4704455 VAILLANT ECOTEC PRO 28 H COMBI HEP

GLOBALLY REPLACED

Next: &1, *

NO FAULT FOUND

Next: nff

OBSERVATION DISPLAY ILLUMINATES

ON OFF SWITCH ON (SWITCH FLUSH WITH THE FASCIA ON THE APPLIANCE)

Next: &655, ?2791, ?2817

DHW FLOW RATE

Next: &542, f104

OBSERVATION FAN RUNS

Next: &177, f1357

OBSERVATION BURNER IGNITION AND ESTABLISH

Next: &2498, ?183, ?185, ?187

OPERATION DHW

Next: &2477, ?278, ?280, ?282, ?284

OPERATION CH

CH THERMOSTAT SET TO MAX

Next: &495, ?438, ?440, ?442

OBSERVATION CH DEMAND RECOGNISED

ENSURE EXTERNAL CONTROLS ARE CALLING FOR HEAT

Next: &437, f1512

OBSERVATION SYSTEM PRESSURE RISE

BOILER CH THERMOSTAT TO MAX

Next: &501, f496

OBSERVATION WARMSTART OPERATION

ENSURE APPLIANCE PRI

Next: &nff, ?503, ?505

OBSERVATION DHW DEMAND RECOGNISED

TURN HOT WATER TAP ON WITH A FLOW RATE OF 4 L/MIN

Next: &554, f543

OBSERVATION DOES PUMP RUN

Next: &137, !f555

OBSERVATION SELF CHECK

NO DEMANDS
ENSURE WARM START TURNED OFF
ENSURE CH TURNED OFF

Next: &2042, ?659, ?661, ?1878, ?1921, ?2848

HEADER FOR F75 FAULT CODE

INTENTIONALLY BLANK HEADER

Next: &nff, f3178

USER DISPLAY GUIDE

THE USER DISPLAY ON

Next: &556, !f656

HEADER FOR F22

INTENTIONALLY BLANK HEADER

Next: &nff, f3066

HEADER FOR F00,F01,F10,F11,F64,F71,F85

INTENTIONALLY BLANK HEADER

Next: &nff, f1851

F23, F24, F72, F83, F84

INTENTIONALLY BLANK HEADER

Next: &nff, f2090

HEADER FOR F13

INTENTIONALLY BLANK HEADER

Next: &nff, f762

HEADER FOR F70

INTENTIONALLY BLANK HEADER

Next: &nff, f792

HEADER FOR F27, F62

INTENTIONALLY BLANK HEADER

Next: &nff, f850

HEADER FOR F32

INTENTIONALLY BLANK HEADER

Next: &nff, f856

HEADER FOR F20

INTENTIONALLY BLANK HEADER

Next: &nff, f1836

HEADER FOR F49

INTENTIONALLY BLANK HEADER

Next: &nff, f938

HEADER FOR F61

INTENTIONALLY BLANK HEADER

Next: &nff, f1593

HEADER FOR FUSE INVESTIGATION

INTENTIONALLY BLANK HEADER

Next: &nff, f1607

HEADER FOR COMMUNICATION FAULT

INTENTIONALLY BLANK HEADER

Next: &nff, f1022

USER DISPLAY GUIDE

THE USER DISPLAY ON

Next: &nff, !f1031

CALLING UP THE INSTALLER LEVEL

Next: &nff, !f1444

TYPE OF DIAGNOSTIC PROCEDURE

Next: &97, !f2043

HEADER FOR F73, F74

INTENTIONALLY BLANK HEADER

Next: &nff, f3048

HEADER FOR F76

INTENTIONALLY BLANK HEADER

Next: &nff, f2733

COMBUSTION PERFORMANCE ANALYSIS

CONNECT FGA TO THE C

Next: &444, f2518

PRESSURE GAS INLET

ATTACH PRESSURE GAUG

Next: &277, !f2499

HEADER FOR F68

INTENTIONALLY BLANK HEADER

Next: &nff, f3237

HEADER FOR F77

INTENTIONALLY BLANK HEADER

Next: &nff, !f3326

COMMUNICATION FAULT

PCB

Next: End

NO COMMUNICATION

CABLE - DISPLAY

Next: End

BLANK FOR USER DISPLAY GUIDE FOR PREHEAT

Z DIRECTION CHOICE OR CONTINUE

Next: End

NOT RECOGNISING DHW DEMAND

SENSOR FITMENT

Next: End

BAFFLING OUT (BLOCKED)

