Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Attach pressure gauge to gas valve outlet pressure test point
Selector switch to DHW and CH position
CH temperature selector to maximum
DHW Preheat selector to Off position
Ensure CH system is cool
Selector switch to DHW and CH position
CH temperature selector to maximum
DHW Preheat selector to Off position
Ensure CH system is cool
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow fan to run and ignition sequence to commence.
Does the burner pressure behave as described above?
Note: When pressure gauge is removed pressure test point should be tightened and checked for gas soundness.
Does the burner pressure behave as described above?
Note: When pressure gauge is removed pressure test point should be tightened and checked for gas soundness.