INTERGAS COMBI COMPACT ECO RF 30

GLOBALLY REPLACED

Next: &24, *

FUSE INVESTIGATION TREE

OUTSIDE MODEL

Next: &nff, f2

FAULT CODE 29, 30 - GAS VALVE RELAY FAULTY

OUTSIDE MODEL

Next: &nff, f22

FAULT CODE 2 - S1 AND S2 INTERCHANGED

OUTSIDE MODEL

Next: &nff, f17

FAULT CODE 1 - TEMPERATURE TOO HIGH

OUTSIDE MODEL

Next: &nff, f370

FAULT CODE 0 - SENSOR FAULT AFTER SELF CHECK

OUTSIDE MODEL

Next: &nff, f328

CASE OFF

Next: &27, !f25

OBSERVATION DISPLAY OPERATES AND SELF CHECK

ENSURE NO DEMANDS

Next: &34, ?28, ?30, ?40, ?240

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &59, !f35

OBSERVATION BOILER RUNS FOR DHW

Next: &67, ?42, ?44, ?46

OBSERVATION DHW FLOW RATE

Next: &38, f60

OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: &68, ?73, ?104, ?123

OPERATION DHW

Next: &157, ?147, ?149, ?153, ?155

OBSERVATION DHW MODULATION

Next: &473, f158

OPERATION CH

Next: &396, ?186, ?188, ?208, ?355

OBSERVATION PUMP OVERRUN

Next: &nff, !f221

PRESSURE SYSTEM COLD

Next: &177, ?293, ?295, ?297

OBSERVATION CH MODULATION

Next: &219, f397

INFORMATION HOW TO SET MULTIMETER TO DIODE TEST

THE IMAGES BELOW SHO

Next: &nff, !f417

OBSERVATION PREHEAT OPERATION

Next: &292, !f474

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE

HEAT EXCHANGER ASSEMBLY (FLUEWAYS)

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH

HEAT EXCHANGER ASSEMBLY (FLUEWAYS)

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH

MODULE - IGNITION - SIEMENS SMART

Next: End

OPERATION DHW - TOO HOT

NTC - DHW

Next: End

OBSERVATION DHW MODULATION

NTC - DHW

Next: End

OPERATION DHW - TOO COOL

NTC - DHW

Next: End

OPERATION DHW - DHW COOL RADS COOL

GAS INLET PRESSURE

Next: End

FAULT CODE 4

Z REDIRECT

Next: End

FAULT CODE 5

Z REDIRECT

Next: End

OPERATION CH - NOISY

PUMP - YONOS

Next: End

FAULT CODE 6

Z REDIRECT

Next: End

OPERATION CH - UP TO TEMP RADS COOL

PUMP - YONOS

Next: End

OPERATION CH - DOES NOT REACH TEMP - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

OPERATION CH - DOES NOT REACH TEMP - RETURN

NTC 1 -2 (FLOW & RETURN)

Next: End

OBSERVATION PUMP OVERRUN

PCB - CONTROL

Next: End

FAULT CODE PAGE 2

Z REDIRECT

Next: End

INFORMATION CASE REMOVAL

Z REDIRECT

Next: End

INSPECTION SYSTEM PRESSURE AT TEMPERATURE

EXPANSION VESSEL

Next: End

PRESSURE SYSTEM COLD

CABLE - NTC

Next: End

PRESSURE SYSTEM COLD - IGNORING SENSOR

PCB - CONTROL

Next: End

FUSE INVESTIGATION

PUMP - YONOS

Next: End

FAULT CODE 10 11 12 13 14

PCB - CONTROL

Next: End

FAULT CODE 10 11 12 13 14

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 20 21 22 23 24

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 20 21 22 23 24

PCB - CONTROL

Next: End

FAULT CODE 0 - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 0

PCB - CONTROL

Next: End

FAULT CODE 0 - RETURN

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 8 - NO VOLTAGE TO FAN

PCB - CONTROL

Next: End

FAULT CODE 8 - FAN DOES NOT RUN

CABLE - FAN

Next: End

TYPE OF DIAGNOSTIC PROCEDURE

Z REDIRECT

Next: End

FAULT CODE 8 - FAN RUNS

CABLE - FAN

Next: End

FAULT CODE 29 30

PCB - CONTROL

Next: End

FAULT CODE 2

NTC 1 -2 (FLOW & RETURN) - FITMENT

Next: End

FAULT CODE 2 - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 2 - RETURN

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 2

PCB - CONTROL

Next: End

FAULT CODE 1 - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 1 - RETURN

NTC 1 -2 (FLOW & RETURN)

