Next: &nff, !f1942
ATTACH PRESSURE GAUG
Next: &nff, f1944
PLATE - BEARING
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
SET - CABLES (STEPPER MOTOR)
Next: End
SET - CABLES (STEPPER MOTOR)
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
SYSTEM PRESSURE
Next: End
BLOCK - BASIC - HEAT EXCHANGER
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
BLOCK - BASIC - HEAT EXCHANGER
Next: End
LEAD - IGNITION
Next: End
PLATE - BEARING
Next: End
HARNESS - CABLE 24V
Next: End
FUSING ELEMENT T2.5A
Next: End
HARNESS - CABLE 24V
Next: End
DIVERTER VALVE ASSEMBLY
Next: End
PLATE - BEARING
Next: End
LIMITER - TEMPERATURE (OVERHEAT THERMOSTAT)
Next: End
LIMITER - TEMPERATURE (SENSOR - FLUE)
Next: End
PLATE - BEARING
Next: End
LIMITER - TEMPERATURE (OVERHEAT THERMOSTAT)
Next: End
LIMITER - TEMPERATURE (SENSOR - FLUE)
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
ELECTRODE - SET OF 3
Next: End
HARNESS - CABLE 24V
Next: End
WATER COMPONENTS
Next: End
PLATE - BEARING
Next: End
PIPE (IMPULSE TUBE GAS VALVE)
Next: End
PIPE (IMPULSE TUBE GAS VALVE)
Next: End
PIPE (IMPULSE TUBE GAS VALVE)
Next: End
ELECTRODE - SET OF 3
Next: End
PCB FACTORY RESET
Next: End
HARNESS - CABLE 24V
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
SENSOR - TEMPERATURE
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
SENSOR - TEMPERATURE
Next: End
FLOW SENSOR ASSEMBLY
Next: End
MOTOR - DIVERTER VALVE
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
SENSOR - TEMPERATURE
Next: End
HARNESS - CABLE 24V
Next: End
ELECTRICAL SAFETY CHECKS
Next: End
PLATE - BEARING
Next: End
ELECTRICAL SAFETY CHECKS
Next: End
FUSE (FUSED SPUR)
Next: End
ELECTRODE - SET OF 3
Next: End
LIMITER - TEMPERATURE (OVERHEAT THERMOSTAT)
Next: End
LIMITER - TEMPERATURE (SENSOR - FLUE)
Next: End
SYSTEM PRESSURE
Next: End
SYSTEM PRESSURE
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
SENSOR - TEMPERATURE
Next: End
HEAT EXCHANGER - PLATE
Next: End
SYSTEM PRESSURE
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - TEMPERATURE
Next: End
EXPANSION VESSEL
Next: End
SYSTEM PRESSURE
Next: End
LIMITER - TEMPERATURE (OVERHEAT THERMOSTAT)
Next: End
LIMITER - TEMPERATURE (SENSOR - FLUE)
Next: End
SYSTEM PRESSURE
Next: End
SENSOR - TEMPERATURE
Next: End
LIMITER - TEMPERATURE (OVERHEAT THERMOSTAT)
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
SENSOR - TEMPERATURE
Next: End
HARNESS - CABLE 24V
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - TEMPERATURE - DHW
Next: End
RESET BUTTON STICKING
Next: End
LEAD - IGNITION
Next: End
HARNESS - CABLE 24V
Next: End
LIMITER - TEMPERATURE (SENSOR - FLUE)
Next: End
FILTER - INSERT - DHW
Next: End
HEAT EXCHANGER - PLATE
Next: End
DIVERTER VALVE ASSEMBLY
Next: End
MOTOR - DIVERTER VALVE
Next: End
MOTOR - DIVERTER VALVE
Next: End
MOTOR - DIVERTER VALVE
Next: End
MOTOR - DIVERTER VALVE
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
HEAT EXCHANGER - PLATE
Next: End
INTERNAL CLOCK/WIRELESS CONTROL
Next: End
HOLIDAY MODE LED
Next: End
HOLIDAY MODE LED
Next: End
BLOCK - BASIC - HEAT EXCHANGER
Next: End
HEAT EXCHANGER - PLATE
Next: End
PCB AND ELECTRODE ASSEMBLY
Next: End
FILTER - INSERT - DHW
Next: End
FLOW SENSOR ASSEMBLY
Next: End
ADAPTOR - FLOW SENSOR
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
ELECTRODE - SET OF 3
Next: End
HEAT EXCHANGER - PLATE
Next: End
PCB AND ELECTRODE ASSEMBLY
Next: End
ELECTRODE - SET OF 3
Next: End
PCB AND ELECTRODE ASSEMBLY
Next: End
CABLE FAN CONNECTOR ASSEMBLY
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
MOTOR - DIVERTER VALVE
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
RESULT AS EXPECTED
Next: End
GAS VALVE - NO PRESSURE DROP
Next: End
HARNESS - CABLE 24V
Next: End
BLOCK - BASIC - HEAT EXCHANGER
Next: End
PIPE (EXPANSION VESSEL)
Next: End
HARNESS - CABLE 24V
Next: End
HEAT EXCHANGER - PLATE
Next: End
BLOCK - BASIC - HEAT EXCHANGER
Next: End
FLOW SENSOR ASSEMBLY
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
HARNESS - CABLE 24V
Next: End
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p11
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p480
CHARACTERISTIC TEST FROM PERFORMANCE TEST MAX AND MIN
Next: p1441
CHARACTERISTIC TEST FROM PERFORMANCE TEST MAX AND MIN
Next: !p1088
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p646
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p113
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p115
CHARACTERISTIC TEST FROM PRESSURE FAN MAXIMUM OUTPUT
Next: p1499
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p13
CHARACTERISTIC TEST FROM PRESSURE FAN MAXIMUM OUTPUT
Next: !p1202
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: p1218
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: !p1220
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: p1243
