VAILLANT ECOTEC PLUS
GLOBALLY REPLACED
VAILLANT ECOTEC PLUS
CASE REMOVAL<
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
PUMP RUNS CH DEMAND
CH THERMOSTAT SET TO 70°C
BURNER IGNITES AND ESTABLISHES
ON-OFF SWITCH ON
CH OPERATION
ON/OFF SWITCH ON
CH MODULATION
CH TEMP CONTROL SET TO 60°C
BOILER ON, NO DEMAND (ANTI FROST PROTECTION)
ON-OFF SWITCH ON
ENSURE ALL EXTERNAL CONTROLS ARE OFF
FUSE 1 3AMP FUSED SPUR
REMOVE FUSE FROM FUSED SPUR
F67 FAULT CODE
OUT OF MODEL
F70 FAULT CODE
OUT OF MODEL
F49 FAULT CODE
OUT OF MODEL
F61 / F62 FAULT CODE
HEADER FOR FAULT CODE - OUTSIDE MODEL
F76 FAULT CODE
OUT OF MODEL
F22 FAULT CODE
OUT OF MODEL
GAS RATE
BURNER
GAS RATE
HEAT EXCHANGER
GAS RATE1BOILER NOISY
CONDENSATE TRAP OR DRAIN
GAS RATE1BOILER NOISY
BURNER
GAS RATE1BOILER NOISY
HEAT EXCHANGER
BACKED UP PREVENTING IGNITION
CONDENSATE TRAP OR DRAIN
SPARKING NO IGNITION
ELECTRODE
BURNER DOES NOT IGNITE
HEAT EXCHANGER
BURNER DOES NOT ESTABLISH
GAS SUPPLY
BLOWN STAND BY MODE AT POWER UP
MAINS FUSE
BURNER BAFFLES OUT
GAS SUPPLY
SPARKING ABSENT
CABLE
SPARKING OCCURS
FAN
CASE REMOVAL
DIRECTION CHOICE OR CONTINUE
BOILER TEMP LOW SYS LOW
GAS SUPPLY
UNDER PRESSURE
EXPANSION VESSEL
BOILER NOISY
SYSTEM PRESSURE
BOILER NOISY
GAS VALVE
BOILER TEMP LOW SYSTEM TEMP LOW
SENSOR - NTC - CH FLOW/CH RETURN
BOILER GETS TOO COOL BEFORE REFIRING
SENSOR - NTC - CH FLOW/CH RETURN
BOILER TEMP LOW SYSTEM TEMP LOW
SENSOR - NTC - CH FLOW/CH RETURN
BOILER GETS TOO COOL BEFORE REFIRING
SENSOR - NTC - CH FLOW/CH RETURN
CH MODULATION
SENSOR - NTC - CH FLOW/CH RETURN
CH MODULATION
SENSOR - NTC - CH FLOW/CH RETURN
TEMP BELOW 5 DEGREE
ANTIFROST ACTIVATED
FROST
SENSOR - NTC - CH FLOW/CH RETURN
FROST
SENSOR - NTC - CH FLOW/CH RETURN
PUMP OVERUN
SENSOR - NTC - CH FLOW/CH RETURN
PUMP OVERUN
SENSOR - NTC - CH FLOW/CH RETURN
FOR TYPE DIAG PROCEDURE
DIRECTION CHOICE OR CONTINUE
FAULT CODES
DIRECTION CHOICE OR CONTINUE
F1 F10 FAULT CODE
SENSOR - NTC - CH FLOW/CH RETURN
F67 FAULT CODE
PCB
F70 FAULT CODE
RESET TO FACTORY PARAMETERS
F49 FAULT CODE
INSPECT CONNECTIONS TO EBUS CONTROLLER
NO SHUT DOWN
GAS VALVE
OVERHEAT 2
SENSOR - NTC - CH FLOW/CH RETURN
OVERHEAT 2
SENSOR - NTC - CH FLOW/CH RETURN
PUMP
PCB
NO PUMP
HARNESS PUMP
NO FAN
SENSOR - NTC - CH FLOW/CH RETURN
NO FAN
CABLE TREE - HARNESS
NO FAN
PCB
F11
SENSOR - NTC - CH FLOW/CH RETURN
DRY FIRE
SYSTEM WATER/ PRESSURE
BOILER GETS TOO COOL BEFORE REFIRINGDRY FIRE
SENSOR - NTC - CH FLOW/CH RETURN
BOILER GETS TOO COOL BEFORE REFIRINGDRY FIRE
SENSOR - NTC - CH FLOW/CH RETURN
F22 DRY FIRE
