VOKERA COMPACT 29
GLOBALLY REPLACED
OBSERVATION BOILER SELF CHECK
CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE NO DEMANDS & BOILER IS COOL
OBSERVATION FAN RUNS
CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE BOILER IS COOL
PRESSURE GAS INLET (DHW DEMAND)
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
FUSE FURTHER INVESTIGATION
NOT USED
HOW TO CANCEL PURGE CYCLE
CH & DHW TEMPERATURE
FAULT CODE SOLID RED
BLANK
FAULT CODE RED BLINKING
BLANK
HOW TO CANCEL PUMP PURGE CYCLE - FAULT CODES
CH & DHW TEMPERATURE
PREHEAT ENABLED
NOT USED
COMBUSTION MODE
NOT USED
NEW QADAI OPTIONS
OUTSIDE MODEL
BOILER FIRES NO DEMAND
DOMESTIC PLUMBING
BOILER FIRES NO DEMAND
ACTUATOR - DHW
BOILER FIRES NO DEMAND
DETECTOR - WATER
BOILER FIRES NO DEMAND
SENSOR - NTC
USER CONTROLS
Z REDIRECT
DHW FLOW RATE
COCK STOP - WATER SUPPLY
DHW FLOW RATE
COLD WATER SUPPLY
FAN DOES NOT RUN 4
HARNESS - WIRING
FAN DOES NOT RUN
FAN
FAN DOES NOT RUN
DETECTOR - WATER
FAN DOES NOT RUN 2
DETECTOR - WATER
FAN DOES NOT RUN
SENSOR - NTC
FAN DOES NOT RUN
PRINTED CIRCUIT BOARD
PUMP DOES NOT RUN
PRINTED CIRCUIT BOARD
PUMP DOES NOT RUN
HARNESS - WIRING
BURNER DOES NOT IGNITE
CONDENSATE
BURNER DOES NOT IGNITE
GAS INLET PRESSURE
BURNER DOES NOT IGNITE
PIPE - SUCTION
BURNER DOES NOT IGNITE
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
PIPE - SUCTION
BURNER DOES NOT IGNITE 2
HARNESS - WIRING
BOILER DOES NOT EST
CONDENSATE
BOILER DOES NOT EST
COMPENSATION TUBE
BOILER DOES NOT EST
GAS INLET PRESSURE
BOILER DOES NOT EST 2
ELECTRODE - DETECTION
BOILER DOES NOT EST 2
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
FLUE
BURNER BAFFLES OR NOISY
CONDENSATE
BURNER BAFFLES OR NOISY
COMPENSATION TUBE
BURNER BAFFLES OR NOISY
GAS INLET PRESSURE
BURNER BAFFLES OR NOISY
PIPE - SUCTION
DHW TOO HOT
SENSOR - NTC
DHW COOL RADS COOL
PUMP
DHW COOL RADS COOL
SENSOR - NTC
DHW COOL RADS COOL
DETECTOR - WATER
DHW COOL RADS COOL
PLUMBING ISSUE
DHW COOL RADS COOL
BY-PASS VALVE - DHW
DHW COOL RADS COOL
VALVE - NON RETURN
DHW HOT THEN COOL
PUMP
DHW HOT THEN COOL
SENSOR - NTC
DHW HOT THEN COOL
DETECTOR - WATER
DHW HOT THEN COOL
VALVE - NON RETURN
CH OPERATION
EXPANSION VESSEL
CH OPERATION
COCK 3/4 IN - HEATING - WATER
CH OPERATION
DETECTOR - WATER
CH OPERATION 2
DETECTOR - WATER
CH OPERATION 2
PUMP
RESISTANCE SPARK GENERATOR
TRANSFORMER - IGNITION
FUSE FURTHER INVESTIGATION 2
GAS VALVE
FUSE FURTHER INVESTIGATION
ACTUATOR
FAULT CODE 2
Z REDIRECT
FAULT CODES
Z REDIRECT
FAULT CODE RED SOLID
THERMOSTAT - HIGH LIMIT
FAULT CODE RED SOLID 2
PRINTED CIRCUIT BOARD
FAULT CODE RED SOLID 2
HARNESS - WIRING
FAULT CODE RED SOLID