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: !p1245
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p1281
CHARACTERISTIC TEST FROM PUMP OVERRUN
Next: !p1338
CHARACTERISTIC TEST FROM PUMP OVERRUN
Next: p1684
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p15
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p1481
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p1483
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p1485
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS (FAN DOES NOT RUN)
Next: !p1491
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE ASSEMBLY
Next: !p1594
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE ASSEMBLY
Next: !p1596
CHARACTERISTIC TEST FROM CH OPERATION
Next: p594
CHARACTERISTIC TEST FROM CH OPERATION
Next: p166
CHARACTERISTIC TEST FROM CH OPERATION
Next: p168
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE
Next: p1721
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE
Next: p1723
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p1733
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p1735
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: !p1751
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: p1851
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: !p1763
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: p1845
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE
Next: p1781
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB) - NEW STYLE
Next: p1783
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p1793
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p1795
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: !p1811
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: p1857
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: !p1823
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
Next: p1861
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1873
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1875
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1877
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1879
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1881
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1883
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1885
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1887
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1889
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1891
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1893
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: !p1895
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1897
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
Next: p1899
CHARACTERISTIC TEST FROM DHW BURNER IGNITION & ESTABLISH
Next: p20
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: p1907
CHARACTERISTIC TEST FROM VOLTAGE DIVERTER VALVE PCB DROP RETURN TO 15V
Next: !p1909
CHARACTERISTIC TEST FROM DHW BURNER IGNITION & ESTABLISH
Next: p22
CHARACTERISTIC TEST FROM DHW BURNER IGNITION & ESTABLISH
Next: p270
CHARACTERISTIC TEST FROM DHW BURNER IGNITION & ESTABLISH
Next: p327
CHARACTERISTIC TEST FROM MODE OF FAN OPERATION
Next: p387
CHARACTERISTIC TEST FROM MODE OF FAN OPERATION
Next: p1716
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
Next: p445
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
Next: !p444
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p582
CHARACTERISTIC TEST FROM DIFFERENTIAL FLOW RETURN CH OPERATION
Next: !p600
CHARACTERISTIC TEST FROM DIFFERENTIAL FLOW RETURN CH OPERATION
Next: !p602
CHARACTERISTIC TEST FROM CH OPERATION
Next: p634
CHARACTERISTIC TEST FROM CHECK FLOW COMPONENTS
Next: !p765
01/12/2022 09:46:51
Next: End
{ONOFFSWITCHON}
N
Next: !p1216, ?1217, ?1219
{ONOFFSWITCHON}
N
Next: !p1241, ?1242, ?1244
GAIN ACCESS TO THE P
Next: p1262, f1253
REMOVE THE DC PUMP CONNECTOR ST18 FROM THE PCB AND MAKE SAFE
Next: p1254, !f1255
REMOVE CONNECTOR FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p1269, !f1270
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p1278, !f1279
GAIN ACCESS TO PCB (USE ISOLATION MAT AS REQUIRED)
EXTERNAL CONTROLS CALLING FOR HEAT
Next: p1296, f1297
GAIN ACCESS TO PCB (USE ISOLATION MAT AS REQUIRED)
Next: !p1298, !f1299
{ONOFFSWITCHON}
CH BOILER THERMOSTAT SET TO MAX
Next: !p1302, !f1303
GAIN ACCESS TO PCB (USE ISOLATION MAT AS REQUIRED)
Next: !p1306, !f1307
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
Next: !p1322, !f1323
REMOVE CONTROL BOX COVER IF NECESSARY
Next: !p1412, f1413
DISCONNECT RED LEADS FROM THE OVERHEAT THERMOSTAT
Next: p1535, !f1536
REMOVE CONTROL BOX C
Next: !p1555, f1556
DISCONNECT RED LEADS FROM THE OVERHEAT THERMOSTAT
Next: p1557, !f1558
REMOVE THE LEADS FRO
Next: !p1602, !f1603
REMOVE THE LARGE 20 WAY CONNECTOR (ST9) FROM THE RIGHT HAND SIDE OF THE PCB.
