BAXI COMBI INSTANT 80E
GLOBALLY REPLACED
BAXI COMBI INSTANT 80E
REMOVAL OF THE F
DHW FAN RUNS
SELECTOR SWITCH TO D
DHW BURNER IGNITION
ATTACH PRESSURE GAUG
DHW BURNER ESTABLISHED
ATTACH PRESSURE GAUG
DHW OPERATION
SELECTOR SWITCH TO D
DHW MODULATION
SET FLOW RATE AT TAP
CH OPERATION
SELECTOR SWITCH TO D
SYSTEM PRESSURE RISE
SELECTOR SWITCH TO D
CH MODULATION
ATTACH PRESSURE GAUG
RE-IGNITION DELAY
SELECTOR SWITCH TO D
PUMP OVERRUNS
SELECTOR SWITCH TO D
DHW PREHEAT
SELECTOR SWITCH TO D
CH IGNITION
ATTACH PRESSURE GAUG
50 DEGREE LIGHT
BLANK PAGE
60 DEGREE LIGHT
BLANK PAGE
70 DEGREE LIGHT
BLANK PAGE
80 DEGREE LIGHT
BLANK PAGE
30 + 50 DEGREE LIGHTS
BLANK PAGE
30 + 40 DEGREE LIGHTS
BLANK PAGE
OBSERVATION MAINS LED ILLUMINATED
SELECTOR SWITCH IN CH AND DHW POSITION
DHW DEMAND LIGHT
TURN HOT WATER TAP O
DHW PUMP RUNS
SELECTOR SWITCH TO D
HEADER FOR FUSE INVESTIGATION
NOT USED
SETTING THE MULTIMETER TO DIODE TEST
THE IMAGES BELOW SHO
DHW BURNER ESTABLISHED
ELECTRODE - IGNITION - FRONT
FAULT CODE 80
SENSOR- TEMPERATURE
CHOICE OF DIAGNOSTICS
Z DUMMY
DHW BURNER ESTABLISHED
LEAD- SENSING ELECTRODE
DHW BURNER IGNITION
SWITCH - AIR PRESSURE
DHW BURNER IGNITION
PIPE - PRESSURE SWITCH
DHW BURNER IGNITION
VENTURI - PRESSURE SENSING
DHW BURNER IGNITION
FLUE
DHW BURNER ESTABLISHED
SENSOR- TEMPERATURE
NO SPARK
PCB
OVERHEAT THERMOSTAT RESISTANCE
LEAD - IGNITION ELECTRODE
NO SPARK
SPARK GAP
DHW BURNER IGNITION NO SPARKING APS WIRES
CABLE - FAN / PRESSURE SWITCH
FAULT CODE 50 FAN DOES NOT RUN
PIPE - PRESSURE SWITCH
FAULT CODE 50 FAN DOES NOT RUN
VENTURI - PRESSURE SENSING
FAULT CODE 50 NOT PROVING IN N/O
SWITCH - AIR PRESSURE
FAULT CODE 50 FAN RUNS
PIPE - PRESSURE SWITCH
FAULT CODE 50 FAN RUNS
VENTURI - PRESSURE SENSING
FAULT CODE 50
FLUE
FAULT CODE 30 + 40
THERMOSTAT - LIMIT
DHW PUMP RUNS
DIAPHRAGM - DHW/DIFF - INSTANT
DHW PUMP RUNS
PIPE - POSITIVE / NEGATIVE PRESSURE
DHW VENTURI
HYDRAULIC VENTURI ASSEMBLY
DHW DEMAND ENDS
CABLE - LOW VOLTAGE
DHW PUMP RUNS
SWITCH - SELECTOR
DHW PUMP RUNS
SENSOR- TEMPERATURE
DHW PUMP RUNS
DIAPHRAGM - PRESSURE - THERMOSTAT
FAULT CODE 60
CABLE - LOW VOLTAGE
FAULT CODE 50 APS N/C WIRE
CABLE - FAN / PRESSURE SWITCH
OVERHEAT INVESTIGATION
SYSTEM PRESSURE
OVERHEAT INVESTIGATION
SENSOR - TEMPERATURE
OVERHEAT INVESTIGATION
SENSOR- TEMPERATURE
GAS VALVE BLOWING PCB
PCB AND GAS VALVE
FAULT CODE 30 AND 50 DEGREE LIGHT
PIPE - PRESSURE SWITCH
FAULT CODE 30 AND 50 DEGREE LIGHT
VENTURI - PRESSURE SENSING
OVERHEATING
TAP - ISOLATION - FLOW / RETURN
PUMP PROVING SWITCH
TAP - ISOLATION - FLOW / RETURN
BOILER TO TEMP RADS COOL
TAP - ISOLATION - FLOW / RETURN
BOILER AND RADS COOL
TAP - ISOLATION - FLOW / RETURN
RESTRICTED OR BLOCKED 2
FILTER RETURN
RESTRICTED OR BLOCKED 3
FILTER RETURN
RESTRICTED OR BLOCKED 4
FILTER RETURN
PREHEAT
PCB LINK A10 AND A11
PUMP NOT RUNNING PREHEAT
PCB LINK A10 AND A11
DHW FAN RUNS
THERMOSTAT - LIMIT
FILTER
FILTER - DHW INLET
DHW FLOW RATE
DHW FLOW RESTRICTOR/FILTER
INSUFFICIENT
WATER SUPPLY
DROPPING OUT
SWITCH - AIR PRESSURE
DROPPING OUT
PIPE - PRESSURE SWITCH
BURNER DROPPING OUT
HEAT EXCHANGER - PRIMARY
AIR FLOW DROPPING OUT
VENTURI - PRESSURE SENSING
CH IGNITION
SWITCH - SELECTOR
CH IGNITION
TIMER LINK
NO IGNITION
TIMER (CLOCK)
NOT RAMPING UP
SENSOR- TEMPERATURE
NOT RAMPING UP ON CH
THERMOSTAT CONTROLS
DHW SENSOR
CABLE - LOW VOLTAGE
FAULT CODE 70
CABLE - LOW VOLTAGE
POOR DHW
HEAT EXCHANGER - PRIMARY
