Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
LOGIC+ WITH PLASTIC HYDROBLOCK & 2 THERMISTORS
GLOBALLY REPLACED
OBSERVATION DISPLAY OPERATES
SELECTOR SWITCH IN HEATING & HOT WATER POSITION
ENSURE THERE IS NO DEMAND FOR EITHER CH OR DHW
OBSERVATION PUMP & FAN RUNS DHW DEMAND
SELECTOR SWITCH TO HOT WATER POSITION
DHW TEMPERATURE CONTROL SET TO MAX
PREHEAT OFF
HOT WATER OPERATION
PREHEAT OFF
OBSERVATION BURNER IGNITES AND ESTABLISHES DHW DEMAND
DHW TEMPERATURE CONTROL SET TO MAX
PREHEAT OFF
OPERATION CH
PREHEAT OFF
CH TEMPERATURE CONTROL SET TO MAXIMUM
OBSERVATION PUMP AND FAN OVER RUN
PREHEAT OFF
APPLY A DEMAND FOR HEATING OR HOT WATER
LOW WATER PRESSURE FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
FLOW THERMISTOR FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
RETURN THERMISTOR FAULT CODE HEADER
HEADER FOR FAULT CODE OK TO BE BLANK
FAULT 8 FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
BOILER CHIP CARD FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
OBSERVATION BOILER REACTS TO CH DEMAND
SELECTOR SWITCH TO HEATING AND HOT WATER POSITION
FURTHER INVESTIGATION FUSES
OK TO BE BLANK
LOW MAINS VOLTAGE FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
TOO MANY RESETS FAULT CODE HEADER
HEADER FOR FAULT CODE OK TO BE BLANK
FLOW / RETURN REVERSED FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
NO WATER FLOW LOCKOUT AND OVERHEAT LOCKOUT HEADER
HEADER FOR FAULT CODE - NOT USED
FLAME LOSS FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
NEW QADAI OPTIONS
OUTSIDE MODEL
OBSERVATION SELF CHECK AND STANDBY
{ALLDEMANDOFF}
SELECTOR SWITCH IN DHW & CH POSITION
FAN FAULT CODE HEADER
HEADER FOR FAULT CODE - NOT USED
OUTSIDE SENSOR FAULT CODE HEADER
HEADER FOR FAULT CODE OK TO BE BLANK
PCB FAULT CODE HEADER
HEADER FOR FAULT CODE OK TO BE BLANK
HEADER FOR PCB COMPONENT ON STARTUP
OK TO BE BLANK
HEADER FOR DIVERTER VALVE REFITTING PROCEDURE
OK TO BE BLANK
PREHEAT SATISFACTORY3
KIT - PCB L10 - PRIMARY
FAULT CODES
Z DIRECTION
F4 - FLOW SENSOR FAULT
THERMISTOR - NO FLOW
F5 - RETURN SENSOR FAULT
CONTROL THERMISTOR (RETURN)
L6 FAULT CODE
ELECTRODE - DETECTION
PUMP SU FAN RUNS SPARKING DOES NOT OCCURTEMP
KIT - PCB L10 - PRIMARY
C2 BCC ERROR
KIT - PCB L10 - PRIMARY
CASE REMOVAL
Z DIRECTION
TO DIVERTER - RADS NOT POOR HOT WATER
HARNESS - WIRING - MAINS
BOILER TO TEMP RADS COOL
KIT - PUMP HEAD
DHW NOISEY KETTLING
KIT - SIPHON TRAP
CH OPERATION BOILER NOISY
THERMISTOR - NO FLOW
WONT RESET L5
KIT - PCB L10 - PRIMARY
FA
KIT - PUMP HEAD
FAULT CODE FA
CONTROL THERMISTOR (RETURN)
FAULT CODE FA
THERMISTOR - NO FLOW
FLOW RATE
COLD WATER SUPPLY
CALIBRATION LOW BOILER TEMP LOW OPERATION DHW DHW COOL RADS COLD NO CH DEMAND
THERMISTOR - NO FLOW
DHW COOL RADS COOL
CONTROL THERMISTOR (RETURN)
BOILER TEMP LOW SYSTEM TEMP LOWOPERATION DHW DHW COOL RADS COOL
GAS INLET PRESSURE
F1 - LOW WATER FAULT
SYSTEM PRESSURE
F1 LOW WATER FAULT
KIT - PRESSURE GAUGE
FAULT CODE L3
SYSTEM PRESSURE
L3 NO WATER FLOW
KIT - PRESSURE GAUGE
BOILR SHUTS DOWN PREMATURELY CHOPERATION
KIT - PUMP HEAD
CH OPERATION BOILER NOISY
CONTROL THERMISTOR (RETURN)
CALIBRATION LOW BOILER TEMP LOW SYSTEM TEMP LOW
THERMISTOR - NO FLOW
CALIBRATION LOW BOILER TEMP LOW SYSTEM TEMP LOW
CONTROL THERMISTOR (RETURN)
LOW GAS RATE CH OPERATION
INJECTOR ASSEMBLY
VOLTS TO TURBINE (DHW BURNER IGN) 2
KIT - PCB L10 - PRIMARY
TO FLOW SWITCH - NO HOT WATER DEMAND
HARNESS - WIRING - SELV
F2 FAULT CODE
GAS INLET PRESSURE
F2 FAULT CODE
FLUE
F2 FAULT CODE
ELECTRODE - DETECTION
F2 FAULT CODE
KIT - SIPHON TRAP
F2 FAULT CODE
KIT - BURNER
F2 FAULT CODE
ELECTRODE - IGNITION
F2 FAULT CODE
KIT - HEAT ENGINE
F2 FAULT CODE
INJECTOR ASSEMBLY
F2 FAULT CODE
KIT - GAS VALVE
PREHEAT SATISFACTORY3
KIT - BODY - DIVERTER VALVE C/W PADDLE
DHW COOL RADS COOL
KNOB WHITE - POTENTIOMETERS
FAN RUNS CH DEMAND
KNOB WHITE - POTENTIOMETERS
CH BOILER TEMP LOW SYSTEM TEMP LOW
KNOB WHITE - POTENTIOMETERS
L6 - STICKING OPEN
KIT - GAS VALVE
L6 FAULT CODE
KIT - PCB L10 - PRIMARY
L1 - OVERHEAT FAULT
THERMISTOR - NO FLOW
L1 - OVERHEAT FAULT
CONTROL THERMISTOR (RETURN)
L1 OR L3 FAULT
THERMISTOR - NO FLOW
L1 OR L3 FAULT
CONTROL THERMISTOR (RETURN)
NO VOLTAGE TO DIVERTER (QADAI)
KIT - PCB L10 - PRIMARY
INCORRECT RESISTANCE (QADAI)
MOTOR DIVERTER VALVE
NO VOLTAGE TO SPARK GEN (QADAI)
