Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
MAIN COMBI ECO / ECO ELITE / 105HE A
GLOBALLY REPLACED
BURNER IGNITES AND ESTABLISHES
{SELHWCHON}
OPERATION DHW
APPLIANCE DHW THERMO
OPERATION CH
{SELHWCHON}
CH THERMOSTAT SET TO MAX
OVERHEAT INVESTIGATION
OUT OF MODEL
E20 FAULT CODE
OUT OF MODEL
E50 FAULT CODE
OUT OF MODEL
E119 FAULT CODE
OUT OF MODEL
E125 FAULT CODE
OUT OF MODEL
E160 FAULT CODE
OUT OF MODEL
FUSE FURTHER INVESTIGATION
OUT OF MODEL
E168 FAULT CODE
E168 FAULT CODE
T
POWER UP
{SELHWCHON}
ENSURE THERE ARE NO DEMANDS
BOILER ENTERS STANDBY MODE
{SELHWCHON}
ENSUR
E164 FAULT CODE
OUT OF MODEL
INFORMATION INTELLIGENT PREHEAT
THE BOILER INCORPORA
OBSERVATION DHW DEMAND RECOGNISED
SELECTOR SWITCH ON HOT WATER
RUN DHW TAP AT 3 LITRES PER MINUTE
OBSERVATION CH DEMAND RECOGNISED
SELECTOR SWITCH ON DHW AND CH
APPLIANCE DHW THERMOSTAT TO MIN
SF OR P CALIBRATION FUNCTION
INTENTIONALLY BLANK - HEADER FOR FAULT COD
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
HEADER FOR QADAI FLOW THERMISTOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DHW SENSOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DIVERTER VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI SPARK GENERATOR RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
TEMP LOW
SENSOR - BOILER - SPARE
DC SECTION TO FAN FAULTY CAUSING FAN RUNNING CONTINUOUSLY
HARNESS - WIRING
LOW CAUSING E164
SYSTEM PRESSURE
BLOCKED/FAULTY CAUSING E164
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
E164
PUMP
POOR FLOW RATE
FLOW REGULATOR
FROST PROTECTION
SENSOR - NTC (DHW)
LEAK OR OPEN TAP MAKING FLOW SWITCH
HOT WATER TAP OR PIPEWORK
STUCK MADE
FLOW REGULATOR
FAULTY CASUING DEMAND WHEN NONE PRESENT
SENSOR - HALL EFFECT
DHW FLOW SENSOR SENSOR SECTION SHORTED GIVING DEMAND
HARNESS - WIRING
FROST PROTECTION
SENSOR - BOILER - SPARE
BLOWN
FUSE 3AMP
BLOWN
FUSE 2 AMP (LIVE)
BLOWN
FUSE 2 AMP (NEUTRAL)
ERRATIC TEMPERATURE DISPLAY
SENSOR - BOILER - SPARE
DC SECTION TO FAN FAULTY PREVENTING FAN RUNNING CAUSING E160
HARNESS - WIRING
E168
PUMP
SOLENOID CAUSING E168
GAS VALVE
CAUSING E168
MOTOR - 3 WAY VALVE
CAUSING E168
SPARK GENERATOR
FAN RUNS DHWNO SUPPLY VOLTAGEFANE168
SENSOR - BOILER - SPARE
INSUFFICIENT
WATER SUPPLY
COOL HW
SENSOR - NTC (DHW)
DHW COOL RADS COOL
SENSOR - BOILER - SPARE
INSUFFICIENT PREVENTING RECTIFICATION
GAS INLET PRESSURE
BLANK FOR CASE REMOVAL
Z DIRECTION CHOICE OR CONTINUE
INSUFFICIENT CAUSING BAFFLING
GAS INLET PRESSURE
BLOCKED CAUSING BAFFLING
BODY - CONDENSATE TRAP
DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO CH CAUSING OVERHEAT
HARNESS - WIRING - HIGH VOLTAGE
OVERHEAT
TAP - ISOLATION - RETURN (FILTER)
DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO CH CAUSING OVERHEAT 2
HARNESS - WIRING - HIGH VOLTAGE
OVERHEAT DHW DIFF OK
TAP - ISOLATION - RETURN (FILTER)
BLOCKAGE CASUING POOR DHW
3 WAY VALVE ASSEMBLY
RESTRICTED LOWERING OUTPUT
BURNER