PIPE - INLET - AIR

Next: End

BURNER BAFFLING

GAS INLET PRESSURE

Next: End

DIVERTER VALVE MOTOR

HARNESS - WIRING X2

Next: End

DIVERTER VALVE MOTOR CH

HARNESS - WIRING X2

Next: End

NOISY

PUMP

Next: End

NOISY CH

PUMP

Next: End

BOILER TO TEMP RADS COLD

PUMP

Next: End

NOT ESTABLISHING

GAS INLET PRESSURE

Next: End

NOT RECTIFYING

CABLE - IGNITION

Next: End

NOT RECTIFYING

ELECTRODE

Next: End

CAUSING NO RECTIFICATION

BURNER

Next: End

IGNITES BUT DOES NOT ESTABLISH

PIPE - INLET - AIR

Next: End

POOR DHW FLOW

VALVE - CONTROL

Next: End

DHW FLOW RATE

COLD WATER SUPPLY

Next: End

NO DEMAND TO FAN

SENSOR - NTC CH FLOW / CH RETURN

Next: End

FAN DOES NOT RUN

PCB

Next: End

FAN DOES NOT RUN

HARNESS - WIRING X20

Next: End

NO DEMAND FOR FAN

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

DHW OPERATION

SENSOR - NTC CH FLOW / CH RETURN

Next: End

DHW OPERATION

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

DHW TOO COOL

SENSOR - NTC CH FLOW / CH RETURN

Next: End

DHW TOO COOL

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

SLOW OR WEAK

PUMP

Next: End

DHW TOO COOL RADS COLD EXCESSIVE DIFFERENTIAL

FILTER PRIMARY CIRCUIT

Next: End

CALLING UP THE INSTALLER LEVEL

Z DIRECTION CHOICE OR CONTINUE

Next: End

USING CHECK PROGRAMMES

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F32

PCB

Next: End

FAULT CODE F32 2

PCB

Next: End

FAULT CODE F32 1

PCB

Next: End

FAULT CODE F32

HARNESS - WIRING X20

Next: End

FAULT CODE F61

GAS SECTION

Next: End

FAULT CODE F61

PCB

Next: End

F49

PCB

Next: End

FAULT CODE F49

PCB

Next: End

DHW COOL RADS COOL

SYSTEM PRESSURE

Next: End

DHW RUNS HOT THEN COLD

SYSTEM PRESSURE

Next: End

F20

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

F20

SENSOR - NTC CH FLOW / CH RETURN

Next: End

F20

CABLE - IGNITION

Next: End

F20

ELECTRODE

Next: End

LOW PRESSURE

SYSTEM PRESSURE

Next: End

FAULT CODE F70

PCB

Next: End

F13

PCB

Next: End

F13

SENSOR - NTC - DHW HEAT EXCHANGER

Next: End

D 071

ADJUSTMENT DIAGNOSTIC CODE

Next: End

D000

ADJUSTMENT DIAGNOSTIC CODE

Next: End

DIAGNOSTIC CODE D002

Z DIRECTION CHOICE OR CONTINUE

Next: End

FUSE FURTHER INVESTIGATION 1

CABLE - PUMP

Next: End

FUSE FURTHER INVESTIAGTION

CABLE - PUMP

Next: End

F00 F01 F10 F11 F64 F71 F85

SENSOR FITMENT

Next: End

FAULT CODES

SENSOR - NTC CH FLOW / CH RETURN

Next: End

FAULT CODES

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

TYPE OF DIAGNOSTIC PROCEDURE

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLANK FOR FAULT CODES 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

F23 F24 F83 F84

SYSTEM PRESSURE

Next: End

F23 F24 F83 F84

SENSOR - NTC CH FLOW / CH RETURN

Next: End

F23 F24 F83 F84

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

OVERHEAT

CABLE - PUMP

Next: End

CLOSED TOO MUCH OR BLOCKED

BY-PASS

Next: End

EXCESSIVE DIFFERENTIAL AND TEMP RISE FAULT CODE

FILTER PRIMARY CIRCUIT

Next: End

BLANK FOR CASE OFF

Z DIRECTION CHOICE OR CONTINUE

Next: End

WEAK

PUMP

Next: End

PUMP DOES NOT OVERRUN

PCB

Next: End

F23 F24 F83 F84

SENSOR FITMENT

Next: End

OVERHEAT

SERVICE VALVES (COCK)

Next: End

DIAGNOSTIC CODE D001

Z DIRECTION CHOICE OR CONTINUE

Next: End

PUMP RUNS CONTINUOUSLY

SENSOR FITMENT

Next: End

PUMP RUNS CONTINUOUSLY

SENSOR - NTC CH FLOW / CH RETURN

Next: End

PUMP RUNS CONTINUOUSLY

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

TOO LOW

GAS INLET PRESSURE

Next: End

PERFORMANCE TEST FAIL

PIPE - INLET - AIR

Next: End

PERFORMANCE TEST FAIL

CONDENSATE SYPHON

Next: End

PERFORMANCE TEST FAIL

FLUE ASSEMBLY

Next: End

PERFORMANCE TEST FAIL

COMBUSTION SEALS

Next: End

PERFORMANCE TEST FAIL

BURNER

Next: End

PERFORMANCE TEST FAIL

HEAT EXCHANGER

Next: End

PERFORMANCE TEST FAIL

COMBUSTION ADJUSTMENT

Next: End

BAFFLING

HEAT EXCHANGER

Next: End

BAFFLING

BURNER

Next: End

BAFFLING

CONDENSATE SYPHON

Next: End

BAFFLING

FLUE ASSEMBLY

Next: End

DHW RUNS HOT THEN COLD

SENSOR FITMENT

Next: End

DHW RUNS HOT THEN COLD

SENSOR - NTC CH FLOW / CH RETURN

Next: End

DHW RUNS HOT THEN COLD

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

DHW RUNS HOT THEN COLD

FILTER PRIMARY CIRCUIT

Next: End

SHUT CAUSING CH NOISE

BY-PASS

Next: End

F76

PCB

Next: End

F76

HARNESS - WIRING X20

Next: End

D 093

ADJUSTMENT DIAGNOSTIC CODE

Next: End

BLOWN STAND BY MODE AT POWER UP

FUSE (MAINS)

