BAXI ECOBLUE COMBI & ECOBLUE PLUS COMBI
GLOBALLY REPLACED
OBSERVATION PUMP RUNS DHW DEMAND
ENSURE APPLIANCE IS COOL
SET FLOW RATE TO APPROX. 3 LITRES A MINUTE
INFORMATION RESETTING APPLIANCE
THIS APPLIANCE HAS F
E85 EXTERNAL CONTROLS
NOT USED HEADER FOR FAULT CODE
FAN NOT RUNNING
THERMOSTAT 105 DEG C - LIMIT
E40
HARNESS - LOW VOLTAGE
E20
SENSOR - THERMODISC - MINIFIT (FLOW)
FAULT E110 E111 - OPEN CIRCUIT
THERMOSTAT 105 DEG C - LIMIT
E130
HEAT EXCHANGER ASSEMBLY
E130
HARNESS - WIRING - NTC
FAN NOT RUNNING - FLUE STAT
HARNESS - WIRING - NTC
FLUE SENSOR TRIGGER
FLUE
E321
HARNESS - LOW VOLTAGE
NOT STOP SPARKING
CONDENSATE TRAP ASSEMBLY
CASE REMOVAL
Z REDIRECT
E109 E125
HARNESS - WIRING - HIGH VOLTAGE
E109 E125 HEATING
HARNESS - WIRING - HIGH VOLTAGE
E109 E125 HEATING CAL
SENSOR - THERMODISC - MINIFIT (FLOW)
E109 E125 BOTH DEMANDS
HARNESS - WIRING - HIGH VOLTAGE
DHW TOO HOT
SENSOR - THERMODISC - MINIFIT (FLOW)
DHW TOO HOT
SENSOR - NTC - DHW
E109 E125 BOTH DEMANDS
SENSOR - THERMODISC - MINIFIT (FLOW)
E109 E125
SENSOR - THERMODISC - MINIFIT (FLOW)
E110 E111
SENSOR - THERMODISC - MINIFIT (RETURN)
E110 E111
SENSOR - THERMODISC - MINIFIT (FLOW)
FUSE INVESTIGATION
HEAD - MOTOR - 3 WAY VALVE
FUSE INVESTIGATION - NO CLOCK
HARNESS - POWER SUPPLY
FUSE INVESTIGATION
PUMP
FUSE INVESTIGATION
IGNITER ASSEMBLY
FUSE INVESTIGATION
GAS VALVE
FUSE INVESTIGATION
INTERNAL TIMER
OBSERVATION SPARKING OCCURS
SENSOR - THERMODISC - MINIFIT (FLOW)
OBSERVATION SPARKING OCCURS
SENSOR - NTC - DHW
NO SPARK SEEN
HARNESS - WIRING - HIGH VOLTAGE
NO SPARK SEEN
CABLE - IGNITION ELECTRODE
NO SPARK SEEN
LEAD - EARTH - IGNITOR
NO SPARK SEEN
ELECTRODE - SPARK
NO HOT WATER - GAS VALVE SHORT
PCB MAIN AND GAS VALVE
DOES NOT LIGHT - SOLENOID DAMAGED
GAS VALVE
DOES NOT LIGHT
AIRBOX
NO IGNITION RESTRICTED
INJECTOR
NOT LIGHTING
ELECTRODE - SPARK
BAFFLES OUT
CONDENSATE TRAP ASSEMBLY
BAFFLES OUT
GAS SUPPLY
BAFFLES OUT - AIR IN
FLUE
BAFFLES OUT
AIRBOX
NO IGNITION
CONDENSATE TRAP ASSEMBLY
SPARKING DOES NOT STOP
GAS SUPPLY
BAFFLES OUT
HEAT EXCHANGER ASSEMBLY
BAFFLES OUT
BURNER
BAFFLES OUT
FLUE
BAFFLES OUT PRESSURE OK
BURNER
FOR TYPE DIAG PROCEDURE
Z REDIRECT
FAULT E28
HARNESS - WIRING - NTC
FAULT E28
THERMOSTAT 105 DEG C - LIMIT
E117 E118
HARNESS - LOW VOLTAGE
FAULT CODE 384
FLUE
FAULT E384
CONDENSATE TRAP ASSEMBLY
FAULT CODE 384 PASSING
GAS VALVE
FAULT E160FAN NOT RUNNING
HARNESS - LOW VOLTAGE
FAULT E160FAN NOT RUNNING
HARNESS - WIRING - HIGH VOLTAGE
CH NOISY
AIRBOX
CH NOISY
CONDENSATE TRAP ASSEMBLY
CH NOISY
BURNER
CH NOISY - GAS RATE
HEAT EXCHANGER ASSEMBLY
CH NOISY
SENSOR - THERMODISC - MINIFIT (FLOW)
CH NOISY
SENSOR - THERMODISC - MINIFIT (RETURN)
DIVERTER VALVE RADS COOL BOILER WARM
HARNESS - WIRING - HIGH VOLTAGE
CH RADS COOL BOILER AT TEMP
CARTRIDGE - 3 WAY VALVE
CH RADS COOL BOILER AT TEMP
VALVE - RETURN / VALVE - CENTRAL HEATING
CH RADS COOL BOILER AT TEMP
CARTRIDGE - BYPASS
CH RADS COOL BOILER AT TEMP
FILTER - CH
PRESSURE RISE ON HEATING
EXPANSION VESSEL
CH SHUTS DOWN EARLY
SENSOR - THERMODISC - MINIFIT (FLOW)
CH SHUTS DOWN EARLY
SENSOR - THERMODISC - MINIFIT (RETURN)
PUMP OVERRUN
PCB
NO SPARKING
HARNESS - LOW VOLTAGE
FAULT E160 FAN RUNNING
HARNESS - LOW VOLTAGE
NOT STOP SPARKING - FLAME SENSE LEAD SHORTING
HARNESS - LOW VOLTAGE
FAULT 151
PCB WATER INGRESS
FAULT E151
PCB
FAULT E386
HARNESS - LOW VOLTAGE
FAULT E110 E111
HEAT EXCHANGER ASSEMBLY
FAULT E321
PCB
FAULT E386
PCB
FAULT E40
PCB
FAULT E28
PCB
FAULT E20
PCB
NO HEATING - NO CLOCK
CONNECTOR - TIMER BRIDGE
PUMP RUNS CONTINUOUSLY
SENSOR - THERMODISC - MINIFIT (FLOW)
NO DISPLAY
MAINS FUSE
BLANK DISPLAY
FUSE 2A 250V WITH HOLDER
BLANK DISPLAY
HARNESS - POWER SUPPLY
