BIASI ADVANCE 25/30/35 C

GLOBALLY REPLACED

Next: &1, *

NO FAULT FOUND

Next: nff

BIASI ADVANCE 25/30/35 C

Next: &706, !f2

OBSERVATION BOILER INITIALISATION

BOILER IN CH AND DHW MODE, NO DEMANDS

Next: &244, ?146, ?148, ?212, ?1358, ?1360

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &246, !f245

OBSERVATION DHW FLOW RATE

Next: &257, f1923

OBSERVATION DHW DEMAND RECOGNISED

FLOW RATE SET TO 3 LITRES A MIN
BOILER DHW THERMOSTAT SET TO MAX

Next: &267, f258

OBSERVATION PUMP RUNNING

Next: &284, f268

OBSERVATION FAN RUNS

BOILER DHW THERMOSTAT SET TO MAX

Next: &292, f285

OBSERVATION BURNER IGNITES AND ESTABLISHES

BOILER DHW THERMOSTAT SET TO MAX

Next: &606, ?293, ?295, ?297, ?299

PERFORMANCE ANALYSIS

BOILER IN SERVICE MODE

Next: &422, f2006

OPERATION DHW

BOILER DHW SETTING TO MAX
REFIT DIVERTER VALVE MOTOR

Next: &552, ?423, ?425, ?427, ?429, ?431

OBSERVATION CH DEMAND RECOGNISED

USER CONTROL SET TO

Next: &629, f1839

OBSERVATION PREHEAT OPERATION

BOILER DHW THERMOSTAT SET TO MAX

Next: &602, !f601

OBSERVATION ANTI CYCLE DELAY

BOILER CH THERMOSTAT SET TO 50°C

Next: &nff, !f605

PRESSURE GAS INLET PRIMARY TEST

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
REMOVE THE DIVERTER VALVE MOTOR

Next: &386, !f607

OPERATION CH

BOILER CH THERMOSTAT SET TO MAX

Next: &600, ?630, ?644, ?678, ?1147

IMPORTANT NOTES FOR THIS APPLIANCE PLEASE READ THOROUGHLY

THIS APPLIANCE INCOR

Next: &143, !f707

HEADER FOR FUSE FURTHER INVESTIGATION

INTENTIONALLY BLANK HEADER FOR FUSE INVESTIGATION

Next: &nff, f722

HEADER FOR E04

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f746

HEADER FOR E05

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f872

HEADER FOR E06 AND E12

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f757

HEADER FOR E07

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f766

HEADER FOR E08

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f799

HEADER FOR E09

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f771

HEADER FOR E10

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f1098

HEADER FOR OVERHEAT INVESTIGATION E02, E13, E14, L01

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f1160

HEADER FOR E69

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, !f778

HEADER FOR E19

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, !f787

HEADER FOR E99

INTENTIONALLY BLANK FAULT CODE HEADER

Next: &nff, f796

COMBUSTION MODE PAGE

Next: &nff, !f1121

SERVICE MODE INFORMATION PAGE

THE 🔧 SYMBOL

Next: &nff, !f1543

HEADER FOR E25 AND E11

BLANK

Next: &nff, f1948

E10 FAULT CODE

FLUE TEMPERATURE PROBE NTC - SAFETY THERMAL FUSE (THERMISTOR COMPONENT)

Next: End

E10 FAULT CODE

MANIFOLD - AIR

Next: End

E10 FAULT CODE

AIR BOX ASSEMBLY

Next: End

E10 FAULT CODE

CONDENSATE TRAP OR PIPEWORK

Next: End

DIVERTER VALVE SECTION BLOWING FUSES

CABLE - 230V ELECTRICITY SUPPLY

Next: End

BLOWING FUSES FAN SECTION

CABLE - 230V ELECTRICITY SUPPLY

Next: End

BLANK FOR COMBUSTION MODE PAGE

Z DIRECTION CHOICE OR CONTINUE

Next: End

IGNITES BUT DOES NOT ESTABLISH

CONDENSATE TRAP OR PIPEWORK

Next: End

OVERPRESSURING ON CH

VESSEL - EXPANSION

Next: End

OPEN CIRCUIT

THERMOSTAT 105 DEG C OVERHEAT

Next: End

NOT SUPPLYING POWER TO DIVERTER FOR DHW FOR OVERHEAT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

POWER TO DIVTERTER VALVE DHW FOR OVERHEAT

CABLE - 230V ELECTRICITY SUPPLY

Next: End

OVERHEAT INVESTIGATION

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

PUMP NOT RUNNING

CABLE - 230V ELECTRICITY SUPPLY

Next: End

BOILER TO TEMP RADS COLD

TAP 3/4 IN - CH

Next: End

BLANK FOR FAULT CODES 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

WEAK NOISY CH

PUMP

Next: End

BLANK FOR SERVICE INDICATOR

Z DIRECTION CHOICE OR CONTINUE

Next: End

DHW TOO COOL

FLUE TEMPERATURE PROBE NTC - SAFETY THERMAL FUSE (THERMISTOR COMPONENT)

Next: End

WEAK CAUSING DHW TOO COOL

PUMP

Next: End

DHW HOT AND COLD

FLUE TEMPERATURE PROBE NTC - SAFETY THERMAL FUSE (THERMISTOR COMPONENT)

Next: End

HOLDING FAN OFF

TEMPERATURE PROBE - OUTLET

Next: End

MAINS FUSE

FUSE MAINS

Next: End

PUMP NOT RUNNING OVERHEAT

CABLE - 230V ELECTRICITY SUPPLY

Next: End

WEAK CAUSING OVERHEAT

PUMP

Next: End

PUMP OVERRUN FOR OVERHEATING

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

OVERHEATING

KIT - BY-PASS

Next: End

NO POWER TO PUMP

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NO POWER TO PUMP OVERHEAT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E10 FAULT CODE

BURNER

Next: End

E10 FAULT CODE

FLUE

Next: End

FUSE F1 MAIN PCB

FUSE F1 MAIN PCB

Next: End

BAFFLING

CONDENSATE TRAP OR PIPEWORK

Next: End

BAFFLING

MANIFOLD - AIR

Next: End

IGNITES BUT BAFFLES

AIR BOX ASSEMBLY

Next: End

BAFFLING

BURNER

Next: End

BAFFLING

CONDENSING HEAT EXCHANGER

Next: End

NOT ESTABLISHING

AIR BOX ASSEMBLY

Next: End

NOT RECTIFYING

BURNER

Next: End

NOT ESTABLISHING

ELECTRODE DETECTION AND BURNER GAP

Next: End

TO FLOW TURBINE

SENSORS - CABLE

Next: End

NO POWER TO DISPLAY

WIRING - PCB - MAIN ELECTRONIC CONTROL TO - PCB (DISPLAY)