OVERHEAT INVESTIGATION
GAS VALVE
RESTRICTED OR BLOCKED 5
FILTER RETURN
OVERHEATING
HEAT EXCHANGER - PRIMARY
EARTH LEAKAGE 2
CABLE - GAS VALVE/IGNITER
EARTH LEAKAGE 3
CABLE - GAS VALVE/IGNITER
BLOWING FUSE
GAS VALVE
BLOWING FUSE
CABLE - GAS VALVE/IGNITER
BLOWING FUSE
MOTOR - 3 - WAY -VALVE
BLOWING FUSE
FAN
BLOWING FUSE
PUMP
BLOWING FUSE 2
CABLE - GAS VALVE/IGNITER
BLOWN
FUSE MAINS
DHW PUMP RUNS
FUSE 2A 250V
BLANK FOR SETTING METER TO DIODE
Z DUMMY
NO PREHEAT
THERMOSTAT CONTROLS
NO DEMAND
THERMOSTAT CONTROLS
WATER LEAK
DIVERTER VALVE BODY AND HEAD
FAN NOT RUNNING FAULT CODE
PCB LINK A10 AND A11
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY CHECKS
NO DEMAND 2
THERMOSTAT CONTROLS
CH OPERATION
SENSOR- TEMPERATURE
DHW SENSOR 2
CABLE - LOW VOLTAGE
DHW FAN RUNS
SENSOR- TEMPERATURE
FAN RUNS
SYSTEM PRESSURE
PUMP PROVING SWITCH 2
TAP - ISOLATION - FLOW / RETURN
CH SPINDLE
PUMP
RESTRICTED OR BLOCKED
FILTER RETURN
DHW FAN RUNS
CABLE - LOW VOLTAGE
LOCK OUT RESET
SWITCH - SELECTOR
EARTH LEAKAGE
CABLE - GAS VALVE/IGNITER
STUCK IN PRE HEAT
THERMOSTAT CONTROLS
EARTH LEAKAGE 2 3
CABLE - GAS VALVE/IGNITER
EARTH LEAKAGE 3 3
CABLE - GAS VALVE/IGNITER
FAULT CODE 80
SWITCH - SELECTOR
OVERHEAT INVESTIGATION80 DEG OVERHEAT
SYSTEM PRESSURE
OVERHEAT INVESTIGATION80 DEG OVERHEAT
TAP - ISOLATION - FLOW / RETURN
80 DEG OVERHEAT
SENSOR - TEMPERATURE
OVERHEATING80 DEG OVERHEAT
HEAT EXCHANGER - PRIMARY
OVERHEAT INVESTIGATION80 DEG OVERHEAT
GAS VALVE
RESTRICTED OR BLOCKED 580 DEG OVERHEAT
FILTER RETURN
FAULT CODE 70
SWITCH - SELECTOR
FAULT CODE 70 - FAULTING DURING OPERATION
SENSOR - TEMPERATURE
DHW OPERATION DHW COOL RADS HOT
CABLE - 3-WAY VALVE MOTOR
CH OPERATION UP TO TEMP RADS COOL
CABLE - 3-WAY VALVE MOTOR
FAULT CODE 60
PIPE ASSEMBLY - BYPASS
CH NOISY DHW OK
PUMP
FAULT CODE 30 + 40 DHW DEMAND ENDS
CABLE - LOW VOLTAGE
CH OPERATION CH NOISY DHW OK
PIPE ASSEMBLY - BYPASS
FAULT CODE 30 + 40DHW PUMP RUNS
DIAPHRAGM - DHW/DIFF - INSTANT
FAULT CODE 30 + 40DHW PUMP RUNS
PIPE - POSITIVE / NEGATIVE PRESSURE
FAULT CODE 30 + 40DHW VENTURI
HYDRAULIC VENTURI ASSEMBLY
FAULT CODE 30 + 40EARTH LEAKAGE 2 3
CABLE - GAS VALVE/IGNITER
FAULT CODE 80 DHW DEMAND ENDS
CABLE - LOW VOLTAGE
FAULT CODE 80 DHW PUMP RUNS
DIAPHRAGM - DHW/DIFF - INSTANT
SYSTEM PRESSURE RISE
VESSEL - EXPANSION WITH STORAGE
FAULT CODE 80 DHW PUMP RUNS
PIPE - POSITIVE / NEGATIVE PRESSURE
FAULT CODE 80 DHW VENTURI
HYDRAULIC VENTURI ASSEMBLY
FAULT CODE 80 EARTH LEAKAGE 2 3
CABLE - GAS VALVE/IGNITER
PUMP OVERRUNS
PCB
FAULT CODE 80
VALVE - 3 WAY ASSEMBLY
FAULT CODE 80
CABLE - 3-WAY VALVE MOTOR
FAULT CODE 30 + 40
VALVE - 3 WAY ASSEMBLY
FAULT CODE 30 + 40 FAULT CODE 80
CABLE - 3-WAY VALVE MOTOR
DHW IGNITION
GAS VALVE COMPENSATION TUBE
DHW BURNER ESTABLISHED BURNER IGNITION PRESSURE LOW OR DIES OUT
GAS INLET PRESSURE
CH IGNITION
GAS VALVE COMPENSATION TUBE
EARTH LEAKAGE 5
CABLE - GAS VALVE/IGNITER
BURNER PRESSURE EXC
GAS VALVE COMPENSATION TUBE
SPARK NO GAS
GAS VALVE COMPENSATION TUBE
FLAME SENSE POSITION
FLAME SENSE GAP
CH OPERATION FIRES WITH NO DEMAND
SENSOR- TEMPERATURE
DHW MODULATION
SENSOR - TEMPERATURE
CH MODULATION
SENSOR- TEMPERATURE
DHW FAN RUNS
PIPE - PRESSURE SWITCH
CH OPERATION
VALVE - 3 WAY ASSEMBLY
DHW FAN RUNS
VENTURI - PRESSURE SENSING
LETTING BY
PRESSURE DIFFERENTIAL ASSEMBLY
DHW BURNER ESTABLISHED
HEAT EXCHANGER - PRIMARY
DHW BURNER ESTABLISHED BURNER IGNITES BUT BAFFLES OUT