Next: End

OPERATION CH - DISPLAY REMAINS ON - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

OPERATION CH - DISPLAY REMAINS ON 1 - RETURN

NTC 1 -2 (FLOW & RETURN)

Next: End

OPERATION CH - NOISY

AIR IN BOILER / SYSTEM

Next: End

OPERATION CH - UP TO TEMP RADS COOL

AIR IN BOILER / SYSTEM

Next: End

OBSERVATION CH MODULATION - FLOW

NTC 1 -2 (FLOW & RETURN)

Next: End

FAULT CODE 1

PCB - CONTROL

Next: End

FUSE INVESTIGATION

GAS VALVE VGU 76S - SIEMENS SMART

Next: End

FUSE INVESTIGATION

MODULE - IGNITION - SIEMENS SMART

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES

HEAT EXCHANGER ASSEMBLY (FLUEWAYS)

Next: End

OPERATION DHW - DHW COOL RADS COOL

HEAT EXCHANGER ASSEMBLY (FLUEWAYS)

Next: End

OPERATION DHW - DHW COOL RADS COOL

BURNER BRAIDED STAINLESS STEEL

Next: End

OBSERVATION PREHEAT OPERATION

PCB - CONTROL

Next: End

OPERATION DHW - DHW COOL RADS COOL

EXTERNAL MIXING

Next: End

FUSE INVESTIGATION - EARTH

MODULE - IGNITION - SIEMENS SMART

Next: End

OPERATION CH - NOISY

PCB PARAMETERS

Next: End

OPERATION CH - UP TO TEMP RADS COOL

PCB PARAMETERS

Next: End

OPERATION CH - DOES NOT REACH TEMP

PCB PARAMETERS

Next: End

OPERATION CH - UP TO TEMP RADS COOL

VALVE - RETURN AND VALVE - FLOW

Next: End

OBSERVATION DHW FLOW RATE

WATER SUPPLY

Next: End

OBSERVATION DHW FLOW RATE

VALVE - WATER - COLD

Next: End

OBSERVATION DHW FLOW RATE

FLOW SENSOR - SIKA

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE

GAS VALVE VGU 76S - SIEMENS SMART AND PCB - CONTROL

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES

GAS VALVE VGU 76S - SIEMENS SMART

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT IGNITE

BURNER BRAIDED STAINLESS STEEL

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH

BURNER BRAIDED STAINLESS STEEL

Next: End

OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES

BURNER BRAIDED STAINLESS STEEL

Next: End

OPERATION DHW - DHW COOL RADS HEAT

PCB - CONTROL

Next: End

OPERATION DHW - TOO HOT

PCB - CONTROL

Next: End

OPERATION DHW - NOISY

HEAT EXCHANGER (WATERWAYS)

Next: End

OBSERVATION DHW MODULATION

PCB - CONTROL

Next: End

OBSERVATION PUMP RUNS CH DEMAND

PUMP - YONOS

Next: End

OPERATION CH - NOISY

HEAT EXCHANGER (WATERWAYS)

Next: End

FAULT CODE PAGE 1

Z REDIRECT

Next: End

OBSERVATION DISPLAY OPERATES AND SELF CHECK

SENSOR - PRESSURE - CH (BLOCKAGE)

Next: End

OBSERVATION BOILER RUNS FOR DHW - HALL SENSOR

SET - REPLACEMENT - FAN

Next: End

OBSERVATION BOILER RUNS FOR DHW - NOT RUNNING

SET - REPLACEMENT - FAN

Next: End

INSPECTION SYSTEM PRESSURE AT TEMPERATURE

HOSE DN10 1=500 - EXPANSION VESSEL

Next: End

PRESSURE SYSTEM COLD

SYSTEM PRESSURE (TOO HIGH)

