Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove rear control panel cover to expose main PCB
Disconnect controls interface connector marked H7 on the main PCB
Disconnect controls interface connector marked H7 on the main PCB
Measurement:
Test 1:
Measure resistance between the live (brown lead) and
neutral (blue lead) connection on the connector.
Test 2:
Measure resistance between the live
(brown lead) and a suitable Earth.
Expected resistance O.L or greater than 1MOhm on both tests.
Measure resistance between the live (brown lead) and
neutral (blue lead) connection on the connector.
Test 2:
Measure resistance between the live
(brown lead) and a suitable Earth.
Expected resistance O.L or greater than 1MOhm on both tests.

Isolate as per TOPs P4
and refit as necessary