FLUEWAYS RESTRICTED LOWERING OUTPUT
HEAT EXCHANGER ASSEMBLY
FAN RUNS DHWNO SUPPLY VOLTAGEFANOH
THERMOSTAT - LIMIT
NO RESET OVERHEAT
SWITCH - SELECTOR - 4 POSITION
BLANK FOR INFORMATION INTELLIGENT PREHEAT
Z DIRECTION CHOICE OR CONTINUE
RESTRITED BLOCKED OR SPLIT PREVENTING IGNITON
PIPE - PRESSURE SWITCH
SPARK GENERATOR HARNESS SECTION FAULTY PREVENTING SPARKING
HARNESS - WIRING - HIGH VOLTAGE
RESTRICTED/BLOCKED OR SPLIT CAUSING BAFFLING
PIPE - PRESSURE SWITCH
RESTRICTED REDUCING OUTPUT
INJECTOR
EXTERNAL MIXING LOWERING DHW TEMPERATURE
EXTERNAL MIXING
GAS VALVE DAMAGED PCB
PCB AND GAS VALVE
FAULTY SOLENOID PREVENTING OPENING
GAS VALVE
BLOCKED PREVENTING BURNER ESTABLISHING
BODY - CONDENSATE TRAP
DETECTION LEAD SECTION FAULTY PREVENTING RECTIFICATION
HARNESS - WIRING
E125 FAULT CODE
TAP - ISOLATION - RETURN (FILTER)
RESTRICTED/BLOCKED CAUSING E125
HEAT EXCHANGER - DHW
FAN RUNS DHWNO SUPPLY VOLTAGEFANE168
THERMOSTAT - LIMIT
NO FANNO SUPPLY VOLTAGEFANE168
SENSOR - NTC (DHW)
LOW CAUSING E168
SYSTEM PRESSURE
BLOCKED/FAULTY CAUSING E168
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
SPARK ELECTRODES CAUSING E168
UNIT - IGNITION AND IONISATION - SPARE
DHW FLOW SENSOR SECTION FAULTY PREVENTING DEMAND
HARNESS - WIRING
NO MOVEMENT
FLOW REGULATOR
FAN RUNS DHWNO SUPPLY VOLTAGEFAN
SENSOR - BOILER - SPARE
NO FANNO SUPPLY VOLTAGEFAN
SENSOR - NTC (DHW)
LOW PREVENTING FAN RUNNING
SYSTEM PRESSURE
BLOCKED/FAULTY PREVENTING DEMAND
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
FAN RUNS DHWNO SUPPLY VOLTAGEFAN
THERMOSTAT - LIMIT
FAN AC SECTION FAULTY PREVENTING FAN RUNNING
HARNESS - WIRING - HIGH VOLTAGE
DC SECTION TO FAN FAULTY PREVENTING FAN RUNNING
HARNESS - WIRING
DHW HOT THEN COLD
PUMP
BLOCKAGE CAUSING DHW TO RUN HOT THEN COLD
3 WAY VALVE ASSEMBLY
OPERATION DHW DHW RUNS HOT THEN COLD
SENSOR - NTC (DHW)
MISSING OR OPEN CIRCUIT
CABLE - INTEGRAL TIMER
OPERATION DHW DHW RUNS HOT THEN COLD
SENSOR - BOILER - SPARE
RESTRICTED CAUSING WRONG MIX/BAFFLING
PLATE - ORIFICE
RESTRICTED CAUSING NO DROP
PLATE - ORIFICE
RESTRICTED CAUSING WRONG MIX/NO IGNITION
PLATE - ORIFICE
RESTRICTED CASUING LOW OUTPUT
PLATE - ORIFICE
AIR IN HEAT EXCHANGER CAUSING POOR DHW TEMPERATURE RISE
SYSTEM PRESSURE / AIR
AIR IN HEAT EXCHANGER CAUSING DHW TO RUN HOT AND COLD
SYSTEM PRESSURE / AIR
AIR IN BOILER OR SYSTEM CAUSING POOR CH OPERATION
SYSTEM PRESSURE / AIR
BLOCKED PREVENTING IGNITION
BODY - CONDENSATE TRAP
DHW ONE FAULTY PREHEAT ON
SPINDLE / KNOB ALIGNMENT
DHW ONE FAULTY DHW TOO HOT
SPINDLE / KNOB ALIGNMENT
CH ONE FAULTY LOW CH TEMPERATURE
SPINDLE / KNOB ALIGNMENT
DHW ONE FAULTY DHW TOO COOL
SPINDLE / KNOB ALIGNMENT
SHORTED CAUSING BLANK DISPLAY
SENSOR - HALL EFFECT
SHORTED CASUING BLANK DISPLAY
HARNESS - WIRING
SHORTED BLOWING FUSE
SPARK GENERATOR
NO CH SWITCH
SWITCH - SELECTOR - 4 POSITION
SECTION FROM TERMINAL STRIP TO SELECTOR SWITCH
HARNESS - WIRING - 5 + 1 TERMINAL
SPINDLE SEIZED