KIT - PCB L10 - PRIMARY
INCORRECT RESISTANCE (QADAI)
UNIT - IGNITOR
NO FAN AT START UP QADAI
KIT - PCB L10 - PRIMARY
TO FAN POWER - PUMP SHORT TIME START UP QADAI
HARNESS - WIRING - MAINS
INCORRECT RESISTANCE (QADAI)
KIT - FAN
NO POWER TO PUMP (QADAI)
KIT - PCB L10 - PRIMARY
INCORRECT RESISTANCE (QADAI)
KIT - PUMP HEAD
RESISTANCE WRONG (QADAI)
KIT - GAS VALVE
NO POWER TO GAS VALVE (QADAI)
KIT - PCB L10 - PRIMARY
QADAI
THERMISTOR - NO FLOW
BLANK FOR QUICK ACCESS DATA AND INFORMATION
Z DIRECTION
BLANK FOR DIAGNOSTICS LITE 2
Z DIRECTION
QADAI
CONTROL THERMISTOR (RETURN)
PUMP RUNS DHW DEMAND
HARNESS (MAIN) - ERP PUMP HARNESS
NO PUMP AT STATR UP2
HARNESS - WIRING - MAINS
L1
PACK - CH FLOW / PACK - RETURN CH
INCORRECT RESISTANCE ERP (QADAI)
KIT - PUMP HEAD
OBSERVATION DISPLAY AND SELF CHECK - NO VOLTAGE TO DISPLAY
KIT - PCB L10 - PRIMARY
OBSERVATION DISPLAY AND SELF CHECK - NO DISPLAY
HARNESS - CUI TO PRIMARY
BLOWN STAND BY MODE AT POWER UP
FUSE - MAINS
OBSERVATION DISPLAY AND SELF CHECK - NO DISPLAY - FROM BLOCK TO PCB
HARNESS - WIRING - MAINS
BLOWN STANDBY MODE AT POWER UP
FUSE- PCB
PCB DAMAGED
KIT - PCB L10 - PRIMARY LEAK OR SHORT
OBSERVATION DISPLAY AND SELF CHECK - NO VOLTAGE TO DISPLAY PARTIAL DISPLAY
KIT - PCB L10 - PRIMARY
OBSERVATION DISPLAY AND SELF CHECK - NO DISPLAY PARTIAL DISPLAY
HARNESS - CUI TO PRIMARY
TO FAN POWER - PUMP SHORT TIME START UP
HARNESS - WIRING - MAINS
NO FAN AT START UP
KIT - PCB L10 - PRIMARY
NO FAN AT START UP
HARNESS - WIRING - SELV
FAN DOES NOT RUN
HARNESS - WIRING - MAINS
NOT RESPONDING TO HEATING - LINKEDPUMP SU FAN RUNS SPARKING DOES NOT OCCUR
KIT - PCB L10 - PRIMARY
POWER UP - PUMP DOES NOT RUN
HARNESS (MAIN) - ERP PUMP HARNESS
POWER UP - PUMP DOES NOT RUN NO PUMP AT STATR UP2
HARNESS - WIRING - MAINS
FIRES WITH NO DEMAND
FROST PROTECTION (INTERNAL)
POWER UP
OPEN TAP OR LEAK
POWER UP
KIT - FLOW SENSOR C/W TURBINE
BOILER FIRES WITH NO DEMAND
KNOB WHITE - POTENTIOMETERS
POOR FLOW RATE
PACK - DHW
FOR TYPE DIAG PROCEDURE
Z DIRECTION
FAN DOES NOT RUN QADAI
KIT - FLOW SENSOR C/W TURBINE
FAN RUNS DHW DEMAND
KNOB WHITE - POTENTIOMETERS
DHW POT FAULTY
KIT - CUI BOARD
FAN RUNS DHW
THERMISTOR - NO FLOW
SENSOR TEMP RETURN FAN RUNS
HARNESS - WIRING - SELV
BURNER IGNITES AND ESTABLISHES - NO SPARKING
THERMISTOR - NO FLOW
BURNER IGNITES AND ESTABLISHES - NO SPARKING
CONTROL THERMISTOR (RETURN)
SPARKING OCCURS BURNER DOES NOT IGNITE
HARNESS - WIRING - MAINS
SPARKING OCCURS BURNER DOES NOT IGNITE
LEAD - IGNITION
BURNER DOES NOT IGNITE
KIT - SIPHON TRAP
VOLTAGE TO GAS VALVE
KIT - PCB L10 - PRIMARY
BURNER DOES NOT IGNITE
INJECTOR ASSEMBLY
BURNER DOES NOT IGNITE
KIT - BURNER
BURNER DOES NOT IGNITE
KIT - HEAT ENGINE
NEW MODELBLOCKED OR DAMAGED
KIT - BURNER
SPARKING BUT NO LIGHTING
KIT - HEAT ENGINE
BURNER IGNITES BUT DOES NOT ESTABLISH
GAS INLET PRESSURE
BURNERIGNITES
HARNESS - DETECTION LEAD
BURNER IGNITES
ELECTRODE - DETECTION
BURNER IGNITES BUT DOES NOT ESTABLISH
KIT - BURNER
DOES NOT ESTABLISH
ELECTRODE - IGNITION
BURNER IGNITES BUT BAFFLES OUT OR IS NOISY
KIT - SIPHON TRAP
BURNER DOES NOT IGNITE - BAFFLES
GAS INLET PRESSURE
BURNER BAFFLES OR NOISY
INJECTOR ASSEMBLY
MECHANICAL PHYSICAL OPERATION
KIT - FAN
NEW MODEL FLUEWAYS
KIT - HEAT ENGINE
IGNITES BUT BAFFLES OR NOISY
KIT - BURNER
DHW NOISY
INTERNAL BYPASS
DHW COOL RADS COOL
KIT - HEAT ENGINE
DHW OPERATION BOILER NOISY
THERMISTOR - NO FLOW
DHW OPERATION BOILER NOISY
CONTROL THERMISTOR (RETURN)
DHW OPERATION BOILER NOISY
KIT - PUMP HEAD
DHW RUNS HOT COLD
INTERNAL BYPASS
NOT RESPONDING TO CH 4
KIT - CUI BOARD
CH UP TEMP RADS COLD
PACK - CH FLOW / PACK - RETURN CH
RADS COLD BOILER HOT
KIT - BODY - DIVERTER VALVE C/W PADDLE
RADS COLD BOILER HOT
KIT - PCB L10 - PRIMARY
RADS COLD BOILER HOT
HARNESS - WIRING - MAINS
BLANK FOR L1 FAULT CODE 2
Z DIRECTION
PREHEAT SATISFACTORY4
KIT - PCB L10 - PRIMARY
TO DIVERTER - RADS NOT POOR HOT WATER2
HARNESS - WIRING - MAINS
RADS COLD BOILER HOT 2
KIT - PCB L10 - PRIMARY
RADS COLD BOILER HOT2
HARNESS - WIRING - MAINS
FAULT CODE L3
KIT - BODY - DIVERTER VALVE C/W PADDLE
NO PUMP AT START UP2 L1
KIT - PCB L10 - PRIMARY
L1
HARNESS (MAIN) - ERP PUMP HARNESS
NO PUMP AT STATR UP2 L1
HARNESS - WIRING - MAINS
FO-L3 - NO FLOW FAULT - STICKING
KIT - PUMP HEAD
FAULT CODE L3
KIT - HEAT ENGINE
TO LWPS F1 - LOW WATER FAULT
