Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
IDEAL STELRAD TURBO 2-24KW
G.C. NUMBER 41 429 4
CENTRAL HEATING OPERATION
BOILER SWITCH IN ON POSITION
MAIN BURNER IGNITES
BOILER SWITCH IN THE ON POSITION
MAIN BURNER ON NEON
BOILER SWITCH IN THE ON POSITION
AIR PRESSURE OK NEON
BOILER SWITCH IN ON POSITION
BOILER NEON ON
BOILER SWITCH IN ON POSITION
OVERHEAT CONDITION: COLD
BOILER SWITCH IN ON POSITION
BOILER OVERHEAT NEON
{ISOLATEMAINSPOWER}<
ON/OFF SWITCH NEON
BOILER SWITCH IN THE ON POSITION
EXTERNAL PUMP RUN CHECK
BOILER SWITCH IN THE ON POSITION
ALL BOILER AND EXTERNAL CONTROLS ARE CALLING FOR HEAT
SYSTEM CHECKS
{ISOLATEMAINSPOWER}
PLEASE ENSURE THAT THE FOLLOWING SYSTEM CHECKS ARE COMPLETED
IDEAL STELRAD TURBO 2-24KW
{ISOLATEMAINSPOWER}<
ELECTRICAL CHECK
ELECTRICAL CHECK
SYSTEM CHECKS
SYSTEM CHECKS
EXTERNAL PUMP RUN CHECK
PUMP SUPPLY
ON/OFF SWITCH NEON
BOILER SWITCH
BOILER OVERHEAT NEON
BOILER OVERHEAT NEON
OVERHEAT CONDITION: COLD
FLUE THERMOSTAT
OVERHEAT CONDITION:COLD
SUMP FAN OVERHEAT THERMOSTAT
BOLIER NEON ON
FUSE
BOILER NEON ON
AIR PRESSURE SWITCH
BOILER NEON ON
PRINTED CIRCUIT BOARD NO.7
SUMP FAN RUNNING
SUMP FAN CONNECTION
AIR PRESSURE OK NEON
BURNER FAN CONNECTOR
AIR PRESSURE OK NEON
AIR PRESSURE SWITCH TUBES
MAIN BURNER ON NEON
PRINTED CIRCUIT BOARD NO.7
MAIN BURNER ON NEON
ELECTRODE LEAD
MAIN BURNER ON NEON
PILOT SOLENOID: GV1
MAIN BURNER ON NEON
GAS VALVE
OVERHEATED
PUMP
FLAME SENSE
PRINTED CIRCUIT BOARD NO.7
PCB NO. 7 (FLAME SENSE)
PCB NO. 7 (FLAME SENSE)
HEAT EXCHANGER NOISY
PUMP
AIR PRESSURE OK NEON
CONDENSATE
AIR PRESSURE OK NEON
FLUE
OVERHEAT CONDITION: COLD
OVERHEAT THERMOSTAT
BOILER ON NEON
PRINTED CIRCUIT BOARD NO.7
BOILER NEON ON
BOILER CONTROL THERMOSTAT
BOILER NEON ON
BURNER ON NEON
SUMP FAN RUNNING
SUMP FAN
AIR PRESSURE OK NEON
BURNER FAN
AIR PRESSURE OK NEON
AIR PRESSURE SWITCH NEON
MAIN BURNER ON NEON
ELECTRODE
MAIN BURNER ON NEON
PILOT INJECTOR
FLAME SENSE
BURNER ON NEON
MAIN BURNER IGNITES
BURNER PLAQUES
CENTRAL HEATING OPERATION
HEAT EXCHANGER
CENTRAL HEATING OPERATION
SUMP FAN OVERHEAT THERMOSTAT
CENTRAL HEATING OPERATION
FLUE THERMOSTAT
MAIN BURNER IGNITES
MAIN GAS VALVE SOLENOID: GV2
CENTRAL HEATING OPERATION
OVERHEAT THERMOSTAT
AIR PRESSURE OK NEON
AIR PRESSURE SWITCH
DOES NOT LIGHT
CHARACTERISTIC TEST FROM MAIN BURNER IGNITES
LIGHTS NOISILY
CHARACTERISTIC TEST FROM MAIN BURNER IGNITES
HEAT EXCHANGER NOISY
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
HEAT EXCHANGER QUIET
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
OVERHEATED
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
23/01/2018 09:09:18 1801_1_50_1 31/01/2018 09:46:31
26/01/2018 10:46:25
MAINS POWER SUPPLY (240V INPUT)
BOILER SWITCH IN OFF POSITION
BOILER THERMOSTAT OUTPUT
BOILER SWITCH IN ON POSITION
PCB7 PIN 3: AIR PRESSURE SWITCH (N/C)
BOILER SWITCH IN THE ON POSITION
FUSE
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
FAN RUNNING
BOILER SWITCH IN ON POSITION
FAN INPUT VOLTAGE
BOILER SWITCH IN ON POSITION
AIR PRESSURE SWITCH TUBES
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
PILOT IGNITES
BOILER SWITCH IN ON POSITION
PILOT SPARKING
BOILER SWITCH IN ON POSITION
SPARK GENERATOR
BOILER SWITCH IN ON POSITION
PUMP RUNNING (HOT)
BURNER SWITCH IN ON POSITION
ALL BOILER AND EXTERNAL CONTROLS ARE CALLING FOR HEAT
SUMP
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
WATER PUMP VOLTAGE
BOILER SWITCH IN ON POSITION.
SUMP FAN OVERHEAT THERMOSTAT - COLD
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
PCB7 PIN 2: FAN VOLTAGE
BOILER SWITCH IN ON POSITION
AIR PRESSURE SWITCH: NO AIR
{ISOLATEMAINSPOWER}<
AIR PRESSURE SWITCH: AIR DETECT
BOILER SWITCH IN THE ON POSITION.
FLAME SENSE
BOILER SWITCH IN ON POSITION
PILOT SOLENOID GV1
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
REMOVE RED AND BLUE LEADS FROM SOLENOID
SPARK ELECTRODE LEAD
{ISOLATEMAINSPOWER}
REMOVE ELECTRODE LEAD FROM ELECTRODE AND PCB
PILOT GAS SUPPLY
{ISOLATEMAINSPOWER}<
PCB7 PIN 6: MAIN GAS VALVE VOLTAGE
BOILER SWITCH IN ON POSITION
OVERHEAT THERMOSTAT (HOT)
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
OVERHEAT THERMOSTAT (HOT)
{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
System Information
- Total Tests: 93
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control