3 WAY VALVE ASSEMBLY
BLANK FOR LITE DIAGNOSTIC
Z DIRECTION CHOICE OR CONTINUE
BLANK FOR QADAI
Z DIRECTION CHOICE OR CONTINUE
QADAI
SENSOR - BOILER - SPARE
QADAI
GAS VALVE
RESTRICTED/BLOCKED FORCING HEAT PAST DIVERTER TO RADIATORS
HEAT EXCHANGER - DHW
QADAI
PUMP
QADAI AC
FAN
QADAI
SENSOR - NTC (DHW)
QADAI
MOTOR - 3 WAY VALVE
QADAI
SPARK GENERATOR
FAN RUNSDHW OPERATION DHW TOO HOT
SENSOR - NTC (DHW)
FLUEWAYS RESTRICTED CAUSING BAFFLING
HEAT EXCHANGER ASSEMBLY
NO PUMP VOLTAGE
PCB
NO OR LOW CHARGE
EXPANSION VESSEL
FULLY OR PARTIALLY CLOSED
FLOW AND RETURN VALVES
RADS COOL
PUMP
BLANK FOR TYPE OF DIAGNOSTIC PROCEDURE
Z DIRECTION CHOICE OR CONTINUE
BYPASS PASSING WHEN SHOULDNT
3 WAY VALVE ASSEMBLY
BLOCKED
TAP - ISOLATION - RETURN (FILTER)
F5 FAULT CODE
PUMP
OVERHEAT
SENSOR - NTC (DHW)
OVERHEAT
SENSOR - BOILER - SPARE
INSUFFICIENT CAUSING LOW OUTPUT
GAS INLET PRESSURE
DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO CH
HARNESS - WIRING - HIGH VOLTAGE
DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO DHW
HARNESS - WIRING - HIGH VOLTAGE
FAN RUNS DHWNO SUPPLY VOLTAGEFANE20
SENSOR - BOILER - SPARE
NO FANNO SUPPLY VOLTAGEFANE50
SENSOR - NTC (DHW)
LOW CAUSING E119
SYSTEM PRESSURE
BLOCKED/FAULTY CAUSING E119
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
E125
PUMP
E125
SENSOR - BOILER - SPARE
E125
SENSOR - NTC (DHW)
NO RESET
SWITCH - SELECTOR - 4 POSITION
FAN AC SECTION FAULTY PREVENTING FAN RUNNING CAUSING E160
HARNESS - WIRING - HIGH VOLTAGE
DC SECTION TO FAN FAULTY CAUSING E160
HARNESS - WIRING
BLANK FOR FAULT CODEES
Z DIRECTION CHOICE OR CONTINUE
SOLENOID BLOWING FUSE
GAS VALVE
SHORTED BLOWING FUSE
MOTOR - 3 WAY VALVE
POOR FLOW RATE
TAP - ISOLATION - DHW INLET
WATER PRESSURE SWITCH SECTION FAULTY CAUSING E119
HARNESS - WIRING
STUCK IN E164
PCB
WATER PRESSURE SWITCH SECTION FAULTY CASUING E164
HARNESS - WIRING
F5 FAULTE125E164
PUMP
PUMP SECTION FAULTY CASUING E164
HARNESS - WIRING - HIGH VOLTAGE
CORRECTLY ACTIVATED/NORMAL OPERATION
FROST PROTECTION
GIVING DEMAND WHEN SHOULD NOT
INTEGRAL TIMER / WIRELESS CONTROLS
BLANK FOR FUSE FURTHER INVESTIGATION F1
Z DIRECTION CHOICE OR CONTINUE
BLANK FOR FUSE FURTHER INVESTIGATION F2
Z DIRECTION CHOICE OR CONTINUE
BLANK FOR FUSE FURTHER INVESTIGATION F3
Z DIRECTION CHOICE OR CONTINUE
PRIMARY SENSOR SECTION FAULTY CAUSING ERRATIC DISPLAY
HARNESS - WIRING
PUMP SECTION FAULTY CAUSING E168
HARNESS - WIRING - HIGH VOLTAGE
GAS VALVE SECTION FAULTY CAUSING E168
HARNESS - WIRING - HIGH VOLTAGE
DIVERTER VALVE SECTION FAULTY CAUSING E168
HARNESS - WIRING - HIGH VOLTAGE
SPARK GENERATOR SECTION FAULTY CAUSING E168
HARNESS - WIRING - HIGH VOLTAGE
FAN AC SECTION FAULTY CAUSING E168
HARNESS - WIRING - HIGH VOLTAGE
DC SECTION TO FAN FAULTY CASUING E168
HARNESS - WIRING
PRIMARY SENSOR SECTION FAULTY CAUSING E168
HARNESS - WIRING
NOT MOVING TO CH CAUSING OVERHEAT
MOTOR - 3 WAY VALVE
RESTRICTED/BLOCKED CAUSING OVERHEAT