Next: p1605, f1610
REMOVE THE BLUE LEAD
Next: !p1611, !f1612
{ONOFFSWITCHON}
Next: p1776, f1806
MOVE CONNECTOR ST5 T
Next: p1719, ?1720, ?1722
MOVE CONNECTOR ST5 U
Next: p1749, ?1750, ?1752
MOVE CONNECTOR ST5 T
Next: p1779, ?1780, ?1782
MOVE CONNECTOR ST5 U
Next: p1809, ?1810, ?1812
DISCONNECT FAN CONNECTOR AT FAN
Next: !p1839, f1840
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p185, !f186
REMOVE CONTROL BOX COVER IF NECESSARY, USE ISOLATION MAT AS REQUIRED
Next: p200, f201
REMOVE FUSE FROM FUSED SPUR
Next: !p202, f203
DISCONNECT RED LEADS FROM THE OVERHEAT THERMOSTAT
Next: p390, !f391
DRAIN THE DOMESTIC H
Next: p7, ?8, ?10, ?12, ?14
ENSURE BOILER IS COOL
Next: p708, f709
REMOVE CONTROL BOX C
Next: !p710, f711
DISCONNECT RED LEADS FROM THE OVERHEAT THERMOSTAT
Next: p712, !f713
GAIN ACCESS TO THE P
Next: p1430, f721
REMOVE THE DC PUMP CONNECTOR ST18 FROM THE PCB AND MAKE SAFE
Next: p722, !f775
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
Next: !p734, f735
DISCONNECT RED LEADS
Next: !p1039, !f762
REMOVE PUMP CONNECTOR FROM PCB
Next: p1509, f821
DISCONNECT THE PUMP HARNESS AT THE PUMP AND THE PCB
Next: !p822, !f823
REMOVE ST9 CONNECTOR
Next: !p874, f875
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p876, !f877
REMOVE ST9 CONNECTOR
Next: !p880, f881
REMOVE CONNECTOR FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p882, !f883
DISCONNECT THE INLIN
Next: !p905, !f906
REMOVE CONNECTOR FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p909, !f910
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p912, !f913
LOWER THE FACIA PANEL
Next: !p929, !f928
REMOVE PCB COVER AS NECESSARY
Next: p933, !f932
GAIN ACCESS TO PCB AS NECESSARY
Next: p980, !f979
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1060, !f1019
REMOVE FAN ASSEMBLY
Next: !p1324, !f1062
REMOVE THE DIVERTER
Next: !p118, f1215
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p116, !f117
NO DEMAND
PREHEAT SWITCHED OFF (ECO BUTTON ILLUMINATED)
REMOVE CONNECTOR ST17 FROM PCB
Next: p1221, !f1222
REMOVE THE CONNECTOR
Next: !p1223, !f1224
NO DEMAND
PREHEAT SWITCHED OFF (ECO BUTTON ILLUMINATED)
REMOVE CONNECTOR ST17 FROM PCB
Next: p1246, !f1247
REMOVE THE CONNECTOR
Next: !p1248, !f1249
DISCONNECT THE PUMP HARNESS AT THE PUMP AND THE PCB
Next: !p1256, !f1257
REMOVE ST9 CONNECTOR
Next: p1271, f1268
REMOVE ST9 CONNECTOR
Next: p1407, f1277
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
Next: p1286, !f1287
REMOVE CONNECTOR FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: p1288, !f1289
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p1290, !f1291
GAIN ACCESS TO PCB (USE ISOLATION MAT AS REQUIRED)
EXTERNAL CONTROLS CALLING FOR HEAT
Next: p1304, f1305
REMOVE AND DISCONNECT THE INTERNAL CLOCK OR WIRELESS RECEIVER ASSEMBLY FROM THE BOILER
Next: !p1300, f1301
{ONOFFSWITCHON}
CH BOILER THERMOSTAT SET TO MAX
Next: !p1308, !f1309
ENSURE PLATE HEAT EX
Next: p1316, !f1590
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
DHW THERMOSTAT TO MAX
Next: p1561, f1321
REMOVE THE IGNITION HARNESS FROM THE PCB
AND THE SPARK ELECTRODES
Next: p1345, !f1346
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
Next: p1383, f1348
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1351, !f1352
REMOVE FAN ASSEMBLY
Next: !p1353, !f1354
REMOVE AIR INTAKE MANIFOLD FROM THE FAN
Next: p1642, !f1390
REMOVE AIR INTAKE MANIFOLD FROM THE FAN
Next: p372, !f1405
REMOVE CONDENSE TRAP
Next: p1639, !f1409
REMOVE CONDENSE TRAP
Next: !p1433, !f1432
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