DETECTOR - WATER
FAULT CODE RED SOLID 2
DETECTOR - WATER
FAULT CODE RED SOLID
SENSOR - NTC
FAULT CODE SOLID RED
DETECTOR - WATER
FAULT CODE SOLID RED 2
DETECTOR - WATER
FAULT CODE SOLID RED 3
HARNESS - WIRING
FAULT CODE BLINKING RED GREEN 2
DETECTOR - WATER
FAULT CODE BLINKING RED GREEN
DETECTOR - WATER
FAULT CODE BLINKING RED GREEN
SENSOR - FLUE
FAULT CODE BLINKING RED GREEN
PRINTED CIRCUIT BOARD
FAULT CODE GREEN BLINKING
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND
MECHANICAL CLOCK
CH DOES NOT RESPOND 3
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND 3
MECHANICAL CLOCK
CH DOES NOT RESPOND 2
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND 2
MECHANICAL CLOCK
FAULT CODE SOLID RED 4
HARNESS - WIRING
PREHEAT
PRINTED CIRCUIT BOARD
COMBUSTION MODE
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
FLUE
DHW COOL RADS COOL
PIPE - SUCTION
DHW COOL RADS COOL 2
FLUE
DHW COOL RADS COOL 2
PIPE - SUCTION
DHW COOL RADS COOL 2
BY-PASS VALVE - DHW
BOILER DOES NOT EST
ELECTRODE - DETECTION
BURNER DOES NOT IGNITE
ELECTRODE - IGNITION
FAN DOES NOT RUN 2
HARNESS - WIRING
BURNER DOES NOT IGNITE
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
HARNESS - WIRING
FAULT CODE RED BLINKING
VALVE - NON RETURN
FAULT CODE RED BLINKING
HEAT EXCHANGER ASSEMBLY - WATERWAYS
FAULT CODE RED SOLID 3
PRINTED CIRCUIT BOARD
FAULT CODE BLINKING RED GREEN 4
HARNESS - WIRING
BOILER DOES NOT EST
PIPE - SUCTION
CASE REMOVAL
Z REDIRECT
DHW OPERATION 4
PRINTED CIRCUIT BOARD
DHW OPERATION 2
PRINTED CIRCUIT BOARD
DHW OPERATION 3
PRINTED CIRCUIT BOARD
FUSE FURTHER INVESTIGATION
SOLENOID
DHW RADS BEGIN TO HEAT 2
PRINTED CIRCUIT BOARD
DHW RADS BEGIN TO HEAT 2
HARNESS - WIRING
CH OPERATION 4
PRINTED CIRCUIT BOARD
CH OPERATION 2
HARNESS - WIRING
CH OPERATION 3
PUMP
CH OPERATION 2
BY-PASS VALVE - DHW
DHW RADS BEGIN TO HEAT
PRINTED CIRCUIT BOARD
CH OPERATION
HARNESS - WIRING
CH OPERATION 2
PRINTED CIRCUIT BOARD
CH OPERATION
PUMP
CH OPERATION
BY-PASS VALVE - DHW
DHW RADS BEGIN TO HEAT
HARNESS - WIRING
CH RADS HEAT
CARTRIDGE
CH RADS HEAT 2
CARTRIDGE
FAULT CODE RED SOLID
SENSOR - FLUE
FAULT CODE RED SOLID 6
PRINTED CIRCUIT BOARD
FAULT CODE RED SOLID 5
HARNESS - WIRING
FAULT CODE RED SOLID 5
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
GAS VALVE & PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
SOLENOID - GAS VALVE & PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
THERMOSTAT - HIGH LIMIT
NO VOLTAGE TO DIVERTER (QADAI)
PRINTED CIRCUIT BOARD
INCORRECT RESISTANCE (QADAI)
ACTUATOR
NO VOLTAGE TO SPARK GEN (QADAI)
PRINTED CIRCUIT BOARD
INCORRECT RESISTANCE (QADAI)