HEAT EXCHANGER - DHW
NOT MOVING TO CH CAUSING OVERHEAT 2
MOTOR - 3 WAY VALVE
RESTRICTED/BLOCKED CAUSING LOW DHW TEMPERATURE
HEAT EXCHANGER - DHW
WATERWAYS RESTRICTED CAUSING POOR DHW
HEAT EXCHANGER ASSEMBLY
OVERHEAT STAT SECTION FAULTY CAUSING OVERHEAT
HARNESS - WIRING
OPEN CIRCUIT OR POOR CONDITION PREVENTING SPARKING
SPARK PLUG AND HT LEAD
OPEN CIRCUIT OR POOR CONDITION PREVENTING IGNITON
SPARK PLUG AND HT LEAD
FLUEWAYS RESTRICTED PREVENTING IGNITON
HEAT EXCHANGER ASSEMBLY
INSUFFICIENT PREVENTING IGNITON
GAS INLET PRESSURE
GAS VALVE HARNESS DAMAGED PCB
PCB AND GAS VALVE HARNESS
GAS VALVE SECTION FAULTY PREVENTING INLET DROP
HARNESS - WIRING - HIGH VOLTAGE
FLUEWAYS RESTRICTED PREVETING INLET PRESSURE DROP
HEAT EXCHANGER ASSEMBLY
RESTRICTED OR BLOCKED ALLOWING DROP BUT PREVENTING IGNITION
PIPE - INDUCTION RESONANCE
RESTRICTED OR BLOCKED NO IGNITION
PLENUM - AIR INTAKE
RESTRICTED OR BLOCKED CAUSING NO INLET DROP
PIPE - INDUCTION RESONANCE
RESTRICTED OR BLOCKED NO IGNITION 2
PLENUM - AIR INTAKE
RESTRICTED OR BLOCKED CAUSING BAFFLING
PLENUM - AIR INTAKE
RESTRICTED OR BLOCKED CAUSING BAFFLING
PIPE - INDUCTION RESONANCE
RESTRICTED LOWERING OUTPUT
PIPE - INDUCTION RESONANCE
RESTRICTED LOWERING OUTPUT
PLENUM - AIR INTAKE
DETECTION ELECTRODE PREVENTING RECTIFICATION
UNIT - IGNITION AND IONISATION - SPARE
WATERWAYS RESTRICTED CAUSING E125
HEAT EXCHANGER ASSEMBLY
ALL OKAY
BOILER LOCKOUT
OVERHEAT STAT SECTION FAULTY CAUSING E168
HARNESS - WIRING
DHW SENSOR SECTION FAULTY CASUING E168
HARNESS - WIRING
WATER PRESSURE SWITCH SECTION FAULTY CAUSING E168
HARNESS - WIRING
NOT SENSING MAGNET FROM FLOW SWITCH ASSEMBLY
SENSOR - HALL EFFECT
PRIMARY SENSOR SECTION FAULTY PREVENTING FAN RUNNING
HARNESS - WIRING
DHW SENSOR SECTION FAULTY PREVENTING DEMAND
HARNESS - WIRING
WATER PRESSURE SWITCH SECTION FAULTY PREVENTING FAN RUNNING
HARNESS - WIRING
OVERHEAT STAT SECTION FAULTY PREVENTING FAN RUNNING
HARNESS - WIRING
RESTRICTED/BLOCKED CAUSING DHW TO RUN HOT AND COLD
HEAT EXCHANGER - DHW
WATERWAYS RESTRICTED CAUSING DHW TO RUN HOT AND COLD
HEAT EXCHANGER ASSEMBLY
NOT GIVING DEMAND WHEN SHOULD
INTEGRAL TIMER / WIRELESS CONTROLS
WRONG MIX CASUING BAFFLING
GAS VALVE
SOLENOID OK BUT NOT OPENING
GAS VALVE
SPARK GAP INCORRECT PREVENTING IGNITION
UNIT - IGNITION AND IONISATION - SPARE
SPARK GAP FROM BURNER INCORRECT PREVENTING IGNITION
UNIT - IGNITION AND IONISATION - SPARE
SPARK GAP INCORRECT OR OPEN CIRCUIT PREVENTING SPARKING
UNIT - IGNITION AND IONISATION - SPARE
CAUSING E168
PCB
NOT MAKING SPARKS
SPARK GENERATOR
NO FANB4 OP SEQ
SWITCH - SELECTOR - 4 POSITION
NO DISPLAY
PCB
PCB FUSE BLOWING
FUSE GONE PCB
SPARK GENERATOR SECTION SHORTED
HARNESS - WIRING - HIGH VOLTAGE
SELECTOR SWITCH TO PCB SECTION FAULTY
HARNESS - WIRING - 5 + 1 TERMINAL
NORMAL OPERATION
CALIBRATION FUNCTION
SENSOR TEMP FLOW
RESULT AS EXPECTED
PASSING TO RADIATORS
3 WAY VALVE ASSEMBLY
GAS VALVE