HARNESS - WIRING - SELV
F1 - LOW WATER FAULT
SWITCH - PRESSURE - WATER
F3 - NEUTRAL FAULT
HARNESS - WIRING - MAINS
F2 NO CONTROL VOLTAGE
KIT - PCB L10 - PRIMARY
F3 FAN CONTROL
HARNESS - WIRING - SELV
F3 - FAN HARNESS
HARNESS - WIRING - MAINS
F6
OUTDOOR SENSOR
F9
Z DIRECTION
STUCK ON STARTUP
KIT - PCB L10 - PRIMARY
PUMP RUNS
REGULATOR - FLOW
FURTHER INVESTIGATION FUSE F1ERP PUMP
KIT - PUMP HEAD
FURTHER INVESTIGATION FUSE F1ERP PUMP
KIT - FAN
FURTHER INVESTIGATION FUSE F1ERP PUMP
UNIT - IGNITOR
FURTHER INVESTIGATION FUSE F1
KIT - PUMP HEAD
FURTHER INVESTIGATION FUSE F1
KIT - FAN
FURTHER INVESTIGATION FUSE F1
UNIT - IGNITOR
F6 FAN RUNS DHW DEMAND - NO FAN
KIT - PCB L10 - PRIMARY
NOT RESPONDING TO CH 1
KIT - PCB L10 - PRIMARY
OPERATION CH RADIATORS COOL
OUTDOOR SENSOR
NO VOLTAGE TO DIVERTER (QADAI) CH
KIT - PCB L10 - PRIMARY
TO GASVALVE - FURTHER INVESTIGATION FUSE F1
HARNESS - WIRING - MAINS
TO GASVALVE - FURTHER INVESTIGATION FUSE F1ERP PUMP
HARNESS - WIRING - MAINS
FAN RUNS DHW DEMAND - PUMP RUNNING CONTINUALLY (QADAI)
KIT - PCB L10 - PRIMARY
TO DIVERTER - FURTHER INVESTIGATION FUSE F1
HARNESS - WIRING - MAINS
TO DIVERTER - FURTHER INVESTIGATION FUSE F1ERP PUMP
HARNESS - WIRING - MAINS
DIVERTER VALVE REFIITING
Z DIRECTION
FURTHER INVESTIGATION FUSE ERP PUMP
KIT - PUMP HEAD
DHW COLD RADS COLD
INTERNAL BYPASS
L1 L3
INTERNAL BYPASS
RESTRICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND
INJECTOR ASSEMBLY
RESTICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND
KIT - SIPHON TRAP
LOW SYSTEM TEMP POTOPERATION DHW DHW COOL RADS COLD NO CH DEMAND
KIT - CUI BOARD
GAS VALVE FILTER RESTRICTED
KIT - GAS VALVE
POOR GAS RATE
KIT - BURNER
RESTRICTED OPERATION DHW DHW DOOL RADS COLD NO CH DEMAND
KIT - HEAT ENGINE
RESTRICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND LPG
INJECTOR ASSEMBLY
RESTICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND LPG
KIT - SIPHON TRAP
GAS VALVE FILTER RESTRICTED LPG
KIT - GAS VALVE
POOR GAS RATE LPG
KIT - BURNER
RESTRICTED OPERATION DHW DHW DOOL RADS COLD NO CH DEMAND LPG
KIT - HEAT ENGINE
DHW COOL RADS COOL LPG
EXTERNAL HOT WATER FAULT
FAULT CODE IN TREE 2
Z DIRECTION
F2 BURNERIGNITES
HARNESS - DETECTION LEAD
L6 BURNERIGNITES
HARNESS - DETECTION LEAD
DHW TOO HOT
KNOB WHITE - POTENTIOMETERS
NO CH DEMAND 1
PLUG - TIMER LINK
NOT RESPONDING TO CH 8
KIT - CUI BOARD
NO CH DEMAND 1
INTERNAL TIMER
NOT RESPONDING TO CH 3
KIT - CUI BOARD
REACTS TO CH DEMAND
OUTDOOR SENSOR
UP TO TEMP RADS COLD
INTERNAL BYPASS
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO IGNITION - TO GAS VALVE
HARNESS - WIRING - MAINS
VOLTAGE TO GAS VALVE
KIT - THERMOSTAT
BLANK FOR RESET PAGE
Z DIRECTION CHOICE OR CONTINUE
QADAI
OUTDOOR SENSOR
ON WITH NO DEMAND - FROST
THERMISTOR - NO FLOW
FIRING NO DEMAND
CONTROL THERMISTOR (RETURN)
EXTERNAL FROST PROTECT
EXTERNAL FROST PROTECT
UNDER PRESSURE
KIT - EXPANSION VESSEL
BOILER TEMP LOW SYSTEM TEMP LOW
GAS INLET PRESSURE
HOT WATER CYCLING
CONTROL THERMISTOR (RETURN)
TEMPERATURE CONTROL DHW
KIT - CUI BOARD
BLOCKED PREHEAT SAT3
KIT - PLATE HEAT EXCHANGER
HOT WATER CYCLING
THERMISTOR - NO FLOW
NO OVERRUNS
KIT - PCB L10 - PRIMARY
HOT WATER TOO HOT
CONTROL THERMISTOR (RETURN)
HOT WATER TOO HOT
THERMISTOR - NO FLOW
PREHEAT SATISFACTORY3
MOTOR DIVERTER VALVE
TO FLOW SENSOR F4 - FLOW SENSOR FAULT
HARNESS - WIRING - SELV
F4 - FLOW SENSOR FAULT
KIT - PCB L10 - PRIMARY
TO RETURN SENSOR F5 - RETURN SENSOR FAULT
HARNESS - WIRING - SELV
F5 - RETURN SENSOR FAULT
KIT - PCB L10 - PRIMARY
C2 BCC ERROR
Z DIRECTION
CH OPERATION NOISY
KIT - HEAT ENGINE
LETBY PREHEAT3
KIT - BODY - DIVERTER VALVE C/W PADDLE
FALSE LOW VOLTAGE
KIT - PCB L10 - PRIMARY
L5 - RESTART FAULT CODES
Z DIRECTION
FAULT CODE FA
HARNESS - WIRING - SELV
FAULT CODE FA - FLOW SENSOR
HARNESS - WIRING - SELV
POOR FLOW - RESTRICTED
KIT - PLATE HEAT EXCHANGER
DHW COOL RADS COOL
EXTERNAL HOT WATER FAULT
FAULT CODE FA
KIT - PCB L10 - PRIMARY
POTENTIOMETER TEMP CONTROL CH OP BOILER NOISY 2
KIT - CUI BOARD
FAN DOES NOT RUN
KIT - FLOW SENSOR C/W TURBINE
F2 FAULT CODE
KIT - PCB L10 - PRIMARY
BLANK FOR L6 FAULT CODE RESET
Z DIRECTION
STOPPING PRESEQ BREAKING
Z DIRECTION
DIVERTER VOLTAGE SATISFACTORY
RESULT AS EXPECTED
DIVERTER RESISTANCE SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR VOLTAGE SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR SATISFACTORY