GAS INLET PRESSURE
DHW FAN RUNS
FLUE
BURNER PRESSURE LOW
SENSOR - TEMPERATURE
DHW COLD RADS COLD
THERMOSTAT CONTROLS
DHW COLD RADS COLD
SENSOR - TEMPERATURE
DHW OPERATION
MANIFOLD - BURNER
DHW OPERATION
PIPE ASSEMBLY - BYPASS
CH IGNITION2
SWITCH - SELECTOR
CH IGNITION2
TIMER LINK
NO IGNITION2
TIMER (CLOCK)
SPARK GAS PRESENT NO IGNITION
SPARK GAP
DHW BURNER IGNITION
GAS INLET PRESSURE
FAULT CODES PAGE
Z DUMMY
FAULT CODE 60
SYSTEM PRESSURE
FAULT CODE 60 LIMPET
PUMP
FAULT CODE 60
DIAPHRAGM - PRESSURE - THERMOSTAT
FAULT CODE 60
VALVE - 3 WAY ASSEMBLY (CH SPINDLE)
FAULT CODE 60
VALVE - 3 WAY ASSEMBLY
DHW FAN RUNS APS WIRES
CABLE - FAN / PRESSURE SWITCH
FAULT CODE 80
CABLE - LOW VOLTAGE
DHW BURNER IGNITION
IGNITOR C/W LEAD
DHW BURNER IGNITION
ELECTRODE - IGNITION
FAULT CODE 50 APS N/O WIRES
CABLE - FAN / PRESSURE SWITCH
FAULT CODE 50 NOT PROVING IN N/C
SWITCH - AIR PRESSURE
SELECTOR SWITCH
SWITCH - SELECTOR
DHW PUMP RUNS
CABLE - PCB INPUT
NO DHW DEMAND
CABLE - LOW VOLTAGE
DHW PUMP RUNS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
DHW DEMAND ENDS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
DHW DEMAND ENDS
DIAPHRAGM - DHW/DIFF - INSTANT
SERVICE KIT
VALVE - DIFFERENTIAL - DHW
CH IGNITION
PCB
DHW PUMP RUNS
PUMP
DHW PUMP RUNS
VALVE - 3 WAY ASSEMBLY (CH SPINDLE)
SENSOR CH
CABLE - LOW VOLTAGE
DHW PUMP RUNS
CABLE - LOW VOLTAGE
STICKING JAMMING DHW SPINDLE
PRESSURE DIFFERENTIAL ASSEMBLY
FAULT CODE 30 AND 50 DEGREE LIGHT
CABLE - FAN / PRESSURE SWITCH
FAULT CODE 30 AND 50 DEGREE LIGHT
SWITCH - AIR PRESSURE
OVERHEAT SECTION
CABLE - FAN / PRESSURE SWITCH
OVERHEAT SECTION 2
CABLE - FAN / PRESSURE SWITCH
DHW FLOW RATE
HEAT EXCHANGER 20 PLATES - DHW
POOR AIRFLOW
FAN
CH IGNITION
EXT CONTROLS / LINK
CH IGNITION 2
PCB
DHW PUMP RUNS
SENSOR - TEMPERATURE
DHW MODULATION
PCB
FAULT CODE 70
SENSOR - TEMPERATURE
DHW TEMPERATURE LOW RADIATORS COLD
HEAT EXCHANGER 20 PLATES - DHW
TRIPPING EARLY
THERMOSTAT - LIMIT
OVERHEAT INVESTIGATION
OVERHEAT
OVERHEATING
HEAT EXCHANGER 20 PLATES - DHW
EARTH LEAKAGE 2
GAS VALVE
EARTH LEAKAGE 3
GAS VALVE
BLOWING FUSE
CABLE - 3-WAY VALVE MOTOR
BLOWING FUSE
CABLE - FAN / PRESSURE SWITCH
BLOWING FUSE
CABLE - SELECTOR SWITCH/PUMP
BLOWING FUSE
PCB FUSE INVESTIGATION
BLANK FOR FUSE INVESTIGATION
Z DUMMY
BLANK FOR FUSE INVESTIGATION 2
Z DUMMY
DHW PREHEAT
PCB
FAULT CODE 60
PCB
NO POWER TO FAN
CABLE - FAN / PRESSURE SWITCH
DHW FAN RUNS
SENSOR - TEMPERATURE
RESTRICTED STOPPING FAN RUNNING
VALVE - 3 WAY ASSEMBLY
FAN RUNS
VALVE - 3 WAY ASSEMBLY (CH SPINDLE)
DHW FAN RUNS
DIAPHRAGM - PRESSURE - THERMOSTAT
BLOCKED NO FAN
HEAT EXCHANGER - PRIMARY
DHW FAN RUNS
PCB
NO POWER TO FAN 2
CABLE - FAN / PRESSURE SWITCH
EARTH LEAKAGE
GAS VALVE
EARTH LEAKAGE 2 3
GAS VALVE
EARTH LEAKAGE 3 3
GAS VALVE
FAULT CODE 80
PCB
OVERHEATING80 DEG OVERHEAT
HEAT EXCHANGER 20 PLATES - DHW
FAULT CODE 80 NO FAULT OVERHEAT
SENSOR- TEMPERATURE
FAULT CODE 70
PCB
FAULT CODE 70
Z BLANK FOR FUSE INVESTIGATION
DHW OPERATION
MOTOR - 3 - WAY -VALVE
CH OPERATION
MOTOR - 3 - WAY -VALVE
FAULT CODE 60
HEAT EXCHANGER - PRIMARY
FAULT CODE 60
Z BLANK FOR FUSE INVESTIGATION
FAULT CODE 30 + 40DHW DEMAND ENDS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
FAULT CODE 30 + 40DHW DEMAND ENDS
DIAPHRAGM - DHW/DIFF - INSTANT
FAULT CODE 30 + 40SERVICE KIT
VALVE - DIFFERENTIAL - DHW
FAULT CODE 30 + 40STICKING JAMMING DHW SPINDLE
PRESSURE DIFFERENTIAL ASSEMBLY