NO DISPLAY
PCB
NO DISPLAY
HARNESS - WIRING - BOILER CONTROL
FIRING WITH NO DEMAND
AMBIENT TEMP
FIRES WITH NO DEMAND
WATER LEAK OR OPEN TAP
FIRING WITH NO DEMAND
SENSOR - THERMODISC - MINIFIT (FLOW)
FAN RUNS CONT AT POWER UP
HARNESS - LOW VOLTAGE
FAN RUNS CONT
PCB
WATER COOL READS COOL
CONDENSATE TRAP ASSEMBLY
WATER COOL RADS COOL
EXTERNAL MIXING
DHW COOL RADS COOL
PUMP
WATER COOL RADS COOL
SENSOR - THERMODISC - MINIFIT (FLOW)
WATER COOL RADS COOL
SENSOR - NTC - DHW
DHW COOL RADS COOL
SENSOR - NTC - HEAT EXCHANGER
DHW COOL RADS COOL LOW PRESSURE
HEAT EXCHANGER ASSEMBLY
DHW COOL RADS COOL
GAS SUPPLY
DHW NOISY
CONDENSATE TRAP ASSEMBLY
DHW NOISY
AIRBOX
DHW NOISY
BURNER
DHW NOISY - GAS RATE
HEAT EXCHANGER ASSEMBLY
NOISY OPERATION DHW
PUMP
DHW RUNS HOT COLD
HEAT EXCHANGER ASSEMBLY
FUSE INVESTIGATIONRESISTANCE OK
HEAD - MOTOR - 3 WAY VALVE
FAN RUNS CONTINUALLY
HARNESS - LOW VOLTAGE
E109 E125 PUMP
HARNESS - WIRING - HIGH VOLTAGE
E109 E125
HEAT EXCHANGER - PLATE TO PLATE
E109 E125 BOTH DEMANDS PUMP
HARNESS - WIRING - HIGH VOLTAGE
E109 E125 BOTH DEMANDS
HEAT EXCHANGER ASSEMBLY
E110 E111
HARNESS - LOW VOLTAGE
INFO BOILER RESET
Z REDIRECT
E110 E111
FILTER - CH
FAULT E110 E111
PUMP
CH NOISY
PUMP
CH NOISY
FILTER - CH
E110 E110 STUCK IN FAULT
SENSOR - THERMODISC - MINIFIT (FLOW)
E110 E111 STUCK IN FAULT
SENSOR - THERMODISC - MINIFIT (RETURN)
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY
NO IGNITION BLOCKED
INJECTOR
DOES NOT LIGHT
BURNER
DOES NOT LIGHT
HEAT EXCHANGER ASSEMBLY
DOES NOT LIGHT LOW PRESSURE
AIRBOX
NO HOT WATER
MAINS WATER SUPPLY
POOR FLOW RATE
VALVE - COMPACT - RETURN - DHW
POOR FLOW RATE
CARTRIDGE - 12L FLOW RATE - DHW
NO HOT WATER
CARTRIDGE - 12L FLOW RATE - DHW
DHW HALL SENSOR
HARNESS - LOW VOLTAGE
NO HOT WATER
SENSOR - NTC - DHW
RETURN - NO HOT WATER
HARNESS - LOW VOLTAGE
PUMP NOT RUNNING HW
HARNESS - WIRING - HIGH VOLTAGE
E160 FAN RUNS HALL SENSOR VOLTAGE PRESENT
HARNESS - LOW VOLTAGE
OBSERVATION PUMP RUNS
EXTERNAL MIXING
FIRING WITHOUT DEMAND
SENSOR - NTC - DHW
FAULT E83
HARNESS - LOW VOLTAGE
FAULT E83
PCB
FAULT E83 EBUS / LOW VOLTAGE FITTED
HARNESS - LOW VOLTAGE
E85
PCB
LOW VOLTAGE OR EBUS CONTROLSFIRES WITH NO DEMAND
WATER LEAK OR OPEN TAP
LOW VOLTAGE OR EBUS CONTROLSFIRING WITH NO DEMAND
SENSOR - THERMODISC - MINIFIT (FLOW)
LOW VOLTAGE OR EBUS CONTROLSFIRING WITHOUT DEMAND
SENSOR - NTC - DHW
FIRING WITH NO DEMAND
LOW VOLTAGE / EBUS CONTROLS
E83 FAULT CODE
LOW VOLTAGE / EBUS CONTROLS
E85 FAULT CODE
LOW VOLTAGE / EBUS CONTROLS
NOT RESPONDING TO CH
LOW VOLTAGE / EBUS CONTROLS
NOT STOP SPARKING
ELECTRODE - FLAME SENSING
NOT STOP SPARKING
HARNESS - LOW VOLTAGE
ALT DIFFERENTIAL TEST 2
Z REDIRECT
DIVERTER VALVE WATER COOL RADS COOL
HARNESS - WIRING - HIGH VOLTAGE
FAULT CODES
Z REDIRECT
FAN NOT RUNNING
HARNESS - LOW VOLTAGE
FAN NOT RUNNING
HARNESS - WIRING - HIGH VOLTAGE
FAN NOT RUNNING - FLUE SENSOR
HARNESS - LOW VOLTAGE
TO OVERHEAT
HARNESS - WIRING - HIGH VOLTAGE
E40
SENSOR - THERMODISC - MINIFIT (RETURN)
E20
HARNESS - LOW VOLTAGE
E110 E111
HARNESS - WIRING - HIGH VOLTAGE
E130
PCB
E130
HARNESS - LOW VOLTAGE
E130
SENSOR - NTC - HEAT EXCHANGER
FAN NOT RUNNING
SENSOR - NTC - HEAT EXCHANGER
E321
SENSOR - NTC - DHW
DHW TEMPERATURE SETTING
CUSTOMER ACTION
OBSERVATION PUMP RUNS DHW DEMAND
PCB HMI - BOILER CONTROL
E109 E125
HEAD - MOTOR - 3 WAY VALVE
E109 E125 HEATING
HEAD - MOTOR - 3 WAY VALVE
E109 E125 BOTH DEMANDS
HEAD - MOTOR - 3 WAY VALVE
FUSE INVESTIGATION - DIVERTER
HARNESS - WIRING - HIGH VOLTAGE
FUSE INVESTIGATION - PUMP
HARNESS - WIRING - HIGH VOLTAGE
FUSE INVESTIGATION - NO FAULT FOUND
NO FAULT - FUSE INVESTIGATION
FUSE INVESTIGATION - SPARK GENERATOR