RESULT AS EXPECTED
FAN SPEED CONTROL VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FAN VOLTAGE SATISFACTORY
RESULT AS EXPECTED
NO MAINS TO FAN AT START UP QADAI
KIT - PCB L10 - PRIMARY
ELECTRICAL OVER 15V ON N QADAI
KIT - FAN
FAN RESISTANCE SATISFACTORY
RESULT AS EXPECTED
PUMP VOLTAGE SATISFACTORY
RESULT AS EXPECTED
PUMP RESISTANCE SATISFACTORY
RESULT AS EXPECTED
GAS VALVE RESISTANCE SATISFACTORY
RESULT AS EXPECTED
GAS VALVE VOLTAGE SATISFACTORY
RESULT AS EXPECTED
DHW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
RETURN THERMISTOR SATISFACTORY
RESULT AS EXPECTED
BLANK FOR QUICK ACCESS DATA AND INFORMATION 2
Z DIRECTION
BLANK FOR DIAGNOSICS LITE
Z DIRECTION
DHW FLOW TURBINE SATISFACTORY
RESULT AS EXPECTED
PUMP RUNS DHW DEMAND ERP PUMP
KIT - PUMP HEAD
START- UP2
KIT - PUMP HEAD
ERP PUMP RESISTANCE SATISFACTORY
RESULT AS EXPECTED
OBSERVATION DISPLAY AND SELF CHECK - NO DISPLAY
KIT - CUI BOARD
FURTHER INVESTIGATION F1
Z DIRECTION
FURTHER IN VESTIGATION F2
Z DIRECTION
POWER OK PCB DEAD
KIT - PCB L10 - PRIMARY
INTEGRAL FUSE FATIGUED
KIT - PCB L10 - PRIMARY
OBSERVATION DISPLAY AND SELF CHECK - NO DISPLAY PARTIAL DISPLAY
KIT - CUI BOARD
NO MAINS TO FAN AT START UP
KIT - PCB L10 - PRIMARY
ELECTRICAL OVER 15V ON N
KIT - FAN
NO FAN AT START UP
KIT - FAN
POWER UP - PUMP DOES NOT RUN ERP PUMP
KIT - PUMP HEAD
POWER UP - PUMP DOES NOT RUN START- UP2
KIT - PUMP HEAD
POWER UP - FIRING UP WITH NO DHW DEMAND
KIT - PCB L10 - PRIMARY
ON WITH NO DEMAND - PREHEAT
KIT - PCB L10 - PRIMARY
FAN DOES NOT RUN DHW
KIT - PCB L10 - PRIMARY
SENSOR PRIMARY FAN RUNS
HARNESS - WIRING - SELV
FAN RUNS DHW
CONTROL THERMISTOR (RETURN)
IGNORING DHW DEMAND
KIT - PCB L10 - PRIMARY
BURNER IGNITES AND ESTABLISHES - NO SPARKING
KIT - PCB L10 - PRIMARY
SPARKING OCCURS BURNER DOES NOT IGNITE
UNIT - IGNITOR
POOR SUPPLY
GAS INLET PRESSURE
SPARK BUT NOT LIGHTING
KIT - GAS VALVE
BURNER DOES NOT IGNITELEAKING POC
KIT - REPLACEMENT - SUMP COVER
BURNER DOES NOT IGNITELEAKING POC
MANIFOLD - FLUE
SPARKING BUT NOT LIGHTING
ELECTRODE - IGNITION
SPARK BUT NOT LIGHTING
ELECTRODE - IGNITION
BURNER DOES NOT IGNITE
KIT - GAS VALVE
BURNER IGNITES AND ESTABLISHES - FLAME SENSE
HARNESS - WIRING - MAINS
FLAME SENSE BURNER IGNITES DOES NOT ESTABLISH
KIT - PCB L10 - PRIMARY
BURNER DOES NOT IGNITELEAKING POCBAFFLES
MANIFOLD - FLUE
BURNER DOES NOT IGNITELEAKING POCBAFFLES
KIT - REPLACEMENT - SUMP COVER
IGNITES BUT BAFLLES OR NOISY
KIT - GAS VALVE
OPERATION DHW - DHW COOL RADS COOL
KIT - PRESSURE GAUGE
OPERATION DHW - DHW COOL RADS COOL
SYSTEM PRESSURE
DHW NOISY
KIT - PRESSURE GAUGE
DHW NOISY
SYSTEM PRESSURE
DHW NOISY KETTLING
KIT - PLATE HEAT EXCHANGER
DHW RUNS HOT COLD
KIT - PRESSURE GAUGE
DHW RUNS HOT COLD
SYSTEM PRESSURE
DHW NOISY KETTLING
KIT - HEAT ENGINE
HOT WATER CYCLING
KIT - PLATE HEAT EXCHANGER
CH NOISY
KIT - PRESSURE GAUGE
CH NOISY
SYSTEM PRESSURE
CH UP TO TEMP RADS COLD
KIT - PRESSURE GAUGE
CH UP TO TEMP RADS COLD
SYSTEM PRESSURE
RADS COLD BOILER HOT
MOTOR DIVERTER VALVE
BLANK FOR L1 FAULT CODE
Z DIRECTION
PREHEAT SATISFACTORY4
MOTOR DIVERTER VALVE
RADS COLD BOILER HOT2
MOTOR DIVERTER VALVE
FAULT CODE L1 ERP
KIT - PUMP HEAD
START- UP2 L1
KIT - PUMP HEAD
ALL CHECKS OK RETEST MODEL
OVERHEAT NO FAULT FOUND
LEAKING POC
KIT - REPLACEMENT - SUMP COVER
F1 - LOW WATER FAULT
KIT - PCB L10 - PRIMARY
F1 - LOW WATER FAULT
SWITCH - PRESSURE - WATER
F2 NO MAINS TO FAN
KIT - PCB L10 - PRIMARY
F2 OVER 15V ON N
KIT - FAN
F2 NO FAN AT START UP
KIT - FAN
F6 - OUTDOOR SENSOR
KIT - PCB L10 - PRIMARY
F9
KIT - PCB L10 - PRIMARY
LEAKING POC L1 L3
MANIFOLD - FLUE
TO PUMP - FURTHER INVESTIGATION FUSE F1ERP PUMP
HARNESS - WIRING - MAINS
TO FAN - FURTHER INVESTIGATION FUSE F1ERP PUMP
HARNESS - WIRING - MAINS
FURTHER INVESTIGATION FUSE F1ERP PUMP
KIT - PCB L10 - PRIMARY
TO SPARK GEN - FURTHER INVESTIGATION FUSE F1ERP PUMP
HARNESS - WIRING - MAINS
TO PUMP - FURTHER INVESTIGATION FUSE F1
HARNESS - WIRING - MAINS
TO FAN - FURTHER INVESTIGATION FUSE F1
HARNESS - WIRING - MAINS
FURTHER INVESTIGATION FUSE F1
KIT - PCB L10 - PRIMARY
TO SPARK GEN - FURTHER INVESTIGATION FUSE F1
HARNESS - WIRING - MAINS
OPERATION CH RADIATORS COOL
KIT - PCB L10 - PRIMARY
DIVERTER VOLTAGE SATISFACTORY CH
RESULT AS EXPECTED
FURTHER INVESTIGATION FUSE F1