FAULT CODE 30 + 40NO DHW DEMAND
CABLE - LOW VOLTAGE
FAULT CODE 30 + 40DHW PUMP RUNS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
FAULT CODE 30 + 40EARTH LEAKAGE 2 3
GAS VALVE
FAULT CODE 80 DHW DEMAND ENDS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
FAULT CODE 80 DHW DEMAND ENDS
DIAPHRAGM - DHW/DIFF - INSTANT
FAULT CODE 80 SERVICE KIT
VALVE - DIFFERENTIAL - DHW
FAULT CODE 80 STICKING JAMMING DHW SPINDLE
PRESSURE DIFFERENTIAL ASSEMBLY
FAULT CODE 80 NO DHW DEMAND
CABLE - LOW VOLTAGE
FAULT CODE 80 DHW PUMP RUNS
VALVE - DIFFERENTIAL - DHW (SPINDLE)
FAULT CODE 80 EARTH LEAKAGE 2 3
GAS VALVE
FAULT CODE 80
MOTOR - 3 - WAY -VALVE
FAULT CODE 30 + 40 FAULT CODE 80
MOTOR - 3 - WAY -VALVE
EARTH LEAKAGE 5
GAS VALVE
MINIMUM SET WRONG ON MODUREG
GAS VALVE
CH MODULATION
PCB
DHW OPERATION
HEAT EXCHANGER 20 PLATES - DHW
DHW FAN RUNS
FAN
DHW OPERATION
VALVE - 3 WAY ASSEMBLY
DHW FAN RUNS
SWITCH - AIR PRESSURE
DHW OPERATION
HEAT EXCHANGER - PRIMARY
CH IGNITION2
EXT CONTROLS / LINK
DHW BURNER IGNITION
MANIFOLD - BURNER
CH IGNITION 22
PCB
FAULT 1
CABLE - GAS VALVE/IGNITER
MECHANICAL 2
GAS VALVE
FAULT CODE 60
PUMP
DIAPHRAGM SPLIT OR WORN
CHARACTERISTIC TEST FROM INSPECTION CH DIFFERENTIAL VALVE
SPINDLE CORRODED OR SEIZED
CHARACTERISTIC TEST FROM INSPECTION CH DIFFERENTIAL VALVE
DIFFERENTIAL WATERWAYS BLOCKED
CHARACTERISTIC TEST FROM INSPECTION CH DIFFERENTIAL VALVE
MAINS LED FLASHING
CHARACTERISTIC TEST FROM OBSERVATION MAINS LED ILLUMINATED
MAINS LED NOT ILLUMINATED
CHARACTERISTIC TEST FROM OBSERVATION MAINS LED ILLUMINATED
HOT WATER LIGHT REMAINS ON WITH TAP TURNED OFF
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
HOT WATER LIGHT DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
DIAPHAGM WORN AND / OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
DIFFERENTIAL VALVE - STUFFING BOX LEAKING
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
PUMP PULSES ON AND OFF
CHARACTERISTIC TEST FROM DHW PUMP RUNS
PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM DHW PUMP RUNS
DHW noisy operation
CHARACTERISTIC TEST FROM DHW OPERATION
ALL DIFFERENTIAL VALVE COMPONENTS OK
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
DHW temperature low, radiators cold
CHARACTERISTIC TEST FROM DHW OPERATION
DHW temperature low, radiators hot
CHARACTERISTIC TEST FROM DHW OPERATION
BURNER IGNITES BUT BURNER PRESSURE EXCESSIVE
CHARACTERISTIC TEST FROM DHW BURNER IGNITION
BURNER IGNITES PRESSURE STARTS TO RAMP UP BUT THEN DROPS OUT AND RE IGNITES
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISHED
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH IGNITION
BURNER IGNITES BUT PRESSURE DOES NOT BEHAVE AS DESCRIBED
CHARACTERISTIC TEST FROM CH IGNITION
BOILER CONTINUES TO HEAT PAST 85 DEGREES
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
BOILER OVERHEATS BELOW 85 DEGREES
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
HOT WATER LIGHT FLASHES WITH DEMAND
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
BOILER AND RADIATORS ONLY GET WARM
CHARACTERISTIC TEST FROM CH OPERATION
BOILER UP TO TEMPERATURE RADIATORS COOL
CHARACTERISTIC TEST FROM CH OPERATION
NO RE IGNITION DELAY
CHARACTERISTIC TEST FROM RE-IGNITION DELAY
APPLIANCE/SYSTEM COOL, BOILER DOES NOT RE-IGNITE
CHARACTERISTIC TEST FROM RE-IGNITION DELAY
CH noisy, DHW OK
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL WATERWAYS BLOCKED
