Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
BAXI PRECISION + ERP
GLOBALLY REPLACED
POWER UP SELF TEST
CH TEMPERATURE CONTROL SET TO OFF POSITION
ENSURE APPLIANCE IS COOL
OBSERVATION FAN RUNS
ENSURE APPLIANCE IS COOL
CH OPERATION
CH TEMPERATURE CONTROL SET TO MAX
DHW OPERATION
HOT WATER DEMAND
OBSERVATION BURNER IGNITION & ESTABLISH
ENSURE APPLIANCE IS COOL
FAULT CODE - SENSORS
NOT USED
FAULT CODE - MISCELLANEOUS
NOT USED
FAULT CODE FAN FAULT
NOT USED
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
STATUS CODE - TEMPERATURE PROTECTION
NOT USED
STATUS CODE - SHUTDOWN INPUT
NOT USED
STATUS CODE - COMMUNICATION FAULT
NOT USED
STATUS CODE - MISCELLANEOUS
NOT USED
& FUSE PCB FURTHER INVESTIGATION
NOT USED
FAULT CODE - OVERHEAT
NOT USED
OBSERVATION EXTERNAL FROST PROTECTION
ENSURE THERE ARE NO DEMANDS FOR HEATING OR HOT WATER
OBSERVATION BOILER MODULATION
ATTACH TEMPERATURE CLAMP TO FLOW PIPE JUST ABOVE HEAT EXCHANGER
OBSERVATION SYSTEM PUMP RUNNING
CH TEMPERATURE CONTROL SET TO OFF POSITION
LOCATE & GAIN ACCESS TO SYSTEM PUMP
FAULT CODE - PARAMETER FAULT
NOT USED
SET UP FOR NEW PARAMETER UNIT
IF A NEW PARAMETER U
BOILER NOISY
FLUE
BOILER NOISY
COMBUSTION SEALS
BOILER NOISY
BURNER MESH C/W GASKET
BOILER NOISY
GAS VALVE ASSEMBLY
BOILER NOISY
GAS VALVE ADJUSTMENT
BURNER IGNITION 2
COMBUSTION CONTROL UNIT
BURNER IGNITION
FLUE
BURNER IGNITION
SET - ELECTRODES C/W SCREW & GASKET
BURNER IGNITION 2
BURNER MESH C/W GASKET
BOILER SYS COOL
KIT - SENSOR
BOILER SYS COOL 2
KIT - SENSOR
BOILER SYS COOL
CONTROLLER - USER INTERACTION
BOILER SYS COOL
FLUE
MODULATION
KIT - SENSOR
MODULATION 2
KIT - SENSOR
MODULATION
CONTROLLER - USER INTERACTION
BURNER DOES NOT IGNITE AND EST
COMBUSTION CONTROL UNIT
BURNER DOES NOT IGNITE & EST 2
SET - ELECTRODES C/W SCREW & GASKET
BURNER DOES NOT IGNITE & EST
BURNER MESH C/W GASKET
BURNER DOES NOT IGNITE & EST
AIR INTAKE
FAULT CODE PARAMETER
UNIT - PARAMETER
FAULT CODE PARAMETER
HARNESS - CABLE 24V HE
FAULT CODE PARAMETER 2
UNIT - PARAMETER
BLANK FOR PARAMETER UNIT REPLACEMENT
Z REDIRECTION
BLANK FOR PARAMETER UNIT SETUP
Z REDIRECTION
INFORMATION RESETTING APPLIANCE
Z REDIRECTION
CHIMNEY SWEEP ILLUMINATED SOLID
BUTTONS STUCK IN
FAN RUNS
KIT - SENSOR
FAN RUNS 2
KIT - SENSOR
FAN RUNS 2
CONTROLLER - USER INTERACTION
FUSE INVESTIGATION
FAN OR COMBUSTION CONTROL UNIT
FAULT CODES
Z REDIRECTION
CASE OFF
DIRECTION CHOICE OR CONTINUE
HARNESS DTP - MAINS
HARNESS DTP - MAINS
POWER UP SELF TEST
COVER - CONTROL AND FUSE
BURNER IGNITION
TRAP - C/W ELBOW - CONDENSATE
BURNER IGNITION
GAS INLET PRESSURE
NO BURNER IGNITION
COMBUSTION CONTROL UNIT
AIR INTAKE
AIR INTAKE
BURNER IGNITION
COMBUSTION CONTROL UNIT
BOILER NOISY
GAS INLET PRESSURE
BOILER NOISY
TRAP - C/W ELBOW - CONDENSATE
BOILER NOISEY
AIR INTAKE
FAULT CODE SENSORS