KIT - GAS VALVE
FURTHER INVESTIGATION FUSE F1ERP PUMP
KIT - GAS VALVE
STOPPING PRESEQ BREAKING 2
Z DIRECTION
PUMP VOLTAGE (LV)
RESULT AS EXPECTED
FURTHER INVESTIGATION FUSE F1
MOTOR DIVERTER VALVE
FURTHER INVESTIGATION FUSE F1ERP PUMP
MOTOR DIVERTER VALVE
FUSE INVESTIGATION
HARNESS (MAIN) - ERP PUMP HARNESS
DIVERTER REFITTING 2
Z DIRECTION
DHW COOL RADS COOL
KIT - PLATE HEAT EXCHANGER
FAULT CODE L3
KIT - PLATE HEAT EXCHANGER
RESTRICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND
KIT - SIPHON TRAP
DHW COOL RADS COOL
KIT - PCB L10 - PRIMARY
RESTRICTED OPERATION DHW DHW COOL RADS COLD NO CH DEMAND LPG
KIT - SIPHON TRAP
DHW COOL RADS COOL LPG
KIT - PCB L10 - PRIMARY
FAULT CODE IN TREE 1
Z DIRECTION
F2 BURNER IGNITES AND ESTABLISHES - FLAME SENSE
HARNESS - WIRING - MAINS
L6 BURNER IGNITES AND ESTABLISHES - FLAME SENSE
HARNESS - WIRING - MAINS
NO CH 2
HARNESS INTERNAL TIMER (X1A)
NOT RESPONDING TO HEATING 2
KIT - PCB L10 - PRIMARY
DOES NOT RECOGNISE CH DEMAND
HARNESS INTERNAL TIMER (X1A)
IGNORING CH DEMAND - INTERNAL TIMER
KIT - PCB L10 - PRIMARY
CH DEMAND OUTDOOR SENSOR
Z DIRECTION
NOT OPENING - MECHANICAL
KIT - GAS VALVE
INCORRECT RESISTANCE KESTON
KIT - GAS VALVE
TO GAS VALVE - NO POWER ON IGN
HARNESS - WIRING - MAINS
OUTDOOR SENSOR SATISFACTORY
RESULT AS EXPECTED
POWER UP - FIRING WITH NO FROST DEMAND
KIT - PCB L10 - PRIMARY
ON WITH NO DEMAND - FROST
KIT - PCB L10 - PRIMARY
EXPANSION CONNECTION
KIT - PIPE - EXPANSION VESSEL
TO RETURN SENSOR - HOT WATER CYCLING
HARNESS - WIRING - SELV
TO HEATING SENSOR - HOT WATER CYCLING
HARNESS - WIRING - SELV
DHW TOO HOT
KIT - PCB L10 - PRIMARY
MIXING - HOT WATER CYCLING
EXTERNAL HOT WATER FAULT
NO DISPLAY SEEN
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES
DIFFERENTIAL OK
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
TEMP DIFF CORRECT LOCAL BOILING
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL RADS COLD
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL RADS HOT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW NOISY KETTLING
CHARACTERISTIC TEST FROM OPERATION DHW
DHW RUNS HOT THEN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
DIAGNOSTICS LITE OPTION
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
QUICK ACCESS DATA AND INFORMATION OPTION
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA RETURN THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FLOW THERMISTOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA GAS VALVE VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA GAS VALVE RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA PUMP RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA PUMP VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR VOLTAGE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA DIVERTER RESISTANCE
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA DIVERTER VOLTAGE DHW
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
NEEDED OR PRESEQ MESSES UP DIVERTER VOLTAGE FOR SOME REASON
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
NO VOLTAGE MEASURED
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
GREATER THAN 15VAC ON BLUE
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
HEADER FOR DHW FLOW SWITCH
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA PUMP RESISTANCE (ERP)
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
LED ILLUMINATES BUT DISPLAY DOES NOT OPERATE
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY OPERATES
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK AND STANDBY
NO VOLTAGE MEASURED
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
GREATER THAN 15VAC ON BLUE
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK AND STANDBY
DEMAND SHOWN OR PUMP CONTINUES TO RUN AFTER INITIAL 20 SECONDS
CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK AND STANDBY
BOILER FROST PROTECTION SHOWING
CHARACTERISTIC TEST FROM OBSERVATION WHICH DEMAND IS SHOWING
HOT WATER SHOWING
CHARACTERISTIC TEST FROM OBSERVATION WHICH DEMAND IS SHOWING
PREHEAT OPERATION SHOWING
CHARACTERISTIC TEST FROM OBSERVATION WHICH DEMAND IS SHOWING
DISPLAY REACTS AS DESCRIBED BUT FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION PUMP & FAN RUNS DHW DEMAND
BURNER DOES NOT IGNITE - IGNITION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES DHW DEMAND