Next: End

HARNESS X20 AND X25

HARNESS - WIRING X20

Next: End

HARNESS X2

HARNESS - WIRING X2

Next: End

FUSE F1

FUSE F1

Next: End

OUT OF CAL STOPPING DHW DEMAND RECOGNITION

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

BURNER NOT IGNITING

GAS INLET PRESSURE

Next: End

SPARKING NOT LIGHTING

ELECTRODE

Next: End

HIGH FAN PRESSURE

PIPE - INLET - AIR

Next: End

RESTRICTED FAN PRESSURE

CONDENSATE SYPHON

Next: End

RESTRICTED FAN PRESSURE

BURNER

Next: End

RESTRICTED FAN PRESSURE

HEAT EXCHANGER

Next: End

RESTRICTED FAN PRESSURE

FLUE ASSEMBLY

Next: End

BURNER DOES NOT IGNITE

PCB AND GAS SECTION

Next: End

SPARKING BUT NOT LIGHTING

GAS SECTION

Next: End

POOR HOT WATER

EXTERNAL MIXING

Next: End

NOT SHUTTING BURNER DOWN CH

SENSOR - NTC CH FLOW / CH RETURN

Next: End

NOT SHUTTING BURNER DOWN CH

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

COMMUNICATION FAULT 1

PCB

Next: End

NO COMMUNICATION 1

CABLE - DISPLAY

Next: End

FAULT CODE F73 - F74

PCB

Next: End

F73 F74

HARNESS - WIRING X2

Next: End

FAULT CODE F73 F74

PCB

Next: End

F73 - F74

SYSTEM PRESSURE

Next: End

F22

SYSTEM PRESSURE

Next: End

MEASURING FLOW RATE AND TEMP RISES

Z DIRECTION CHOICE OR CONTINUE

Next: End

POOR HOT WATER

CONDENSATE SYPHON

Next: End

POOR HOT WATER

FLUE ASSEMBLY

Next: End

POOR HOT WATER

HEAT EXCHANGER

Next: End

POOR HOT WATER

PIPE - INLET - AIR

Next: End

POOR HOT WATER

BURNER

Next: End

POOR HOT WATER

FAN ASSEMBLY

Next: End

S34

SENSOR - NTC CH FLOW / CH RETURN

Next: End

S34

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

FROST PROTECTION

SENSOR - NTC CH FLOW / CH RETURN

Next: End

FROST PROTECTION

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

FAULTY FROST PROTECTION

PCB

Next: End

SPANNER ON THE DISPLAY

PCB

Next: End

NOT RECOGNISING DEMAND

BURNER OFF LINK

Next: End

FAULT CODE F70

ADJUSTMENT DIAGNOSTIC CODE

Next: End

D093 ADJUSTMENT

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F32 1

HARNESS - WIRING X20

Next: End

F32

HARNESS - WIRING X20

Next: End

SPEED CONTROL SHORTED

PUMP

Next: End

FAULT CODE F75

SYSTEM PRESSURE

Next: End

PUMP PULSING

SYSTEM PRESSURE

Next: End

NO VOLTAGE TO PUMP

PCB

Next: End

FAULT CODE F75

CABLE - PUMP

Next: End

FAULT CODE F68

CONDENSATE SYPHON

Next: End

FAULT CODE F68

FLUE ASSEMBLY

Next: End

FAULT CODE F68

CABLE - IGNITION

Next: End

FAULT CODE F68

ELECTRODE

Next: End

FAULTY

CONDENSATE PUMP

Next: End

SPANNER SHOWING 2

PCB

Next: End

DC HALL SENSOR

HARNESS - WIRING X20

Next: End

SPARKING

CABLE - IGNITION

Next: End

SPARKING

ELECTRODE

Next: End

DC HALL SENSOR CONDENSATE PUMP

HARNESS - WIRING X20

Next: End

SPARKING CONDENSATE PUMP

CABLE - IGNITION

Next: End

SPARKING CONDENSATE PUMP

ELECTRODE

Next: End

FAULT CODE F75

AIR VENT - AUTOMATIC

Next: End

FAULT CODE F75

EXPANSION VESSEL 10L

Next: End

DOES NOT RUN

PUMP

Next: End

FAULT CODE F75

FILTER PRIMARY CIRCUIT

Next: End

FAULT CODE F75

PUMP

Next: End

FAULT CODE F75 2

AIR VENT - AUTOMATIC

Next: End

FAULT CODE F75 2

EXPANSION VESSEL 10L

Next: End

FAULT CODE F75 2

FILTER PRIMARY CIRCUIT

Next: End

FAULTY CONDENSE PUMP

CONDENSATE FAULT CODE

Next: End

CH NOISY

SERVICE VALVES (COCK)

Next: End

TURNED OFF

SERVICE VALVES (COCK)