HARNESS - WIRING - HIGH VOLTAGE
FUSE INVESTIGATION - GAS VALVE
HARNESS - WIRING - HIGH VOLTAGE
FUSE INVESTIGATION - FAN
HARNESS - WIRING - HIGH VOLTAGE
FUSE INVESTIGATION - CLOCK
HARNESS - POWER SUPPLY
OBSERVATION SPARKING OCCURS - NO SPARK WITHOUT LEADS
IGNITER ASSEMBLY
NO SPARK SEEN
IGNITER ASSEMBLY
DOES NOT LIGHT
GAS SUPPLY
BOILER DOES NOT LIGHT
PCB AND HARNESS - WIRING - HIGH VOLTAGE
NO IGNITION NOT OPENING
GAS VALVE
NOT LIGHTING - GAS VALVE
HARNESS - WIRING - HIGH VOLTAGE
DOES NOT LIGHT
FAN
DOES NOT LIGHT
VENTURI
NO IGNITION NOT OPENING FULLY
GAS VALVE
BAFFLES OUT
FAN
BAFFLES OUT
VENTURI
BAFFLES OUT
GAS VALVE
FAULT E28
HARNESS - LOW VOLTAGE
FAULT E28
SENSOR - NTC - HEAT EXCHANGER
FAULT E28
HARNESS - WIRING - HIGH VOLTAGE
E117 E118
PCB
FAULT E384
PCB
CH NOISY
GAS VALVE
CH NOISY
FAN
CH NOISY
VENTURI
CH NOISY
FLUE
CH NOISY
HEAT EXCHANGER ASSEMBLY
RADS COOL BOILER WARM
HEAD - MOTOR - 3 WAY VALVE
PRESSURE RISE ON HEATING
HOSE - EXPANSION VESSEL
CH TEMPERATURE SETTING
CUSTOMER ACTION
OPERATION CH - CH SET TOO LOW
PCB HMI - BOILER CONTROL
CH TURNED OFF
CUSTOMER ACTION
BOILER RESPONDS TO CH - TURNED OFF
PCB HMI - BOILER CONTROL
NO SPARKING
FAN
NOT STOP SPARKING - SHORTING TO EARTH
ELECTRODE - FLAME SENSING
FAULT CODE E117 E118
HYDRAULIC GROUP ASSEMBLY
FAULT CODE E117 E118 - NOT BLOCKED
SENSOR - PRESSURE
FAULT E386
FAN
FAULT E151
Z REDIRECT
FAULT E110 E111
HEAT EXCHANGER - PLATE TO PLATE
NO FAULT OVERHEAT
OVERHEAT
FAULT E110 E111 - TRIPPING EARLY
THERMOSTAT 105 DEG C - LIMIT
FAULT E321
Z REDIRECT
FAULT E386
Z REDIRECT
FAULT E40
Z REDIRECT
FAULT E28
Z REDIRECT
FAULT E20
Z REDIRECT
NO HEATING - NO COMMON AT TERMINAL STRIP
HARNESS - POWER SUPPLY
NO HEATING - CLOCK - EXT TO PCB
HARNESS - POWER SUPPLY
NO HEATING - CLOCK - CLOCK TO EXT
HARNESS - POWER SUPPLY
NO HEATING - CLOCK - PCB TO CLOCK
HARNESS - POWER SUPPLY
NO HEATING
INTERNAL TIMER
FLOW - PUMP RUNS CONTINOUSLY
HARNESS - LOW VOLTAGE
FUSE INVESTIGATION MAINS
Z REDIRECT
FUSE INVESTIGATION INTERNAL
Z REDIRECT
NO DISPLAY
PCB HMI - BOILER CONTROL
FIRING WITHOUT DEMAND FLOW
HARNESS - LOW VOLTAGE
FAN RUNS CONT
FAN
DHW TOO HOT
PCB
DHW COOL RADS COOL DHW TEMPERATURE SETTING
CUSTOMER ACTION
DHW COOL RADS COOL
PCB HMI - BOILER CONTROL
DHW NOISY
FAN
DHW NOISY
VENTURI
DHW NOISY
FLUE
DHW NOISY
PRESSURE GAUGE
DHW RUNS HOT COLD
SYSTEM PRESSURE
NOISY OPERATION DHW
HEAT EXCHANGER - PLATE TO PLATE
FUSE INVESTIGATION - DIVERTERRESISTANCE OK
HARNESS - WIRING - HIGH VOLTAGE
FAN RUNS CONTINUALLY
SENSOR - PRESSURE
E109 E125 BOTH DEMANDS
HEAT EXCHANGER - PLATE TO PLATE
E019 E125 NO FAULT FOUND
E109 E125 NO FAULT FOUND
E117 E118
PRESSURE GAUGE
FAULT E117 E118
SYSTEM PRESSURE
E110 E111
PRESSURE GAUGE
FAULT E110 E111
SYSTEM PRESSURE
E117 E118
SENSOR - PRESSURE (BLOCKAGE)
WATER COOL RADS COOL
HEAT EXCHANGER - PLATE TO PLATE
POOR FLOW RATE
HEAT EXCHANGER - PLATE TO PLATE
NO HOT WATER
HALL SENSOR ASSEMBLY
NO HOT WATER
HARNESS - LOW VOLTAGE
NO HOT WATER
SENSOR - THERMODISC - MINIFIT (RETURN)
NO HOT WATER
PUMP
FIRING WITHOUT DEMAND DHW
HARNESS - LOW VOLTAGE
FAULT E83
HALL SENSOR ASSEMBLY
FAULT E83
Z REDIRECT
FAULT E83 EBUS / LOW VOLTAGE FITTED
HALL SENSOR ASSEMBLY
FAULT E83 EBUS / LOW VOLTAGE FITTED
Z REDIRECT
BLANK FOR E85
Z REDIRECT
LOW VOLTAGE OR EBUS CONTROLSFIRING WITHOUT DEMAND FLOW
HARNESS - LOW VOLTAGE
LOW VOLTAGE OR EBUS CONTROLSFIRING WITHOUT DEMAND DHW
HARNESS - LOW VOLTAGE
NOT STOP SPARKING
BURNER
ALT DIFFERENTIAL TEST
Z REDIRECT
WATER COOL RADS COOL
HEAD - MOTOR - 3 WAY VALVE
WATER COOL RADS COOL
CARTRIDGE - 3 WAY VALVE
FAN NOT RUNNING
FAN
DHW TURNED OFF OR TEMPERATURE SET TOO LOW - ABLE TO CORRECT