Next: End

E09 FAULT CODE

FLUE TEMPERATURE PROBE NTC - SAFETY THERMAL FUSE (FUSE PART)

Next: End

BLOWING FUSES - PUMP

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT TRANSMITTING CH DEMAND

CABLE - 230V ELECTRICITY SUPPLY

Next: End

POWER NOT GETTING TO TERMINAL STRIP FROM DISPLAY

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT RECOGNISING CH DEMAND

CABLE - DUMMY JUMPER / CLOCK

Next: End

NOT TRANSMITTING CH DEMAND 2

CABLE - 230V ELECTRICITY SUPPLY

Next: End

POWER NOT GETTING TO TERMINAL STRIP FROM DISPLAY 2

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT RECOGNISING CH DEMAND 2

CABLE - DUMMY JUMPER / CLOCK

Next: End

FROM INCOMING TERMINAL TO MAIN PCB

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT TRANSMITTING CH DEMAND 3

CABLE - 230V ELECTRICITY SUPPLY

Next: End

POWER NOT GETTING TO TERMINAL STRIP FROM DISPLAY 3

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT RECOGNISING CH DEMAND 3

CABLE - DUMMY JUMPER / CLOCK

Next: End

NOT TRANSMITTING CH DEMAND 4

CABLE - 230V ELECTRICITY SUPPLY

Next: End

POWER NOT GETTING TO TERMINAL STRIP FROM DISPLAY 4

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT RECOGNISING CH DEMAND 4

CABLE - DUMMY JUMPER / CLOCK

Next: End

NOT TRANSMITTING CH DEMAND 5

CABLE - 230V ELECTRICITY SUPPLY

Next: End

POWER NOT GETTING TO TERMINAL STRIP FROM DISPLAY 5

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT RECOGNISING CH DEMAND 5

CABLE - DUMMY JUMPER / CLOCK

Next: End

TAP OPEN OR DHW DRAW OFF OPEN

TAP OPEN OR DHW DRAW OFF OPEN

Next: End

FIRING NO DEMAND

FLOW SWITCH - MAGNETIC (FLOW TURBINE)

Next: End

DEMAND WHEN SHOULDNT BE

SWITCH - FLOW - DHW

Next: End

FOR FROST PROTECTION

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

POSSIBLY FAULTY

FROST THERMOSTAT

Next: End

FIRING WITH NO CH DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

DHW COOL RADS COOL

EXTERNAL MIXING

Next: End

NOT SENSING PRESSURE

SWITCH - PRESSURE - PRIMARY CIRCUIT

Next: End

E04 FAULT CODE

SENSORS - CABLE

Next: End

NOT FULLY OPEN

TAP 1/2 IN - DHW

Next: End

DHW FLOW RATE

WATER SUPPLY

Next: End

FAULT CODE 020

WATER INGRESS

Next: End

E25 AND E11 - INCORRECTLY READING FAULT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E25 AND E11 - SENDING VOLTAGE TO GAS VALVE AFTER DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BLOWING FUSES GAS VALVE SECTION

CABLE - 230V ELECTRICITY SUPPLY

Next: End

INCORRECT FAN PRESSURE

CONDENSATE TRAP OR PIPEWORK

Next: End

TO GAS VALVE

CABLE - 230V ELECTRICITY SUPPLY

Next: End

GAS VALVE NOT OPENING

COIL UNIT - GAS VALVE SIT

Next: End

NO DROP

FLUE

Next: End

INCORRECT FAN PRESSURE

FLUE

Next: End

PRESSURES CORRECT BUT NOT LIGHTING

ELECTRODE - IGNITION

Next: End

INCORRECT FAN PRESSURE

MANIFOLD - AIR

Next: End

NOT IGNITING

AIR BOX ASSEMBLY

Next: End

BLANK FOR CASE OFF

Z DIRECTION CHOICE OR CONTINUE

Next: End

INCORRECT FAN PRESSURE

CONDENSING HEAT EXCHANGER

Next: End

NOT IGNITING

ELECTRODE - IGNITION AND BURNER GAP

Next: End

PERFORMANCE TEST FAIL

MANIFOLD - AIR

Next: End

PERFORMANCE TEST FAIL

AIR BOX ASSEMBLY

Next: End

PERFORMANCE TEST FAIL

FLUE

Next: End

PERFORMANCE TEST FAIL

BURNER

Next: End

PERFORMANCE TEST FAIL

CONDENSING HEAT EXCHANGER

Next: End

FUSE F2 MAIN PCB

FUSE F2 MAIN PCB

Next: End

IGNITES BUT BAFFLES OUT

GAS RESTRICTOR

Next: End

NO IGNITION - NO DROP

GAS RESTRICTOR

Next: End

NO IGNITION WITH DROP

GAS RESTRICTOR

Next: End

FAN SUPPLY E05 FAULT CODE

CABLE - 230V ELECTRICITY SUPPLY

Next: End

DC FAN SECTION E05 FAULT CODE

SENSORS - CABLE

Next: End

NO PERMANENT DC TO FAN E05 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E05 FAN RUNNING WITH DEMAND

SENSORS - CABLE

Next: End

E08

PCB - OUTDOOR PARAMETER

Next: End

E08

OUTDOOR SENSOR

Next: End

KEEPING BOILER TEMP TOO LOW - NO SENSOR

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

KEEPING BOILER TEMP TOO LOWE08

OUTDOOR SENSOR

Next: End

E05 RUNNING WITH DEMAND

FAN

Next: End

BAFFLING AT IGNITION

FLUE

Next: End

PERFORMANCE ANALYSIS

GAS RESTRICTOR

Next: End

BLANK FOR TYPE OF DIAGNOSTICS

Z DIRECTION CHOICE OR CONTINUE

Next: End

NO PERMANENT VOLTAGE TO FLOW TURBINE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

TO FLOW TURBINE NOT RECOGNISING DEMAND

SENSORS - CABLE

Next: End

NOT SPINNING FREELY

FLOW SWITCH - MAGNETIC (FLOW TURBINE)