Next: End

CH STAYING TOO COOL

SENSOR - NTC CH FLOW / CH RETURN

Next: End

CH STAYING TOO COOL

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

FLAT

EXPANSION VESSEL 10L

Next: End

BOILER NOT RECOGNISING FACILITY

SENSOR - NTC - DHW HEAT EXCHANGER

Next: End

WARMSTART ISSUES

SENSOR - NTC CH FLOW / CH RETURN

Next: End

WARMSTART ISSUES

SENSOR - NTC - CH FLOW / CH RETURN

Next: End

WARM START NOT HOT ENOUGH

SENSOR - NTC - DHW HEAT EXCHANGER

Next: End

TO AQUA SENSOR

HARNESS - WIRING X2

Next: End

OUT OF CAL STOPING DHW DEMAND RECOGNITION

SENSOR - NTC CH FLOW / CH RETURN

Next: End

FOR USER DISPLAY GUIDE

Z DIRECTION CHOICE OR CONTINUE

Next: End

NOT OPENING TO RADS POSITION

VALVE - 3 WAY

Next: End

PASSING SOLENOIDS

GAS SECTION

Next: End

F27 F62

ELECTRODE

Next: End

NO COMMUNICATION

DISPLAY

Next: End

HEAT EXCHANGER - DHW

HEAT EXCHANGER - 13 PLATES - DHW

Next: End

FLOW LIMITER

LIMITER

Next: End

PASSING TO RADS

DIVERTER VALVE MOTOR

Next: End

PASSING TO RADS CH

DIVERTER VALVE MOTOR

Next: End

FILTER DHW

FILTER DHW

Next: End

BAFFLING

GAS SECTION

Next: End

NOT RUNNING WITH CORRECT VOLTAGES

FAN ASSEMBLY

Next: End

NOT CONTROLLING HW TEMP

PCB

Next: End

DHW TOO COOL

HEAT EXCHANGER

Next: End

DHW TOO COOL

HEAT EXCHANGER - 13 PLATES - DHW

Next: End

NOT RSPONDING TO CH DEMAND

EBUS CONTROL

Next: End

NOT RSPONDING TO CH DEMAND 3

EBUS CONTROL

Next: End

F32

FAULT CODE RESET

Next: End

FAULT CODE F32

FAN ASSEMBLY

Next: End

FAULT CODE F61

HARNESS - WIRING X20

Next: End

F61

FAULT CODE RESET

Next: End

F49

FAULT CODE RESET - F49

Next: End

FAULT CODE F49

EBUS CONTROL

Next: End

F20

FAULT CODE RESET

Next: End

F20 2

HARNESS - WIRING X20

Next: End

F20

HARNESS - WIRING X20

Next: End

F20

PCB

Next: End

SYSTEM PRESSURE FURTHER INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

DSN NUMBER

FAULT CODE RESET

Next: End

FAULT CODE F70

FACTORY RESET

Next: End

F13

FAULT CODE RESET

Next: End

F13

HARNESS - WIRING X2

Next: End

RAD TEMP LOW

Z DIRECTION CHOICE OR CONTINUE

Next: End

RADIATOR TEMP LOW

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLANK DISPLAY

FUSE FURTHER INVESTIGATION

Next: End

FUSE INVESTIGATION

PUMP

Next: End

F00 F01 F10 F11 F64 F71 F85

FAULT CODE RESET

Next: End

THERMISTOR FAULT CODES FLOW SENSOR

HARNESS - WIRING X20

Next: End

THERMISTOR FAULT CODES

PCB

Next: End

THERMISTOR FAULT CODES RETURN SENSOR

HARNESS - WIRING X20

Next: End

BLANK FOR FAULT CODES

Z DIRECTION CHOICE OR CONTINUE

Next: End

OVERHEAT DOES NOT RESET

PCB

Next: End

OVERHEAT

PUMP

Next: End

NOT RESPONDING TO CH DEMAND 4

EBUS CONTROL

Next: End

F23 F24 F83 F84

HEAT EXCHANGER

Next: End

F23 F24 F83 F84

HEAT EXCHANGER - 13 PLATES - DHW

Next: End

NOT REGISTERING PRESSURE

SENSOR - WATER PRESSURE

Next: End

BLOCKED OR RESTRICTED

SENSOR - WATER PRESSURE

Next: End

BLOCKED OR RESTRICTED

ADAPTOR

Next: End

PUMP RUNS CONTINUOUSLY

PCB

Next: End

PUMP RUNS CONTINUOUSLY

FROST PROTECTION - NORMAL OPERATION

Next: End

PUMP RUNS CONSTANT

PCB

Next: End

PERFORMANCE TEST FAIL

GAS SECTION

Next: End

COMBUSTION VALUES

Z DIRECTION CHOICE OR CONTINUE

Next: End

DHW RUNS HOT THEN COLD

PCB

Next: End

DHW RUNS HOT THEN COLD

HEAT EXCHANGER

Next: End

NOT RSPONDING TO CH DEMAND 2

EBUS CONTROL

Next: End

NOISY

HEAT EXCHANGER - 13 PLATES - DHW

Next: End

SCALED-NOISY

HEAT EXCHANGER

Next: End

NOISY CH

Next: End

F76

FAULT CODE RESET

Next: End

F76

LINK FOR FLUE GAS SAFETY TEMP LIMITER

Next: End

POOR HW

Z DIRECTION CHOICE OR CONTINUE

Next: End

FURTHER INVESTIGATION MAINS

Z DIRECTION CHOICE OR CONTINUE

Next: End

CAUSING BLANK DISPLAY

FAN ASSEMBLY

Next: End

AQUA SENSOR

SENSOR - FLOW

Next: End

BLANK DISPLAY

SENSOR - WATER PRESSURE

Next: End

DISPLAY PCB

DISPLAY

Next: End

HARNESS DISPLAY PCB

CABLE - DISPLAY

Next: End

PCB MAIN

PCB

Next: End

FURTHER INVESTIGATION FUSE F1

Z DIRECTION CHOICE OR CONTINUE

Next: End

NOT RECOGNISING DEMAND

PCB

Next: End

INCORRECT MIX

GAS SECTION

Next: End

FAN PRESSURE INCORRECT

FAN ASSEMBLY

Next: End

NO VOLTAGE TO GAS VALVE

PCB

Next: End

BURNER DOES NOT IGNITE

PCB AND HARNESS X20

Next: End

SPARKING BUT NOT LIGHTING

HARNESS - WIRING X20

Next: End

SOLENOID NOT OPENING

GAS SECTION

Next: End

DHW TOO COOL

PCB

Next: End

NO COMMUNICATION 1

DISPLAY

Next: End

FAULT CODE F73 - F74

SENSOR - WATER PRESSURE

Next: End

F73 F74

SENSOR - WATER PRESSURE

Next: End

F73 F74

ADAPTOR

Next: End

FAULT CODE F73 F74

SENSOR - WATER PRESSURE

Next: End

FAULT CODE F73 - F74

FAULT CODE RESET

Next: End

F72

SENSOR - WATER PRESSURE

Next: End

FAULT CODE F22

ADAPTOR

Next: End

FAULT CODE F22

SENSOR - WATER PRESSURE

Next: End

LOW SYSTEM PRESSURE

FAULT CODE RESET

Next: End

POOR HOT WATER

GAS SECTION

Next: End

OPERATION CORRECTLY

FROST PROTECTION - NORMAL OPERATION

Next: End

TAP OPEN OR LEAKING DHW DRAW OFF

TAP OPEN OR LEAKING DHW DRAW OFF

Next: End

SPANNER ON DISPLAY

MAINTENANCE INTERVAL SURPASSED

Next: End

FAULT CODE F70

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F32 1

FAN ASSEMBLY

Next: End

FAULT CODE F32 3

PCB

Next: End

SHORTED

CABLE - PUMP

Next: End

FAULT CODE F75 F75

PUMP

Next: End

F68

PCB

Next: End

SPANNER ON DISPLAY 2

MAINTENANCE INTERVAL SURPASSED

Next: End

HALL SENSOR SIGNAL

FAN ASSEMBLY

Next: End

NOT SPARKING

PCB

Next: End

HALL SENSOR SIGNAL CONDENSATE PUMP

FAN ASSEMBLY

Next: End

FAULTY 2

CONDENSATE PUMP

Next: End

FAULT CODE F75

SENSOR - WATER PRESSURE

Next: End

FAULT CODE F75 2

SENSOR - WATER PRESSURE

Next: End

PASSING TO RADS

VALVE - 3 WAY

Next: End

CH REMAINING TOO COOL

PCB

Next: End

BLOCKED

TUBE - EXPANSION VESSEL

Next: End

WARM START SENSOR

HARNESS - WIRING X2

Next: End

NOT SENSING DEMAND

SENSOR - FLOW

Next: End

F27 F62

PCB

Next: End

LIMITER BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION FLOW LIMITER AND FILTER

Next: !p114

FILTER BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION FLOW LIMITER AND FILTER

Next: !p116

DIFFERENTIAL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: !p1408

BOILER DOES NOT RESPOND TO CENTRAL HEATING

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p1563

24 VOLT EXTERNAL CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p1531

EBUS CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p1517

24 VOLT EXTERNAL CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p1566

EBUS CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p1568

FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - FAULT CODE F32

Next: p1580

FAN RUNS AND/OR STOPS AND RESTARTS - FAULT CODE F32 OCCURS

CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - FAULT CODE F32

Next: p1582

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p2856

BURNER IGNITES BUT DOES NOT ESTABLISH (FLAME SYMBOL DOES NOT APPEAR ON DISPLAY) - RECTIFICATION ISSUE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p1237

BURNER IGNITES BUT BAFFLES OUT/NOISY - COMBUSTION ISSUE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p1106

PUMP RUNS CONTINUOUSLY

CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK

Next: p2446

LOW SYSTEM PRESSURE DISPLAYED

CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK

Next: p1922

CON X22 PUMP SPEED CONTROL RESISTANCES NOT AS ABOVE

CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS

Next: p2019

CON X18 PUMP MAIN SUPPLY RESISTANCES NOT AS ABOVE

CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS

Next: p2021

DIFFERENTIAL EXCESSIVE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p2160

BOILER DOES NOT RESPOND TO CENTRAL HEATING

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p2162

24 VOLT EXTERNAL CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p2165

EBUS CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p2167

WATER PRESSURE SENSOR RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

Next: !p2371

ADAPTOR RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

Next: !p2373

STATUS CODE S.34 SHOWN

CHARACTERISTIC TEST FROM OBSERVATION WHICH STATUS CODE IS SHOWN

Next: !p2461

STATUS CODE S.96 OR S.98 SHOWN

CHARACTERISTIC TEST FROM OBSERVATION WHICH STATUS CODE IS SHOWN

Next: p2464

DIFFERENTIAL EXCESSIVE

CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS

Next: !p2699

BOILER DOES NOT RESPOND TO CENTRAL HEATING

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: p2701

24 VOLT EXTERNAL CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p2704

EBUS CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

Next: p2706

DIFFERENTIAL INCORRECT OR LOCAL NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISE

Next: !p2729

DIFFERENTIAL OK SYSTEM NOISE

CHARACTERISTIC TEST FROM DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISE

Next: !p2731

DHW TOO HOT

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p1392

DISPLAY ILLUMINATES BUT NO INFORMATION/TEXT ON SCREEN

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY ILLUMINATES

Next: p3036

TEMPERATURE RISE UNSATISFACTORY, RADIATORS REMAIN COOL

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p1888

DISPLAY DOES NOT ILLUMINATE

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY ILLUMINATES

Next: p2819

TEMPERATURE RISE UNSATISFACTORY, RADIATORS HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p283

DHW RUNS HOT THEN COLD

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p1752

BOILER COMPLETES SELF CHECK AS DESCRIBED BUT SPANNER ON THE DISPLAY

CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK

Next: p3246

ADAPTOR RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

Next: !p3060

WATER PRESSURE SENSOR RESTRCITED OR BLOCKED

CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS

Next: !p3062

ADAPTOR RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

Next: !p3075

WATER PRESSURE SENSOR RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

Next: !p3077

PUMP DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION PUMP BEHAVIOUR F75

Next: p3220

PUMP RUNS OR F75 OCCURING INTERMITTENTLY

CHARACTERISTIC TEST FROM OBSERVATION PUMP BEHAVIOUR F75

Next: p3183

BOILER NOISY

CHARACTERISTIC TEST FROM OPERATION CH

Next: p439

BOILER UP TO TEMP RADS COLD

CHARACTERISTIC TEST FROM OPERATION CH

Next: p470

BOILER AND SYSTEM TEMPERATURE LOW

CHARACTERISTIC TEST FROM OPERATION CH

Next: p1965

BOILER DOES NOT GIVE THE OPTION OF ACTIVATING WARMSTART

CHARACTERISTIC TEST FROM OBSERVATION WARMSTART OPERATION

Next: p504

BOILER DOES NOT HEAT SUFFICIENTLY ON WARM START

CHARACTERISTIC TEST FROM OBSERVATION WARMSTART OPERATION

Next: p506

BOILER FIRES WITH NO DEMAND

CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK

Next: p2423

FAULT CODE SHOWN

CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK

Next: p670

VOLTAGE TO DISPLAY PCB AT MAIN PCB

REMOVE THE DISPLAY HARNESS CONNECTOR FROM THE MAIN PCB

Next: p1023, !f1024

INSPECTION DHW ISOLATION VALVE

Next: p1257, !f1264

VOLTAGE DIVERTER VALVE

REMOVE CONNECTOR FROM THE DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS

Next: p1153, !f1151

VOLTAGE DIVERTER VALVE

REMOVE CONNECTOR FROM THE DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS

Next: p1157, !f1158

VOLTAGE DC PWM DEMAND AT FAN

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p1366, f1367

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p1368, !f1369

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p1406, ?1407, ?1409

OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

GAIN ACCESS TO THE PCB

Next: p1523, ?1514, ?1516

VOLTAGE TO 24V EXTERNAL CONTROLS

Next: !p1534, !f1535

VOLTAGE TO 24V EXTERNAL CONTROLS

Next: !p1573, !f1574

RESISTANCE GAS VALVE AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: p1594, f1595

RESISTANCE GAS VALVE

REMOVE THE LEFT HAND

Next: !p1596, !f1597

OBSERVATION ARE ANY EBUS CONTROLS FITTED

{GAINPCBACS}

Next: p1603, !f1604

RESISTANCE PUMP AND HARNESS

REMOVE CONNECTOR X22

Next: !p2017, ?2018, ?2020

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1837, f1838

RESISTANCE FLOW SENSOR AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: p1839, f1840

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: !p1841, !f1842

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p1845, !f1846

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2029, f2030

OBSERVATION IS THE DSN SET CORRECTLY - D.093

ENSURE NO DEMANDS

Next: p1950, f3156

RESISTANCE WARM START SENSOR

REMOVE THE CONNECTOR FROM THE WARM START SENSOR

Next: !p1960, !f1961

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: !p2035, !f2036

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p2039, !f2040

RESET APPLIANCE - ENSURE APPLIANCE IS COOL

ENSURE NO DEMANDS ARE PRESENT
ENSURE APPLIANCE IS COOL

Next: p2097, f2140

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p2141, !f2142

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p2150, !f2151

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p2158, ?2159, ?2161

VOLTAGE TO 24V EXTERNAL CONTROLS

Next: !p2172, !f2173

INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

DRAIN PRIMARY WATER

Next: !p2369, ?2370, ?2372

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p2519, !f2520

INSPECTION BURNER

REMOVE THE COMBUSTION FRONT ASSEMBLY

Next: p2529, !f2530

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p2697, ?2698, ?2700

VOLTAGE TO 24V EXTERNAL CONTROLS

Next: !p2711, !f2712

RESISTANCE HARNESS AND LINK FOR FLUE GAS SAFETY TEMP LIMITER

REMOVE CONNECTOR X20 FROM THE PCB

Next: p2745, f2748

RESISTANCE HARNESS FLUE GAS SAFETY TEMP LIMITER

REMOVE CONNECTOR X20 FROM THE PCB
DISCONNECT THE PLUG AT THE INLINE CONNECTOR (AS SHOWN)