Next: End

PRESSURE SYSTEM COLD

SENSOR - PRESSURE - CH

Next: End

PRESSURE SYSTEM COLD

SENSOR - PRESSURE - CH (BLOCKAGE)

Next: End

FAULT CODE 10 11 12 13 14

Z REDIRECT

Next: End

FAULT CODE 10 11 12 13 14

CABLE - NTC

Next: End

FAULT CODE 20 21 22 23 24

CABLE - NTC

Next: End

FAULT CODE 20 21 22 23 24

Z REDIRECT

Next: End

FAULT CODE 0 - FLOW THERMISTOR

CABLE - NTC

Next: End

FAULT CODE 0

Z REDIRECT

Next: End

FAULT CODE 0 - RETURN THERMISTOR

CABLE - NTC

Next: End

FAULT CODE 8 - NOT RUNNING

SET - REPLACEMENT - FAN

Next: End

FAULT CODE 8 - IGNORING FAN HALL

PCB - CONTROL

Next: End

FAULT CODE 8 - HALL SENSOR

SET - REPLACEMENT - FAN

Next: End

FAULT CODE 29 30

Z REDIRECT

Next: End

FAULT CODE 2 - FLOW THERMISTOR

CABLE - NTC

Next: End

FAULT CODE 2 - RETURN THERMISTOR

CABLE - NTC

Next: End

FAULT CODE 2

Z REDIRECT

Next: End

FAULT CODE 1 - FLOW THERMISTOR

CABLE - NTC

Next: End

FAULT CODE 1 - RETURN THERMISTOR

CABLE - NTC

Next: End

OPERATION CH - DISPLAY REMAINS ON 1

PCB - CONTROL

Next: End

OBSERVATIO CH MODULATION

PCB - CONTROL

Next: End

OBSERVATION DISPLAY OPERATES AND SELF CHECK

SET - REPLACEMENT - FAN

Next: End

OPERATION DHW - DHW COOL RADS COOL

HEAT EXCHANGER (WATERWAYS)

Next: End

FUSE INVESTIGATION

NO FAULT FUSE INVESTIGATION

Next: End

OPERATION CH - DOES NOT REACH TEMP

PCB - CONTROL

Next: End

OBSERVATION BOILER RUNS FOR DHW - BLANK

FLOW SENSOR - SIKA

Next: End

OBSERVATION BOILER RUNS FOR DHW - 1

PCB - CONTROL

Next: End

OBSERVATION DHW FLOW RATE

HEAT EXCHANGER (FLOW RATE)

Next: End

BURNER IGNITES BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p105

BURNER IGNITES BUT BAFFLES OUT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p124

DHW COOL, PUMP RUNS AND RADIATORS HEAT

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p148

DHW TOO HOT

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p150

HEAT EXCHANGER NOISY (KETTLES) DURING OPERATION

CHARACTERISTIC TEST FROM OPERATION DHW

Next: !p154

DHW COOL, RADIATORS COOL

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p491

RADIATORS HEAT BUT HEAT EXCHANGER NOISY (KETTLES)

CHARACTERISTIC TEST FROM OPERATION CH

Next: p190

BOILER REACHES TEMPERATURE BUT RADIATORS NOT HEATING

CHARACTERISTIC TEST FROM OPERATION CH

Next: p198

BOILER AND RADIATORS DO NOT REACH TEMPERATURE

CHARACTERISTIC TEST FROM OPERATION CH

Next: p209

DISPLAY FLASHING SHOWING LOW PRESSURE

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK

Next: p241

24V CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION TYPE OF EXTERNAL CONTROLS

Next: p270

OPENTHERM CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION TYPE OF EXTERNAL CONTROLS