INLET PRESSURE DOES NOT CHANGE
CHARACTERISTIC TEST FROM PRESSURE GAS INLET (BLIP TEST)
INLET PRESSURE DROPS AWAY
CHARACTERISTIC TEST FROM PRESSURE GAS INLET (BLIP TEST)
SPARK ELECTRODE IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION ELECTRODE SPARK GAP
SPARK GAP INCORRECT
CHARACTERISTIC TEST FROM INSPECTION ELECTRODE SPARK GAP
BURNER IGNITES BUT DOES NOT ESTABLISH - RECTIFICATION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES DHW DEMAND
BURNER IGNITES BUT BAFFLES OUT OR IS NOISY - COMBUSTION ISSUE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES DHW DEMAND
SYSTEM PRESSURE OK BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE OK BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE OK BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE OK BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE OK BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE AND RISE
DIVERTER VALVE DOES NOT GO TO HEATING POSITION
CHARACTERISTIC TEST FROM INSPECTION DIVERTER VALVE HEAD OPERATION
DIVERTER VALVE DOES NOT GO TO HOT WATER POSITION
CHARACTERISTIC TEST FROM INSPECTION DIVERTER VALVE HEAD OPERATION
NO VOLTAGE MEASURED
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
GREATER THAN 15VAC ON BLUE
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
HEADER FOR QUICK ACESS DATA DIVERTER VOLTAGE CH
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
HEADER FOR QUICK ACCESS DATA PUMP VOLTAGE (LOW VOLTAGE)
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
NEEDED OR PRESEQ MESSES UP DIVERTER VOLTAGE FOR SOME REASON
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
FAULT CODE DISPLAYED
CHARACTERISTIC TEST FROM OBSERVATION SELF CHECK AND STANDBY
HEADER FOR QUICK ACCESS DATA OUTDOOR SENSOR
CHARACTERISTIC TEST FROM NEW QADAI OPTIONS
BOILER NOISY
CHARACTERISTIC TEST FROM OPERATION CH
BOILER REACHES TEMPERATURE AND/OR SHUTS DOWN RADS COLD OR COOL
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
SYSTEM PRESSURE RISE EXCESSIVE
CHARACTERISTIC TEST FROM OPERATION CH
DISPLAY REACTS AS DESCRIBED BUT PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION PUMP & FAN RUNS DHW DEMAND
DISPLAY DOES NOT REACT AS DESCRIBED AND NEITHER THE FAN NOR THE PUMP RUN
CHARACTERISTIC TEST FROM OBSERVATION PUMP & FAN RUNS DHW DEMAND
28/12/2023 13:58:53 2307_1_50_1 22/02/2024 11:34:55
16/02/2024 15:29:00
RESISTANCE SENSOR FLOW AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE DETECTION LEAD AND HARNESS
DISCONNECT FLAME SENSE DETECTION LEAD FROM THE ELECTRODE
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE MAINS POWER SUPPLY - F7 FAULT CODE
GAIN ACCESS TO INCOMING MAINS TERMINAL BLOCK (USE INSULATION MAT AS NECESSARY)
POWER OFF RESET BOILER
PREHEAT OFF
WAIT APPROXIMATELY 15 SECONDS
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
TEMPERATURE DIFFERENTIAL FLOW RETURN (CH)
CH TEMPERATURE CONTROL SET TO MAX
OBSERVATION BOILER RESET - OVERHEAT
ENSURE BOILER IS COOL AND NO DEMANDS ARE PRESENT
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
VOLTAGE TO DIVERTER VALVE (DHW)
{ALLDEMANDOFF}
SE
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE PUMP HARNESS (ERP)
DISCONNECT MAINS VOL
VOLTAGE MAINS POWER SUPPLY AT TERMINAL BLOCK
GAIN ACCESS TO INCOMING MAINS TERMINAL BLOCK (USE INSULATION MAT AS NECESSARY)
RESISTANCE FUSE F1 (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
RESISTANCE PUMP HARNESS (ERP)
DISCONNECT MAINS VOL
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
VOLTAGE SPARK GENERATOR INPUT (AT PCB)
GAIN ACCESS TO PCB (
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE DETECTION LEAD
DISCONNECT FLAME SEN
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
INSPECTION INTERNAL BYPASS
DRAIN BOILER PRIMARY CIRCUIT
TWIST AND LIFT / PRISE OUT INTERNAL BYPASS
VOLTAGE DIVERTER VALVE (HEATING)
{ALLDEMANDOFF}
SE
VOLTAGE PUMP AT PCB
GAIN ACCESS TO PCB (
RESISTANCE PUMP HARNESS (ERP)
DISCONNECT MAINS VOL
TEMPERATURE DIFFERENTIAL FLOW RETURN (CH)
CH TEMPERATURE CONTROL SET TO MAX
RESISTANCE LOW WATER PRESSURE SWITCH
DISCONNECT WIRES FROM LOW WATER PRESSURE SWITCH
VOLTAGE FAN (AT PCB)
SLIGHTLY MOVE CONNECTORS UNTIL PCB CONNECTION STRIPS
ARE EXPOSED FOR VOLTAGE MEASUREMENT
RESISTANCE PUMP AND HARNESS (ERP)
REMOVE CONNECTOR X1 FROM THE PCB
RESISTANCE PUMP (ERP)