PUMP
BOILER NOISYBOILER NOISY
SENSOR - NTC - CH FLOW/CH RETURN
BOILER NOISYBOILER NOISY
SENSOR - NTC - CH FLOW/CH RETURN
PUMPF22
PCB
NO PUMPF22
HARNESS PUMP
NO PUMPBOILER UP TO TEMP RADS COLD
HARNESS PUMP
BOILER NOISYPUMP
PCB
BOILER NOISYNO PUMP
HARNESS PUMP
NO PUMPF76 FAULT CODE
HARNESS PUMP
FAN RUNS DHW
SENSOR - NTC - CH FLOW/CH RETURN
BLOWN STANDBY MODE AT POWER UP
FUSE MAIN PCB
NO DISPLAY
PCB
F61
GAS VALVE
F62
GAS VALVE
F61 GAS VALVE
PCB
OVERHEAT
SENSOR - NTC - CH FLOW/CH RETURN
OVERHEAT
SENSOR - NTC - CH FLOW/CH RETURN
COMBUSTION CHAMBER OVERHEAT
CONDENSATE TRAP OR DRAIN
SPLIT / LEAKING
FLUE COLLECTOR / SEALS
BURNER DOES NOT ESTABLISH
CONDENSATE TRAP OR DRAIN
BURNER DOES NOT ESTABLISH
ELECTRODE
BURNER DOES NOT ESTABLISH
HEAT EXCHANGER
BURNER BAFFLES OUT
CONDENSATE TRAP OR DRAIN
BURNER BAFFLES OUT
FLUE
BURNER BAFFLES OUT
BURNER
BURNER BAFFLES OUT
HEAT EXCHANGER
GAS RATE
CONDENSATE TRAP OR DRAIN
GAS RATE
FLUE
BLOCKED OR DAMAGED
BURNER
WARPED AWAY FROM BURNER 2
ELECTRODE
WRONG MIX NOT IGNITING
GAS VALVE
SPARKING NO IGNITION
GAS SUPPLY
MECHANICAL
GAS VALVE
NO POWER TO GAS VALVE
CABLE TREE - HARNESS
FURTHER INVESTIGATION F1
Z DIRECTION CHOICE OR CONTINUE
SPARKING OCCURS
ELECTRODE
SPARKING ABSENT
PCB
SYS TEMP RESTART
PCB
EXPANSION CONNECTION
BLOCKAGE - PIPE TO EXPANSION VESSEL
OVERHEAT
BOILER OVERHEAT
CH MODULATION
PCB
ANTI FROST
PCB
PUMP OVERRUN
PCB
SENSOR PRIMARY F1/F10 FAULT CODE
CABLE TREE - HARNESS
SENSOR TEMP RETURN F11/13 FAULT CODE
CABLE TREE - HARNESS
F67 RETEST BOILER
DIRECTION CHOICE OR CONTINUE
F70 RETEST BOILER
DIRECTION CHOICE OR CONTINUE
F49 RETEST BOILER
DIRECTION CHOICE OR CONTINUE
OVERHEAT
TEMPERATURE OVERHEAT
OVERHEAT
PCB
PUMP
PUMP
SENSOR PRIMARY FAN RUNS
CABLE TREE - HARNESS
NOT RUNNING
FAN
FUSE 1
SYSTEM WIRING
GAS VALVE F1
CABLE TREE - HARNESS
BOILER TEMP LOW
GAS VALVE
NO FAN 2
PCB
BOILER NOISYBOILER NOISY
GAS VALVE
CH OPERATION NOISYBOILER NOISY
HEAT EXCHANGER
PUMPF22
PUMP
BOILER NOISYPUMP
PUMP
PUMPF76 FAULT CODE
PUMP
SENSOR TEMP RETURN FAN RUNS
CABLE TREE - HARNESS
MAINS FUSE
FUSE GONE PCB
F1
CABLE TREE - HARNESS
FURTHER IN VESTIGATION F2
Z DIRECTION CHOICE OR CONTINUE
NO DISPLAY
DISPLAY
F61 FAULT CODE
CABLE TREE - HARNESS
RETEST BOILER
DIRECTION CHOICE OR CONTINUE
OVERHEAT2
PCB
BURNER DOES NOT ESTABLISH
BURNER
WARPED AWAY FROM BURNER
ELECTRODE
BAFFLE
GAS VALVE
SPARKING OCCURS BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
FAN RUNS SPARKING DOES NOT OCCUR
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE GAP