RESULT AS EXPECTED
PCB POWER TO GAS VALVE
RESULT AS EXPECTED
PUMP
RESULT AS EXPECTED
PCB POWER TO PUMP
RESULT AS EXPECTED
FAN AC
RESULT AS EXPECTED
PCB POWER TO FAN AC
RESULT AS EXPECTED
DHW SENSOR
RESULT AS EXPECTED
DIVERTER VALVE HEAD
RESULT AS EXPECTED
SPARK GENERATOR
RESULT AS EXPECTED
VOLTAGE NOT RUNNING
PUMP
PUMP SECTION FAULTY PREVENTING PUMP RUNNING
HARNESS - WIRING - HIGH VOLTAGE
EXPANSION VESSEL CONNECTION
PIPE ASSEMBLY - RETURN/PUMP (EXPANSION VESSEL PIPE)
F5 FAULT
PUMP
OVERHEAT
TEMPERATURE OVERHEAT
CUTTING OFF
THERMOSTAT - LIMIT
NOT MOVING TO CH
MOTOR - 3 WAY VALVE
NOT MOVING TO DHW POSITION
MOTOR - 3 WAY VALVE
PUMP SECTION FAULTY PREVENTING PUMP RUNNING CUSING OVERHEAT
HARNESS - WIRING - HIGH VOLTAGE
PRIMARY SENSOR SECTION FAULTY CAUSING E20
HARNESS - WIRING
STUCK IN E20
PCB
DHW SESNOR SECTION FAULTY CAUSING FAULT CODE
HARNESS - WIRING
STUCK IN E50
PCB
STUCK IN E119
PCB
F5 FAULTE125
PUMP
PUMP SECTION FAULTY CASUING E125
HARNESS - WIRING - HIGH VOLTAGE
STUCK IN E125
PCB
DIVERTER VALVE SECTION FAULTY BLOWING FUSE
HARNESS - WIRING - HIGH VOLTAGE
PUMP SECTION FAULTY BLOWING FUSE
HARNESS - WIRING - HIGH VOLTAGE
DC SECTION TO FAN CAUSING FUSE TO BLOW
HARNESS - WIRING
GAS VALVE SECTION FAULTY BLOWING FUSE
HARNESS - WIRING - HIGH VOLTAGE
FAN AC SECTION FAULTY BLOWING FUSE
HARNESS - WIRING - HIGH VOLTAGE
RESTRICTED/BLOCKED DHW SIDE CAUSING POOR FLOW RATE
HEAT EXCHANGER - DHW
FAN RUNS CONTINUALLY
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
DHW OR CH DEMAND LED ILLUMINATED
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
DISPLAY DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM POWER UP
DISPLAY ILLUMINATES BUT TEMPERATURE DISPLAYED ERRATIC
CHARACTERISTIC TEST FROM POWER UP
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT BAFFLES OUT OR IS NOISY
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
ELECTRODE UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS
IGNITION LEAD UNSATISFACTORY
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER
ELECTRODE UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS
IGNITION LEADS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS
HEAT EXCHANGER FLUEWAYS RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
IGNITION ELECTRODES UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
GAS INLET PRESSURE UNSATISFACTORY
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
GAS INLET PRESSURE OK BUT NO DROP SEEN
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
HEAT EXCHANGER FLUEWAYS RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
AIR INTAKE PIPE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
FAN AIR INTAKE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
AIR INTAKE PIPE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
FAN AIR INTAKE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
AIR INTAKE PIPE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