Next: End

HOLDING FAN OFF

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

IGNITION ELECTRODE AND LEAD

ELECTRODE - IGNITION

Next: End

RECTIFICATION LEAD

SENSORS - CABLE

Next: End

NOT RECTIFYING

ELECTRODE DETECTION

Next: End

IGNITES BUT DOES NOT ESTABLISH

GAS INLET PRESSURE

Next: End

IGNITES BUT BAFFLES OUT

GAS INLET PRESSURE

Next: End

NOT SUPPLYING POWER TO DIVERTER FOR DHW

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

POWER TO DIVTERTER VALVE DHW

CABLE - 230V ELECTRICITY SUPPLY

Next: End

DHW TOO HOT

TEMPERATURE PROBE - OUTLET

Next: End

DHW TOO COOL

TEMPERATURE PROBE - OUTLET

Next: End

DHW TOO COOL

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

WEAK CAUSING NOISY

PUMP

Next: End

DHW TOO COOL DHW HOT AND COLD

TEMPERATURE PROBE - OUTLET

Next: End

DHW HOT AND COLD

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

NOT PREHEATING PROPERLY

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

OVERRUNS NOT WORKING

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

ANTI CYCLE DELAY

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

UNSATISFACTORY AT MAXIMUM LOAD

GAS INLET PRESSURE

Next: End

NOT SENDING POWER TO DIVERTER ON CH

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

POWER TO DIVERTER VALVE CH

CABLE - 230V ELECTRICITY SUPPLY

Next: End

NOT OPENING TO RADS

KIT - DIVERTER VALVE

Next: End

KEEPING BOILER TEMP TOO LOW

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

BOILER NOISY ON CH

TAP 3/4 IN - CH

Next: End

NOISY BOILER ON CH

Next: End

NOISY BOILER ON CH

KIT - BY-PASS

Next: End

FOR SAFETY WARNING

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLOWING FUSES

COIL UNIT - GAS VALVE SIT

Next: End

E06 FAULT CODE

PROBE SPRING MOUNTING TEMPERATURE - FLOW

Next: End

E07 FAULT CODE

TEMPERATURE PROBE - OUTLET

Next: End

E09 FAULT CODE

FLUE TEMPERATURE PROBE NTC - SAFETY THERMAL FUSE (THERMISTOR COMPONENT)

Next: End

E69 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E19 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BLANK FOR BOILER CONFIGURATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

E10 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

FUSE BLOWN

MAIN ELECTRONIC CONTROL - IGNITION PCB - FUSE INVESTIGATION

Next: End

BLOWING FUSES

ACTUATOR DIVERTER VALVE

Next: End

BLOWING FUSES

FAN

Next: End

BLOCKED

PIPE - CONNECTION EXPANSION VESSEL

Next: End

NOT RESETTING FROM OVERHEAT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

OVERHEAT STAT SECTION

SENSORS - CABLE

Next: End

NOT MOVING TO DHW POSITION FOR OVERHEAT

ACTUATOR DIVERTER VALVE

Next: End

BLANK FOR FAULT CODES

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAULTY WINDINGS

PUMP

Next: End

DHW TOO COOL

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

RESTRICTED OR BLOCKED LOW DHW TEMP

HEAT EXCHANGER DHW

Next: End

RESTRICTED CAUSING POOR DHW

CONDENSING HEAT EXCHANGER

Next: End

DHW TOO COOL DHW HOT AND COLD

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

RESTRICTED OR BLOCKED DHW HOT AND COLD

HEAT EXCHANGER DHW

Next: End

DHW HOT AND COLD

CONDENSING HEAT EXCHANGER

Next: End

NO MAINS SUPPLY

Next: End

E06 AND E12 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BLANK FOR MAINS FUSE FURTHER INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

RESTRICTED CAUSING POOR DHWOVERHEAT INVESTIGATION

CONDENSING HEAT EXCHANGER

Next: End

BLANK FOR OVERHEAT SECTION

Z DIRECTION CHOICE OR CONTINUE

Next: End

OUT OF CALIBRATION

THERMOSTAT 105 DEG C OVERHEAT

Next: End

NOT SHUTTING DOWN AT TEMP

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BLANK FOR FUSE F1 MAIN PCB INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAULTY WINDINGS OVERHEAT

PUMP

Next: End

E10 FAULT CODE

CONDENSING HEAT EXCHANGER

Next: End

ADJUSTED INCORRECTLY BAFFLING

GAS VALVE

Next: End

NOT RECOGNISING RECTIFICATION

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

MAKING DISPLAY BLANK

SWITCH - FLOW - DHW

Next: End

PCB DISPLAY

CONTROL PANEL ELECTRONIC PCB

Next: End

PCB MAIN

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E09 FAULT CODE

SENSORS - CABLE

Next: End

BLOWING FUSES

PUMP

Next: End

NO POWER TO CH CIRCUIT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT FIRING FOR CH

Next: End

NOT RECOGNISING CH DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT SENDING CH DEMAND TO MAIN PCB

CONTROL PANEL ELECTRONIC PCB

Next: End

NOT SENDING TIMER DEMAND TO MAIN PCB

CONTROL PANEL ELECTRONIC PCB

Next: End

NO POWER TO CH CIRCUIT 2

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING CH DEMAND 2

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT SENDING CH DEMAND TO MAIN PCB 2

CONTROL PANEL ELECTRONIC PCB

Next: End

NOT SENDING TIMER DEMAND TO MAIN PCB 2

CONTROL PANEL ELECTRONIC PCB

Next: End

NO POWER TO CH CIRCUIT 3

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING CH DEMAND 3

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT SENDING CH DEMAND TO MAIN PCB 3

CONTROL PANEL ELECTRONIC PCB

Next: End

NOT SENDING TIMER DEMAND TO MAIN PCB 3

CONTROL PANEL ELECTRONIC PCB

Next: End

NO POWER TO CH CIRCUIT 4

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING CH DEMAND 4

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT SENDING CH DEMAND TO MAIN PCB 4

CONTROL PANEL ELECTRONIC PCB

Next: End

NOT SENDING TIMER DEMAND TO MAIN PCB 4

CONTROL PANEL ELECTRONIC PCB

Next: End

NO POWER TO CH CIRCUIT 5

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING CH DEMAND 5

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT SENDING CH DEMAND TO MAIN PCB 5

CONTROL PANEL ELECTRONIC PCB

Next: End

NOT SENDING TIMER DEMAND TO MAIN PCB 5

CONTROL PANEL ELECTRONIC PCB

Next: End

FIRING WITH NO DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

CORRECTLY ACTIVATED

FROST PROTECTION

Next: End

INCORRECTLY ACTIVATING FROST PROTECTION

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

FIRING NO FROST PROTECTION DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E04 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

LOW FLOW RATE

HEAT EXCHANGER DHW

Next: End

RESTRICTING FLOW

LIMITER - FLOW 10 LITRES/MIN

Next: End

RESTRICTED OR BLOCKED

FLOW SWITCH - MAGNETIC (FILTER)

Next: End

RESTRICTED BLOCKED OR JAMMED

FLOW SWITCH - MAGNETIC (FLOW TURBINE)