ELECTRODE GAP FROM BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE GAP
INLET PRESSURE DOES NOT DIP TO INDICATE GAS VALVE IS OPENING
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP
INLET PRESSURE UNSATISFACTORY
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DIP
BURNER IGNITES BUT BAFFLES OUT OR LIFTS OFF
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BOILER NOISY
CHARACTERISTIC TEST FROM CH OPERATION
BOILER UP TO TEMP RADS COLD
CHARACTERISTIC TEST FROM CH OPERATION
SYSTEM PRESSURE RISE EXCESSIVE
CHARACTERISTIC TEST FROM CH OPERATION
BOILER TEMP LOW SYSTEM TEMP LOW
CHARACTERISTIC TEST FROM CH OPERATION
OPERATION SATISFACTORY, BUT GETS TOO COOL BEFORE REFIRING
CHARACTERISTIC TEST FROM CH OPERATION
OPERATION SATISFACTORY BUT BOILER GOES TO OVERHEAT
CHARACTERISTIC TEST FROM CH OPERATION
TEMP DIFF CORRECT LOCAL BOILING
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
DIFFERENTIAL OK
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE GAP
ELECTRODE GAP FROM BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE GAP
08/06/2021 15:42:03 2106_1_50_1 14/07/2021 11:20:40
05/07/2021 09:58:30
GAS VALVE VOLTAGE (PCB)
{GAINPCBACS}
ON-OFF SWITCH ON
FAN TEST PRESSURE
ATTACH PRESSURE GAUGE TO GAS VALVE OUTLET PRESSURE TEST POINT
ON-OFF SWITCH ON
VOLTAGE FAN PERMANENT AT PCB
{GAINPCBACS}
DISC
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
EXTERNAL CONTROLS
{GAINPCBACS}
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE GAS VALVE SOLENOID MAIN AND HARNESS
DISCONNECT PLUG MARKED X20 FROM THE PCB
RESISTANCE GAS VALVE SOLENOID MAIN
REMOVE THE PLUG FROM THE GAS VALVE
RESISTANCE SENSOR TEMP FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
LOCKOUT RESET F 67
ON-OFF SWITCH ON
LOCKOUT RESET F 70
ON-OFF SWITCH ON
LOCKOUT RESET F 49
ON-OFF SWITCH ON
RESISTANCE GAS VALVE SOLENOID MAIN AND HARNESS
DISCONNECT PLUG MARKED X20 FROM THE PCB
BOILER UP TO TEMP ON HW_CH DOES BOILER FUNCTION WITHOUT OVERHEATING
BOILER TEMPERATURE C
VOLTAGE MAINS POWER INPUT TO APPLIANCE
{GAINPCBACS}
EXTERNAL VOLTAGE INTO BOILER
{GAINPCBACS}
RESISTANCE SENSOR TEMP FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
SYSTEM FULL OF WATER
CHECK RADIATORS, AIRING CUPBOARD AND PIPEWORK
CHECK MANUAL AND AUTO VENTS
FAN TEST PRESSURE
ATTACH PRESSURE GAUGE TO GAS VALVE OUTLET PRESSURE TEST POINT
ON-OFF SWITCH ON
VOLTAGE AT PCB PUMP
{GAINPCBACS}
VOLTAGE AT PCB PUMP
{GAINPCBACS}
RESISTANCE FUSE F1 (FUSED SPUR)
REMOVE THE FUSE FROM THE FUSED SPUR
VOLTAGE AT PCB PUMP
{GAINPCBACS}
VOLTAGE AT PCB PUMP
{GAINPCBACS}