Next: p1435, !f1436
REMOVE AIR INTAKE MANIFOLD FROM THE FAN
Next: !p1442, !f1443
DRAIN THE DOMESTIC H
Next: !p1489, ?1480, ?1482, ?1484, ?1490
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1503, !f1504
REMOVE FAN ASSEMBLY
Next: !p1505, !f1506
DISCONNECT FAN CONNECTOR ST5 FROM THE PCB
Next: p1599, f1838
REMOVE CONTROL BOX C
Next: p1540, f1534
DISCONNECT THE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p1537, !f1538
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
Next: p1541, f1542
REMOVE AIR INTAKE MANIFOLD FROM THE FAN
Next: p1932, !f1550
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1545, !f1546
REMOVE FAN ASSEMBLY
Next: !p1547, !f1548
DISCONNECT THE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p1559, !f1560
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: p1313, !f1589
REMOVE THE BURNER ASSEMBLY FROM THE APPLIANCE
Next: !p1592, ?1593, ?1595
REMOVE ST9 CONNECTOR
Next: !p1600, f1601
REMOVE THE BLUE LEAD
Next: p1606, !f1607
REMOVE THE ELECTRODE ASSEMBLY
Next: !p1608, !f1609
GAIN ACCESS TO BOILER INTERNALS & PCB CONNECTIONS AS NECESSARY
Next: p1677, !f1623
REMOVE GAS VALVE IMPULSE TUBE
Next: p1625, !f1638
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
Next: p1626, f1627
REMOVE AIR INTAKE MANIFOLD FROM THE FAN
Next: p1634, !f1635
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1630, !f1631
REMOVE FAN ASSEMBLY
Next: !p1632, !f1633
REMOVE DC CONNECTOR FROM PUMP.
Next: !p1640, !f1641
REMOVE GAS VALVE IMPULSE TUBE
Next: p1591, !f1649
REMOVE GAS VALVE IMPULSE TUBE
Next: p365, !f1676
ATTACH U GAUGE TO INLET PRESSURE TEST POINT
ENSURE NO OTHER GAS APPLIANCES ARE IN OPERATION
Next: p1678, !f1679
REMOVE THE ELECTRODE ASSEMBLY
Next: !p1682, !f1683
Next: p1685, !f1686
REMOVE CONDENSE TRAP
Next: !p1687, !f1688
MOVE CONNECTOR ST5 T
Next: p1730, ?1732, ?1734
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1728, !f1729
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1726, !f1727
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1724, !f1725
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1742, !f1743
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1738, !f1739
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1736, !f1737
REMOVE AIR INTAKE HO
Next: !p1740, !f1741
REMOVE AIR INTAKE HO
Next: !p1744, !f1745
MOVE CONNECTOR ST5 U
Next: p1760, ?1762, ?1764
DISCONNECT ELECTRICA
Next: p1756, !f1757
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: p177, !f178
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1754, !f1755
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1758, !f1759
DISCONNECT ELECTRICA
Next: p1770, !f1771
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1766, !f1767
REMOVE AIR INTAKE HO
Next: !p1768, !f1769
REMOVE THE DIVERTER
Next: p1434, f1240
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1772, !f1773
REMOVE AIR INTAKE HO
Next: !p1774, !f1775
MOVE CONNECTOR ST5 T
Next: p1790, ?1792, ?1794
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1788, !f1789
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1786, !f1787
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1784, !f1785
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1802, !f1803
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1798, !f1799
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1796, !f1797
REMOVE AIR INTAKE HO
Next: !p1800, !f1801
REMOVE AIR INTAKE HO
Next: !p1804, !f1805
MOVE CONNECTOR ST5 U
Next: p1820, ?1822, ?1824
DISCONNECT ELECTRICA
Next: p1816, !f1817
