULT CODE WITHOUT 3 ATTEMPTS TO IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITION
Appliance does not react to DHW demand
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler to temperature, DHW cool
CHARACTERISTIC TEST FROM DHW OPERATION
BOILER TEMP RISES RAPIDLY
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
BOILER TEMP GOES ABOVE 87 DEGREES AND DOESNT CUT OFF
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
BOILER LOCKS OUT ON OVERHEAT BEFORE REACHING 87 DEGREES
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
DIFFERENTIAL NOT OK
CHARACTERISTIC TEST FROM CH TEST TEMPERATURE
Boiler temperature low, DHW temperature low
CHARACTERISTIC TEST FROM DHW OPERATION
08/06/2021 15:40:06 2106_1_50_1 14/07/2021 11:19:26
05/07/2021 08:56:11
VOLTAGE CONTROL PCB NO DEMAND
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
FAN LOOM CONTINUITY
REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN
RESISTANCE GAS VALVE
DISCONNECT LEADS FROM THE GAS VALVE
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTORS FROM SPARK GENERATOR
RESISTANCE GAS VALVE
DISCONNECT LEADS FROM THE GAS VALVE
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTORS FROM SPARK GENERATOR
RESISTANCE PUMP
THE PUMP IS NOT AN I
RESISTANCE PUMP
THE PUMP IS NOT AN I
PUMP VOLTAGE (CH)
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON
FAN DC SU (INPUT VOLTAGE)
REMOVE REAR COVER OF CONTROL PANEL TO EXPOSE MAIN PCB
FAN VOLTAGE J4 DISCONNECTED
{MAINSRSSWOFF}
DISCONNECT J4 CONNECTOR AT PCB AND MAKE SAFE
FUSE RESISTANCE (DCSU)
REMOVE FUSE F2 FROM ITS HOLDER IN THE FAN DC SUPPLY CONTROL UNIT
PUMP VOLTAGE (DHW)
ENSURE THERE IS A DE
EXTERNAL CONTROLS VOLTAGE (OUTPUT) NO DEMAND
{MAINSRSSWOFF}
RE
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
RESISTANCE HARNESS USER INTERFACE
REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB
MAIN PCB TO DISPLAY PCB VOLTS
{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAIN PCB TO DISPLAY PCB VOLTS
{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
PUMP VOLTAGE (CH)
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON
MAIN PCB TO DISPLAY PCB VOLTS
{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH VOLTAGE
GAIN ACCESS TO PCB (
RESISTANCE MAINS FUSE (3AMP)
REMOVE FUSE FROM FUSED SPUR
INSPECTION PCB CAPACITORS
{MAINSRSSWOFF}
MAINS RESET SWITCH VOLTAGE
GAIN ACCESS TO PCB (
RESISTANCE MAINS FUSE (3AMP)
REMOVE FUSE FROM FUSED SPUR
VOLTAGE FAN HALL SENSOR
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
ENSURE BOILER IS COOL
FAN LOOM CONTINUITY
REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN
RESISTANCE GAS VALVE
DISCONNECT LEADS FROM THE GAS VALVE
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
INSPECTION BURNER GAS SHUTDOWN
HW DEMAND
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
RESISTANCE HARNESS USER INTERFACE
REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB
BOILER RESET
ALLOW BOILER TO COOL
RESET OVERHEAT BY PUSHING IN RED BUTTON (IF NECESSARY)
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
PUMP VOLTAGE (CH)
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON
PUMP VOLTAGE (CH)
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
IDENTIFY PCB
REMOVE CONTROL BOX COVER
RESISTANCE CONTROLS INTERFACE IRIS
REMOVE REAR CONTROL
RESISTANCE CONTROLS INTERFACE
REMOVE REAR CONTROL
SPARK GENERATOR (INPUT)
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
MAINS RESET SWITCH ON
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
MAINS RESET SWITCH ON
OBSERVATION DOES FAN RUN BEFORE FAULT
ENSURE BOILER IS COOL
VOLTAGE FAN HALL SENSOR
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
ENSURE BOILER IS COOL
FAN VOLTAGE
{MAINSRSSWOFF}
VOLTAGE FAN SPEED CONTROL
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
VOLTAGE FAN CONTROL (FAULT CODE F3)
{MAINSRSSWOFF}
RESISTANCE GAS VALVE AND HARNESS
{MAINSRSSWOFF}
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE REAR CONTROL PANEL COVER TO EXPOSE MAIN PCB
REMOVE CONNECTOR H2 FROM MAIN PCB
RESISTANCE GAS VALVE AND HARNESS IRIS
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS IRIS
REMOVE REAR CONTROL PANEL COVER TO EXPOSE MAIN PCB
REMOVE CONNECTOR H2 FROM MAIN PCB
RESISTANCE DC FAN CONTROLLER
DISCONNECT FAN DC CONTROLLER CONNECTOR MARKED H3 ON THE MAIN PCB.