Next: p272

BOILER SHOWS FAULT CODE

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK

Next: p29

BOILER DOES NOT SHOW PRESSURE

CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD

Next: p294

PRESSURE DOES NOT CHANGE WHEN WATER ADDED TO SYSTEM

CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD

Next: p296

SYSTEM PRESSURE TOO HIGH

CHARACTERISTIC TEST FROM PRESSURE SYSTEM COLD

Next: !p298

DISPLAY DOES NOT OPERATE

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK

Next: p31

BURNER DOES NOT IGNITE - DISPLAY REMAINS ON 1

CHARACTERISTIC TEST FROM OPERATION CH

Next: p388

BOILER FIRES WITH NO DEMAND

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES AND SELF CHECK

Next: p41

DISPLAY REMAINS BLANK (AFTER SELF CHECK)

CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW

Next: p43

DISPLAY REMAINS ON 1

CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW

Next: p45

DISPLAY REMAINS ON 3 (MAY GO TO LOCKOUT CODE 8)

CHARACTERISTIC TEST FROM OBSERVATION BOILER RUNS FOR DHW

Next: p47

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES

Next: p74

INLET PRESSURE DOES NOT DROP DURING SPARKING

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: p79

INLET PRESSURE DIES AWAY DURING SPARKING

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: !p81

INSPECTION FLUE

Next: p428, !f114

RESISTANCE FLOW THERMISTOR (S1) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p315, f316

INSPECTION INJECTOR

UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR

Next: p144, !f438

RESISTANCE DHW THERMISTOR AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: !p159, !f160

OBSERVATION TYPE OF EXTERNAL CONTROLS

{GAINPCBACS}

Next: p268, ?269, ?271

VOLTAGE PUMP (AC)

{GAINPCBACS}

Next: !p182, !f181

RESISTANCE PUMP

DISCONNECT X2 FROM THE PCB

Next: p406, !f305

OBSERVATION BOILER RESET

Next: !p353, !f354

RESISTANCE MAINS FUSE

REMOVE FUSE FROM FUSED SPUR

Next: !p234, f231

FUSE FURTHER INVESTIGATION

Next: !p232, !f233

FUSE FURTHER INVESTIGATION

Next: !p238, !f239

VOLTAGE PRESSURE SENSOR (PRESSURE)

{GAINPCBACS}

Next: !p244, !f246

OBSERVATION DISCONNECT X4

DISCONNECT X4 FROM THE PCB AND MAKE SAFE

Next: !p252, !f253

RESISTANCE HARNESS FAN

DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB

Next: !p263, !f264

PRESSURE EXPANSION VESSEL

DRAIN BOILERS HEATING CIRCUIT

Next: !p290, !f291

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p319, !f320

RESISTANCE RETURN THERMISTOR (S2) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p322, f323

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: !p324, !f325

RESISTANCE FLOW THERMISTOR (S1) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p335, f330

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p331, !f332

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: !p340, !f341

OBSERVATION FAN RUNS FOR DHW

Next: p343, f344

VOLTAGE FAN DEMAND

{GAINPCBACS}
DISCONNECT PLUG FROM FAN AND MAKE SAFE

Next: p345, !f346

RESISTANCE HARNESS FAN

DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB

Next: !p351, !f352

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p362, !f363

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: !p366, !f367

RESISTANCE FLOW THERMISTOR (S1) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p371, f372

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p373, !f374

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: !p377, !f378

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p398, !f399

OBSERVATION DISCONNECT FAN

DISCONNECT PLUG FROM FAN
RECONNECT X3 AT THE PCB IF YOU HAVE NOT ALREADY DONE SO

Next: !p404, !f405

OBSERVATION IS BOILER IN FROST PROTECTION

NO DEMANDS

Next: p486, f223

RESISTANCE DHW THERMISTOR

DISCONNECT CONNECTOR TO DHW THERMISTOR (REQUIRES FLUE PIPE & SUMP / CONDENSATE REMOVAL)