UNPLUG THE MAINS HARNESS (LEFT HAND SIDE) FROM THE PUMP
RESISTANCE PUMP
UNPLUG THE HARNESS FROM THE SIDE OF THE PUMP AND REMOVE THE PUMPS ELECTRICAL COVER
RESISTANCE FAN
DISCONNECT THE 3 PIN POWER CONNECTOR FROM THE FAN
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM GAS VALVE
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE SPARK GENERATOR
REMOVE THE MAINS CONNECTOR FROM THE SPARK GENERATOR
RESISTANCE PUMP
UNPLUG THE HARNESS FROM THE SIDE OF THE PUMP AND REMOVE THE PUMPS ELECTRICAL COVER
RESISTANCE FAN
DISCONNECT THE 3 PIN POWER CONNECTOR FROM THE FAN
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM GAS VALVE
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE SPARK GENERATOR
REMOVE THE MAINS CONNECTOR FROM THE SPARK GENERATOR
INFORMATION DIVERTER VALVE REFITTING PROCEDURE
1. ENSURE TH
RESISTANCE DETECTION LEAD
DISCONNECT FLAME SEN
RESISTANCE DETECTION LEAD
DISCONNECT FLAME SEN
OBSERVATION BYPASS EXTERNAL CONTROLS
PLACE A WIRE LINK BE
RESISTANCE HARNESS X1 TO TERMINAL BLOCK - NO TIMER FITTED
REMOVE CONNECTOR X1 FROM THE PCB
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL ON THE FRONT OF THE APPLIANCE
RESISTANCE HARNESS X1 TO TERMINAL BLOCK
INTERNAL TIMER SWITCHED TO THE ON POSITION
REMOVE CONNECTOR X1 FROM THE PCB
RESISTANCE INTERNAL TIMER
INTERNAL TIMER SWITCHED TO THE ON POSITION
REMOVE CONNECTIONS 3 AND 4 FROM THE INTERNAL TIMER
INSPECTION INTERNAL BYPASS
DRAIN BOILER PRIMARY CIRCUIT
TWIST AND LIFT / PRISE OUT INTERNAL BYPASS
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM GAS VALVE
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE FLUE STAT
REMOVE LEADS FROM FLUE THERMOSTAT
IF NEEDED REMOVE FLUE MANIFOLD FOR BETTER ACCESS TO THERMOSTAT
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
INSPECTION DETECTION ELECTRODE
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
OPERATION CH (FOR HEAT EX DIAG)
PREHEAT OFF
CH TEMPERATURE CONTROL SET TO MAXIMUM
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
TEMPERATURE DIFFERENTIAL HEATING FLOW AND RETURN
PREHEAT OFF
ATTACH TEMP PROBES TO THE FLOW AND RETURN PIPES AS CLOSE TO THE BOILER AS POSSIBLE
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
INSPECTION DIVERTER VALVE HEATING POSITION
SELECTOR SWITCH SET TO CH/DHW
CH TEMPERATURE CONTROL SET TO MAX
PREHEAT SWITCHED OFF
RESISTANCE SENSOR RETURN AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR FLOW AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
OBSERVATION SYSTEM PRESSURE RISE
LOCATE SYSTEM FILLING LOOP
OBSERVATION SYSTEM PRESSURE RISE
LOCATE SYSTEM FILLING LOOP
INSPECTION DIVERTER VALVE DHW POSITION
SELECTOR SWITCH SET TO DHW
DHW TEMPERATURE CONTROL SET TO MAX
PREHEAT SWITCHED OFF
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE HARNESS FLOW SWITCH
REMOVE CONNECTOR FOR DHW FLOW TURBINE
PULL CONNECTOR X8 BACK SLIGHTLY TO EXPOSE TEST POINTS
RESISTANCE DETECTION LEAD AND HARNESS
DISCONNECT FLAME SENSE DETECTION LEAD FROM THE ELECTRODE
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION DETECTION ELECTRODE
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
INSPECTION INJECTOR
REMOVE GAS INJECTOR FROM THE FAN VENTURI
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
INSPECTION SPARK ELECTRODE
REMOVE THE BURNER FROM THE BOILER
INSPECTION GAS VALVE INLET FILTER
REMOVE THE GAS VALVE ASSEMBLY
INSPECTION DIVERTER VALVE SPINDLE
REMOVE DIVERTER VALVE ACTUATOR, TO REMOVE PULL HEAD TOWARDS GAS PIPE
INSPECTION HEAT EXCHANGER DHW
MAINS WATER SUPPLY O
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
DIAGNOSTICS LITE
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
VOLTAGE GAS VALVE AT PCB
GAIN ACCESS TO PCB (
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP
UNPLUG THE HARNESS FROM THE SIDE OF THE PUMP AND REMOVE THE PUMPS ELECTRICAL COVER
VOLTAGE PUMP AT PCB
GAIN ACCESS TO PCB (
RESISTANCE FAN
DISCONNECT THE 3 PIN POWER CONNECTOR FROM THE FAN
VOLTAGE FAN (AT PCB)
SLIGHTLY MOVE CONNECTORS UNTIL PCB CONNECTION STRIPS
ARE EXPOSED FOR VOLTAGE MEASUREMENT
VOLTAGE FAN CONTROL
REMOVE DC ELECTRICAL CONNECTOR FROM FAN ASSEMBLY (5 PIN CONNECTOR) & MAKE SAFE
RESISTANCE SPARK GENERATOR
REMOVE THE MAINS CONNECTOR FROM THE SPARK GENERATOR
VOLTAGE SPARK GENERATOR INPUT (AT PCB)
GAIN ACCESS TO PCB (
RESISTANCE DIVERTER VALVE AND HARNESS (QADAI)