CHARACTERISTIC TEST FROM OBSERVATION DHW SET TEMP
DHW TURNED OFF OR TEMPERATURE SET TOO LOW - WILL NOT ADJUST
CHARACTERISTIC TEST FROM OBSERVATION DHW SET TEMP
OCCURS ON HOT WATER NOT HEATING
CHARACTERISTIC TEST FROM OBSERVATION FAULT OCCURED ON WHICH DEMAND
OCCURS ON HEATING DEMAND NOT HOT WATER
CHARACTERISTIC TEST FROM OBSERVATION FAULT OCCURED ON WHICH DEMAND
SHORT CIRCUIT / LOW RESISTANCE MEASURED ON TEST 2
CHARACTERISTIC TEST FROM RESISTANCE MAINS INTO BOILER
SHORT CIRCUIT / LOW RESISTANCE MEASURED ON TEST 1
CHARACTERISTIC TEST FROM RESISTANCE MAINS INTO BOILER
INLET PRESSURE LOW OR DIES AWAY DURING IGNITION
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
INLET PRESSURE DOES NOT DROP DURING IGNITION
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
FAN DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
VENTURI DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
FAN DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
VENTURI DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
BOILER IS NOISY IN HEATING OPERATION
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
FAN DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
VENTURI DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
BOILER GETS HOT BUT RADIATORS DO NOT
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
SYSTEM PRESSURE RISE IS EXCESSIVE
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
SHUTS DOWN BEFORE BOILER OR RADS GET WARM
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
CH TEMPERATURE SET TOO LOW - ABLE TO CORRECT
CHARACTERISTIC TEST FROM OBSERVATION CH SET TEMP
CH TEMPERATURE SET TOO LOW - WILL NOT ADJUST
CHARACTERISTIC TEST FROM OBSERVATION CH SET TEMP
HEATING TURNED OFF OR TEMPERATURE SET TOO LOW - ABLE TO CORRECT
CHARACTERISTIC TEST FROM RESISTANCE MAINS INTO BOILER
HEATING TURNED OFF OR TEMPERATURE SET TOO LOW - WILL NOT ADJUST
CHARACTERISTIC TEST FROM RESISTANCE MAINS INTO BOILER
SENSOR CLEAR - MANIFOLD BLOCKED
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SENSOR BLOCKAGE
SENSOR AND MANIFOLD CLEAR
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SENSOR BLOCKAGE
BOILER GOES TO OVERHEAT - TEMPERATURE BELOW 82°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMP - DOES OVERHEAT OCCUR
BOILER FLOW TEMPERATURE EXCEEDS 90°C AND BOILER STILL FIRED
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMP - DOES OVERHEAT OCCUR
MAINS VOLTAGE PRESENT ON BLACK WIRE BUT NOT ON BLUE WIRE
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
MAINS VOLTAGE ABSENT ON BOTH WIRES
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
VOLTAGE ABSENT ON TEST 1
CHARACTERISTIC TEST FROM VOLTAGE INTERNAL CLOCK
VOLTAGE NOT PRESENT ON TEST 2 (BUT PRESENT ON TEST 1)
CHARACTERISTIC TEST FROM VOLTAGE INTERNAL CLOCK
FAN RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM OBSERVATION BOILER ENTERS STANDBY MODE
BOILER FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER ENTERS STANDBY MODE
DISPLAY BLANK
CHARACTERISTIC TEST FROM OBSERVATION BOILER ENTERS STANDBY MODE
PUMP RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM OBSERVATION BOILER ENTERS STANDBY MODE
DHW TURNED OFF OR TEMPERATURE SET TOO LOW - ABLE TO CORRECT
CHARACTERISTIC TEST FROM OBSERVATION DHW SET TEMP
DHW TURNED OFF OR TEMPERATURE SET TOO LOW - WILL NOT ADJUST
CHARACTERISTIC TEST FROM OBSERVATION DHW SET TEMP
FAN DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
VENTURI DAMAGED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION FAN AND VENTURI
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE
VOLTAGE NOT AS ABOVE ON TEST 1
CHARACTERISTIC TEST FROM VOLTAGE FLOW TURBINE