Next: End

E25 AND E11 - STUCK IN FAULT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E25 AND E11

ELECTRODE DETECTION

Next: End

E25 AND E11 - READING FLAME AFTER CUTOFF

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E25 AND E11 - NOT SHUTTING

GAS VALVE

Next: End

SPARKS BUT DOES NOT IGNITE

GAS INLET PRESSURE

Next: End

NO POWER TO GAS VALVE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT LIGHTING WRONG MIX

GAS VALVE

Next: End

BLANK FOR FUSE F2 MAIN PCB INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAILING PERFORMANCE TEST

COMBUSTION ADJUSTMENT

Next: End

MECHANICALLY FAILED

GAS VALVE

Next: End

E05 NOT RUNNING

FAN

Next: End

NO AC POWER TO FAN E05 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NO DC DEMAND E05 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

FAN RUNNING CONTINUOUSLY 2 E05 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E05 FAN RUNNING WITH DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E04

PRESSURE GAUGE

Next: End

E04

SYSTEM PRESSURE

Next: End

NOISH CH

SYSTEM PRESSURE

Next: End

NOISY CH

PRESSURE GAUGE

Next: End

NOISY KETTLING ON DHW

SYSTEM PRESSURE

Next: End

NOISY DHW

PRESSURE GAUGE

Next: End

OVERHEAT INVESTIGATION

SYSTEM PRESSURE

Next: End

OVERHEAT

PRESSURE GAUGE

Next: End

E08 - NO SENSOR

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E08 - WITH SENSOR

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E08

SENSORS - CABLE

Next: End

KEEPING BOILER TEMP TOO LOW - WITH SENSOR

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

HOLDING FAN OFF

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E05 - NEUTRAL FAULT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING DHW DEMAND

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

NOT RECOGNISING DEMAND

SWITCH - FLOW - DHW

Next: End

NOT SPARKING

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

PASSING TO RADS ON HW

KIT - DIVERTER VALVE

Next: End

NOT MOVING TO DHW POSITION

ACTUATOR DIVERTER VALVE

Next: End

DHW TOO HOT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BOILER NOISY

HEAT EXCHANGER DHW

Next: End

NOISY ON DHW

CONDENSING HEAT EXCHANGER

Next: End

NO GOING TO CH POSITION

ACTUATOR DIVERTER VALVE

Next: End

ALLOWING BOILER TO GET TOO HOT

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

RESTRICTED BLOCKED CAUSING CH NOISE

CONDENSING HEAT EXCHANGER

Next: End

NOISE ON CH

Next: End

E06 FAULT CODE

SENSORS - CABLE

Next: End

E07 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

E07 FAULT CODE

SENSORS - CABLE

Next: End

E09 FAULT CODE

MAIN ELECTRONIC CONTROL - IGNITION PCB

Next: End

BLANK FOR CONFIGURATION 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

SYSTEM PRESSURE RISES EXCESSIVELY

CHARACTERISTIC TEST FROM OPERATION CH

Next: p1149

BOILER FIRES WITH NO DEMAND OR PUMP RUNNING CONTINUOUSLY

CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION

Next: p1858

FAULT CODE SHOWN

CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION

Next: p1375

DISPLAY ILLUMINATED WITH NO FAULT CODE SHOWING BUT FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION

Next: p2077

DISPLAY DOES NOT ILLUMINATE

CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION

Next: p156

DIFFERENTIAL STILL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: !p1553

BOILER DOES NOT RESPOND TO CENTRAL HEATING DEMAND

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: p1761

DIFFERENTIAL STILL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: !p1577

BOILER DOES NOT RESPOND TO CENTRAL HEATING DEMAND

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: p1799

DIFFERENTIAL STILL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: !p1626

BOILER DOES NOT RESPOND TO CENTRAL HEATING DEMAND

CHARACTERISTIC TEST FROM DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

Next: p1818

BOILER OVERHEATS BEFORE 90 DEGREES

CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMP?

Next: !p1644

BOILER CONTINUES TO HEAT PAST 90 DEGREES

CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMP?

Next: !p1646

VOLTAGE IS NOT PRESENT ON PIN 5 (BUT PRESENT ON PIN 9)

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: p1775

VOLTAGE IS NOT PRESENT ON PIN 9

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: !p1777

VOLTAGE IS NOT PRESENT ON PIN 5 (BUT PRESENT ON PIN 9)

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: p1794

VOLTAGE IS NOT PRESENT ON PIN 9

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: !p1796

VOLTAGE IS NOT PRESENT ON PIN 5 (BUT PRESENT ON PIN 9)

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: p1813

VOLTAGE IS NOT PRESENT ON PIN 9

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: !p1815

VOLTAGE IS NOT PRESENT ON PIN 5 (BUT PRESENT ON PIN 9)

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: p1832

VOLTAGE IS NOT PRESENT ON PIN 9

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: !p1834

VOLTAGE IS NOT PRESENT ON PIN 5 (BUT PRESENT ON PIN 9)

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: p1853

VOLTAGE IS NOT PRESENT ON PIN 9

CHARACTERISTIC TEST FROM VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

Next: !p1855

AF SHOWING ON DISPLAY

CHARACTERISTIC TEST FROM OBSERVATION WHAT IS SHOWING ON DISPLAY

Next: p1861

bP SHOWING ON DISPLAY

CHARACTERISTIC TEST FROM OBSERVATION WHAT IS SHOWING ON DISPLAY

Next: p1863

DHW DEMAND SHOWING ON DISPLAY

CHARACTERISTIC TEST FROM OBSERVATION WHAT IS SHOWING ON DISPLAY

Next: p1865

FLOW LIMITER RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION TURBINE, FILTER AND FLOW LIMITER

Next: !p1941

FILTER RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION TURBINE, FILTER AND FLOW LIMITER

Next: !p1943

TURBINE RESTRICTED, BLOCKED OR JAMMED

CHARACTERISTIC TEST FROM INSPECTION TURBINE, FILTER AND FLOW LIMITER

Next: !p1945

PUMP AND FAN RUN BUT SPARKING DOES NOT OCCUR THEN FAULT REAPPEARS

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESET - FALSE FLAME

Next: p1951

FAULT CODE REAPPEARS WITHOUT PUMP OR FAN RUNNING

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESET - FALSE FLAME

Next: !p1953

GAS INLET PRESSURE UNSATISFACTORY

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: !p1981

GAS INLET PRESSURE DOES NOT DIP DURING SPARKING

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: p1983

PRESSURE LOW OR AIR IN SYSTEM

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2106

PRESSURE OK BUT DOES NOT INCREASE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2105