FAN AIR INTAKE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
AIR INTAKE PIPE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
FAN AIR INTAKE RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO COOL AND RADIATORS REMAIN COOL WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO COOL AND RADIATORS BEGIN TO HEAT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
NO VOLTAGE PRESENT ON TEST 1
CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION
VOLTAGE DOES NOT DROP TO 0 (ZERO) ON TEST 2
CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION
DHW RUNS HOT AND COLD
CHARACTERISTIC TEST FROM OPERATION DHW
VOLTAGE MISSING
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER
NO INTEGRAL TIMER FITTED
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER
DHW LED FLASHES
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
BOILER REACHES TEMPERATURE BUT RADIATORS REMAIN COLD
CHARACTERISTIC TEST FROM OPERATION CH
BOILER AND SYSTEM TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMP GOES ABOVE 90 DEGREES AND DOESNT CUT OFF
CHARACTERISTIC TEST FROM CH TEST OVERHEAT
BOILER LOCKS OUT ON OVERHEAT BEFORE REACHING 85 DEGREES
CHARACTERISTIC TEST FROM CH TEST OVERHEAT
10/06/2022 14:18:41 2205_1_50_1 20/10/2022 11:30:00
23/08/2022 14:36:16
RESISTANCE WATER PRESSURE SWITCH
REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
VOLTAGE FROM SWITCH LIVE
{SELHWCHON}
NO DEMANDS FOR CH
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FUSE F2 ( APPLIANCE)
REMOVE CONTROL BOX COVER
REMOVE THE FUSE AND HOLDER FROM THE LIVE (BROWN)
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE IGNITER
REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
RESISTANCE FAN DC
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
APPLI
DIVERTER VALVE BLOCKAGE
ISOLATE AND DRAIN DO
RESISTANCE SENSOR OVERHEAT STAT
REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE SELECTOR SWITCH (RESET)
{SELHWCHON}
REMOV
INSPECTION IGNITION ELECTRODES & LEADS
REMOVED ELECTRODE ASSEMBLY
DISCONNECT IGNITION LEADS FROM SPARK GENERATOR, NOTE CONNECTIONS
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE DETECTION LEAD
DISCONNECT INLINE CO
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE SENSOR OVERHEAT STAT
REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
DHW FLOW SWITCH OPERATION
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE SENSOR OVERHEAT STAT
REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
APPLI
DIVERTER VALVE BLOCKAGE
ISOLATE AND DRAIN DO
VOLTAGE FROM SELECTOR SWITCH
{SELHWCHON}
CH THERMOSTAT TO MAX
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE DIVERTER VALVE PCB
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE SELECTOR SWITCH
SELECTOR SWITCH IN HOT WATER
VOLTAGE SELECTOR SWITCH INPUT
SELECTOR SWITCH IN HOT WATER
RESISTANCE SPARK GENERATOR
REMOVE THE CONNECTOR FROM THE SPARK GENERATOR
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