TRANSFORMER - IGNITION
FAULT CODE A03 (QADAI)
HARNESS - WIRING
NO POWER TO FAN (QADAI)
PRINTED CIRCUIT BOARD
NO POWER TO PUMP (QADAI)
PRINTED CIRCUIT BOARD
NO POWER TO GAS VALVE (QADAI)
PRINTED CIRCUIT BOARD
QADAI
SENSOR - FLUE
QADAI
SENSOR - NTC
OUT OF RANGE (QADAI) 2
DETECTOR - WATER
OUT OF RANGE (QADAI)
DETECTOR - WATER
DIAG LITE 2
Z REDIRECT
QADAI 1
Z REDIRECT
QADAI RESISTANCE SIEMENS
GAS VALVE
QADAI RESISTANCE SIT
GAS VALVE
LEDS DO NOT WORK
FUSE (FUSED SPUR)
LEDS DOT NOT WORK
MAINS INPUT FUSE
LEDS DO NOT WORK
FUSE F1
ONLY 1 ATTEMPT TO IGNITE
SENSOR - PRESSURE
ONLY 1 ATTEMPT TO IGNITE
THERMOSTAT - HIGH LIMIT
GAS INLET DHW DEMAMD
GAS INLET PRESSURE
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
BOILER FIRES NO DEMAND
PRINTED CIRCUIT BOARD
BOILER FIRES NO DEMAND
HARNESS - WIRING
BOILER FIRES NO DEMAND
FROST PROTECTION MODE
BOILER FIRES NO DEMAND 2
PRINTED CIRCUIT BOARD
DHW FLOW RATE
HEAT EXCHANGER - PLATE
DHW FLOW RATE
GOVERNOR - FLOW
DHW FLOW RATE
ACTUATOR - DHW
DHW FLOW RATE
INLET FILTER - DHW
FAN DOES NOT RUN 3
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 3
HARNESS - WIRING
FAN DOES NOT RUN
SENSOR - PRESSURE
FAN DOES NOT RUN 4
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN
ACTUATOR - DHW
FAN DOES NOT RUN
GOVERNOR - FLOW
FAN DOES NOT RUN 2
ACTUATOR - DHW
FAN DOES NOT RUN
INLET FILTER - DHW
FAN DOES NOT RUN
HARNESS - WIRING
PUMP DOES NOT RUN
PUMP
BURNER DOES NOT IGNITE 2
GAS VALVE
BURNER DOES NOT IGNITE 2
BURNER ASSEMBLY
BURNER DOES NOT IGNITE 2
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BOILER DOES NOT EST
HARNESS - WIRING
BOILER DOES NOT EST 2
HARNESS - WIRING
BURNER BAFFLES OR NOISY
GAS VALVE
BURNER BAFFLES OR NOISY
BURNER ASSEMBLY
BURNER BAFFLES OR NOISY
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW TOO HOT
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
HEAT EXCHANGER - PLATE
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
DHW HOT THEN COOL
PRINTED CIRCUIT BOARD
DHW HOT THEN COOL
HEAT EXCHANGER - PLATE
DHW HOT THEN COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
CH OPERATION
PIPE
CH OPERATION 3
PRINTED CIRCUIT BOARD
CH OPERATION
PRESSURE GAUGE
CH OPERATION
SYSTEM PRESSURE
CH OPERATION 2
PRESSURE GAUGE
CH OPERATION 2
SYSTEM PRESSURE
DHW HOT THEN COOL
PRESSURE GAUGE
DHW HOT THEN COOL
SYSTEM PRESSURE
DHW COOL RADS COOL
PRESSURE GAUGE
DHW COOL RADS COOL
SYSTEM PRESSURE
FAN DOES NOT RUN
PRESSURE GAUGE
FAN DOES NOT RUN
SYSTEM PRESSURE
FUSE FURTHER INVESTIGATION
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 2
PRINTED CIRCUIT BOARD - FUSE BLOWN
OBSERVATION GAS VALVE TYPE?
