Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Disconnect plug from fan and make safe
Disconnect plug from fan and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure the voltage between pin 2 of X3 on the PCB to a suitable earth point.
Voltage should be approximately 28V DC.
Test 2:
Measure the voltage between pin 4 of X3 on the PCB to a suitable earth point.
Voltage should be approximately 28V DC.
Note:
Appliance may enter lockout during test, reset as necessary until test is complete.
Measure the voltage between pin 2 of X3 on the PCB to a suitable earth point.
Voltage should be approximately 28V DC.
Test 2:
Measure the voltage between pin 4 of X3 on the PCB to a suitable earth point.
Voltage should be approximately 28V DC.
Note:
Appliance may enter lockout during test, reset as necessary until test is complete.

Isolate as per TOPs P4
and refit as necessary