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
SPINDLE CORRODED OR SEIZED
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
DIAPHRAGM SPLIT OR WORN
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
HOT WATER LIGHT REMAINS ON WITH TAP TURNED OFF
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
DIAPHAGM WORN AND / OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
DIFFERENTIAL VALVE - STUFFING BOX LEAKING
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
ALL DIFFERENTIAL VALVE COMPONENTS OK
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
HOT WATER LIGHT DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
HOT WATER LIGHT REMAINS ON WITH TAP TURNED OFF
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
DIAPHAGM WORN AND / OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
DIFFERENTIAL VALVE - STUFFING BOX LEAKING
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
ALL DIFFERENTIAL VALVE COMPONENTS OK
CHARACTERISTIC TEST FROM INSPECTION DIFFERENTIAL VALVE DHW
HOT WATER LIGHT DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM DHW DEMAND LIGHT
Fires with no demand
CHARACTERISTIC TEST FROM CH OPERATION
Fan does not run
CHARACTERISTIC TEST FROM DHW FAN RUNS
Fan runs then stops
CHARACTERISTIC TEST FROM DHW FAN RUNS
No sparkING PRESENT
CHARACTERISTIC TEST FROM DHW BURNER IGNITION
Sparking OK, ZERO OR LOW gas PRESSURE present
CHARACTERISTIC TEST FROM DHW BURNER IGNITION
Sparking OK, gas PRESSURE present BUT no ignition
CHARACTERISTIC TEST FROM DHW BURNER IGNITION
BOILER STILL NOISY
CHARACTERISTIC TEST FROM RE-IGNITION DELAY
BOILER DOES NOT REACT TO CH DEMAND
CHARACTERISTIC TEST FROM RE-IGNITION DELAY
PRESSURE LOW OR DIES OUT
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISHED
Burner ignites but baffles out
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISHED
BURNER IGNITES, SPARK CONTINUES, BOILER GOES TO LOCKOUT
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISHED
03/07/2018 09:14:32 1807_1_50_1 20/07/2018 13:56:50
06/07/2018 11:17:04
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
RESISTANCE HARNESS DHW
REMOVE CONNECTOR A5 FROM THE PCB
REMOVE THE CONNECTOR FROM THE DHW THERMISTOR
CH SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
AIR PRESSURE SWITCH RESISTANCE
DISCONNECT THE BLUE LEAD FROM THE AIR PRESSURE SWITCH
RESISTANCE HARNESS APS (N/O)
{GAINPCBACS}
DISCONNECT A2 FROM THE PCB
DISCONNECT THE BLUE WIRE FROM THE APS
SPARK GENERATOR (INPUT)
SELECTOR SWITCH TO D
OBSERVATION FAN RUNS PREHEAT
SELECTOR SWITCH TO D
RESISTANCE HARNESS AND APS (N/C)
{GAINPCBACS}
DISCONNECT CONNECTOR A2 FROM THE PCB
AIR PRESSURE SWITCH RESISTANCE
DISCONNECT THE BLUE LEAD FROM THE AIR PRESSURE SWITCH
OBSERVATION BOILER RESET
ENSURE APPLIANCE IS COOL
OVERHEAT THERMOSTAT RESISTANCE
REMOVE MOULDED PLUG FROM OVERHEAT THERMOSTAT
FUSE F1 RESISTANCE
REMOVE FUSE AND HOLDER LOCATED IN THE MAIN TERMINAL BLOCK
DHW DEMAND
REMOVE DHW MICRO SWITCH HEAD
DHW DIAPHRAGM
BOILER DRAINED AND DISCHARGED
INSPECTION DIFFERENTIAL VALVE DHW
ISOLATE DHW COLD FEED TO BOILER
DRAIN DHW SYSTEM
REMOVE DHW DIFFERENTIAL VALVE FROM BOILER
CH DEMAND MICRO SWITCH OPEN CIRCUIT
DISCONNECT CONNECTOR A5 FROM THE PCB
CH SPINDLE RETRACTED
SELECTOR SWITCH IN OFF POSITION
REMOVE THE CH DIFFERENTIAL PRESSURE SWITCH MICRO SWITCH
CH DIAPHRAGM
BOILER DRAINED AND DISCHARGED
RESISTANCE HARNESS DHW
REMOVE CONNECTOR A5 FROM THE PCB
