BAXI SOLO 2 PF
WARNING - IMPORTA
BAXI SOLO 2 PF
CASE REMOVAL
BOILER FROST PROTECTION
THERMOSTAT TURNED TO FROST POSITION
ENSURE THAT THE AMBIENT TEMPERATURE IS ABOVE 5 °C
PUMP RUNS
THERMOSTAT TURNED TO OFF POSITION
CORRECT BURNER GAS PRESSURE
THERMOSTAT TURNED TO MAX
CONNECT A U-GAUGE TO THE BURNER GAS PRESSURE TEST POINT
BURNER MODULATION
THERMOSTAT TURNED TO MAX
PUMP OVERRUN
NOTE: PUMP IS NOT AN INTEGRAL PART OF THE APPLIANCE
SO IT WILL BE ELSEWHERE ON THE SYSTEM
LOCKOUT RESET
DISCONNECT AN ORANGE LEAD FROM THE OVERHEAT THERMOSTAT
AND MAKE SAFE
DISPLAY
TURN THERMOSTAT TO MAX POSITION
DIAGNOSIS BY LIGHTS OR STEP BY STEP CONVENTION
PLEASE SELECT FROM O
DHW DEMAND
TURN THERMOSTAT TO M
BOILER ON AND PILOT ON NEON ILLUMINATED
CHARACTERISTIC TEST FROM DIAGNOSTIC DISPLAY
FAN RUNS
THERMOSTAT TO MAX POSITION
REMOVE COMBUSTION BOX DOOR
PILOT IGNITES
THERMOSTAT TURNED TO MAX
REFIT COMBUSTION BOX DOOR
BURNER IGNITES
THERMOSTAT TURNED TO MAX
CH OPERATION
THERMOSTAT SET TO MAXIMUM
DIAGNOSIS BY FUNCTIONAL SEQUENCE
NOT USED
BOILER FROST PROTECTION
POTENTIOMETER C/W LEADS HONEYWELL
BURNER IGNITES
KIT - PILOT IGNITION
FUSE
FUSE MAIN PCB F1
BOILER FROST PROTECTION
THERMOSTAT / SENSOR - HONEYWELL
ELECTRICAL SAFETY
ELECTRICAL SAFETY CHECKS
CORRECT BURNER PRESSURE
GAS VALVE INLET PRESSURE
BLOWN
MAINS FUSE
Z REDIRECTION
DIAGNOSTIC BY LIGHTS
Z REDIRECTION1
DIAGNOSTIC BY LIGHTS
SPARK ELECTRODE
KIT - PILOT IGNITION
INLET PRESSURE BURNER ON1
GAS VALVE INLET PRESSURE
VOLTAGE ABSENT PILOT SOLENOID
WIRE HARNESS VALVE - GAS VALVE
PILOT DOES NOT IGNITE
WIRE HARNESS VALVE - GAS VALVE
PILOT IGNITION1
SOLENOID PILOT - SOLO 2 PF
PILOT INJECTOR1
KIT - PILOT IGNITION
RECTIFICATION
KIT - PILOT IGNITION
RECTIFICATION
LEAD 410MM LONG - ELECTRODE
VOLTAGE ABSENT GAS VALVE
WIRE HARNESS VALVE - GAS VALVE
BURNER DOES NOT ESTABLISH
WIRE HARNESS VALVE - GAS VALVE
BURNER MODULATION
POTENTIOMETER C/W LEADS HONEYWELL
OPERATION
THERMOSTAT / SENSOR - HONEYWELL
CH OPERATION
POTENTIOMETER C/W LEADS HONEYWELL
GAS RATE
INJECTOR BURNER
LIMPET TEST
PUMP
BURNER MODULATION
THERMOSTAT / SENSOR - HONEYWELL
BOILER NOISY 2
THERMOSTAT / SENSOR - HONEYWELL
OC PILOT GAS VALVE
SOLENOID PILOT - SOLO 2 PF
BURNER IGNITES
GAS VALVE INLET PRESSURE
BOILER TO TEMP
PUMP
OVERHEAT
PUMP
PUMP OVERRUN OVERHEAT
PCB - CONTROL - HONEYWELL
OVERHEAT
THERMOSTAT / SENSOR - HONEYWELL
SPARK ELECTRODE LEAD
LEAD 410MM LONG - ELECTRODE
PILOT DOES NOT IGNITE
FAN ASSEMBLY
AIR PRESSURE SENSING TUBE CONNECTING PIECE
TUBE - FLEXIBLE
AIR PRESSURE SENSING PIPE
SENSING HEAD
PILOT DOES NOT IGNITE
HEAT EXCHANGER
PILOT ON NEON
PRESSURE SWITCH - YAMATAKE
APS PROVING
COUPLINGS M-F BOILER HARNESS
OH OC NEON DIAG
KIT - OVERHEAT THERMOSTAT - SOLO PF
PUMP OVERRUN
PCB - CONTROL - HONEYWELL
OVERHEAT
HARNESS ASSEMBLY - BOILER
BLOWNPUMP
MAINS FUSE
PUMP
FUSE MAIN PCB F1
LOCKOUT RESET
POTENTIOMETER C/W LEADS HONEYWELL
FAN VOLTAGE ABSENT
COUPLINGS M-F BOILER HARNESS
AIR PRESSURE SENSING TUBE CONNECTING PIECE 2
TUBE - FLEXIBLE
AIR PRESSURE SENSING PIPE 2
SENSING HEAD
APS NO AIR RESISTANCE
COUPLINGS M-F BOILER HARNESS
OVERHEAT FURTHER INVESTIGATION
ZREDIRECTS BY HMTL LINK
PILOT GAS VALVE OC
SOLENOID PILOT - SOLO 2 PF
FAN ON NEON (GREEN)
POTENTIOMETER C/W LEADS HONEYWELL
BOILER NEON ON ONLY
POTENTIOMETER C/W LEADS HONEYWELL
FAN ON NEON (GREEN)
THERMOSTAT / SENSOR - HONEYWELL
FAN NEUTRAL
COUPLINGS M-F BOILER HARNESS
FUNCTIONAL SEQUENCE
DIAGNOSTIC BY LIGHTS
NO FAN
FUSE MAIN PCB F1
BOILER ON NEON
PCB - CONTROL - HONEYWELL
BOILER FROST PROTECTION
PCB - CONTROL - HONEYWELL
CORRECT BURNER GAS PRESSURE
GAS VALVE
PUMP
PUMP
BROKEN NEUTRAL 1
NEUTRAL FAULT
PUMP RUNS( NEUTRAL TRACK)
PCB - CONTROL - HONEYWELL
NEUTRAL BROKEN 2
NEUTRAL FAULT
FAULT
WIRING FAULT TO PUMP
PILOT GAS VALVE LIVE1
PCB - CONTROL - HONEYWELL
NEUTRAL PILOT SOLENOID
PCB - CONTROL - HONEYWELL
MECHAN1
GAS VALVE
VOLTAGE ABSENT GAS VALVE
PCB - CONTROL - HONEYWELL
BURNER IGNITES
PCB - CONTROL - HONEYWELL
BURNER MODULATION
PCB - CONTROL - HONEYWELL
HEAT EXCHANGER 2
HEAT EXCHANGER ASSEMBLY
INSUFFICIENT HEAT
PCB - CONTROL - HONEYWELL
BOILER ON PILOT ON NEONS FAULT
PCB - CONTROL - HONEYWELL
GASVALVE HARNESS DAMAGE
WIRE HARNESS VALVE - GAS VALVE
BURNER INJECTOR
INJECTOR BURNER
BURNER IGNITES
GAS VALVE
OVERHEAT
PCB - CONTROL - HONEYWELL
RETEST APPLIANCE
NORMAL OPERATION
FLUE
FLUE
PILOT DOES NOT IGNITE
PCB - CONTROL - HONEYWELL
APS PROVING
HARNESS ASSEMBLY - BOILER
OVER HEAT FAULT
PCB - CONTROL - HONEYWELL
BROKEN NEUTRAL 1PUMP
NEUTRAL FAULT
PUMP RUNS
PCB - CONTROL - HONEYWELL
LOCKOUT RESET
PCB - CONTROL - HONEYWELL
FAN
FAN ASSEMBLY
FAN VOLTAGE ABSENT
HARNESS ASSEMBLY - BOILER
FAN ON NEON (GREEN)
PRESSURE SWITCH - YAMATAKE
APS NO AIR RESISTANCE
HARNESS ASSEMBLY - BOILER
OVERHEAT NO FAN VOLTAGE
HARNESS ASSEMBLY - BOILER
VOLTAGE ABSENT FAN
WIRE HARNESS VALVE - GAS VALVE
NO VOLTAGE FAN THERMISTOR
HARNESS ASSEMBLY - BOILER
FAN RUNS ( NEUTRAL TRACK)
PCB - CONTROL - HONEYWELL
FAN NEUTRAL
HARNESS ASSEMBLY - BOILER
FAN ON NEON (GREEN)
PCB - CONTROL - HONEYWELL
RECTIFICATION
PCB - CONTROL - HONEYWELL
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
NOISY OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
BOILER TO TEMP RADS COOL
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
BOILER DOES NOT REACH TEMP - SYSTEM COOL
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE PRESENT AT BOTH TEST POINTS (NEUTRAL FAULT)
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
MAINS VOLTAGE ABSENT BOTH TEST POINTS
CHARACTERISTIC TEST FROM PUMP VOLTAGE AT PUMP (CH DEMAND)
04/01/2018 12:12:31 1809_1_50_1 23/11/2018 12:32:18
09/11/2018 08:36:14
PUMP VOLTAGE AT PCB (CH DEMAND)
{GAINPCBACS}
THERMOSTAT TO MAX POSITION
INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT ON GAS VALVE
SPARKING PRESENT
THERMOSTAT TURNED TO MAXIMUM
SPARK TEST
REMOVE THE COMBUSTIO
DOES SPARKING CEASE
BOILER THERMOSTAT TO MAX POSITION
THERMOSTAT POTENTIOMETER MODULATION RESISTANCE
DISCONNECT THE THERMOSTAT MULTIPLUG FROM THE PCB
MAINS POWER POLARITY
{GAINPCBACS}
THERMOSTAT ON RESISTANCE
DISCONNECT THE THERM
GAS VALVE PILOT SOLENOID RESISTANCE
DISCONNECT ONE OF THE LEADS FROM THE PILOT GAS VALVE
INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT ON GAS VALVE
BOILER RESET- OVERHEAT FURTHER INVESTIGATION
NOTE: ENSURE BOILER IS COOL
RESISTANCE OVERHEAT THERMOSTAT
DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT THERMOSTAT
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
INSPECTION FAN
DISCONNECT THE 5-PIN
THERMOSTAT ON/OFF RESISTANCE
DISCONNECT THE THERM
FAN VOLTAGE
THERMOSTAT TURNED TO MAX
PCB SWITCHED LIVE (INPUT)
{GAINPCBACS}
THERMOSTAT TO OFF POSITION
OVERHEAT THERMOSTAT
DISCONNECT ONE OF THE ORANGE LEADS FROM THE OVERHEAT THERMOSTAT
GAS VALVE PILOT SOLENOID RESISTANCE
DISCONNECT ONE OF THE LEADS FROM THE PILOT GAS VALVE
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
PUMP VOLTAGE AT PUMP (CH DEMAND)
GAIN ACCESS TO PUMP ELECTRICAL CONNECTIONS
THERMOSTAT TO OFF POSITION
FUSE RESISTANCE (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
RESISTANCE GAS VALVE PILOT SOLENOID AND HARNESS
DISCONNECT THE GAS VALVE CONNECTOR FROM THE PCB (3-PIN CONNECTOR)
INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT ON GAS VALVE
PILOT GAS VALVE LIVE
GAIN ACCESS TO GAS VALVE CONNECTIONS
THERMOSTAT TURNED TO MAX
GAS VALVE PILOT SOLENOID RESISTANCE
DISCONNECT ONE OF THE LEADS FROM THE PILOT GAS VALVE
CONTINUITY PILOT SOLENOID HARNESS
DISCONNECT THE GAS VALVE CONNECTOR FROM THE PCB
(3-PIN CONNECTOR)
CONTINUITY PILOT SOLENOID HARNESS
DISCONNECT THE GAS VALVE CONNECTOR FROM THE PCB
(3-PIN CONNECTOR)
PILOT INJECTOR
THE PILOT INJECTOR C
MAIN GAS VALVE LIVE
GAIN ACCESS TO GAS VALVE CONNECTIONS
THERMOSTAT SET TO MAX
BURNER GAS PRESSURE
THERMOSTAT TURNED TO MAXIMUM
CONNECT A U-GAUGE TO THE BURNER GAS PRESSURE TEST POINT
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
CONTINUITY MAIN GAS VALVE SOLENOID HARNESS
DISCONNECT GAS VALVE CONNECTOR FROM THE PCB
(3-PIN CONNECTOR)
CONTINUITY MAIN GAS VALVE SOLENOID HARNESS
DISCONNECT GAS VALVE CONNECTOR FROM THE PCB
(3-PIN CONNECTOR)
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
THERMOSTAT POTENTIOMETER MODULATION RESISTANCE
DISCONNECT THE THERMOSTAT MULTIPLUG FROM THE PCB
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
RUN BOILER TO MAX TEMP-DOES OVERHEAT OCCUR
ATTACH TEMPERATURE CLAMP TO FLOW PIPE
SET BOILER TEMPERATURE CONTROL TO MAXIMUM
PUMP OVERRUN
NOTE: PUMP IS NOT AN INTEGRAL PART OF THE APPLIANCE
SO IT WILL BE ELSEWHERE ON THE SYSTEM
FAN PRESSURE
DISCONNECT THE 5-PIN
AIR PRESSURE SWITCH PROVING
DISCONNECT THE 5-PIN
AIR PRESSURE SENSING PIPE
REMOVE AIR PRESSURE TUBE (VENTURI) CONNECTED BETWEEN FAN AND AIR PRESSURE SWITCH
CONTINUITY AIR PRESSURE SWITCH HARNESS
DISCONNECT THE FAN - AIR PRESSURE SWITCH CONNECTOR
FROM THE PCB (5PIN - CONNECTOR)
RESISTANCE OVERHEAT LOOM
DISCONNECT OVERHEAT CONNECTOR FROM PCB
DISCONNECT CONNECTIONS TO OVERHEAT STAT
THERMOSTAT SENSOR RESISTANCE
REMOVE THE YELLOW SPADED WIRES FROM THE THERMOSTAT SENSOR.
FUSE RESISTANCE (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
PCB FUSE
GAIN ACCESS TO PCB ASSEMBLY
CONTINUITY FAN HARNESS
DISCONNECT 5-PIN CONNECTOR FROM PCB
RESISTANCE AIR PRESSURE SWITCH NO AIR AND HARNESS
DISCONNECT THE 5-PIN CONNECTOR FROM THE PCB
RESISTANCE OVERHEAT THERMOSTAT AND HARNESS
DISCONNECT THE OVERHEAT CONNECTOR FROM THE PCB (ORANGE LEADS)
AIR PRESSURE SENSING PIPE
REMOVE AIR PRESSURE TUBE (VENTURI) CONNECTED BETWEEN FAN AND AIR PRESSURE SWITCH
RESISTANCE GAS VALVE PILOT SOLENOID AND HARNESS
DISCONNECT THE GAS VALVE CONNECTOR FROM THE PCB (3-PIN CONNECTOR)
THERMOSTAT ON RESISTANCE
DISCONNECT THE THERM
PCB FUSE
GAIN ACCESS TO PCB ASSEMBLY
THERMOSTAT POTENTIOMETER RESISTANCE
DISCONNECT THE THERMOSTAT MULTIPLUG FROM THE PCB.
RESISTANCE THERMOSTAT SENSOR AND HARNESS
DISCONNECT THE THERMISTOR CONNECTOR FROM THE PCB (YELLOW LEADS)
PCB FUSE
GAIN ACCESS TO PCB ASSEMBLY
PILOT INJECTOR
THE PILOT INJECTOR C