VOLTAGE NOT AS ABOVE ON TEST 2 (BUT OK ON TEST 1)
CHARACTERISTIC TEST FROM VOLTAGE FLOW TURBINE
LIGHTS BUT BAFFLES / DROPS OUT OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER LIGHTS AND ESTABLISHES
DOES NOT LIGHT
CHARACTERISTIC TEST FROM OBSERVATION BURNER LIGHTS AND ESTABLISHES
LIGHTS BUT DOES NOT STOP SPARKING
CHARACTERISTIC TEST FROM OBSERVATION BURNER LIGHTS AND ESTABLISHES
DHW IS TOO HOT
CHARACTERISTIC TEST FROM OPERATION HOT WATER
TEMPERATURE RISE TOO LOW RADS COOL
CHARACTERISTIC TEST FROM OPERATION HOT WATER
TEMPERATURE RISE TOO LOW RADS HOT
CHARACTERISTIC TEST FROM OPERATION HOT WATER
BOILER IS NOISY IN DHW OPERATION OR RUNS HOT COLD
CHARACTERISTIC TEST FROM OPERATION HOT WATER
30/05/2019 11:16:55 1905_1_50_1 01/07/2019 10:08:21
26/06/2019 09:29:33
RESISTANCE TEMPERATURE SENSOR FLUE AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE TEMPERATURE SENSOR FLUE SEC HARNESS
DISCONNECT THE INLINE PLUG HALF WAY ALONG THE HARNESS TO THE FLUE SENSOR (NEAR THE SPARK GENERATOR)
RESISTANCE HARNESS FLUE SENSOR UPPER
DISCONNECT THE INLIN
RESISTANCE THERMOSTAT OVERHEAT
DISCONNECT THE TWO BLUE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE TEMPERATURE SENSOR RETURN HARNESS
DISCONNECT THE HARNESS FROM THE RETURN SENSOR
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE OF FLOW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE THERMOSTAT OVERHEAT AND HARNESS
DISCONNECT PLUG X14 FROM THE PCB
RESISTANCE THERMOSTAT OVERHEAT
DISCONNECT THE TWO BLUE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE TEMPERATURE SENSOR FLUE AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE TEMPERATURE SENSOR FLUE SEC HARNESS
DISCONNECT THE INLINE PLUG HALF WAY ALONG THE HARNESS TO THE FLUE SENSOR (NEAR THE SPARK GENERATOR)
RESISTANCE HARNESS FLUE SENSOR UPPER
DISCONNECT THE INLIN
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
RESISTANCE DHW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE DHW SENSOR
VOLTAGE DIVERTER VALVE TO HOT WATER
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE DIVERTER HEATING
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE DIVERTER VALVE TO HOT WATER
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE PUMP FROM PCB
{USEINSMAT}
REMOVE PCB COVER
RESISTANCE MAINS INTO BOILER
REMOVE INTERNAL FUSES FROM THE TERMINAL BLOCK
RESISTANCE DIVERTER VALVE
DISCONNECT CONNECTOR
RESISTANCE HARNESS MAINS IN
DISCONNECT X10 FROM THE PCB
RESISTANCE FAN
DISCONNECT 3 PIN PLUG FROM THE FAN
RESISTANCE PUMP
DISCONNECT PLUG FROM THE PUMP
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE SPARK GENERATOR
DISCONNECT PLUG ON THE SPARK GENERATOR
RESISTANCE CLOCK MOTOR
REMOVE INTEGRAL CLOCK FROM APPLIANCE
OBSERVATION SPARKING HEARD
GAS OFF
DISCONNECT THE IGNITION AND EARTH LEADS FROM THE SPARK GENERATOR
VOLTAGE SPARK GENERATOR
{USEINSMAT}
GAIN ACCESS TO PCB
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
GAIN ACCESS TO THE PCB
DISCONNECT CONNECTOR X14 FROM THE PCB
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
RESISTANCE TEMPERATURE SENSOR FLUE AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE TEMPERATURE SENSOR FLUE SEC HARNESS
DISCONNECT THE INLINE PLUG HALF WAY ALONG THE HARNESS TO THE FLUE SENSOR (NEAR THE SPARK GENERATOR)
RESISTANCE HARNESS FLUE SENSOR UPPER
DISCONNECT THE INLIN
RESISTANCE THERMOSTAT OVERHEAT
DISCONNECT THE TWO BLUE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE HARNESS PRESSURE SENSOR
DISCONNECT THE HARNESS FROM THE PRESSURE SENSOR
VOLTAGE PCB TO FAN (LV)
DISCONNECT AND MAKE SAFE THE 4 WIRE LOW
VOLTAGE CONNECTOR FROM THE FAN
PRESSURE FAN
LOOSEN THE SCREW OF
INSPECTION HEATING FILTER
DRAIN THE BOILERS HEATING CIRCUIT