REMOVE THE CONNECTOR FROM THE DHW THERMISTOR
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
RESISTANCE HARNESS APS (N/O)
{GAINPCBACS}
DISCONNECT A2 FROM THE PCB
DISCONNECT THE BLUE WIRE FROM THE APS
RESISTANCE GAS VALVE
DISCONNECT CONNECTOR PLUG FROM GAS VALVE
RESISTANCE AIR PRESSURE SWITCH & HARNESS (NC)
{GAINPCBACS}
DISCONNECT CONNECTOR A2 FROM THE PCB
RESISTANCE APS AT APS (NC)
DISCONNECT THE BLUE LEAD FROM THE AIR PRESSURE SWITCH, MAKE A NOTE OF CONNECTIONS
INSPECTION PCB LINK A10 AND A11
{GAINPCBACS}
INSPECTION PCB LINK A10 AND A11
{GAINPCBACS}
OVERHEAT THERMOSTAT RESISTANCE
REMOVE MOULDED PLUG FROM OVERHEAT THERMOSTAT
RESISTANCE OVERHEAT THERMOSTAT AND HARNESS
REMOVE CONNECTOR A2 FROM THE PCB
WATER SUPPLY TO PREMISES
TURN ON A COLD WATER TAP
EXTERNAL CONTROLS/RTC INPUT
{GAINPCBACS}
SELE
TIMER LINK IN VOLTS INPUT
SELECTOR SWITCH TO D
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
TEMPERATURE DIFFERENTIAL CH
ATTACH FGA TEMPERATU
TEMPERATURE DIFFERENTIAL CH
ATTACH FGA TEMPERATU
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
RESISTANCE PUMP AND HARNESS FUSE INVESTIGATION
REMOVE CONNECTOR A4 FROM THE PCB
RESISTANCE PUMP FUSE INVESTIGATION
REMOVE THE COVER FROM THE PUMP ASSEMBLY
REMOVE THE WIRES FROM THE PUMP ASSEMBLY
RESISTANCE FAN FUSE INVESTIGATION
DISCONNECT LIVE AND NEUTRAL LEADS FROM THE FAN
RESISTANCE DIVERTER VALVE HEAD FUSE INVESTIGATION
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE HEAD
RESISTANCE FUSE MAINS
GAIN ACCESS TO THE MAINS FUSE FOR THE APPLIANCE
VOLTAGE FAN AT PCB PREHEAT
{GAINPCBACS}
DHW PREHEAT SELECTOR TO MAX POSITION
ENSURE APPLIANCE IS COOL
INSPECTION PCB LINK A10 AND A11
{GAINPCBACS}
VOLTAGE FAN AT PCB
{GAINPCBACS}
SELE
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
RESISTANCE HARNESS DHW
REMOVE CONNECTOR A5 FROM THE PCB
REMOVE THE CONNECTOR FROM THE DHW THERMISTOR
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
SELECTOR SWITCH (LOCKOUT/RESET)
REMOVE RED AND BLUE
TEMPERATURE DIFFERENTIAL CH
ATTACH FGA TEMPERATU
SELECTOR SWITCH (LOCKOUT/RESET)
REMOVE RED AND BLUE
INSPECTION DIFFERENTIAL VALVE DHW
ISOLATE DHW COLD FEED TO BOILER
DRAIN DHW SYSTEM
REMOVE DHW DIFFERENTIAL VALVE FROM BOILER
DHW DEMAND
REMOVE DHW MICRO SWITCH HEAD
DHW DIAPHRAGM
BOILER DRAINED AND DISCHARGED
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
INSPECTION DIFFERENTIAL VALVE DHW
ISOLATE DHW COLD FEED TO BOILER
DRAIN DHW SYSTEM
REMOVE DHW DIFFERENTIAL VALVE FROM BOILER
DHW DEMAND
REMOVE DHW MICRO SWITCH HEAD
DHW DIAPHRAGM
BOILER DRAINED AND DISCHARGED
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
SELE
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
SELE
EARTH LEAKAGE CHECK GAS VALVE DISCONNECTED
REMOVE THE CONNECTOR FROM THE GAS VALVE
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
SELE
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
SELE
EXTERNAL CONTROLS/RTC INPUT
{GAINPCBACS}
SELE
TIMER LINK IN VOLTS INPUT
SELECTOR SWITCH TO D
VOLTAGE GAS VALVE AT PCB
SELECTOR SWITCH TO D
OBSERVATION PUMP RUNS PREHEAT
SELECTOR SWITCH TO D
VOLTAGE PUMP PREHEAT
{GAINPCBACS}
SELE
GAS INLET PRESSURE
ATTACH PRESSURE GAUG
RESISTANCE AIR PRESSURE SWITCH WITH KIT
DISCONNECT LEADS FROM THE AIR PRESSURE SWITCH NOTING THE CONNECTIONS
OBSERVATION SPARKING WITH APS PROVEN
CONNECT THE AIR PRESSURE SWITCH CHARGE KIT TO +VE CONNECTION ON THE AIR PRESSURE SWITCH.