COMBUSTION CONTROL UNIT
FAULT CODE 2
KIT - SENSOR
FAULT CODE
KIT - SENSOR
STATUS CODE
Z REDIRECTION
FAULT CODE FAN
FAULT CODE RESET
FAN FAULT CODE 4
FAN
FAULT CODE MISCELLANEOUS
UNIT - PARAMETER
DIAGNOSTIC PROCEDURE
DIRECTION CHOICE OR CONTINUE
BURNER IGNITION
KIT - SENSOR
BURNER IGNITION
SWITCH - PRESSURE C/W O-RING
BURNER IGNITION
FAULT CODE RESET - OVERHEAT - FLUE STAT
BOILER SYS COOL
UNIT - PARAMETER
BOILER SYS COOL
GAS INLET PRESSURE
FAULT CODE MISC
FAULT/STATUS CODE MISCELLANEOUS
STATUS CODE SHUTDWN 2
CONTROLLER - USER INTERACTION
STAUS CODE COMMS
FAULT/STATUS CODE MISCELLANEOUS
STATUS CODE MISC
COMBUSTION CONTROL UNIT
BURNER IGNITION 2
SWITCH - PRESSURE C/W O-RING
STATUS CODE TEMP 2
PUMP
STATUS CODE TEMP 5
KIT - SENSOR
STATUS CODE TEMP 3
KIT - SENSOR
STATUS CODE TEMP
KIT - SENSOR
STATUS CODE TEMP 2
KIT - SENSOR
STATUS CODE TEMP 4
KIT - SENSOR
STATUS CODE TEMP 6
KIT - SENSOR
PWR UP SELF TEST
COMBUSTION CONTROL UNIT
LIMPET TEST
PUMP
FAULT CODE OVERHEAT
KIT - SENSOR
FAULT CODE OVERHEAT
SWITCH - PRESSURE C/W O-RING
FAULT CODE OVERHEAT 4
KIT - SENSOR
FAULT CODE OVERHEAT 3
KIT - SENSOR
FAULT CODE OVERHEAT 2
KIT - SENSOR
FAULT CODE OVERHEAT
FLUE
FAULT CODE OVERHEAT 2
SWITCH - PRESSURE C/W O-RING
STATUS CODE TEMP 4
PUMP
STATUS CODE TEMP 7
KIT - SENSOR
STATUS CODE TEMP 11
KIT - SENSOR
STATUS CODE TEMP 8
KIT - SENSOR
STATUS CODE TEMP 10
KIT - SENSOR
STATUS CODE TEMP 9
KIT - SENSOR
STATUS CODE TEMP 12
KIT - SENSOR
FAULT CODE OVERHEAT
PUMP
FAULT CODE OVERHEAT 8
KIT - SENSOR
FAULT CODE OVERHEAT 4
SWITCH - PRESSURE C/W O-RING
FAULT CODE OVERHEAT 7
KIT - SENSOR
FAULT CODE OVERHEAT 6
KIT - SENSOR
FAULT CODE OVERHEAT 5
KIT - SENSOR
FAULT CODE OVERHEAT 3
SWITCH - PRESSURE C/W O-RING
BOILER NOISY 2
GAS VALVE ASSEMBLY
BOILER NOISY
HEAT ENGINE FLUEWAYS
BOILER NOISY
FAN
GAS VALVE ADJUSTMENT
Z REDIRECTION
BOILER NOISY
INTERFACE - FLUE C/W SEAL
BOILER NOISY
INTERFACE SUMP
BURNER IGNITION
INTERFACE - FLUE C/W SEAL
BURNER IGNITION
INTERFACE SUMP
BURNER IGNITION
HEAT ENGINE FLUEWAYS
BURNER IGNITION 2
GAS VALVE ASSEMBLY
BOILER SYS COOL
COMBUSTION CONTROL UNIT
BOILER SYS COOL
INTERFACE - FLUE C/W SEAL
BOILER SYS COOL
INTERFACE SUMP
BOILER SYS COOL 2
COMBUSTION CONTROL UNIT
BOILER SYS COOL
HEAT ENGINE FLUEWAYS
BOILER SYS COOL
FAN
MODULATION
COMBUSTION CONTROL UNIT
PUMP DOES NOT RUN
PUMP
BURNER DOES NOT IGNITE & EST 2
COMBUSTION CONTROL UNIT
BURNER DOES NOT IGNITE & EST
SET - ELECTRODES C/W SCREW & GASKET
BURNER DOES NOT IGNITE & EST
INTERFACE - FLUE C/W SEAL
BURNER DOES NOT IGNITE & EST
INTERFACE SUMP
BURNER DOES NOT IGNITE & EST
HEAT ENGINE FLUEWAYS
BURNER DOES NOT IGNITE & EST
GAS VALVE ASSEMBLY
PARAMETER FAULT
FAULT CODE RESET
FAN DOES NOT RUN
FAN ELECTRICAL CONNECTIONS
FAN FAULT CODE
FAN ELECTRICAL CONNECTIONS
CHIMNEY ILLUMINATED SOLID