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1814, !f1815
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: !p1818, !f1819
DISCONNECT ELECTRICA
Next: p1830, !f1831
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1826, !f1827
REMOVE AIR INTAKE HO
Next: !p1828, !f1829
DISCONNECT CONNECTOR ST5 FROM THE PCB
DISCONNECT CONNECTOR FROM THE FAN ASSEMBLY
Next: p1832, !f1833
REMOVE AIR INTAKE HO
Next: !p1834, !f1835
REMOVE AIR INTAKE HO
Next: !p1843, !f1844
REMOVE THE CONNECTOR
Next: p1765, !f1855
REMOVE THE CONNECTOR
Next: p1753, !f1856
REMOVE THE CONNECTOR
Next: p1813, !f1868
REMOVE THE CONNECTOR
Next: p1825, !f1867
DIAGNOSIS RELIES ON
Next: !p1930, !f1931
THE TABLE BELOW SHOW
Next: !p1928, !f1929
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p1926, !f1927
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: !p1924, !f1925
REMOVE THE GAS VALVE
Next: !p1922, !f1923
REMOVE ST9 CONNECTOR
Next: !p1920, !f1921
REMOVE PUMP CONNECTOR FROM PCB
Next: !p1918, !f1919
REMOVE THE DC PUMP CONNECTOR ST18 FROM THE PCB AND MAKE SAFE
Next: !p1916, !f1917
DISCONNECT FAN CONNECTOR AT FAN
Next: !p1914, !f1915
REMOVE ST17 CONNECTO
Next: !p1912, !f1913
{ONOFFSWITCHON}
N
Next: !p1904, ?1906, ?1908
REMOVE DC CONNECTOR FROM PUMP.
Next: !p1902, !f1903
TURN HOT WATER TAP ON WITH A FLOW RATE OF APPROXIMATELY 3 L/MIN
Next: !p1900, !f1901
NO DEMAND
PREHEAT SWITCHED OFF (ECO BUTTON ILLUMINATED)
REMOVE CONNECTOR ST17 FROM PCB
Next: !p1910, !f1911
REMOVE THE LEADS FRO
Next: !p1933, !f1934
REMOVE FLUEWAYS INSPECTION PLATE
Next: p1949, !f1950
REMOVE FAN ASSEMBLY
Next: !p1951, !f1952
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT ON GAS VALVE
Next: p1650, !f90
{ONOFFSWITCHON}
Next: p408, ?386, ?394
GAIN ACCESS TO PCB (USE ISOLATION MAT AS REQUIRED)
Next: p898, f1411
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT ON GAS VALVE
Next: p1624, !f331
GAIN ACCESS TO MAINS
Next: p366, f1604
ATTACH PRESSURE GAUGE TO FAN PRESSURE TEST POINT
Next: p1401, f1013
REMOVE THE ELECTRODE ASSEMBLY
Next: !p1373, !f377
REMOVE CONTROL BOX C
Next: !p388, f389
DISCONNECT THE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p392, !f393
REMOVE THE GAS VALVE
Next: p1532, f1554
REMOVE SPARK LEADS F
Next: p61, !f400
REMOVE ORANGE WIRES FROM DHW SENSOR
Next: p586, !f589
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: p587, !f590
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
DHW THERMOSTAT TO MAX
Next: !p591, !f593
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: p597, !f605
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
Next: !p598, ?599, ?601
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p610, !f611
ATTACH U GAUGE TO INLET PRESSURE TEST POINT
Next: p1344, ?441, ?443
BOILER DRAINED AND DISCHARGED
Next: !p635, !f636
DISCONNECT THE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p714, !f715
DISCONNECT THE PUMP HARNESS AT THE PUMP AND THE PCB
Next: !p779, !f768
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
DHW THERMOSTAT TO MAX
Next: p732, f733
ATTACH TEMPERATURE P
Next: p738, f739
REMOVE ORANGE WIRES FROM PRIMARY SENSOR
ENSURE PRIMARY HEAT EXCHANGER IS BELOW 60° C
Next: !p742, !f743
LOWER THE FACIA PANEL
Next: p900, !f899
TURN HOT WATER TAP ON WITH A FLOW RATE OF APPROXIMATELY 3 L/MIN
Next: p901, f902
REMOVE ST9 CONNECTOR
Next: p907, f908
REMOVE ST9 CONNECTOR
Next: p1746, f911
NO DEMANDS
Next: !p992, !f993
REMOVE THE IGNITION HARNESS FROM THE PCB
AND THE SPARK ELECTRODES
Next: p981, !f984
REMOVE THE BLUE LEAD
Next: !p1428, !f985