PRESSURE LOW OR AIR IN SYSTEM

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2109

PRESSURE OK BUT DOES NOT INCREASE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2111

PRESSURE LOW OR AIR IN SYSTEM

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2114

PRESSURE OK BUT DOES NOT INCREASE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2118

FAN RUNS CONTINUOUSLY

CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION

Next: p2088

PRESSURE LOW OR AIR IN SYSTEM

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2121

PRESSURE OK BUT DOES NOT INCREASE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION SYSTEM PRESSURE AND AIR

Next: !p2123

SPARKING DOES NOT OCCUR

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p294

SPARKING OCCURS BUT BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p1975

BURNER IGNITES BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p1136

BURNER IGNITES BUT BAFFLES OUT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p344

DHW TOO HOT

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p424

DHW TOO COOL RADS REMAIN COOL WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p1880

DHW TOO COOL AND RADS BEGIN TO HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p428

BOILER NOISY (KETTLING)

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p501

DHW RUNS HOT AND COLD

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p522

BOILER STILL NOISY

CHARACTERISTIC TEST FROM OBSERVATION OPERATION CH (NOISY)

Next: !p505

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM OBSERVATION OPERATION CH (NOISY)

Next: p1780

BOILER UP TO TEMP RADS COLD

CHARACTERISTIC TEST FROM OPERATION CH

Next: p1282

BOILER AND SYSTEM TEMPERATURE LOW

CHARACTERISTIC TEST FROM OPERATION CH

Next: p645

BOILER NOISY

CHARACTERISTIC TEST FROM OPERATION CH

Next: p679

DIFFERENTIAL INCORRECT OR LOCAL NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISY

Next: !p689

DIFFERENTIAL OK SYSTEM NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISY

Next: !p691

RESISTANCE THERMISTOR FLUE

DISCONNECT PLUG FOR THERMAL FUSE / FLUE THERMISTOR

Next: p1099, !f1100

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p1103, !f1108

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR CN4 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE

Next: !p1116, !f1117

OBSERVATION RESET APPLIANCE - OVERHEAT

ALLOW APPLIANCE TO COOL

Next: p1214, f1162

RESISTANCE OVERHEAT THERMOSTAT AND HARNESS

REMOVE CONNECTOR CN6 FROM THE MAIN PCB

Next: !p1163, f1164

RESISTANCE OVERHEAT THERMOSTAT

REMOVE THE CONNECTORS (BLACK WIRES) FROM THE OVERHEAT THERMOSTAT

Next: !p1165, !f1166

VOLTAGE TO DIVERTER VALVE (DHW)

{GAINPCBACS}

Next: p1216, !f1217

DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE P

Next: !p1551, ?1552, ?1554

RESISTANCE FUSE MAINS

REMOVE THE MAINS FUSE FROM ITS HOLDER

Next: !p158, f159

DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE P

Next: !p1575, ?1576, ?1578

VOLTAGE PUMP AT PCB

Next: p1606, !f1653

DIFFERENTIAL TEMPERATURE PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE P

Next: !p1624, ?1625, ?1627

RESISTANCE HARNESS FLOW TURBINE

REMOVE CONNECTOR CN12 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE FLOW TURBINE ASSEMBLY

Next: !p1727, !f1728

RESISTANCE HARNESS FLAT DISPLAY PCB

DISCONNECT CONNECTOR CN8 FROM THE MAIN PCB
DISCONNECT CONNECTOR CN2 FROM THE DISPLAY PCB

Next: !p1731, !f1732

RESISTANCE HARNESS MAIN PCB TO DISPLAY PCB (MAINS)

REMOVE CONNECTOR CN15 FROM THE MAIN PCB
REMOVE CONNECTOR CN4 FROM THE DISPLAY PCB

Next: !p1768, !f1769

RESISTANCE HARNESS MAIN PCB TO DISPLAY PCB (MAINS)

REMOVE CONNECTOR CN15 FROM THE MAIN PCB
REMOVE CONNECTOR CN4 FROM THE DISPLAY PCB

Next: !p1787, !f1788

RESISTANCE HARNESS MAIN PCB TO DISPLAY PCB (MAINS)

REMOVE CONNECTOR CN15 FROM THE MAIN PCB
REMOVE CONNECTOR CN4 FROM THE DISPLAY PCB

Next: !p1806, !f1807

RESISTANCE HARNESS MAIN PCB TO DISPLAY PCB (MAINS)

REMOVE CONNECTOR CN15 FROM THE MAIN PCB
REMOVE CONNECTOR CN4 FROM THE DISPLAY PCB

Next: !p1825, !f1826

VOLTAGE EXTERNAL CONTROLS RECEIVE AT DISPLAY PCB

GAIN ACCESS TO DISPLAY PCB CONNECTIONS

Next: p1840, f1841

RESISTANCE HARNESS MAIN PCB TO DISPLAY PCB (MAINS)

REMOVE CONNECTOR CN15 FROM THE MAIN PCB
REMOVE CONNECTOR CN4 FROM THE DISPLAY PCB

Next: !p1846, !f1847

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: !p1874, !f1875

OBSERVATION WATER SUPPLY

Next: p1935, !f1946

OBSERVATION BOILER RESET - FALSE FLAME

ALLOW APPLIANCE TO COOL

Next: p1949, ?1950, ?1952

VOLTAGE GAS VALVE AFTER DEMAND

Next: !p1962, !f1963

RESISTANCE HARNESS GAS VALVE

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE GAS VALVE CONNECTOR

Next: !p1986, !f1987

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p2007, !f2008

VOLTAGE AC FAN AT FAN

NO DEMANDS

Next: !p2080, f2081

RESISTANCE HARNESS FAN AC

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE AC FAN CONNECTOR (3 WIRE) FROM THE FAN

Next: !p2082, !f2083

RESISTANCE HARNESS FAN DC

REMOVE CONNECTOR CN5 FROM THE MAIN PCB
REMOVE THE FAN DC CONNECTOR (4 WIRE) FROM THE FAN

Next: !p2086, !f2087

RESISTANCE OUTDOOR SENSOR

GAIN ACCESS TO MAIN

Next: !p2130, !f2131

VOLTAGE DC FAN NEUTRAL

Next: !p2154, !f2153

VOLTAGE FLOW TURBINE DEMAND

{GAINPCBACS}
EASE CONNECTOR SLIGHTLY OFF THE PCB TO EXPOSE TEST POINT

Next: !p259, f260

VOLTAGE FLOW TURBINE PERMANENT

{GAINPCBACS}

Next: p262, !f261

VOLTAGE PUMP AT PCB

Next: p1269, !f1649

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: p1596, !f289

VOLTAGE TO DIVERTER VALVE (DHW)