CONTROLLER - USER INTERACTION
FAN DOES NOT RUN
FAN OR COMBUSTION CONTROL UNIT
FAN RUNS
COMBUSTION CONTROL UNIT
FAN FAULT CODE
FAN OR COMBUSTION CONTROL UNIT
FAN FAULT CODE 2
COMBUSTION CONTROL UNIT
FUSE INVESTIGATION
COMBUSTION CONTROL UNIT FUSE INVESTIGATION
FAULT CODES
DIRECTION CHOICE OR CONTINUE
FUSE FURTHER INVESTIGATION
Z REDIRECTION
PWR UP SELF TEST
CONTROLLER - USER INTERACTION
BURNER IGNITION 3
GAS VALVE ASSEMBLY
FAULT CODE SENSOR
FAULT CODE RESET
FAULT CODE
HARNESS - CABLE 24V HE
FAULT CODE 2
HARNESS - CABLE 24V HE
STATUS CODE
DIRECTION CHOICE OR CONTINUE
FAN ROTATION
FAN
FAN FAULT CODE 2
FAN
FAN FAULT CODE 4
COMBUSTION CONTROL UNIT
FAN FAULT CODE 3
COMBUSTION CONTROL UNIT
FAN FAULT CODE
COMBUSTION CONTROL UNIT
FAULT CODE MISCELLANEOUS
FAULT CODE RESET
FAULT CODE MISCELLANEOUS
COMBUSTION CONTROL UNIT
BURNER IGNITION
HARNESS - CABLE 24V HE
STATUS CODE SHUT DWN
FAULT CODE RESET
STATUS CODE SHUTDWN
CONTROLLER - USER INTERACTION
STATUS CODE SHUTDWN
BL TERMINALS - LINK
STATUS CODE COMS
FAULT CODE RESET
STATUS CODE COMMS
COMBUSTION CONTROL UNIT
STATUS CODE MISC
FAULT CODE RESET
BURNER IGNITION 2
FLUE
STATUS CODE TEMP 2
COMBUSTION CONTROL UNIT
STATUS CODE TEMP
COMBUSTION CONTROL UNIT
STATUS CODE TEMP
STATUS CODE RESET - TEMP PROTECTION
STATUS CODE TEMP 3
COMBUSTION CONTROL UNIT
FAULT CODE OVERHEAT
COMBUSTION CONTROL UNIT
FAULT CODE OVERHEAT
HARNESS - CABLE 24V HE
FAULT CODE OVERHEAT
FAULT CODE RESET - OVERHEAT - FLUE STAT
FAULT CODE OVERHEAT 3
COMBUSTION CONTROL UNIT
FAULT CODE OVERHEAT 2
COMBUSTION CONTROL UNIT
STATUS CODE TEMP 4
COMBUSTION CONTROL UNIT
STATUS CODE TEMP 2
STATUS CODE RESET - TEMP PROTECTION
STATUS CODE TEMP 6
COMBUSTION CONTROL UNIT
STATUS CODE TEMP 5
COMBUSTION CONTROL UNIT
STATUS CODE TEMP
PUMP
FAULT CODE OVERHEAT 6
COMBUSTION CONTROL UNIT
FAULT CODE OVERHEAT 2
HARNESS - CABLE 24V HE
FAULT CODE OVERHEAT 2
FAULT CODE RESET - OVERHEAT - FLUE STAT
FAULT CODE OVERHEAT 5
COMBUSTION CONTROL UNIT
FAULT CODE OVERHEAT 4
COMBUSTION CONTROL UNIT
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAULT CODE (CHIMNEY SWEEP LED FLASHING RED)
CHARACTERISTIC TEST FROM POWER UP SELF TEST
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
ELECTRICAL CONNECTION - FAN MOTOR TO PCB POOR
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
ELECTRICAL CONNECTION - FAN MOTOR TO PCB POOR
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
CHIMNEY SWEEP LED ILLUMINATED (SOLID RED OR GREEN)
CHARACTERISTIC TEST FROM POWER UP SELF TEST
BURNER DOES NOT IGNITE & ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT IS BAFFLING AND/OR NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
FAN PULSES
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS
FAN SEIZED AND/OR ROTATION RESTRICTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