SPARK GENERATOR (OUTPUT)
REMOVE THE LEAD FROM
ELECTRODE LEAD
REMOVE THE ELECTRODE LEAD
RESISTANCE AIR PRESSURE SWITCH WITH KIT
DISCONNECT LEADS FROM THE AIR PRESSURE SWITCH NOTING THE CONNECTIONS
VOLTAGE FAN PREHEAT
DHW PREHEAT SELECTOR TO MAX POSITION
ENSURE APPLIANCE IS COOL
OBSERVATION SPARKING WITH APS PROVEN
CONNECT THE AIR PRESSURE SWITCH CHARGE KIT TO +VE CONNECTION ON THE AIR PRESSURE SWITCH.
POWER TO CONTROL BOARD
{GAINPCBACS}
SELECTOR SWITCH TO DHW POSITION
SELECTOR SWITCH VOLTAGE
SELECTOR SWITCH TO OFF POSITION
OPERATION DIFFERENTIAL VALVE DHW
REMOVE DHW MICRO SWITCH HEAD
DHW DEMAND MICRO SWITCH OPERATION
REMOVE CONNECTOR A5 FROM THE PCB
DHW SENSING PIPES
DHW ISOLATED AND DISCHARGED
INSPECTION FILTER AND VENTURI CARTRIDGE
DHW ISOLATED AND DISCHARGED
REMOVE THE FILTER/VENTURI CARTRIDGE FROM THE RIGHT HAND HYDRO BLOCK
RESISTANCE DHW MICROSWITCH AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
DHW TAPS OFF
PUMP VOLTS DHW
{GAINPCBACS}
SELE
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
CH SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
SELECTOR SWITCH (LOCKOUT/RESET)
REMOVE RED AND BLUE
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
CH SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
RESISTANCE MODULATING SOLENOID
REMOVE THE BLACK LEADS FROM THE MODULATING SOLENOID
RESISTANCE FAN
DISCONNECT LIVE AND NEUTRAL LEADS FROM THE FAN
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
RESISTANCE OVERHEAT THERMOSTAT AND HARNESS
REMOVE CONNECTOR A2 FROM THE PCB
DHW INLET FILTER
DHW CIRCUIT OF APPLIANCE DRAINED AND DISCHARGED.
DHW FLOW RESTRICTOR/FILTER
DHW ISOLATED, DRAINED AND DISCHARGED
RESISTANCE AIR PRESSURE SWITCH WITH KIT
DISCONNECT LEADS FROM THE AIR PRESSURE SWITCH NOTING THE CONNECTIONS
VOLTAGE FAN AT PCB AIR FLOW
{GAINPCBACS}
DHW PREHEAT SELECTOR TO MAX POSITION
VOLTAGE FAN AT PCB AIR FLOW
{GAINPCBACS}
DHW PREHEAT SELECTOR TO MAX POSITION
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
EXTERNAL CONTROLS/RTC OUTPUT
{GAINPCBACS}
SELE
CLOCK IN VOLTS INPUT
SELECTOR SWITCH TO D
TIMER LINK RESISTANCE
DISCONNECT CONNECTOR A3 FROM THE PCB
CLOCK RESISTANCE
DISCONNECT CONNECTOR A3 FROM THE PCB
SET CLOCK TO OFF POSITION
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATU
PRESSURE BURNER MAXIMUM AND MINIMUM
ATTACH PRESSURE GAUG
OBSERVATION RUN BOILER UP TO TEMPERATURE
CH TEMPERATURE SELEC
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
RESISTANCE FAN AND HARNESS FUSE INVESTIGATION
REMOVE CONNECTOR A2 FROM THE PCB
RESISTANCE DIVERTER VALVE AND HARNESS FUSE INVESTIGATION
REMOVE CONNECTOR A8 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY
DIODE TEST GAS VALVE HARNESS FUSE INVESTIGATION
REMOVE THE CONNECTOR
RESISTANCE GAS VALVE FUSE INVESTIGATION
DISCONNECT CONNECTOR PLUG FROM GAS VALVE
RESISTANCE GAS VALVE HARNESS FUSE INVESTIGATION
REMOVE CONNECTOR A1 FROM THE PCB
INSPECTION WATER INGRESS TO DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
CH SPINDLE
SELECTOR SWITCH IN O
CH DEMAND MICRO SWITCH OPERATION
REMOVE DHW MICROSWIT
INSPECTION CH DIFFERENTIAL VALVE
DRAIN APPLIANCE PRIM
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
SELECTOR SWITCH (LOCKOUT/RESET)
REMOVE RED AND BLUE
OBSERVATION BOILER RESET (CH SENSOR)
DHW TEMPERATURE SELECTOR TO MAX