Next: !p2750, !f2751

DIAGNOSTIC CODE D.093 SET CORRECTLY

THE DEVICE SPECIFIC

Next: !p2758, !f2759

RESISTANCE MAINS SUPPLY FUSE

REMOVE THE MAINS 3A FUSE FROM ITS HOLDER

Next: !p2822, f2823

FUSE FURTHER INVESTIGATION MAINS

Next: !p2824, !f2825

OBSERVATION RE ATTACH X2

REFIT CONNECTOR X2 (BLUE) TO THE PCB

Next: p2828, f2829

OBSERVATION RE ATTACH X20

REFIT CONNECTOR X20 (RED) TO THE PCB

Next: p2830, f2831

OBSERVATION RE ATTACH X22 BUT DISCONNECT PUMP SPEED CONTROL

REFIT CONNECTOR X22 TO THE PCB
DISCONNECT PUMP SPEED CONTROL FROM THE PUMP AND MAKE SAFE

Next: !p3176, !f3177

OBSERVATION DISCONNECT LOW WATER PRESSURE SENSOR

REMOVE THE CONNECTOR FROM THE LOW WATER
PRESSURE SWITCH AND MAKE SAFE

Next: !p2838, !f2839

VOLTAGE TO DISPLAY PCB AT MAIN PCB

REMOVE THE DISPLAY HARNESS CONNECTOR FROM THE MAIN PCB

Next: !p2842, f2843

RESISTANCE FUSE F1

REMOVE FUSE F1 FROM ITS HOLDER ON THE PCB

Next: !p2844, f2845

FUSE FURTHER INVESTIGATION F1

Next: !p2846, !f2847

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p2993, !f2994

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}

Next: p3004, f3005

RESISTANCE GAS VALVE AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: !p3006, f3007

RESISTANCE GAS VALVE

REMOVE THE LEFT HAND

Next: !p3008, !f3009

RESISTANCE GAS VALVE

REMOVE THE LEFT HAND

Next: !p3011, !f3012

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p3101, !f3110

OBSERVATION SYSTEM PRESSURE

Next: p3049, !f3065

VOLTAGE TO WATER PRESSURE SENSOR

Next: p3052, !f3053

INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

DRAIN PRIMARY WATER

Next: !p3058, ?3059, ?3061

OBSERVATION SYSTEM PRESSURE

Next: p3067, !f3080

VOLTAGE TO WATER PRESSURE SENSOR

Next: p3070, !f3071

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p3123, !f3124

DIAGNOSTIC CODE D.093 SET CORRECTLY

THE DEVICE SPECIFIC

Next: !p3157, !f3158

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3163, !f3164

OBSERVATION PUMP BEHAVIOUR F75

Next: p3179, ?3180, ?3182

INSPECTION CONDENSATE TRAP

Next: p3238, !f3242

OBSERVATION DISCONNECT CONDENSATE PUMP (SPANNER)

REMOVE THE TWO WIRES

Next: p3253, !f3254

OBSERVATION VAILLANT CONDENSATE PUMP FITTED (X40)

GAIN ACCESS TO THE PCB

Next: p3269, f3278

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3272, !f3273

OBSERVATION DISCONNECT CONDENSATE PUMP (SPARKING)

REMOVE IGNITION ELEC

Next: !p3300, f3291

VOLTAGE HALL SENSOR

{GAINPCBACS}

Next: p3292, f3293

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3294, !f3295

PRESSURE EXPANSION VESSEL

APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED

Next: !p497, !f498

RESISTANCE WARM START SENSOR

REMOVE THE CONNECTOR FROM THE WARM START SENSOR

Next: !p509, !f510

VOLTAGE DEMAND FROM AQUA SENSOR

{GAINPCBACS}
ENSURE A FLOW RATE ABOVE 3 LITRES PER MINUTE

Next: p1043, f545

VOLTAGE TO AQUA SENSOR

Next: p546, !f547

RESISTANCE WARM START SENSOR AND HARNESS

REMOVE CONNECTOR X2 FROM THE PCB

Next: p1956, f1959

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1948, f1949

OBSERVATION BURNER EXTINGUISH

Next: p852, !f851

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: p891, !f1577

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1601, f1602

RESISTANCE HARNESS DISPLAY PCB

REMOVE DISPLAY HARNESS FROM X51 CONNECTIONS

Next: !p1025, !f1026

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p188, !f1070

PRESSURE GAS INLET

ATTACH PRESSURE GAUG

Next: p1050, !f1128

INSPECTION FLOW LIMITER AND FILTER

DHW SUPPLY ISOLATED

Next: !p112, ?113, ?115

RESISTANCE DIVERTER VALVE HARNESS

REMOVE CONNECTOR X2 FROM THE PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE MOTOR

Next: !p1154, !f1155

RESISTANCE DIVERTER VALVE HARNESS

REMOVE CONNECTOR X2 FROM THE PCB
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE MOTOR

Next: !p1159, !f1160

PUMP LIMPET

Next: p285, !f1178

PUMP LIMPET

Next: p461, !f1189

PUMP LIMPET

Next: p535, !f1194

INSPECTION AIR INTAKE TUBE

REMOVE AIR INTAKE TUBE

Next: p1238, !f1247

PRESSURE GAS INLET

ATTACH PRESSURE GAUG

Next: p1239, !f1240

RESISTANCE IGNITION LEAD

REMOVE THE IGNITION LEAD FROM THE PCB
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE

Next: p1241, !f1242

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: p1243, !f1244

INSPECTION BURNER

REMOVE THE COMBUSTION FRONT ASSEMBLY

Next: !p1245, !f1246

OBSERVATION COLD WATER SUPPLY

Next: p111, !f1265

INSPECTION CONDENSATE TRAP

Next: p1341, !f2627

INSPECTION BURNER

REMOVE THE COMBUSTION FRONT ASSEMBLY

Next: p1343, !f2626

INSPECTION PRIMARY HEAT EXCHANGER FLUEWAYS

REMOVE THE BURNER DOOR ASSEMBLY

Next: !p1345, !f2625

VOLTAGE FAN 22VDC AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p1374, !f1375

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p1390, !f1391

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p1376, !f1377

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p1393, !f1394

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p1395, !f1396

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p1398, !f1399

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: p1400, !f1401

PUMP LIMPET

Next: p1402, !f1403

TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: p3014, f1405

INSPECTION FILTER PRIMARY CIRCUIT

APPLIANCE DRAINED AND DISCHARGED

Next: !p1419, !f1420

DISCONNECT EBUS CONTROLS - CH DEMAND

DISCONNECT EBUS WIRING FROM CONNECTOR X100 AND MAKE SAFE

Next: !p1536, !f1537

VOLTAGE FROM 240V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p1529, !f1530

VOLTAGE FROM 24V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p1532, f1533

OBSERVATION D.000 - ADJUSTABLE HEATING PARTIAL LOAD

ENSURE NO DEMANDS

Next: p443, f1988

OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

GAIN ACCESS TO THE PCB

Next: p1564, ?1565, ?1567

VOLTAGE FROM 240V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p1575, !f1576

VOLTAGE FROM 24V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p1571, f1572