FAN RESISTANCE NOT AS EXPECTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS
FAN SEIZED AND/OR RESTRICTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
FAN RESISTANCE NOT AS EXPECTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
FAN RUNS
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - FAULT CODE
FAULT CODE 2 FLASHES RED OCCURS
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BOILER AND RADIATORS DO NOT REACH TEMPERATURE
CHARACTERISTIC TEST FROM CH OPERATION
BOILER UP TO TEMPERATURE, RADIATORS DO NOT HEAT SUFFICIENTLY
CHARACTERISTIC TEST FROM CH OPERATION
BOILER SHUTS DOWN OVERHEAT FAULT - 2 FLASHES RED OCCURS
CHARACTERISTIC TEST FROM CH OPERATION
DHW OPERATION UNSATISFACTORY
CHARACTERISTIC TEST FROM DHW OPERATION
DHW DEMAND NOT RECOGNISED
CHARACTERISTIC TEST FROM DHW OPERATION
NO CONNECTIONS - BL TERMINALS
CHARACTERISTIC TEST FROM INSPECTION BL TERMINALS - USER INTERFACE
EXTERNAL CONNECTIONS - BL TERMINALS
CHARACTERISTIC TEST FROM INSPECTION BL TERMINALS - USER INTERFACE
CONTROL PANEL LEDS DO NOT ILLUMINATE
CHARACTERISTIC TEST FROM POWER UP SELF TEST
BOILER GOES TO TEMPERATURE PROTECTION - FLOW TEMPERATURE BELOW 80°C
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
BOILER FLOW TEMPERATURE EXCEEDS 85°C AND STILL FIRED
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
BOILER SHUTS DOWN TEMP PROTECTION - 1 FLASH GREEN OCCURS EVERY 3 SECONDS
CHARACTERISTIC TEST FROM CH OPERATION
BOILER GOES TO OVERHEAT - FLOW TEMPERATURE BELOW 80°C
CHARACTERISTIC TEST FROM TEMPERATURE - RUN BOILER TO MAXIMUM
BOILER FLOW TEMPERATURE EXCEEDS 85°C AND STILL FIRED
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
BOILER GOES TO TEMPERATURE PROTECTION - FLOW TEMPERATURE BELOW 80°C
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
BOILER FLOW TEMPERATURE EXCEEDS 85°C AND STILL FIRED
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
STATUS CODE (CHIMNEY SWEEP LED FLASHING GREEN)
CHARACTERISTIC TEST FROM POWER UP SELF TEST
BOILER GOES TO OVERHEAT - FLOW TEMPERATURE BELOW 80°C
CHARACTERISTIC TEST FROM TEMPERATURE - RUN BOILER TO MAXIMUM
BOILER FLOW TEMPERATURE EXCEEDS 85°C AND STILL FIRED
CHARACTERISTIC TEST FROM TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
09/09/2021 13:21:16 2109_1_50_1 10/11/2021 15:57:42
11/10/2021 12:24:41
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
VOLTAGE PUMP AT PUMP
GAIN ACCESS TO PUMPS ELECTRICAL CONNECTIONS
VOLTAGE RECTIFICATION AT PCB
{GAINPCBACS}
CH TEMPERATURE CONTROL SET TO OFF POSITION
DISCONNECT SPARK ELECTRODE AT SPARK GENERATOR
DISCONNECT SPARK ELECTRODE LEAD FROM SPARK GENERATOR
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
FUSE FURTHER INVESTIGATION
THE INFORMATION PROV
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESET APPLIANCE - FAULT/STATUS CODE DISPLAYED