DHW DEMAND LIGHT (OVERHEAT)
TURN HOT WATER TAP O
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATU
PRESSURE BURNER MAXIMUM AND MINIMUM
ATTACH PRESSURE GAUG
INSPECTION FILTER RETURN
APPLIANCE PRIMARY WA
DHW DEMAND LIGHT (OVERHEAT)
TURN HOT WATER TAP O
OBSERVATION RUN BOILER ON DHW
DHW TEMPERATURE SELECTOR TO MAX
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR A8 FROM THE PCB
DISCONNECT PLUG FROM DIVERTER VALVE
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR A8 FROM THE PCB
DISCONNECT PLUG FROM DIVERTER VALVE
BYPASS CHECK
BOILER DRAINED AND DISCHARGED
BYPASS CHECK
BOILER DRAINED AND DISCHARGED
OBSERVATION BOILER OPERATION (60 DEGREE)
DHW TEMPERATURE SELECTOR TO MAX
OPERATION DIFFERENTIAL VALVE DHW
REMOVE DHW MICRO SWITCH HEAD
RESISTANCE DHW MICROSWITCH AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
DHW TAPS OFF
DHW DEMAND MICRO SWITCH OPERATION
REMOVE CONNECTOR A5 FROM THE PCB
DHW SENSING PIPES
DHW ISOLATED AND DISCHARGED
INSPECTION FILTER AND VENTURI CARTRIDGE
DHW ISOLATED AND DISCHARGED
REMOVE THE FILTER/VENTURI CARTRIDGE FROM THE RIGHT HAND HYDRO BLOCK
OPERATION DIFFERENTIAL VALVE DHW
REMOVE DHW MICRO SWITCH HEAD
RESISTANCE DHW MICROSWITCH AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
DHW TAPS OFF
DHW DEMAND MICRO SWITCH OPERATION
REMOVE CONNECTOR A5 FROM THE PCB
DHW SENSING PIPES
DHW ISOLATED AND DISCHARGED
INSPECTION FILTER AND VENTURI CARTRIDGE
DHW ISOLATED AND DISCHARGED
REMOVE THE FILTER/VENTURI CARTRIDGE FROM THE RIGHT HAND HYDRO BLOCK
DIVERTER VALVE HEAD
SELECTOR SWITCH TO D
DIVERTER VALVE BODY
REMOVE DIVERTER VALVE HEAD
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR A8 FROM THE PCB
DISCONNECT PLUG FROM DIVERTER VALVE
DIVERTER VALVE HEAD
SELECTOR SWITCH TO D
DIVERTER VALVE BODY
REMOVE DIVERTER VALVE HEAD
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR A8 FROM THE PCB
DISCONNECT PLUG FROM DIVERTER VALVE
GAS INLET PRESSURE
ATTACH PRESSURE GAUG
MODULATING SOLENOID VOLTAGE
SELECTOR SWITCH TO D
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
CH OPERATION
SELECTOR SWITCH TO D
RESISTANCE HARNESS AND APS (N/C)
{GAINPCBACS}
DISCONNECT CONNECTOR A2 FROM THE PCB
FAN VOLTS
SELECTOR SWITCH TO O
DIVERTER VALVE HEAD
SELECTOR SWITCH TO D
DIVERTER VALVE HEAD
SELECTOR SWITCH TO D
DIVERTER VALVE BODY
REMOVE DIVERTER VALVE HEAD
PRESSURE DIFFERENTIAL ASSEMBLY (NON RETURN VALVE)
SET FLOW RATE TO APP
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
DHW SENSOR RESISTANCE AND HARNESS
REMOVE CONNECTOR A5 FROM THE PCB
INSPECTION BURNER INJECTORS
REMOVE BURNER ASSEMBLY
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATU
BYPASS CHECK
BOILER DRAINED AND DISCHARGED
EXTERNAL CONTROLS/RTC OUTPUT
{GAINPCBACS}
SELE
CLOCK IN VOLTS INPUT
SELECTOR SWITCH TO D
TIMER LINK RESISTANCE
DISCONNECT CONNECTOR A3 FROM THE PCB
CLOCK RESISTANCE
DISCONNECT CONNECTOR A3 FROM THE PCB
SET CLOCK TO OFF POSITION
CH SENSOR RESISTANCE
REMOVE CONNECTOR FROM CH THERMISTOR
GAS INLET PRESSURE
ATTACH PRESSURE GAUG
VOLTAGE GAS VALVE AT GAS VALVE
{GAINPCBACS}
SELE
CH SPINDLE
SELECTOR SWITCH IN O
CH DEMAND MICRO SWITCH OPERATION
REMOVE DHW MICROSWIT
INSPECTION CH DIFFERENTIAL VALVE
DRAIN APPLIANCE PRIM
System Information
- Total Tests: 628
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control