VOLTAGE DIVERTER HEATING
{USEINSMAT}
GAIN ACCESS TO THE PCB
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
VOLTAGE RECTIFICATION - AC - WITHOUT LEAD
GAIN ACCESS TO THE PCB
DISCONNECT CONNECTOR X1 FROM THE PCB
VOLTAGE SOCKET AND SEE CHECK
GAIN ACCESS TO MAINS TERMINAL BLOCK
RESISTANCE FAN AND HARNESS (LV)
GAIN ACCESS TO PCB
DISCONNECT CONNECTOR X23 FROM THE PCB
INSPECTION HARNESS FAN (LV)
DISCONNECT THE 5 PIN CONNECTOR FROM THE FAN
DISCONNECT CONNECTOR X23 FROM THE PCB
INSPECTION PCB AND CONNECTIONS
GAIN ACCESS TO PCB
VOLTAGE PUMP FROM PCB
{USEINSMAT}
REMOVE PCB COVER
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
VOLTAGE SWITCHED LIVE AT PCB
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE HEATING COMMON AT PCB
{USEINSMAT}
GAIN ACCESS TO THE PCB
INSPECTION OF INTERNAL TIMER BYPASS LINK
REMOVE BLANKING PANEL FROM THE FRONT OF THE BOILER
VOLTAGE HEATING COMMON AT PCB
{USEINSMAT}
GAIN ACCESS TO THE PCB
RESISTANCE OF FLOW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
VOLTAGE MAINS INPUT (INPUT SIDE)
{USEINSMAT}
REMOVE THE PCB COVER
RESISTANCE MAINS FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE OF FLOW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE DHW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE DHW SENSOR
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
RESISTANCE DIVERTER VALVE
DISCONNECT CONNECTOR
OBSERVATION DISCONNECT PRESSURE SENSOR
RECONNECT X22 AT THE PCB
DISCONNECT THE CONNECTOR TO THE PRESSURE SENSOR AND MAKE SAFE
VOLTAGE PUMP FROM PCB
{USEINSMAT}
REMOVE PCB COVER
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
INSPECTION HEATING FILTER
DRAIN THE BOILERS HEATING CIRCUIT
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
VOLTAGE FLOW TURBINE
{USEINSMAT}
ENSURE NO HOT WATER DEMAND
RESISTANCE DHW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE DHW SENSOR
RESISTANCE TEMPERATURE SENSOR RETURN HARNESS
DISCONNECT THE HARNESS FROM THE RETURN SENSOR
INSPECTION FLOW SWITCH HARNESS
DISCONNECT CONNECTOR X22 FROM THE PCB
UNCLIP FLOW SWITCH AND REMOVE CONNECTOR
INSPECTION FLOW SWITCH HARNESS
DISCONNECT CONNECTOR X22 FROM THE PCB
UNCLIP FLOW SWITCH AND REMOVE CONNECTOR
OBSERVATION DISCONNECT LOW VOLTAGE / EBUS CONTROLS
REMOVE THE WIRES FROM TERMINALS 1 & 2 ON M2 AND MAKE SAFE
RESISTANCE OF FLOW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE DHW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE DHW SENSOR
RESISTANCE FLAME DETECTION LEAD
DISCONNECT FLAME DETECTION LEAD FROM THE FLAME DETECTION ELECTRODE
USING THE BOILER INFORMATION DISPLAY
OUTSIDE MODEL
VOLTAGE DIVERTER VALVE TO HOT WATER
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE PCB TO FAN (LV)
DISCONNECT AND MAKE SAFE THE 4 WIRE LOW
VOLTAGE CONNECTOR FROM THE FAN
RESISTANCE THERMOSTAT OVERHEAT AND HARNESS
DISCONNECT PLUG X14 FROM THE PCB
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
OBSERVATION DIVERTER VALVE HEAD OPERATION
{USEINSMAT}
REMOV
OBSERVATION PUMP RUNS DHW DEMAND
ENSURE APPLIANCE IS COOL
SET FLOW RATE TO APPROX. 3 LITRES A MINUTE
RESISTANCE DIVERTER VALVE HARNESS
DISCONNECT THE LEAD FROM THE DIVERTER VALVE MOTOR
OBSERVATION DIVERTER VALVE HEAD OPERATION
{USEINSMAT}
REMOV
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
RESISTANCE DIVERTER VALVE HARNESS
DISCONNECT THE LEAD FROM THE DIVERTER VALVE MOTOR
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
OBSERVATION DIVERTER VALVE HEAD OPERATION
{USEINSMAT}
REMOV
RESISTANCE DIVERTER VALVE HARNESS
DISCONNECT THE LEAD FROM THE DIVERTER VALVE MOTOR
OBSERVATION PUMP RUNS DHW DEMAND
ENSURE APPLIANCE IS COOL
SET FLOW RATE TO APPROX. 3 LITRES A MINUTE
