Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
VOKERA EXCELL 80SP
WARNING - IMPORTA
EXCESSIVE SYSTEM PRESSURE RISE
MODE SELECTOR SWITCH TO C/H POSITION.
CENTRAL HEATING THERMOSTAT TO MAXIMUM.
CENTRAL HEATING
MODE SELECTOR SWITCH TO C/H POSITION.
CENTRAL HEATING THERMOSTAT TO MAXIMUM.
HOT WATER
MODE SELECTOR SWITCH TO DHW POSITION.
DHW STAT TO MAX.
C/H MODULATION
MODE SELECTOR SWITCH
C/H BURNER IGNITES
SET THE MODE SELECTOR SWITCH TO C/H POSITION.
C/H FAN RUNS (HIGH SPEED)
SET THE MODE SELECTOR SWITCH TO C/H POSITION.
DHW MODULATION
MODE SELECTOR SWITCH
DHW BURNER IGNITES
MODE SELECTOR SWITCH TO DHW POSITION
DHW FAN RUNS (HIGH SPEED)
SET THE MODE SELECTOR SWITCH TO DHW POSITION.
DHW DEMAND
MODE SELECTOR SWITCH IN OFF POSITION.
PILOT FLAME FAILURE
SWITCH OFF GAS SUPPLY
VOKERA EXCELL 80SP
G.C. NUMBER 47 094 1
ELECTRICAL SAFETY CHECKS
ELECTRICAL CHECKS
EXCESSIVE SYSTEM PRESSURE RISE
EXPANSION VESSEL
PILOT IGNITES
PILOT INJECTOR
SPLIT OR WORN
BOILER FLOW SWITCH DIAPHRAGM
ELECTRODE SPARKING
EARTH LEAD
ELECTRODE SPARKING
SPARK ELECTRODE LEAD
DHW MODULATION
THERMISTOR
DHW MODULATION
ELECTRONIC CONTROL BOX (PCB)
MAX ONLY
MODULATION COIL
NO POWER TO MODUREG
ELECTRONIC CONTROL BOX (PCB)
PILOT ESTABLISHED
THERMOCOUPLE
DHW MODULATION 1
THERMISTOR
DHW MODULATION
MODULATION COIL
PILOT FLAME FAILURE
THERMO ELECTRIC VALVE
SLOW FAN
2A FUSE.
SLOW FAN
MAINS POWER - 240V AC SUPPLY
2A FUSE (PCB)
ELECTRONIC CONTROL BOX (PCB)
SLOW FAN
FAN (SLOW SPEED) 560 OHM RESISTOR
DHW DEMAND
DHW THROTTLE
DHW DEMAND
DHW DIAPHRAGM
DHW FAN RUNS (HIGH SPEED)
DHW MICROSWITCH
WATER PUMP RUNNING
ELECTRONIC CONTROL BOX (PCB)
DHW FAN RUNS (HIGH SPEED)
BOILER FLOW MICROSWITCH
DHW FAN RUNS (HIGH SPEED)
THERMISTOR
DHW FAN RUNS (HIGH SPEED)
BOILER FLOW SWITCH DIAPHRAGM
DHW BURNER IGNITES
AIR PRESSURE SWITCH TUBES
DHW BURNER IGNITES
FLUE
DHW BURNER IGNITES
FLUE VENTURIS
DHW BURNER IGNITES
ELECTRONIC CONTROL BOX (PCB)
DHW BURNER IGNITES
GAS VALVE SOLENOID
CH FAN RUNS (HIGH SPEED)
ELECTRONIC CONTROL BOX (PCB)
CH BURNER IGNITES
ELECTRONIC CONTROL BOX (PCB)
CH MODULATION
ELECTRONIC CONTROL BOX (PCB)
CENTRAL HEATING
EARTH LEAD
DHW FAN RUNS (HIGH SPEED)
BOILER FLOW SWITCH VENTURI
STUCK
BOILER FLOW MICROSWITCH
PILOT IGNITES
THERMO ELECTRIC VALVE
RESTRICTED OR BLOKED
BOILER FLOW SWITCH VENTURI
ELECTRODE SPARKING
SPARK ELECTRODE
ELECTRODE SPARKING
PIEZO IGNITER
MAX RATE ONLY
GAS VALVE ASSEMBLY
PILOT ESTABLISHED
HIGH LIMIT THERMOSTAT
PILOT ESTABLISHED
THERMO ELECTRIC VALVE
DHW MODULATION
GAS VALVE ASSEMBLY
SLOW FAN
FAN
SLOW FAN RESISTOR
ELECTRONIC CONTROL BOX (PCB)
DHW DEMAND
DHW FILTER
DHW DEMAND
DHW VENTURI
DHW FAN RUNS (HIGH SPEED)
AIR PRESSURE SWITCH
AIR PRESSURE DIFFERENTIAL SWITCH: NO AIR
ELECTRONIC CONTROL BOX (PCB)
DHW BURNER IGNITES
AIR PRESSURE SWITCH
DHW BURNER IGNITES
BURNER INJECTORS
DHW BURNER IGNITES
GAS VALVE ASSEMBLY
CH FAN RUNS (HIGH SPEED)
ROOM THERMOSTAT LINK
DHW QUIET OPERATION, COLD RADIATORS