DISCONNECT EBUS CONTROLS - CH DEMAND

DISCONNECT EBUS WIRING FROM CONNECTOR X100 AND MAKE SAFE

Next: !p1569, !f1570

VOLTAGE DC PWM DEMAND AT FAN

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p1583, !f1584

VOLTAGE HALL SENSOR

{GAINPCBACS}

Next: p3161, f3162

VOLTAGE FAN 22VDC AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p1585, !f1586

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p1587, !f1588

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1598, !f1599

DISCONNECT EBUS CONTROLS

DISCONNECT EBUS WIRING FROM CONNECTOR X100 AND MAKE SAFE

Next: !p1605, !f1606

OBSERVATION SYSTEM PRESSURE

Next: p1397, !f1751

OBSERVATION SYSTEM PRESSURE

Next: p1778, !f1804

RESISTANCE RETURN SENSOR AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: p1843, f1844

RESISTANCE IGNITION LEAD

REMOVE THE IGNITION LEAD FROM THE PCB
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE

Next: p1847, !f1848

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: !p1849, !f1850

INSPECTION FLUE

Next: p1340, !f2628

OBSERVATION IS THE DSN SET CORRECTLY - D.093

ENSURE NO DEMANDS

Next: p1713, f2757

SYSTEM PRESSURE FURTHER INVESTIGATION

THE SYSTEM PRESSURE

Next: !p1925, !f1926

FACTORY RESET - MAIN PCB

Next: !p1954, !f1955

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1957, !f1958

DIAGNOSTIC CODE D.000 SET CORRECTLY

THE HEATING PARTIAL

Next: !p1990, !f2002

DIAGNOSTIC CODE D.071 SET CORRECTLY

THE TARGET VALUE MAX

Next: !p1995, !f1996

RESISTANCE PUMP SPEED CONTROL HARNESS

REMOVE CONNECTOR X22

Next: !p2022, !f2023

RESISTANCE PUMP MAIN SUPPLY HARNESS

REMOVE CONNECTOR X18

Next: !p2024, !f2025

RESISTANCE FLOW SENSOR AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: p2033, f2034

RESISTANCE RETURN SENSOR AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: !p2037, f2038

OBSERVATION SYSTEM PRESSURE

Next: p2098, !f2099

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p2143, !f2144

OBSERVATION DOES PUMP RUN

Next: p2148, f2149

PUMP LIMPET

Next: p2183, !f2211

RESISTANCE PUMP MAIN SUPPLY HARNESS

REMOVE CONNECTOR X18

Next: !p2152, !f2153

TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: !p2156, f2157

INSPECTION FILTER PRIMARY CIRCUIT

APPLIANCE DRAINED AND DISCHARGED

Next: !p2180, !f2181

INSPECTION EXTERNAL BYPASS

Next: p2176, !f2177

OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

GAIN ACCESS TO THE PCB

Next: p2163, ?2164, ?2166

VOLTAGE FROM 240V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p2174, !f2175

VOLTAGE FROM 24V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p2170, f2171

DISCONNECT EBUS CONTROLS - CH DEMAND

DISCONNECT EBUS WIRING FROM CONNECTOR X100 AND MAKE SAFE

Next: !p2168, !f2169

INSPECTION INTEGRAL BYPASS

APPLIANCE DRAINED AND DISCHARGED

Next: !p2178, !f2179

OBSERVATION PUMP OVERRUN

ENSURE CH CONTROLS ARE CALLING FOR HEAT

Next: p2154, !f2212

INSPECTION FLOW AND RETURN VALVES

Next: p2147, !f2252

OBSERVATION WHICH STATUS CODE IS SHOWN

Next: !p2459, ?2460, ?2462

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p2467, !f2468

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p2469, !f2470

INSPECTION CONDENSATE TRAP

Next: p2521, !f2522

INSPECTION FLUE

Next: p2523, !f2524

INSPECTION COMBUSTION SEALS

Next: p2525, !f2526

OBSERVATION CAN COMBUSTION BE ADJUSTED

CONNECT FGA TO THE C

Next: p2527, f2528

COMBUSTION VALUES CORRECTLY ADJUSTED

THE COMBUSTION READI

Next: !p2533, !f2534

INSPECTION PRIMARY HEAT EXCHANGER FLUEWAYS

REMOVE THE BURNER DOOR ASSEMBLY

Next: !p2531, !f2532

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p2663, !f2693

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: p1163, !f2694

INSPECTION FILTER PRIMARY CIRCUIT

APPLIANCE DRAINED AND DISCHARGED

Next: !p2715, !f2716

OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED ?

GAIN ACCESS TO THE PCB

Next: p2702, ?2703, ?2705

VOLTAGE FROM 240V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p2713, !f2714

VOLTAGE FROM 24V EXTERNAL CONTROLS

{GAINPCBACS}
ENSURE ALL EXTERNAL CONTROLS ARE CALLING

Next: !p2709, f2710

DISCONNECT EBUS CONTROLS - CH DEMAND

DISCONNECT EBUS WIRING FROM CONNECTOR X100 AND MAKE SAFE

Next: !p2707, !f2708

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER FOR CH NOISE

ATTACH TEMPERATURE C

Next: p3031, ?2728, ?2730

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2746, !f2747

VOLTAGE MAINS POWER INPUT TO APPLIANCE

{GAINPCBACS}

Next: p2820, f2821

OBSERVATION REMOVE CONNECTORS FROM PCB

REMOVE CONNECTORS X20 (RED) X2 (BLUE) AND X22 FROM
THE PCB AND MAKE SAFE

Next: p2826, f2827

OBSERVATION DISCONNECT AQUA SENSOR

REMOVE THE CONNECTOR FROM THE AQUA SENSOR AND MAKE SAFE

Next: !p2836, f2837

INSPECTION DIVERTER VALVE MOTOR OPERATION

REMOVE THE DIVERTER

Next: !p356, f1149

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p2834, !f2835

INSPECTION BURNER OFF LINK

Next: p3152, !f3155

TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER

ATTACH TEMPERATURE C

Next: !p2695, f2696

PRESSURE GAS INLET

ATTACH PRESSURE GAUG

Next: p2885, !f2895

OBSERVATION IS SPARKING PRESENT

REMOVE IGNITION ELEC

Next: p2932, f3259

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: p2946, !f2968

PRESSURE FAN

ATTACH PRESSURE TUBE

Next: p2969, f2992

PRESSURE FAN - EQUALISATION

ATTACH PRESSURE TUBE

Next: !p2991, f3003

INSPECTION CONDENSATE TRAP

Next: p2995, !f2996

INSPECTION BURNER

REMOVE THE COMBUSTION FRONT ASSEMBLY

Next: p2997, !f2998

INSPECTION PRIMARY HEAT EXCHANGER FLUEWAYS

REMOVE THE BURNER DOOR ASSEMBLY

Next: p2999, !f3000

INSPECTION FLUE

Next: !p3001, !f3002

RESISTANCE GAS VALVE AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: !p3013, f3010