PRINTED CIRCUIT BOARD - FUSE BLOWN
FUSE FURTHER INVESTIGATION 3
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 2
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 4
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 5
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 6
HARNESS - WIRING
FAULT CODE
Z REDIRECT
FAULT CODE RED SOLID
PRINTED CIRCUIT BOARD
FAULT CODE RED SOLID
HARNESS - WIRING
FAULT CODE RED SOLID
PRESSURE GAUGE
FAULT CODE RED SOLID
SYSTEM PRESSURE
FAULT CODE RED SOLID
PUMP
FAULT CODE RED SOLID 2
THERMOSTAT - HIGH LIMIT
FAULT CODE RED SOLID 4
PRINTED CIRCUIT BOARD
FAULT CODE SOLID RED
HARNESS - WIRING
FAULT CODE SOLID RED 2
HARNESS - WIRING
FAULT CODE SOLID RED
PRINTED CIRCUIT BOARD
FAULT CODE SOLID RED
FAULT CODE RESET - RETEST BOILER OPERATION
FAULT CODE SOLID RED
Z REDIRECT
FAULT CODE BLINKING RED GREEN 2
HARNESS - WIRING
FAULT CODE BLINKING RED GREEN
HARNESS - WIRING
FAULT CODE BLINKING RED GREEN 3
HARNESS - WIRING
FAULT CODE BLINKING RED GREEN
FAULT CODE RESET - RETEST BOILER OPERATION
FAULT CODE GREEN BLINKING
HARNESS - WIRING
FAULT CODE GREEN BLINKING
SENSOR - PRESSURE
FAULT CODE GREEN BLINKING
PRESSURE GAUGE
FAULT CODE GREEN BLINKING
SYSTEM PRESSURE
FAULT CODE GREEN BLINKING
FAULT CODE RESET - RETEST BOILER OPERATION
PREHEAT
PREHEAT - TURNED OFF
COMBUSTION
COMBUSTION MODE - CANCELLED
DHW COOL RADS COOL 2
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
BURNER ASSEMBLY
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL 2
BURNER ASSEMBLY
DHW COOL RADS COOL 2
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL 3
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
BURNER ASSEMBLY
BOILER DOES NOT EST
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BOILER DOES NOT EST 3
ELECTRODE - DETECTION
BOILER DOES NOT EST
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
BURNER ASSEMBLY
BURNER DOES NOT IGNITE
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BURNER DOES NOT IGNITE 2
ELECTRODE - IGNITION
BURNER DOES NOT IGNITE
GAS VALVE
FAN DOES NOT RUN 2
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
TRANSFORMER - IGNITION
FAULT CODE RED BLINKING 2
HEAT EXCHANGER - PLATE
FAULT CODE RED SOLID
FAULT CODE - OVERHEAT
FAULT CODE BLINKING RED GREEN 2
SENSOR - NTC
DHW RADS BEGIN TO HEAT 2
CARTRIDGE
DHW RADS BEGIN TO HEAT 3
ACTUATOR
CH OPERATION 2
ACTUATOR
CH OPERATION
ACTUATOR
DHW RADS BEGIN TO HEAT
CARTRIDGE
DHW RADS BEGIN TO HEAT 2
ACTUATOR
FAULT CODE RED SOLID 3
HARNESS - WIRING
FAULT CODE RED SOLID 6
HARNESS - WIRING
BURNER DOES NOT IGNITE 3
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE 2
HARNESS & PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE 2
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
HARNESS & PRINTED CIRCUIT BOARD
STOPPING PRESEQ BREAKING
Z DIRECTION
DIVERTER VOLTAGE SATISFACTORY
RESULT AS EXPECTED
DIVERTER RESISTANCE SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR VOLTAGE SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR SATISFACTORY
RESULT AS EXPECTED
FAN SPEED CONTROL RESISTANCE SATISFACTORY
RESULT AS EXPECTED
FAULT CODE A03 (QADAI)
PRINTED CIRCUIT BOARD
FAULT CODE A03 2 (QADAI)
PRINTED CIRCUIT BOARD
FAN SPEED CONTROL VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FAN VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FAN RESISTANCE SATISFACTORY
RESULT AS EXPECTED
PUMP VOLTAGE SATISFACTORY
RESULT AS EXPECTED
PUMP RESISTANCE SATISFACTORY
RESULT AS EXPECTED
GAS VALVE VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FLUE THERMISTOR SATISFACTORY
RESULT AS EXPECTED