RESISTANCE PUMP AND HARNESS
DISCONNECT X11 AND X13 FROM THE PCB
RESISTANCE DIVERTER VALVE AND HARNESS
DISCONNECT CONNECTOR X13 FROM THE PCB
RESISTANCE FAN AND HARNESS (HV)
DISCONNECT X11 FROM THE PCB
RESISTANCE CLOCK MOTOR AND HARNESS
DISCONNECT X10 FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
GAIN ACCESS TO THE PCB
DISCONNECT CONNECTOR X14 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
GAIN ACCESS TO THE PCB
DISCONNECT CONNECTOR X14 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
RESISTANCE SPARK GENERATOR HARNESS
UNPLUG CONNECTOR X14 FROM THE PCB
UNPLUG THE CONNECTOR FROM THE SPARK GENERATOR
RESISTANCE HT LEAD
UNPLUG THE HT LEAD FROM THE SPARK ELECTRODE
RESISTANCE ELECTRODE EARTH LEAD
DISCONNECT THE WHITE EARTH LEAD FROM THE IGNITION ELECTRODE
INSPECTION OF IGNITION ELECTRODES
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
PRESSURE FAN MAXIMUM
DISCONNECT THE 4 WIR
PRESSURE GAS INLET AND DROP
GAS OFF
LOOSEN TH
VOLTAGE GAS VALVE AT PCB
{USEINSMAT}
GAIN ACCESS TO THE PCB
RESISTANCE GAS VALVE AND HARNESS
GAIN ACCESS TO THE PCB
DISCONNECT CONNECTOR X14 FROM THE PCB
INSPECTION OF FAN AND FAN VENTURI
REMOVE BURNER\FAN ASSEMBLY FROM BOILER
INSPECTION INJECTOR
UNDO THE NUT AT THE TOP OF THE GAS VALVE
INSPECTION OF IGNITION ELECTRODES
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
PRESSURE FAN MAXIMUM
DISCONNECT THE 4 WIR
PRESSURE GAS INLET
GAS OFF
LOOSEN TH
PRESSURE GAS INLET
GAS OFF
LOOSEN TH
INSPECTION OF FAN AND FAN VENTURI
REMOVE BURNER\FAN ASSEMBLY FROM BOILER
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
RESISTANCE THERMOSTAT OVERHEAT AND HARNESS
DISCONNECT PLUG X14 FROM THE PCB
OBSERVATION BOILER RESET (OVERHEAT)
ENSURE APPLIANCE IS COOL
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
VOLTAGE PCB TO FAN (MAINS)
{USEINSMAT}
REMOVE PCB COVER
RESISTANCE HARNESS FAN (HV)
UNPLUG THE 3 WIRE PLUG FROM THE FAN
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
INSPECTION OF FAN AND FAN VENTURI
REMOVE BURNER\FAN ASSEMBLY FROM BOILER
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
OBSERVATION DIVERTER VALVE HEAD OPERATION
{USEINSMAT}
REMOV
INSPECTION DIVERTER VALVE PIN MOVEMENT
REMOVE THE ACTUATOR HEAD FROM THE DIVERTER VALVE
RESISTANCE DIVERTER VALVE HARNESS
DISCONNECT THE LEAD FROM THE DIVERTER VALVE MOTOR
INSPECTION BYPASS OPERATION
DRAIN THE BOILERS HEATING CIRCUIT
INSPECTION HEATING FILTER
DRAIN THE BOILERS HEATING CIRCUIT
PRESSURE EXPANSION VESSEL
REMOVE THE CAP FROM THE EXPANSION VESSEL SCHRADER VALVE
DRAIN THE BOILER CENTRAL HEATING CIRCUIT
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
INSPECTION PRESSURE SENSOR BLOCKAGE
DRAIN THE HEATING CIRCUIT
OBSERVATION PUMP RUNS DHW DEMAND
ENSURE APPLIANCE IS COOL
SET FLOW RATE TO APPROX. 3 LITRES A MINUTE
TEMPERATURE DIFFERENTIAL (PRIMARY)
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS SHOWN
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
OBSERVATION RUN BOILER UP TO TEMP - DOES OVERHEAT OCCUR
ATTACH TEMPERATURE CLAMP TO THE FLOW PIPE AS SHOWN
VOLTAGE SWITCHED LIVE AT PCB
{USEINSMAT}
GAIN ACCESS TO THE PCB
RESISTANCE HARNESS X12 TO MAINS TERMINAL
DISCONNECT CONNECTOR X12 FROM THE PCB
VOLTAGE INTERNAL CLOCK
GAIN ACCESS TO THE 4 WIRE CONNECTOR ON THE LEFT OF THE PCB
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
MAINS VOLTAGE INPUT (BOILER SIDE)
{USEINSMAT}
REMOVE THE PCB COVER
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
VOLTAGE TO DISPLAY PCB
{USEINSMAT}
REMOV
RESISTANCE HARNESS DISPLAY PCB
DISCONNECT THE DISPLAY HARNESS FROM X40 ON THE MAIN PCB AND AT THE DISPLAY BOARD
VOLTAGE EXTERNAL CONTROLS (NO DEMAND)
{USEINSMAT}