Next: !p54, !f55

OBSERVATION WATER SUPPLY

Next: p61, !f69

VOLTAGE FAN DEMAND

{GAINPCBACS}
DISCONNECT PLUG FROM FAN AND MAKE SAFE

Next: p265, !f259

RESISTANCE GAS VALVE

DISCONNECT PLUG FROM GAS VALVE

Next: !p83, !f84

VOLTAGE SPARK GENERATOR

{GAINPCBACS}

Next: !p91, !f92

INSPECTION FLUE

Next: p418, !f101

INSPECTION FLUEWAYS

REMOVE GAS / FAN / BURNER ASSEMBLY

Next: !p138, !f103

INSPECTION CONDENSATE

Next: p107, !f106

PRESSURE GAS INLET

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p110, !f108

PRESSURE FAN

ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE

Next: p111, f112

RESISTANCE IGNITION / RECTIFICATION LEAD

DISCONNECT RECTIFICATION LEAD FROM SPARK ELECTRODE AND IGNITION MODULE

Next: p118, !f117

INSPECTION FLUEWAYS

REMOVE GAS / FAN / BURNER ASSEMBLY

Next: !p141, !f116

RESISTANCE IGNITION MODULE RECTIFICATION

DISCONNECT X1 FROM THE PCB
DISCONNECT SPARK / RECTIFICATION LEAD FROM THE IGNITION MODULE

Next: p120, !f119

INSPECTION ELECTRODE

REMOVE IGNITION / RE

Next: !p122, !f121

INSPECTION CONDENSATE

Next: p126, !f125

PRESSURE GAS INLET

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p131, !f127

PRESSURE FAN

ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE

Next: !p129, f130

INSPECTION FLUE

Next: p128, !f135

INSPECTION FLUEWAYS

REMOVE GAS / FAN / BURNER ASSEMBLY

Next: !p145, !f437

RESISTANCE DHW THERMISTOR AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: !p152, !f151

RESISTANCE DHW THERMISTOR AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p166, !f161

PRESSURE GAS INLET (DHW TOO COOL)

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p463, !f171

INSPECTION PUMP

DRAIN BOILER PRIMARY CIRCUIT
REMOVE GAS VALVE

Next: !p192, !f193

INSPECTION PUMP

DRAIN BOILER PRIMARY CIRCUIT
REMOVE GAS VALVE

Next: !p395, !f206

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: p215, !f210

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: p532, !f217

OBSERVATION ISOLATE DHW

TURN DHW ISOLATION V

Next: !p225, !f224

RESISTANCE PCB FUSE

REMOVE FUSE FROM HOLDER ON THE PCB

Next: p401, f237

OBSERVATION REFILL SYSTEM

Next: !p242, f243

RESISTANCE HARNESS FAN

DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB

Next: !p266, !f267

OBSERVATION LINK 24V CONTROLS

REMOVE 24V CONTROL C

Next: !p279, !f280

OBSERVATION LINK OPENTHERM CONTROLS

REMOVE OPENTHERM CON

Next: !p277, !f278

FAULT CODES

Next: !p228, !f229

VOLTAGE PRESSURE SENSOR (PERMANENT)

{GAINPCBACS}

Next: p299, !f300

VOLTAGE PRESSURE SENSOR (PRESSURE)

{GAINPCBACS}

Next: !p303, !f304

RESISTANCE HARNESS PRESSURE SENSOR

DISCONNECT PLUG FROM WATER PRESSURE SENSOR
DISCONNECT X7 FROM THE PCB

Next: !p301, !f302

VOLTAGE MAINS AT PCB

{GAINPCBACS}

Next: p235, f230

OBSERVATION BOILER RESET

Next: !p317, !f318

OBSERVATION BOILER RESET

Next: !p326, !f327

OBSERVATION BOILER RESET

Next: !p333, !f334

RESISTANCE RETURN THERMISTOR (S2) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p329, f339

VOLTAGE FAN HALL SENSOR

{GAINPCBACS}

Next: !p349, f350

RESISTANCE HARNESS FAN

DISCONNECT PLUG FROM THE FAN
DISCONNECT X3 FROM THE PCB

Next: !p347, !f348

RESISTANCE FLOW THERMISTOR (S1) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p360, f361

RESISTANCE RETURN THERMISTOR (S2) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p364, f365

OBSERVATION BOILER RESET

Next: !p368, !f369

RESISTANCE RETURN THERMISTOR (S2) AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: p375, f376

OBSERVATION BOILER RESET (1)