SECONDARY HEAT EXCHANGER
HOT WATER
DIVERTER VALVE
CENTRAL HEATING
SECONDARY HEAT EXCHANGER
HOT WATER
PRIMARY HEAT EXCHANGER
CH NOISY OPERATION, DHW PREVIOUSLY OK
SECONDARY HEAT EXCHANGER
CH QUIET OPERATION, DHW PREVIOUSLY OK
SECONDARY HEAT EXCHANGER
CH NOISY OPERATION, DHW PREVIOUSLY OK
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH QUIET OPERATION, DHW PREVIOUSLY OK
CHARACTERISTIC TEST FROM CENTRAL HEATING
LIGHTS ON MAX BUT DOESNT MODULATE
CHARACTERISTIC TEST FROM DHW MODULATION
DOESNT LIGHT ON MAX
CHARACTERISTIC TEST FROM DHW MODULATION
DHW NOISY OPERATION
CHARACTERISTIC TEST FROM HOT WATER
DHW QUIET OPERATION, COLD RADIATORS
CHARACTERISTIC TEST FROM HOT WATER
DHW QUIET OPERATION, WARM RADIATORS
CHARACTERISTIC TEST FROM HOT WATER
CH NOISY OPERATION DHW PREVIOUSLY NOISY
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH NOISY OPERATION, DHW PREVIOUSLY OK
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH QUIET OPERATION,DHW PREVIOUSLY OK
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH NOISY OPERATION, DHW PREVIOUSLY NOISY
CHARACTERISTIC TEST FROM CENTRAL HEATING
03/01/2018 14:20:41 1712_1_50_1 31/01/2018 09:56:42
09/01/2018 09:29:58
SPARK ELECTRODE LEAD
REMOVE SPARK ELECTRODE LEAD FROM SPARK ELECTRODE.
BOILER FLOW MICROSWITCH (NORMALLY CLOSED)
MODE SELECTOR SWITCH DHW POSITION.
SLOW FAN RESISTOR
DISCONNECT RESISTOR FLYING LEADS AT ADJACENT PLUG
BOILER FLOW SWITCH OPERATION
MODE SELECTOR SWITCH TO DHW POSITION.
WATER PUMP RUNNING
MODE SELECTOR SWITCH TO DHW POSITION.
DHW FLOW MICROSWITCH
MODE SELECTOR SWITCH TO DHW POSITION.
BOILER FLOW MICROSWITCH (NORMALLY OPEN)
MODE SELECTOR SWITCH TO DHW POSITION.
THERMISTOR: SHORT CIRCUIT
CAREFULLY DISCONNECT THERMISTOR LEADS
AIR PRESSURE DIFF SWITCH: AIR DETECT
MODE SELECTOR SWITCH TO DHW POSITION.
GV OPERATOR RESISTANCE
REMOVE ONE WIRE FROM MAIN GAS VALVE OPERATOR SOLENOID
C/H DEMAND VOLTAGE (IN)
MODE SELECTOR SWITCH TO C/H POSITION
THERMISTOR RESISTANCE
CAREFULLY UNPLUG THE LEADS FROM THE THERMISTOR
DHW MODULATION VOLTAGE
MODE SELECTOR SWITCH
VOLTAGE IGNITION RATE DHW
MODE SELECTOR SWITCH TO DHW POSITION.
TURN DHW STAT TO MAXIMUM.
THERMISTOR RESISTANCE
CAREFULLY UNPLUG THE LEADS FROM THE THERMISTOR
SLOW FAN VOLTAGE
MODE SELECTOR SWITCH DHW POSITION.
SELECTOR SWITCH ON VOLTAGE
MODE SELECTOR SWITCH TO DHW POSITION.
DHW FLOW SWITCH DIAPHRAGM
DHW WATER OFF AND BOILER DRAINED.
AIR PRESSURE DIFFERENTIAL SWITCH: NO AIR
MODE SELECTOR SWITCH TO DHW POSITION.
WATER PUMP SUPPLY
MODE SELECTOR SWITCH TO DHW POSITION
FAN SUPPLY
MODE SELECTOR SWITCH TO DHW POSITION.
GAS VALVE SUPPLY VOLTAGE
MODE SELECTOR SWITCH TO DHW POSITION.
BURNER PRESSURE
MODE SELECTOR SWITCH TO DHW POSITION
CONNECT 'U' GAUGE TO BURNER PRESSURE TEST POINT
CENTRAL HEATING
MODE SELECTOR SWITCH TO C/H POSITION.
CENTRAL HEATING THERMOSTAT TO MAXIMUM.
System Information
- Total Tests: 135
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control