GAIN ACCESS TO MAIN TERMINAL BLOCK
OBSERVATION ISOLATE DHW
TURN THE DHW ISOLATION VALVE OFF
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
VOLTAGE PCB TO FAN (LV)
DISCONNECT AND MAKE SAFE THE 4 WIRE LOW
VOLTAGE CONNECTOR FROM THE FAN
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
OBSERVATION BOILER HOT WATER OUTPUT TEMPERATURE
ATTACH TEMPERATURE PROBE TO THE HOT WATER OUTPUT PIPE OF THE BOILER
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
RESISTANCE TEMPERATURE SENSOR FLUE AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
PRESSURE FAN MAXIMUM
DISCONNECT THE 4 WIR
PRESSURE GAS INLET
GAS OFF
LOOSEN TH
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
PRESSURE FAN
LOOSEN THE SCREW OF
INSPECTION OF FAN AND FAN VENTURI
REMOVE BURNER\FAN ASSEMBLY FROM BOILER
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
TEMPERATURE DIFFERENTIAL (PRIMARY)
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS SHOWN
RESISTANCE DIVERTER VALVE AND HARNESS
DISCONNECT CONNECTOR X13 FROM THE PCB
OBSERVATION DISCONNECT X22
DISCONNECT CONNECTOR X22 FROM THE PCB AND MAKE SAFE
RESISTANCE PUMP HARNESS
DISCONNECT THE PLUG FROM THE PUMP
TEMPERATURE DIFFERENTIAL (PRIMARY)
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS SHOWN
RESISTANCE PUMP HARNESS
DISCONNECT THE PLUG FROM THE PUMP
TEMPERATURE DIFFERENTIAL (PRIMARY)
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS SHOWN
TEMPERATURE DIFFERENTIAL (HEATING)
ATTACH TEMPERATURE C
RESISTANCE PUMP HARNESS
DISCONNECT THE PLUG FROM THE PUMP
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
TEMPERATURE DIFFERENTIAL (PRIMARY)
ATTACH TEMPERATURE CLAMPS TO PRIMARY FLOW AND RETURN AS SHOWN
INSPECTION INJECTOR
UNDO THE NUT AT THE TOP OF THE GAS VALVE
INSPECTION MAIN BURNER
REMOVE THE FULL BURNER AND FAN ASSEMBLY FROM THE APPLIANCE
INSPECTION OF MAIN HEAT EXCHANGER
REMOVE FAN/BURNER ASSEMBLY
INSPECTION MAINS WATER FILTER AND RESTRICTOR
ISOLATE THE COLD WATER SUPPLY TO THE BOILER
DRAIN THE HOT WATER CIRCUIT
VOLTAGE PUMP FROM PCB
{USEINSMAT}
REMOVE PCB COVER
RESISTANCE PUMP HARNESS
DISCONNECT THE PLUG FROM THE PUMP
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
INSPECTION WATER FLOW TURBINE
ISOLATE THE COLD WATER SUPPLY TO THE BOILER
DRAIN THE HOT WATER CIRCUIT
RESISTANCE DHW HALL SENSOR HARNESS
UNCLIP THE HALL SENSOR FROM BELOW THE TURBINE THEN DISCONNECT THE HARNESS FROM THE HALL SENSOR
RESISTANCE TEMPERATURE SENSOR RETURN AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
OBSERVATION ISOLATE DHW (NO PUMP)
TURN THE DHW ISOLATION VALVE OFF
RESISTANCE FLOW SWITCH AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE FLOW SWITCH AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
OBSERVATION ISOLATE DHW
TURN THE DHW ISOLATION VALVE OFF
RESISTANCE OF FLOW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X22 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR AND HARNESS
DISCONNECT PLUG X21 FROM PCB
VOLTAGE RECTIFICATION - AC
{USEINSMAT}
GAIN ACCESS TO THE PCB
VOLTAGE RECTIFICATION - DC
{USEINSMAT}
GAIN ACCESS TO THE PCB
INSPECTION OF FLAME DETECTION ELECTRODE
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
RESISTANCE SENSOR FLOW
DISCONNECT THE HARNESS PLUG FROM THE FLOW THERMISTOR
OBSERVATION DIVERTER VALVE HEAD OPERATION
{USEINSMAT}
REMOV
RESISTANCE DHW TEMPERATURE SENSOR
DISCONNECT THE HARNESS PLUG FROM THE DHW SENSOR
RESISTANCE DIVERTER VALVE HARNESS
DISCONNECT THE LEAD FROM THE DIVERTER VALVE MOTOR
RESISTANCE HARNESS FAN (LV)
DISCONNECT THE 4 WIRE PLUG FROM THE FAN
VOLTAGE PCB TO FAN (MAINS)
{USEINSMAT}
REMOVE PCB COVER
RESISTANCE HARNESS FAN (HV)
UNPLUG THE 3 WIRE PLUG FROM THE FAN