ENSURE BOILER IS COOL

Next: !p382, !f400

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: p389, !f390

RESISTANCE RETURN THERMISTOR (S2)

DISCONNECT INLINE CONNECTOR TO RETURN THERMISTOR

Next: !p391, !f392

OBSERVATION DISCONNECT X3

DISCONNECT X3 FROM THE PCB

Next: !p402, f403

RESISTANCE GAS VALVE

DISCONNECT PLUG FROM GAS VALVE

Next: p407, !f408

DIODE TEST GAS VALVE HARNESS

REMOVE THE CONNECTOR

Next: p519, !f410

RESISTANCE IGNITION / RECTIFICATION LEAD

DISCONNECT RECTIFICATION LEAD FROM SPARK ELECTRODE AND IGNITION MODULE

Next: p97, !f415

INSPECTION INJECTOR

UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR

Next: p100, !f426

INSPECTION INJECTOR

UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR

Next: p113, !f434

VOLTAGE DHW FLOW SENSOR (DEMAND)

{GAINPCBACS}

Next: p51, f48

RESISTANCE DHW THERMISTOR AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: !p63, !f64

INSPECTION FLUE

Next: p464, !f465

INSPECTION INJECTOR

UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR

Next: p466, !f467

INSPECTION FLUEWAYS

REMOVE GAS / FAN / BURNER ASSEMBLY

Next: p470, !f469

INSPECTION BURNER

REMOVE FAN / GAS VALVE / BURNER ASSEMBLY

Next: !p471, !f472

RESISTANCE FLOW THERMISTOR (S1)

DISCONNECT INLINE CONNECTOR TO FLOW THERMISTOR

Next: !p484, !f485

TEMPERATURE AMBIENT

Next: p483, !f490

TEMPERATURE DIFFERENCE BOILER TO TAP (MIXER PASSING)

ATTACH TEMPERATURE CLAMP TO DHW OUTLET PIPE UNDERNEATH BOILER (SEE PICTURE)

Next: p156, !f505

RESISTANCE HARNESS DHW FLOW SENSOR

DISCONNECT PLUG FROM FLOW SENSOR
DISCONNECT X7 FROM THE PCB

Next: !p57, !f58

INSPECTION EXTERNAL BYPASS

Next: p522, !f510

RESISTANCE DHW THERMISTOR AND HARNESS

DISCONNECT X7 FROM THE PCB

Next: !p52, f53

INSPECTION EXTERNAL BYPASS

Next: p527, !f515

INSPECTION INJECTOR

UNDO TOP NUT OF GAS VALVE AND REMOVE INJECTOR

Next: !p517, !f518

RESISTANCE HARNESS GAS VALVE TO EARTH

DISCONNECT X1 FROM THE PCB

Next: !p520, !f521

INSPECTION PARAMETERS 3 AND 3.

NO DEMANDS

Next: p191, !f526

INSPECTION PARAMETERS 3 AND 3.

NO DEMANDS

Next: p199, !f531

INSPECTION PARAMETERS 3 AND 3.

NO DEMANDS

Next: !p533, !f534

INSPECTION ISOLATION VALVES CH

Next: p511, !f543

INSPECTION DHW FLOW SENSOR

DRAIN BOILER DHW CIR

Next: !p71, !f72

VOLTAGE FAN HALL SENSOR

{GAINPCBACS}

Next: !p256, f262

INSPECTION CONDENSATE

Next: p76, !f75

PRESSURE GAS INLET AND DROP

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p77, ?78, ?80

OBSERVATION SPARKING AT GENERATOR

REMOVE IGNITION LEAD

Next: p95, f90

VOLTAGE GAS VALVE

{GAINPCBACS}

Next: p85, f82

INSPECTION FLUE

Next: p87, !f86

DIODE TEST GAS VALVE HARNESS

REMOVE THE CONNECTOR

Next: p516, !f89

PRESSURE FAN

ATTACH U-GAUGE TO OUT TEST POINT ON THE GAS VALVE

Next: p411, f96

INSPECTION ELECTRODE

REMOVE IGNITION / RE

Next: !p99, !f98

System Information

  • Total Tests: 359
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control