DHW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
RETURN THERMISTOR SATISFACTORY
RESULT AS EXPECTED
FLOW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
DIAG LITE 1
Z REDIRECT
QADAI 2
Z REDIRECT
GAS VALVE RESISTANCE SATISFACTORY (SIEMENS)
RESULT AS EXPECTED
GAS VALVE RESISTANCE SATISFACTORY (SIT)
RESULT AS EXPECTED
FUSE FIURTHER INVESTIGATION 2
Z REDIRECT
LEDS DO NOT WORK
HARNESS - WIRING
FUSE FIURTHER INVESTIGATION
Z REDIRECT
FUSE FIURTHER INVESTIGATION 3
Z REDIRECT
NO LEDS NO FAN
PRINTED CIRCUIT BOARD
LEDS DO NOT WORK
PRINTED CIRCUIT BOARD
SHORT TO EARTH NO DISPLAY
SENSOR - PRESSURE
SHORT TO EARTH NO DISPLAY
THERMOSTAT - HIGH LIMIT
ONL Y 1 ATTEMPT TO IGNITE
PRINTED CIRCUIT BOARD
FAULT CODE / NOTIFICATION PRESENT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
LEDS DO NOT ILLUMINATE
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BOILER ATTEMPTS TO FIRE AFTER SELF CHECK COMPLETE - NO DEMAND PRESENT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
BOILER GOES TO FAULT CODE RED LED BLINKING BEFORE 80 °C
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
TEMPERATURE EXCEEDS 85 °C & CONTINUES TO FIRE
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
BOILER ATTEMPTS TO IGNITE 5 TIMES BEFORE LOCKOUT OCCURS
CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED
FAN RUNS - FAULT CODE OCCURS APPROXIMATELY 15 SECONDS AFTER FAN STARTS
CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
GAS RATE UNSATISFACTORY
CHARACTERISTIC TEST FROM GAS RATE
UNABLE TO GAS RATE (E.G. LPG INSTALLATION WITH NO METER)
CHARACTERISTIC TEST FROM GAS RATE
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
DETECTION ELECTRODE - INCORRECT GAP AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
IGNITION ELECTRODE - INCORRECT GAP AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
HEADER FOR DIAGNOSTICS LITE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA AND INFORMATION
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FLOW THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA RETURN THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA DHW THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FLUE THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA GAS VALVE VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA GAS VALVE RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA PUMP RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
HEADER FOR QUICK ACCESS DATA PUMP VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA DIVERTER RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA DIVERTER VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
NEEDED OR PRESEQ MESSES UP DIVERTER VOLTAGE FOR SOME REASON
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
LEDS STOP WORKING WHEN CN9 RECONNECTED
CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS
LEDS STOP WORKING WHEN C10 RECONNECTED
CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS
LEDS STOP WORKING WHEN CN11 RECONNECTED
CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS
BOILER GOES TO SOLID RED LOCKOUT AFTER ONLY ONE IGNITION ATTEMPT
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
BOILER REACHES TEMPERATURE - RADIATORS DO NOT HEAT OR ONLY GET WARM
CHARACTERISTIC TEST FROM CH OPERATION
BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW - BOILER REMAINS LIT
CHARACTERISTIC TEST FROM CH OPERATION
EXCESSIVE SYSTEM PRESSURE RISE AS SYSTEM HEATS
CHARACTERISTIC TEST FROM CH OPERATION
DHW COOL - RADIATORS REMAIN COOL OR DO NOT INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW COOL - RADIATORS BEGIN TO HEAT OR INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