{GAINPCBACS}

Next: p435, !f436

VOLTAGE TO DIVERTER VALVE (CH)

{GAINPCBACS}

Next: p634, !f635

RESISTANCE PUMP AND HARNESS FOR FUSE INVESTIGATION

REMOVE CONNECTOR CN2 FROM THE INTERFACE PCB

Next: p725, f727

RESISTANCE HARNESS PUMP

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE CONNECTION FROM THE PUMP ASSEMBLY

Next: !p1760, !f1759

RESISTANCE HARNESS FAN AC

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE AC FAN CONNECTOR (3 WIRE) FROM THE FAN

Next: !p1118, !f1119

OBSERVATION SYSTEM PRESSURE AND AIR

NO DEMANDS

Next: p1917, ?2102, ?2104

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE CONNECTOR CN6 FROM THE MAIN PCB

Next: !p1593, f760

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: !p764, !f765

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR CN12 FROM THE MAIN PCB

Next: !p767, f768

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p769, !f770

RESISTANCE THERMISTOR FLUE, THERMAL FUSE AND HARNESS

REMOVE CONNECTOR CN11 FROM THE MAIN PCB

Next: !p772, f773

RESISTANCE THERMISTOR FLUE

DISCONNECT PLUG FOR THERMAL FUSE / FLUE THERMISTOR

Next: p774, !f775

RESISTANCE HARNESS FAN DC

REMOVE CONNECTOR CN5 FROM THE MAIN PCB
REMOVE THE FAN DC CONNECTOR (4 WIRE) FROM THE FAN

Next: p873, !f2096

TEMPERATURE EMISSIONS

Next: !p1101, f1102

INSPECTION AIR BOX ASSEMBLY

REMOVE THE AIR TUBE FROM THE AIR BOX'S AIR INTAKE

Next: p1104, !f1109

INSPECTION CONDENSATE PIPE

Next: p1654, !f1110

RESISTANCE DIVERTER VALVE MOTOR AND HARNESS

REMOVE CONNECTOR CN4 FROM THE MAIN PCB

Next: !p1114, f1115

INSPECTION CONDENSATE PIPE

Next: p308, !f1146

PRESSURE EXPANSION VESSEL

RELEASE PRIMARY HEATING CIRCUIT PRESSURE

Next: !p1150, !f1151

OBSERVATION DIVERTER VALVE MOTOR SPINDLE DHW

REMOVE THE DIVERTER VALVE HEAD FROM THE DIVERTER VALVE BODY

Next: p1220, f1215

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR CN4 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE

Next: !p1218, !f1219

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: p1601, !f1222

RESISTANCE HARNESS PUMP

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE CONNECTION FROM THE PUMP ASSEMBLY

Next: !p1407, !f1270

FAULT CODES

Next: !p1376, !f1377

OBSERVATION SYSTEM PRESSURE AND AIR

NO DEMANDS

Next: p430, ?2113, ?2117

OBSERVATION SYSTEM PRESSURE AND AIR

NO DEMANDS

Next: p1459, ?2108, ?2110

LIMPET CHECK PUMP

Next: p680, !f1472

RESISTANCE THERMISTOR FLUE

DISCONNECT PLUG FOR THERMAL FUSE / FLUE THERMISTOR

Next: p1545, !f1546

LIMPET CHECK PUMP

Next: p1547, !f1548

DIFFERENTIAL TEMPERATURE DHW HEAT EXCHANGER

ATTACH TEMPERATURE P

Next: !p1549, f1550

VOLTAGE MAINS POWER

{GAINPCBACS}

Next: p162, f157

RESISTANCE THERMISTOR FLUE

DISCONNECT PLUG FOR THERMAL FUSE / FLUE THERMISTOR

Next: p1569, !f1570

LIMPET CHECK PUMP

Next: p1571, !f1572

DIFFERENTIAL TEMPERATURE DHW HEAT EXCHANGER

ATTACH TEMPERATURE P

Next: !p1573, f1574

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p2150, !f1598

OBSERVATION SYSTEM PRESSURE AND AIR

NO DEMANDS

Next: p1602, ?2120, ?2122

OBSERVATION PUMP RUNNING

Next: p1604, f1605

LIMPET CHECK PUMP

Next: p1616, !f1617

RESISTANCE HARNESS PUMP

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE CONNECTION FROM THE PUMP ASSEMBLY

Next: !p1651, !f1613

OBSERVATION FAN AND PUMP OVERRUN

Next: p1618, !f1619

INSPECTION BYPASS INTERNAL

BOILER PRIMARY CIRCU

Next: p1620, !f1621

RESISTANCE FUSE F1 MAIN PCB

REMOVE FUSE F1 FROM THE MAIN PCB

Next: p163, f164

DIFFERENTIAL TEMPERATURE DHW FOR OVERHEAT INVESTIGATION

ATTACH TEMPERATURE P

Next: p1622, f1623

OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMP?