CH TEMPERATURE CONTROL SET TO OFF
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT LOCATED UNDERNEATH THE BOILER
RESET APPLIANCE - STATUS CODE DISPLAYED
CH TEMPERATURE CONTROL SET TO OFF
INSPECTION BL TERMINALS - USER INTERFACE
GAIN ACCESS TO THE USER CONTROL INTERFACE PCB, (USE INSULATION MAT AS REQUIRED)
RESET APPLIANCE - FAULT/STATUS CODE DISPLAYED
CH TEMPERATURE CONTROL SET TO OFF
INSPECTION WIRING HARNESS CONNECTIONS
{GAINPCBACS}
RESET APPLIANCE - STATUS CODE DISPLAYED
CH TEMPERATURE CONTROL SET TO OFF
OBSERVATION SYSTEM WATER
GAIN ACCESS TO SYSTEM AS REQUIRED
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE FAN ASSEMBLY
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
RESISTANCE SAFETY CIRCUIT AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
VOLTAGE PUMP AT PUMP
GAIN ACCESS TO PUMPS ELECTRICAL CONNECTIONS
OBSERVATION SYSTEM WATER
GAIN ACCESS TO SYSTEM AS REQUIRED
RESISTANCE SAFETY CIRCUIT AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
VOLTAGE PUMP AT PUMP
GAIN ACCESS TO PUMPS ELECTRICAL CONNECTIONS
COMBUSTION PERFORMANCE CHECK
CONNECT FGA TO THE COMBUSTION TEST POINT ON THE BOILER
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
ADJUSTMENT GAS VALVE
CONNECT FGA TO THE COMBUSTION TEST POINT ON THE BOILER
GAS VALVE ADJUSTED CORRECTLY
THE COMBUSTION READI
OBSERVATION SPARK GENERATOR
{GAINPCBACS}
REMOVE SPARK IGNITION LEAD FROM THE SPARK GENERATOR AND MAKE SAFE
INSPECTION ELECTRODE IGNITION
REMOVE SPARK ELECTRODE ASSEMBLY FROM THE BOILER
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - CH TEMPERATURE
DISCONNECT USER INTE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - CH TEMPERATURE
DISCONNECT USER INTE
VOLTAGE RECTIFICATION AT PCB - IGNITION
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE SPARK ELECTRODE ASSEMBLY FROM THE BOILER
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
RESISTANCE HARNESS PARAMETER UNIT
REMOVE CONNECTOR X5 FROM THE PCB
DISCONNECT ELECTRICAL CONNECTOR TO PARAMETER UNIT
RESET APPLIANCE - FAULT/STATUS CODE DISPLAYED
CH TEMPERATURE CONTROL SET TO OFF
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - CH TEMPERATURE
DISCONNECT USER INTE
VOLTAGE MAINS AT PCB
{GAINPCBACS}
RESISTANCE FUSE PCB
REMOVE FUSE FROM THE PCB
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT LOCATED UNDERNEATH THE BOILER
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT LOCATED UNDERNEATH THE BOILER
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR FROM THE GAS VALVE
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
RESET APPLIANCE - FAULT CODE
CH TEMPERATURE CONTROL SET TO OFF
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION FAN ROTATION & RESISTANCE
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
OBSERVATION FAN ROTATION & RESISTANCE
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
OBSERVATION FAN ROTATION & RESISTANCE - FAN PULSES
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
OBSERVATION FAN ROTATION & RESISTANCE - FAN PULSES
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
INSPECTION WIRING HARNESS CONNECTIONS
{GAINPCBACS}
RESISTANCE SAFETY CIRCUIT AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE SWITCH AIR PRESSURE
GAIN ACCESS TO AIR PRESSURE SWITCH AND DISCONNECT LEADS
OBSERVATION SYSTEM WATER
GAIN ACCESS TO SYSTEM AS REQUIRED
OBSERVATION SYSTEM WATER
GAIN ACCESS TO SYSTEM AS REQUIRED
DISCONNECT EXTERNAL BL CONNECTIONS
REMOVE EXTERNAL CONN
OPERATION AIR PRESSURE SWITCH
REMOVE AIR PRESSURE SWITCH AND DISCONNECT LEADS
OBSERVATION SYSTEM PUMP RUNNING
CH TEMPERATURE CONTROL SET TO OFF POSITION
LOCATE & GAIN ACCESS TO SYSTEM PUMP
RESET APPLIANCE - STATUS CODE - TEMPERATURE PROTECTION
ENSURE BOILER IS COOL
TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
ATTACH TEMPERATURE CLAMP TO FLOW PIPE
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
TEMPERATURE FLOW & RETURN DIFFERENTIAL
ENSURE BOILER IS COOL
ATTACH TEMPERATURE CLAMPS TO FLOW & RETURN PIPE
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
OBSERVATION SYSTEM WATER
GAIN ACCESS TO SYSTEM AS REQUIRED
VOLTAGE EXTERNAL CONTROLS
ATTACH A SOCKET & SEE TO THE ELECTRICAL TEST POINT
RESET APPLIANCE - FAULT CODE - OVERHEAT
ENSURE BOILER IS COOL
TEMPERATURE - RUN BOILER TO MAXIMUM
ATTACH TEMPERATURE CLAMP TO FLOW PIPE JUST ABOVE HEAT EXCHANGER
RESISTANCE SWITCH AIR PRESSURE
GAIN ACCESS TO AIR PRESSURE SWITCH AND DISCONNECT LEADS
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
OPERATION AIR PRESSURE SWITCH
REMOVE AIR PRESSURE SWITCH AND DISCONNECT LEADS
RESET APPLIANCE - STATUS CODE - TEMPERATURE PROTECTION
ENSURE BOILER IS COOL
TEMPERATURE PROTECTION - RUN BOILER TO MAXIMUM
ATTACH TEMPERATURE CLAMP TO FLOW PIPE
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
TEMPERATURE FLOW & RETURN DIFFERENTIAL
ENSURE BOILER IS COOL
ATTACH TEMPERATURE CLAMPS TO FLOW & RETURN PIPE
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
OBSERVATION SYSTEM PUMP RUNNING
CH TEMPERATURE CONTROL SET TO OFF POSITION
LOCATE & GAIN ACCESS TO SYSTEM PUMP
RESET APPLIANCE - FAULT CODE - OVERHEAT
ENSURE BOILER IS COOL
TEMPERATURE - RUN BOILER TO MAXIMUM
ATTACH TEMPERATURE CLAMP TO FLOW PIPE JUST ABOVE HEAT EXCHANGER
RESISTANCE SWITCH AIR PRESSURE
GAIN ACCESS TO AIR PRESSURE SWITCH AND DISCONNECT LEADS
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE MANIFOLDS
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
OPERATION AIR PRESSURE SWITCH
REMOVE AIR PRESSURE SWITCH AND DISCONNECT LEADS
System Information
- Total Tests: 404
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control