DHW RUNS HOT THEN COOL
CHARACTERISTIC TEST FROM DHW OPERATION
11/11/2022 11:43:26 2209_2_50_1 21/11/2022 09:20:12
11/11/2022 14:27:56
ISOLATED COLD FEED (BOILER)
ISOLATE COLD FEED TO BOILER
ENSURE NO DEMANDS
RESISTANCE DHW FLOW SWITCH
DISCONNECT 1X ELECTRICAL CONNECTOR TO THE DHW FLOW SWITCH
ENSURE NO DEMANDS
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
VOLTAGE DHW FLOW SENSOR - DEMAND
GAIN ACCESS TO DHW FLOW SENSOR CONNECTIONS
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
VOLTAGE DETECTION ELECTRODE AT PCB
{GAINPCBACS}
VOLTAGE DETECTION ELECTRODE DISCONNECTED AT PCB
REMOVE DETECTION ELECTRODE CONNECTION FA2
FROM THE PCB & MAKE SAFE
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE PUMP
REMOVE PUMP ELECTRICAL COVER
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY
RESISTANCE FAN
REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.
RESISTANCE DIVERTER VALVE ACTUATOR
REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR
RESISTANCE GAS VALVE AND HARNESS (SIEMENS - VALVE) - FUSE
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE GAS VALVE (SIT - VALVE) - FUSE
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE GAS VALVE (SIEMENS - VALVE) - FUSE
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
RESET APPLIANCE
ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL
RESISTANCE OVERHEAT STAT & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE WIRING HARNESS CN11
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE FLUE TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE FLUE TEMPERATURE SENSOR
REMOVE CONNECTOR FROM THE FLUE SENSOR
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
OBSERVATION - PREHEAT TURNED OFF
DISENGAGE DHW CONTRO
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
RESISTANCE DHW TEMPERATURE SENSOR HARNESS
REMOVE ELECTRICAL CONNECTOR TO DHW TEMPERATURE SENSOR
& CONNECTOR CN9 FROM THE PCB
OBSERVATION DIVERTER VALVE OPERATION DHW (2X LOCKING PIN)
REMOVE ACTUATOR FROM THE 3-WAY VALVE ASSEMBLY & PLACE IN A SAFE POSITION TO OBSERVE ITS OPERATION
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
OBSERVATION DIVERTER VALVE OPERATION CH (2X LOCKING PIN)
REMOVE ACTUATOR FROM THE 3-WAY VALVE ASSEMBLY & PLACE IN A SAFE POSITION TO OBSERVE ITS OPERATION
VOLTAGE DIVERTER VALVE AT PCB (CH)
{GAINPCBACS}
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
RESISTANCE FLUE TEMPERATURE SENSOR
REMOVE CONNECTOR FROM THE FLUE SENSOR
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT
RESISTANCE GAS VALVE AND HARNESS (SIEMENS - VALVE)
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE GAS VALVE (SIEMENS - VALVE)
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE GAS VALVE (SIT - VALVE)
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE GAS VALVE (SIEMENS - VALVE)
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
VOLTAGE MAINS INPUT - PCB
{GAINPCBACS}
RESISTANCE FUSED SPUR
REMOVE FUSE FROM FUSED SPUR
FUSE FURTHER INVESTIGATION - FUSED SPUR
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - MAINS INPUT
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - F1 PCB FUSE
THE INFORMATION PROV
DISCONNECT DHW FLOW SWITCH
DISCONNECT 1X CONNECTOR TO THE DHW FLOW SWITCH & MAKE SAFE
ENSURE NO DEMANDS
DISCONNECT EXTERNAL CONTROLS
{GAINPCBACS}
DISCONNECT EXTERNAL CONTROLS FROM CONNECTOR CN5 & MAKE SAFE
NO DEMANDS
RESISTANCE DHW FLOW SWITCH & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
ENSURE NO DEMANDS
TEMPERATURE FLOW PIPE - FROST PROTECTION