TYPE OF FAN CONTROL
THERE ARE THREE TYPE
FAN VOLTAGE
{MAINSRSSWOFF}
FAN VOLTAGE
{MAINSRSSWOFF}
IS MOD CARD PRESENT
{MAINSRSSWOFF}
FAN VOLTAGE
{MAINSRSSWOFF}
VOLTAGE FAN CONTROL
{MAINSRSSWOFF}
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
VOLTAGE FAN CONTROL
{MAINSRSSWOFF}
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
FAN TEST (DISCONNECTED)
DISCONNECT CONNECTOR MARKED J4 FROM THE
MAIN PCB AND MAKE SAFE
ELECTRODE LEAD INSPECTION
REMOVE THE ELECTRODE LEAD FROM THE BOILER
SPARK ELECTRODE
REMOVE ELECTRODE ASSEMBLY
EXTERNAL PUMP RUNS (CH)
MAINS RESET SWITCH ON
INSPECTION PCB CAPACITORS
{MAINSRSSWOFF}
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
OBSERVATION BOILER RESET F13 FAULT
ON/OFF SWITCH ON
INSPECTION PCB CAPACITORS
{MAINSRSSWOFF}
IDENTIFY PCB
REMOVE CONTROL BOX COVER
IDENTIFY PCB
REMOVE CONTROL BOX COVER
IDENTIFY PCB
REMOVE CONTROL BOX COVER
IDENTIFY PCB
REMOVE CONTROL BOX COVER
RESISTANCE HARNESS USER INTERFACE
REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB
FUSE F1 (RES) SYMS
REMOVE FUSE F1 FROM ITS HOLDER ON THE MAIN PCB
REMOVE FAN CONNECTOR SYMS
{MAINSRSSWOFF}
REMOVE J4 CONNECTOR FROM THE PCB AND PLACE IT SAFELY AWAY FROM THE BOARD
MAIN PCB TO DISPLAY PCB VOLTS
{MAINSRSSWOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE HARNESS USER INTERFACE
REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB
FUSE F1 (RES) IRIS
REMOVE FUSE F1 FROM ITS HOLDER ON THE MAIN PCB
RESISTANCE HARNESS USER INTERFACE
REMOVE THE HARNESS FROM THE MAIN PCB TO THE USER CONTROL PCB
VOLTAGE FAN SPEED CONTROL
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
FAN LOOM CONTINUITY
REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN
FAN LOOM CONTINUITY
REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN
FAN LOOM CONTINUITY
REMOVE THE FAN LOOM FROM THE PCB (J4) AND THE FAN
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
CH TEST TEMPERATURE
ATTACH FGA TEMPERATU
FLOW THERMISTOR
REMOVE THE BLUE LEADS FROM THE FLOW THERMISTOR
RETURN THERMISTOR
DISCONNECT WHITE WIRES FROM THE THERMISTOR
CH TEST TEMPERATURE
ATTACH FGA TEMPERATU
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY
RESET GAS VALVE
RESET GAS VALVE THRO
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY
PRESSURE GAS INLET AND DIP
ATTACH PRESSURE GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
MAINS RESET SWITCH ON
SPARK ELECTRODE
REMOVE ELECTRODE ASSEMBLY
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE FAN, GAS VALVE AND BURNER ASSEMBLY
GAS VALVE VOLTAGE
PLACE MULTIMETER PRO
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
VOLTAGE CONTROLS PCB DEMAND
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
USE INSULATION MAT AS REQUIRED
EXTERNAL CONTROLS VOLTAGE (OUTPUT)
{MAINSRSSWOFF}
RE
RESISTANCE PUMP AND HARNESS IRIS
REMOVE REAR CONTROL
RESISTANCE PUMP AND HARNESS
REMOVE REAR CONTROL
SPARK GENERATOR (OUTPUT)
ENSURE THE APPLIANCE
SPARK ELECTRODE
REMOVE ELECTRODE ASSEMBLY
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE THE CONNECTOR J1 FROM THE PCB
CH TEST TEMPERATURE
ATTACH FGA TEMPERATU
THERMOSTAT OVERHEAT - OVERHEAT THERMOSTAT
DISCONNECT BLACK LEADS FROM THE OVERHEAT THERMOSTAT
EXTERNAL PUMP RUNS (DHW)
MAINS RESET SWITCH ON
System Information
- Total Tests: 470
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control