RESISTANCE FAN
REMOVE CONNECTOR X20
RESISTANCE GAS VALVE SOLENOID MAIN
REMOVE THE PLUG FROM THE GAS VALVE
INSPECTION BURNER
REMOVE THE BURNER
PRESSURE GAS INLET AND DIP
ATTACH PRESSURE GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
ON-OFF SWITCH ON
INSPECTION BURNER AND ELECTRODE GAP
REMOVE BURNER DOOR ASSEMBLY FROM APPLIANCE
SPARKING PRESENT CH
ON-OFF SWITCH ON
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
ON/OFF SWITCH ON
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
ON/OFF SWITCH ON
VOLTAGE FAN SPEED
ON-OFF SWITCH ON
SYSTEM PRESSURE
PRESSURE GAUGE MAYBE REMOTE TO THE BOILER
EXPANSION VESSEL PRESSURE
SYSTEM DISCHARGED
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
ON/OFF SWITCH ON
VOLTAGE BOILER SWITCHED LIVE OPERATION REFIRE
{GAINPCBACS}
TEMPERATURE SYSTEM FLOW
SET CH THERMOSTAT TO 50°C
ATTACH A TEMPERATURE PROBE TO THE FLOW PIPE CLOSE TO THE BOILER
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
COMBUSTION TEST
ON-OFF SWITCH ON
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
RESISTANCE PUMP AND HARNESS
DISCONNECT X18 FROM PCB
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
VOLTAGE AT PCB PUMP
{GAINPCBACS}
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
VOLTAGE FAN CONTROL
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY
(PLACE IN A SAFE POSITION)
ON-OFF SWITCH ON
RESISTANCE FAN HARNESS
DISCONNECT X20 FROM THE PCB
DISCONNECT THE FAN CONNECTOR FROM THE FAN ASSEMBLY
RESISTANCE SENSOR TEMP RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
TEMPERATURE DIFFERENTIAL FLOW RETURN
TURN CH TEMPERATURE
PUMP RUNS CH DEMAND
CH THERMOSTAT SET TO 70°C
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
PUMP RUNS CH DEMAND
CH THERMOSTAT SET TO 70°C
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
PUMP RUNS CH DEMAND
CH THERMOSTAT SET TO 70°C
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
PUMP RUNS CH DEMAND
CH THERMOSTAT SET TO 70°C
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
RESISTANCE FAN AND HARNESS
REMOVE CONNECTOR X20 FROM PCB
RESISTANCE FUSE F2 ( APPLIANCE)
REMOVE FUSE FROM FUSE AND HOLDER FROM PCB
VOLTAGE TO DISPLAY
BOTH TEMPERATURE DIALS UP TO MAX
LOCKOUT RESET F61 / F62
ON-OFF SWITCH ON
RESISTANCE SENSOR TEMP FLOW
LOCATE THE FLOW THER
RESISTANCE SENSOR TEMP RETURN
REMOVE THE TWO CONNECTORS (ONE BLACK WIRE AND ONE BLUE)
FROM THE THERMISTOR
INSPECTION BURNER AND ELECTRODE GAP
REMOVE BURNER DOOR ASSEMBLY FROM APPLIANCE
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION BURNER
REMOVE THE BURNER