BOILER CH THERMOSTAT SET TO MAX
ATTACH TEMPERATURE PROBES AS PER THE RED ARROWS

Next: !p1641, ?1643, ?1645

RESISTANCE FUSE F2 MAIN PCB

REMOVE FUSE F2 FROM THE MAIN PCB

Next: p178, f200

INSPECTION BURNER

REMOVE THE FAN & BUR

Next: p1655, !f1656

INSPECTION FLUE ASSEMBLY

Next: !p1657, !f1658

INSPECTION CONDENSATE PIPE

Next: p1671, !f1672

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p1673, !f1674

INSPECTION AIR BOX ASSEMBLY

REMOVE THE AIR TUBE FROM THE AIR BOX'S AIR INTAKE

Next: p2155, !f1676

INSPECTION BURNER

REMOVE THE FAN & BUR

Next: p1677, !f1678

INSPECTION FLUEWAYS

REMOVE FAN AND BURNER ASSEMBLY

Next: !p1679, !f1680

INSPECTION AIR BOX ASSEMBLY

REMOVE THE AIR TUBE FROM THE AIR BOX'S AIR INTAKE

Next: p1693, !f1694

INSPECTION BURNER

REMOVE THE FAN & BUR

Next: p1695, !f1696

INSPECTION FLAME RECTIFICATION ELECTRODE AND BURNER GAP

REMOVE COMBUSTION DOOR ASSEMBLY COMPLETE WITH BURNER

Next: !p1697, !f1698

OBSERVATION FLOW TURBINE DISCONNECTION

REMOVE CONNECTOR CN12 FROM THE PCB AND MAKE SAFE
NO DEMANDS

Next: p1725, f1726

VOLTAGE DISPLAY PCB AT HARNESS

UNCLIP DISPLAY PCB AND WEDGE IN POSITION AS SHOWN
NO DEMANDS

Next: !p1729, f1730

VOLTAGE EXTERNAL CONTROLS RECEIVE AT DISPLAY PCB

GAIN ACCESS TO DISPLAY PCB CONNECTIONS

Next: p1762, f1763

VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

UNCLIP AND FLIP DISPLAY PCB OVER THEN SECURE IT IN PLACE WITH A SCREW AS SHOWN

Next: !p1772, ?1774, ?1776

RESISTANCE HARNESS DISPLAY PCB TO TERMINAL STRIP

REMOVE CONNECTOR CN5 FROM THE DISPLAY PCB

Next: !p1770, !f1771

RESISTANCE HARNESS CLOCK / LINK

DISCONNECT CN1 FROM THE DISPLAY PCB

Next: !p1778, !f1779

RESISTANCE HARNESS MAINS INTO PCB

REMOVE CONNECTOR CN1 FROM THE MAIN PCB

Next: p1724, !f180

VOLTAGE EXTERNAL CONTROLS RECEIVE AT DISPLAY PCB

GAIN ACCESS TO DISPLAY PCB CONNECTIONS

Next: p1781, f1782

VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

UNCLIP AND FLIP DISPLAY PCB OVER THEN SECURE IT IN PLACE WITH A SCREW AS SHOWN

Next: !p1791, ?1793, ?1795

RESISTANCE HARNESS DISPLAY PCB TO TERMINAL STRIP

REMOVE CONNECTOR CN5 FROM THE DISPLAY PCB

Next: !p1789, !f1790

RESISTANCE HARNESS CLOCK / LINK

DISCONNECT CN1 FROM THE DISPLAY PCB

Next: !p1797, !f1798

VOLTAGE EXTERNAL CONTROLS RECEIVE AT DISPLAY PCB

GAIN ACCESS TO DISPLAY PCB CONNECTIONS

Next: p1800, f1801

VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

UNCLIP AND FLIP DISPLAY PCB OVER THEN SECURE IT IN PLACE WITH A SCREW AS SHOWN

Next: !p1810, ?1812, ?1814

RESISTANCE HARNESS DISPLAY PCB TO TERMINAL STRIP

REMOVE CONNECTOR CN5 FROM THE DISPLAY PCB

Next: !p1808, !f1809

RESISTANCE HARNESS CLOCK / LINK

DISCONNECT CN1 FROM THE DISPLAY PCB

Next: !p1816, !f1817

VOLTAGE EXTERNAL CONTROLS RECEIVE AT DISPLAY PCB

GAIN ACCESS TO DISPLAY PCB CONNECTIONS

Next: p1819, f1820

VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

UNCLIP AND FLIP DISPLAY PCB OVER THEN SECURE IT IN PLACE WITH A SCREW AS SHOWN

Next: !p1829, ?1831, ?1833

RESISTANCE HARNESS DISPLAY PCB TO TERMINAL STRIP

REMOVE CONNECTOR CN5 FROM THE DISPLAY PCB

Next: !p1827, !f1828

RESISTANCE HARNESS CLOCK / LINK

DISCONNECT CN1 FROM THE DISPLAY PCB

Next: !p1835, !f1836

VOLTAGE DISPLAY PCB TO MAIN PCB (CH DEMAND)