ATTACH FGA TEMPERATURE SENSOR TO THE BOILER'S FLOW PIPE
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
RESISTANCE HARNESS DHW FLOW SENSOR
REMOVE CONNECTOR CN9 FROM THE PCB
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
RESISTANCE PUMP HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
DISCONNECT ELECTRICAL CONNECTIONS AT PUMP
OBSERVATION GAS VALVE OPENS
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
ENSURE NO DEMANDS
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
OBSERVATION SPARKING OCCURS
REMOVE ELECTRODE LEA
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB & ELECTRICAL CONNECTOR AT GAS VALVE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
VOLTAGE DETECTION ELECTRODE
ENSURE NO DEMANDS
INSPECTION DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
INSPECTION EXPANSION VESSEL PRESSURE
DRAIN BOILER PRIMARY SYSTEM WATER
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE FAN AND HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE DIVERTER VALVE ACTUATOR & HARNESS
REMOVE CONNECTOR CN4 FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS (SIT - VALVE) - FUSE
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE PUMP HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
DISCONNECT ELECTRICAL CONNECTIONS AT PUMP
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
OBSERVATION CH - OVERHEAT OCCUR
ATTACH FGA TEMPERATURE CLAMP TO THE FLOW PIPE
RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESET APPLIANCE - SOLID RED LED
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESET APPLIANCE - RED & GREEN BLINKING
ENSURE NO DEMANDS ARE PRESENT
RESET APPLIANCE - GREEN LED BLINKING
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE
INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION IGNITION ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM BOILER
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
RESISTANCE SPARK GENERATOR HARNESS
REMOVE CN1 FROM THE PCB
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
VOLTAGE DIVERTER VALVE AT PCB (CH)
{GAINPCBACS}
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION DIVERTER VALVE SPINDLE (1X LOCKING PIN)
ACTUATOR REMOVED AND PRIMARY WATER DRAINED FROM PREVIOUS TEST
RESISTANCE FLUE TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
RESISTANCE GAS VALVE AND HARNESS (SIT - VALVE)
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS (QADAI)
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLUE TEMPERATURE SENSOR
REMOVE CONNECTOR FROM THE FLUE SENSOR
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
RESISTANCE PUMP
REMOVE PUMP ELECTRICAL COVER
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE FAN
REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE FAN SPEED CONTROL AND HARNESS (QADAI)
{GAINPCBACS}
DISCONNECT CN10 AT PCB
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
RESISTANCE DIVERTER VALVE ACTUATOR
REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR
VOLTAGE DIVERTER VALVE AT PCB (QADAI)
{GAINPCBACS}
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
DIAGNOSTICS LITE
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW
OBSERVATION GAS VALVE TYPE? DUMMY
OUTSIDE MODEL
RESISTANCE GAS VALVE (SIT - VALVE)
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
OBSERVATION IS FAN RUNNING CONSTANTLY
REMOVE COMBUSTION COVER
RESISTANCE FUSE - PCB
REMOVE FUSE FROM PCB
RESISTANCE FUSE - MAINS INPUT
REMOVE MAINS INPUT FUSE FROM TERMINAL BLOCK
OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS
{GAINPCBACS}
DISC
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT