Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Gain access to gas valve connections
Thermostat turned to Max
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow the Fan to start.
Test 1:
Measure the voltage across the live (orange lead) and the Earth terminal on the main connector block at the front of the control box.
Test 2:
Measure the voltage across the neutral (blue lead) and the Earth terminal on the main connector block at the front of the control box.