GAS VALVE VOLTAGE (PCB)
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE IGNITER
REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
APPLI
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE WATER PRESSURE SWITCH
REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SELECTOR SWITCH (RESET)
{SELHWCHON}
REMOV
IS FAN RUNNING
{SELHWCHON}
RESISTANCE FAN HARNESS AC
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
RESISTANCE FAN DC
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
OBSERVATION ISOLATE DHW DOES DHW DEMAND STOP
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
OBSERVATION REMOVE HALL SENSOR DOES DHW DEMAND STOP
REMOVE DHW HALL SENSOR FROM FLOW VALVE
OBSERVATION DISCONNECT HALL SENSOR DOES DHW DEMAND STOP
REMOVE DHW HALL SENSOR FROM FLOW VALVE
REMOVE CONNECTOR FROM THE HALL SENSOR AND MAKE SAFE
RESISTANCE DHW FLOW SWITCH HARNESS
REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
VOLTAGE AC FROM INTEGRAL TIMER / WIRELESS RECEIVER
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
ENSURE NO CH DEMAND
VOLTAGE MAINS POWER INPUT TO APPLIANCE
REMOVE CONTROL BOX COVER
VOLTAGE AT PCB MAINS
REMOVE CONTROL BOX COVER
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE DIVERTER VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE IGNITER AND HARNESS
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FAN AND HARNESS AC
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FAN AND HARNESS DC
DISCONNECT CONNECTOR X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
WATER SUPPLY TO PREMISES
TURN ON A COLD WATER TAP
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
GAS INLET PRESSURE
{SELHWCHON}
SET D
GAS INLET PRESSURE
{SELHWCHON}
SET D
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
APPLI
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE C
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
OBSERVATION SPARKING OCCURS
REMOVE THE REARMOST
RESISTANCE SPARK GENERATOR HARNESS
REMOVE CONNECTOR FROM SPARK GENERATOR
REMOVE CONNECTOR X2 FROM THE PCB
INSPECTION INJECTOR
REMOVE THE INJECTOR
INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
REMOVE THE AIR INTAKE PIPE
INSPECTION INJECTOR
REMOVE THE INJECTOR
PRESSURE GAS INLET AND DROP
{SELHWCHON}
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
REMOVE THE AIR INTAKE PIPE
INSPECTION INJECTOR
REMOVE THE INJECTOR
INSPECTION IGNITION ELECTRODES & LEADS
REMOVED ELECTRODE ASSEMBLY
DISCONNECT IGNITION LEADS FROM SPARK GENERATOR, NOTE CONNECTIONS
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS
REMOVE BURNER DOOR ASSEMBLY
GAS VALVE VOLTAGE (PCB)
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
REMOVE THE AIR INTAKE PIPE
INSPECTION INJECTOR
REMOVE THE INJECTOR
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE
REMOVE THE AIR INTAKE PIPE
VOLTAGE RECTIFICATION ON PCB
{SELHWCHON}
REMOVE THE FLAME SENSE LEAD FROM TERMINAL X501