GAS RATE

Next: p3015, f3016

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p3032, !f3033

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p3034, !f3035

VOLTAGE TO DISPLAY PCB AT MAIN PCB

REMOVE THE DISPLAY HARNESS CONNECTOR FROM THE MAIN PCB

Next: p3037, !f3038

RESISTANCE HARNESS DISPLAY PCB

REMOVE DISPLAY HARNESS FROM X51 CONNECTIONS

Next: !p3039, !f3040

VOLTAGE FROM WATER PRESSURE SENSOR

{GAINPCBACS}

Next: p3050, f3051

OBSERVATION ADJUST PRIMARY SYSTEM PRESSURE

LOCATE SYSTEM FILING LOOP

Next: p3056, f3057

RESISTANCE WATER PRESSURE SENSOR HARNESS

REMOVE CONNECTOR X2 FROM THE PCB
REMOVE CONNECTOR FROM THE LOW WATER PRESSURE SWITCH

Next: !p3054, !f3055

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p3063, !f3064

OBSERVATION ADJUST SYSTEM PRESSURE

{GAINPCBACS}
LOCATE THE SYSTEM FILLING LOOP

Next: p3068, f3069

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p3078, !f3079

INSPECTION WATER PRESSURE SENSOR AND ADAPTOR

DRAIN PRIMARY WATER

Next: !p3072, ?3074, ?3076

INSPECTION CONDENSATE TRAP

Next: p3102, !f3103

INSPECTION FLUE

Next: p3104, !f3105

INSPECTION BURNER

REMOVE THE COMBUSTION FRONT ASSEMBLY

Next: p3111, !f3115

INSPECTION PRIMARY HEAT EXCHANGER FLUEWAYS

REMOVE THE BURNER DOOR ASSEMBLY

Next: !p3108, !f3109

INSPECTION FAN

Next: p3106, !f3116

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p3118, !f3119

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p3120, !f3121

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: p3125, !f3126

OBSERVATION DHW DEMAND INCORRECTLY RECOGNISED

HOT WATER TAPS OFF

Next: p3127, !f3128

OBSERVATION ISOLATE MAINS WATER - DOES DEMAND STOP ?

TURN OFF THE DHW ISOLATION VALVE

Next: !p3129, !f3130

RESISTANCE FAN HARNESS

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE THE DC FAN CONNECTOR FROM THE FAN ASSEMBLY

Next: !p3165, !f3166

OBSERVATION SYSTEM PRESSURE

Next: p3308, !f3205

OBSERVATION SYSTEM PRESSURE

Next: p3317, !f3185

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p3221, !f3222

RESISTANCE PUMP MAIN SUPPLY HARNESS

REMOVE CONNECTOR X18

Next: !p3223, !f3224

INSPECTION FLUE

Next: p3239, !f3243

RESISTANCE IGNITION LEAD

REMOVE THE IGNITION LEAD FROM THE PCB
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE

Next: p3240, !f3244

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: !p3241, !f3245

OBSERVATION VAILLANT CONDENSATE PUMP FITTED (BURNER OFF)

GAIN ACCESS TO THE PCB

Next: p2849, f3252

VOLTAGE HALL SENSOR

{GAINPCBACS}

Next: p3270, f3271

RESISTANCE IGNITION LEAD

REMOVE THE IGNITION LEAD FROM THE PCB
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE

Next: p3274, !f3275

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: !p3276, !f3277

RESISTANCE IGNITION LEAD

REMOVE THE IGNITION LEAD FROM THE PCB
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE

Next: p3296, !f3297

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: !p3298, !f3299

PRESSURE EXPANSION VESSEL

APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED

Next: p3311, !f3312

INSPECTION PUMP IMPELLER

BOILER PRIMARY CIRCUIT DRAINED AS NECESSARY

Next: p3313, !f3314

INSPECTION FILTER PRIMARY CIRCUIT

APPLIANCE DRAINED AND DISCHARGED

Next: !p3315, !f3316

PUMP LIMPET

Next: p3318, !f3319

PRESSURE EXPANSION VESSEL

APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED

Next: p3322, !f3323

INSPECTION FILTER PRIMARY CIRCUIT

APPLIANCE DRAINED AND DISCHARGED

Next: !p3324, !f3325

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p490, !f492

INSPECTION INTEGRAL BYPASS

APPLIANCE DRAINED AND DISCHARGED

Next: p2726, !f2732

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p491, !f493

RESISTANCE WARM START SENSOR AND HARNESS

REMOVE CONNECTOR X2 FROM THE PCB

Next: !p507, f508

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p511, !f513

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: p515, !f514

RESISTANCE WARM START SENSOR

REMOVE THE CONNECTOR FROM THE WARM START SENSOR

Next: !p516, !f517

INSPECTION DIVERTER VALVE MOTOR OPERATION

REMOVE THE DIVERTER

Next: p686, f1156

INSPECTION EXTERNAL BYPASS

Next: p1190, !f531

OBSERVATION CLOSE INTEGRAL BYPASS

CLOSE THE INTEGRAL B

Next: !p692, !f537

RESISTANCE FLOW SENSOR

REMOVE THE CONNECTOR FROM THE FLOW SENSOR (RED)

Next: p550, !f551

RESISTANCE CHECK AQUA SENSOR HARNESS

REMOVE THE CONNECTOR FROM THE AQUA SENSOR
REMOVE CONNECTOR X2 FROM THE PCB

Next: !p548, !f549

RESISTANCE RETURN SENSOR

REMOVE THE CONNECTOR FROM THE RETURN SENSOR (BLUE)

Next: !p2854, !f2855

FAULT CODES

Next: !p2046, !f2047

INSPECTION DIVERTER VALVE SPINDLE

REMOVE THE DIVERTER VALVE MOTOR FROM THE BODY

Next: p530, !f693

INSPECTION EXTERNAL BYPASS

Next: p1179, !f778

INSPECTION SPARK ELECTRODE

REMOVE THE SPARK ELECTRODE ASSEMBLY

Next: !p854, !f853

OBSERVATION FAN RUNS - FAULT CODE F32

Next: !p1578, ?1579, ?1581