UNCLIP AND FLIP DISPLAY PCB OVER THEN SECURE IT IN PLACE WITH A SCREW AS SHOWN

Next: !p1850, ?1852, ?1854

RESISTANCE HARNESS DISPLAY PCB TO TERMINAL STRIP

REMOVE CONNECTOR CN5 FROM THE DISPLAY PCB

Next: !p1848, !f1849

RESISTANCE HARNESS CLOCK / LINK

DISCONNECT CN1 FROM THE DISPLAY PCB

Next: !p1856, !f1857

OBSERVATION WHAT IS SHOWING ON DISPLAY

Next: p1859, ?1860, ?1862, ?1864

VOLTAGE EXTERNAL CONTROLS AT TERMINAL STRIP FIRING WITH NO DEMAND

GAIN ACCESS TO THE APPLIANCE TERMINAL STRIP
NO DEMANDS

Next: !p1878, !f1879

VOLTAGE FROST THERMOSTAT

GAIN ACCESS TO THE APPLIANCE TERMINAL STRIP
NO DEMANDS

Next: !p1876, !f1877

TEMPERATURE APPLIANCE

Next: !p1872, f1873

OBSERVATION ISOLATE DHW

TURN DHW ISOLATION OFF

Next: p1866, !f1867

OBSERVATION REMOVE FLOW SENSOR ASSEMBLY

REMOVE THE FLOW SENS

Next: p1868, !f1869

OBSERVATION REMOVE FLOW SENSOR CONNECTOR

NO DEMANDS
REMOVE THE CONNECTOR FROM THE FLOW SENSOR
ASSEMBLY AND MAKE SAFE

Next: !p1870, !f1871

OBSERVATION EXTERNAL MIXING

Next: p426, !f1915

RESISTANCE PRESSURE SWITCH

DISCONNECT LEADS FROM WATER PRESSURE SWITCH

Next: p1918, !f1919

RESISTANCE HARNESS PRESSURE SWITCH

REMOVE CONNECTOR CN10 FROM THE PCB
REMOVE WIRES FROM PRESSURE SWITCH

Next: !p1920, !f1921

INSPECTION ISOLATION VALVE DHW

Next: p1936, !f1937

INSPECTION TURBINE, FILTER AND FLOW LIMITER

ISOLATE THE COLD MAI

Next: !p1938, ?1940, ?1942, ?1944

OBSERVATION FLAME SHUT OFF DELAY

ENSURE NO CH DEMAND

Next: !p1960, f1961

INSPECTION PCB AND CONNECTIONS

{GAINPCBACS}

Next: p1954, !f1955

OBSERVATION DISCONNECT RECTIFICATION LEAD

DISCONNECT RECTIFICATION LEAD FROM INLINE CONNECTOR AND MAKE SAFE

Next: !p1956, !f1957

RESISTANCE HARNESS GAS VALVE

REMOVE CONNECTOR CN2 FROM THE MAIN PCB
REMOVE THE GAS VALVE CONNECTOR

Next: p726, !f1974

INSPECTION CONDENSATE PIPE

Next: p1976, !f1977

PRESSURE GAS INLET AND DROP

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p1978, ?1980, ?1982

INSPECTION FLUE ASSEMBLY

Next: p1992, !f1993

VOLTAGE GAS VALVE

Next: p1984, f1985

RESISTANCE GAS VALVE SOLENOID

REMOVE THE CONNECTOR FROM THE GAS VALVE

Next: p1988, !f1989

INSPECTION FLUE ASSEMBLY

Next: p2030, !f1991

INSPECTION IGNITION ELECTRODE AND LEAD

REMOVE THE IGNITION ELECTRODE AND LEAD ASSEMBLY

Next: p1994, !f1995

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p1996, !f1997

INSPECTION AIR BOX ASSEMBLY

REMOVE THE AIR TUBE FROM THE AIR BOX'S AIR INTAKE

Next: p2033, !f1999

INSPECTION BURNER

REMOVE THE FAN & BUR

Next: p2000, !f2001

INSPECTION FLUEWAYS

REMOVE FAN AND BURNER ASSEMBLY

Next: p2002, !f2003

INSPECTION IGNITION ELECTRODE AND BURNER GAP

REMOVE FAN AND BURNER ASSEMBLY

Next: !p2004, !f2005

INSPECTION AIR BOX ASSEMBLY

REMOVE THE AIR TUBE FROM THE AIR BOX'S AIR INTAKE

Next: p2009, !f2010

INSPECTION FLUE ASSEMBLY

Next: p2168, !f2012

INSPECTION BURNER

REMOVE THE FAN & BUR

Next: p2013, !f2014

INSPECTION FLUEWAYS

REMOVE FAN AND BURNER ASSEMBLY

Next: p2018, !f2016

OBSERVATION CAN COMBUSTION BE ADJUSTED

BOILER IN SERVICE MODE

Next: !p2019, !f2020

INSPECTION GAS RESTRICTOR

UNDO NUT AT TOP OF GAS VALVE

Next: p1675, !f2029

INSPECTION GAS RESTRICTOR

UNDO NUT AT TOP OF GAS VALVE

Next: !p2031, !f2032

INSPECTION GAS RESTRICTOR

UNDO NUT AT TOP OF GAS VALVE

Next: p1998, !f2041

OBSERVATION DISCONNECT FAN (DC)

UNPLUG 4 WIRE CONNECTOR FROM FAN

Next: p2078, f2079

VOLTAGE DC DEMAND AT FAN

RECONNECT 4 WIRE CONNECTOR AT FAN IF YOU HAVE NOT ALREADY DONE SO
NO DEMANDS

Next: !p2084, f2085

RESISTANCE HARNESS FAN DC

REMOVE CONNECTOR CN5 FROM THE MAIN PCB
REMOVE THE FAN DC CONNECTOR (4 WIRE) FROM THE FAN

Next: p2089, !f2090

VOLTAGE DC FAN PERMANENT AT FAN

NO DEMANDS

Next: p2091, !f2092

VOLTAGE DC FAN DEMAND AT FAN RUNNING CONTINUOUSLY

NO DEMANDS

Next: !p2093, !f2094

RESISTANCE OUTDOOR SENSOR AND HARNESS

REMOVE CONNECTOR CN12 FROM THE MAIN PCB

Next: !p2128, f2129

RESISTANCE OUTDOOR SENSOR AND HARNESS

REMOVE CONNECTOR CN12 FROM THE MAIN PCB

Next: !p2147, !f2148

INSPECTION FLUE ASSEMBLY

Next: p2021, !f2165

INSPECTION GAS RESTRICTOR

UNDO NUT AT TOP OF GAS VALVE

Next: p2011, !f2176

RESISTANCE HARNESS FLOW TURBINE

REMOVE CONNECTOR CN12 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE FLOW TURBINE ASSEMBLY

Next: p263, !f264

INSPECTION FLOW TURBINE

ISOLATE COLD MAINS TO APPLIANCE AND DRAIN AND DISCHARGE DHW CIRCUIT

Next: !p265, !f266

INSPECTION IGNITION ELECTRODE AND LEAD

REMOVE THE IGNITION ELECTRODE AND LEAD ASSEMBLY

Next: !p301, !f302

INSPECTION RECTIFICATION ELECTRODE AND LEAD

REMOVE THE RECTIFICA

Next: p303, !f307

RESISTANCE HARNESS RECTIFICATION

REMOVE CONNECTOR T2 FROM THE MAIN PCB

Next: p1692, !f306

PRESSURE GAS INLET

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p298, !f314

PRESSURE GAS INLET

ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p1670, !f358

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p447, !f443

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: p448, !f473

OBSERVATION DIVERTER VALVE MOTOR SPINDLE DHW

REMOVE THE DIVERTER VALVE HEAD FROM THE DIVERTER VALVE BODY

Next: !p433, f434

OBSERVATION OPERATION CH (NOISY)

BOILER CH THERMOSTAT SET TO MAX
INTERNAL TIMER TURNED ON / SET TO ON PERIOD (IF FITTED)

Next: !p503, ?504, ?506

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR CN4 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE

Next: !p437, !f438

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: p1544, !f474

LIMPET CHECK PUMP

Next: p1427, !f521

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: p523, !f524

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: p1568, !f526

OBSERVATION DIVERTER VALVE MOTOR SPINDLE CH

REMOVE THE DIVERTER VALVE HEAD FROM THE DIVERTER VALVE BODY

Next: p632, f633

INSPECTION DIVERTER VALVE BODY

REMOVE DIVERTER VALVE MOTOR FROM THE DIVERTER VALVE BODY

Next: p638, !f639

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR CN4 FROM THE MAIN PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE

Next: !p636, !f637

INSPECTION EXTERNAL BYPASS

Next: p640, !f641

INSPECTION BYPASS INTERNAL

BOILER PRIMARY CIRCU

Next: !p642, !f643

RESISTANCE THERMISTOR FLOW

REMOVE CONNECTOR FROM FLOW THERMISTOR

Next: p2142, !f647

INSPECTION EXTERNAL BYPASS

Next: p682, !f683

INSPECTION BYPASS INTERNAL

BOILER PRIMARY CIRCU

Next: p684, !f685

DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISY

BOILER CH THERMOSTAT

Next: !p686, ?688, ?690

RESISTANCE GAS VALVE FOR FUSE INVESTIGATION

REMOVE THE CONNECTOR FROM THE GAS VALVE

Next: p1964, !f728

RESISTANCE FAN AND HARNESS FOR FUSE INVESTIGATION

REMOVE CONNECTOR CN2 FROM THE MAIN PCB

Next: p1113, f729

RESISTANCE THERMAL FUSE

DISCONNECT PLUG FOR THERMAL FUSE / FLUE THERMISTOR

Next: !p1757, !f1758

VOLTAGE DC FAN HALL SENSOR AT FAN

Next: !p2100, f2151