FLAME SENSE VOLTAGE AT PCB
{SELHWCHON}
CH TEST LOCKOUT
{SELHWCHON}
APPLI
HW TEST LOCKOUT
SELECTOR SWITCH TO H
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
INSPECTION ELECTRODES
REMOVE THE ELECTRODE ASSEMBLY FROM THE BOILER
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE WATER PRESSURE SWITCH
REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH
GAS INLET PRESSURE
{SELHWCHON}
SET D
INSPECTION DIVERTER VALVE DHW POSITION
SELECTOR SWITCH IN HOT WATER
REMOVE DIVERTER VALVE MOTOR
RESISTANCE DHW FLOW SWITCH HARNESS
REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH
INSPECTION FLOW SWITCH ASSEMBLY
ISOLATE MAINS WATER
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH
REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH
RESISTANCE FAN HARNESS AC
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE C
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
VOLTAGE FROM EXTERNAL CONTROLS
{SELHWCHON}
CH THERMOSTAT TO MAX
VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER
{SELHWCHON}
VOLTAGE TO INTEGRAL TIMER / WIRELESS RECEIVER
{SELHWCHON}
VOLTAGE LINKED CONNECTOR
{SELHWCHON}
INSPECTION ORIFICE PLATE
SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD
INSPECTION ORIFICE PLATE
SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD
INSPECTION ORIFICE PLATE
SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD
INSPECTION ORIFICE PLATE
SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD
OPERATION DHW CONTROL KNOB/SPINDLE
GAIN ACCESS TO PCB
OPERATION DHW CONTROL KNOB/SPINDLE
GAIN ACCESS TO PCB
OPERATION DHW CONTROL KNOB/SPINDLE
GAIN ACCESS TO PCB
INSPECTION DIVERTER VALVE SPINDLE
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
OPERATION CH CONTROL KNOB/SPINDLE
GAIN ACCESS TO PCB
VOLTAGE AC SPARK GENERATOR
{SELHWCHON}
GAIN
REMOVE DHW FLOW SWITCH DOES DISPLAY NOW WORK
REMOVE DHW HALL SENS
REMOVE CONNECTOR X400 DOES DISPLAY NOW WORK
REMOVE CONNECTOR X400 FROM PCB
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE HARNESS EXTERNAL CONTROLS TO PCB
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION HEAT EXCHANGER DHW
DRAIN PRIMARY CIRCUIT OF BOILER DOWN
TURN OFF HW ISOLATION VALVE
EXPANSION VESSEL PRESSURE
BOILER DISCHARGED
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
BYPASS PIPE TEMPERATURE
{SELHWCHON}
USE T
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE C
CH TEST OVERHEAT
{SELHWCHON}
APPLI
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE DC FROM FAN
{SELHWCHON}
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE FAN AND HARNESS DC
DISCONNECT CONNECTOR X401 FROM THE PCB
RESISTANCE FAN AND HARNESS AC
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE DIVERTER VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY
INSPECTION FLOW SWITCH ASSEMBLY
ISOLATE MAINS WATER
System Information
- Total Tests: 620
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control