REMOVE X2 CONNECTOR FROM THE PCB
VOLTAGE TO DIVERTER VALVE (DHW)
{ALLDEMANDOFF}
SE
RESISTANCE HARNESS FAN POWER
DISCONNECT MAINS VOLTAGE PLUG FROM FAN
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
VOLTAGE FROM HOT WATER FLOW TURBINE
PREHEAT OFF
GAIN ACCESS TO PCB (USE INSULATION MAT AS REQUIRED)
RUN HOT WATER TAP AT 3 L/MIN
RESISTANCE PUMP HARNESS
GAIN ACCESS TO PCB
REMOVE CONNECTOR FROM PUMP
RESISTANCE PUMP (ERP)
UNPLUG THE MAINS HARNESS (LEFT HAND SIDE) FROM THE PUMP
VOLTAGE DISPLAY PCB
GAIN ACCESS TO PCB (
RESISTANCE HARNESS DISPLAY PCB
GAIN ACCESS TO PCB <
VOLTAGE MAINS POWER SUPPLY AT PCB
GAIN ACCESS TO PCB (
RESISTANCE FUSE (F2) PCB
REMOVE FUSE FROM HOLDER
INSPECTION REGULATOR / FILTER DHW INLET
ISOLATE AND DRAIN THE MAINS WATER SUPPLY
REMOVE REGULATOR / FILTER FROM CARTRIDGE ASSEMBLY
RESISTANCE PCB INTEGRAL FUSE
REMOVE RIBBON CONNECTOR AT BOTTOM OF PCB
UNCLIP AND FLIP THE PCB ONTO ITS BACK
VOLTAGE DISPLAY PCB
GAIN ACCESS TO PCB (
RESISTANCE HARNESS DISPLAY PCB
GAIN ACCESS TO PCB <
VOLTAGE FAN (AT PCB)
SLIGHTLY MOVE CONNECTORS UNTIL PCB CONNECTION STRIPS
ARE EXPOSED FOR VOLTAGE MEASUREMENT
VOLTAGE FAN CONTROL
REMOVE DC ELECTRICAL CONNECTOR FROM FAN ASSEMBLY (5 PIN CONNECTOR) & MAKE SAFE
RESISTANCE HARNESS FAN POWER
DISCONNECT MAINS VOLTAGE PLUG FROM FAN
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE HARNESS FAN CONTROL
REMOVE LOW VOLTAGE CONNECTOR FROM FAN
RESISTANCE HARNESS FAN POWER
DISCONNECT MAINS VOLTAGE PLUG FROM FAN
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
VOLTAGE PUMP AT PCB START-UP
GAIN ACCESS TO PCB (
RESISTANCE PUMP HARNESS
GAIN ACCESS TO PCB
REMOVE CONNECTOR FROM PUMP
OBSERVATION ISOLATE DHW
TURN THE DHW ISOLATION VALVE OFF
OBSERVATION DISCONNECT FLOW TURBINE
UNPLUG ELECTRICAL CONNECTOR AT FLOW TURBINE AND MAKE SAFE
VOLTAGE EXTERNAL CONTROLS (NO DEMAND)
GAIN ACCESS TO THE BOILERS MAIN TERMINAL STRIP
ENSURE NO DEMAND FOR CH
RESISTANCE SELECTOR SWITCH
GAIN ACCESS TO THE CONTROL PCB
(THE MAIN PCB WILL NEED TO BE REMOVED)
RESISTANCE SENSOR FLOW AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR RETURN AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
INSPECTION SPARK OUTPUT
REMOVE THE HT LEAD F
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
RESISTANCE HARNESS SPARK GENERATOR
REMOVE CONNECTOR FROM SPARK GENERATOR
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE IGNITION LEAD
DISCONNECT BOTH ENDS OF THE SPARK (HT) LEAD
PRESSURE GAS INLET (BLIP TEST)
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION SUMP AND FLUE MANIFOLD
REMOVE SUMP INSPECTION COVER
VOLTAGE GAS VALVE AT PCB
GAIN ACCESS TO PCB (
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION INJECTOR
REMOVE GAS INJECTOR FROM THE FAN VENTURI
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION ELECTRODE SPARK GAP
CAREFULLY REMOVE BURNER FROM BOILER
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
RESISTANCE DETECTION LEAD AND HARNESS
DISCONNECT FLAME SENSE DETECTION LEAD FROM THE ELECTRODE
REMOVE CONNECTOR X3 FROM THE PCB
INSPECTION DETECTION ELECTRODE
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION SPARK ELECTRODE
REMOVE THE BURNER FROM THE BOILER
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
INSPECTION INJECTOR
REMOVE GAS INJECTOR FROM THE FAN VENTURI
INSPECTION FAN MECHANICAL
REMOVE THE FAN
INSPECTION SUMP AND FLUE MANIFOLD
REMOVE SUMP INSPECTION COVER
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION INTERNAL BYPASS
DRAIN BOILER PRIMARY CIRCUIT
TWIST AND LIFT / PRISE OUT INTERNAL BYPASS
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
RESISTANCE POTENTIOMETER - CH TEMPERATURE
REMOVE THE MAIN PCB TO GAIN ACCESS TO THE CONTROL PCB
INSPECTION DIVERTER VALVE SPINDLE
REMOVE DIVERTER VALVE ACTUATOR, TO REMOVE PULL HEAD TOWARDS GAS PIPE
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
INSPECTION DIVERTER VALVE HEAD OPERATION
SELECTOR SWITCH SET TO DHW/CH POSITION
TEMPERATURE CONTROLS SET TO MAX
PREHEAT OFF
INSPECTION DIVERTER VALVE SPINDLE
REMOVE DIVERTER VALVE ACTUATOR, TO REMOVE PULL HEAD TOWARDS GAS PIPE
VOLTAGE DIVERTER VALVE (HEATING)
{ALLDEMANDOFF}
SE
VOLTAGE TO DIVERTER VALVE (DHW)
{ALLDEMANDOFF}
SE
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
RESISTANCE HARNESS DIVERTER VALVE
REMOVE X2 FROM THE P
RESISTANCE PUMP HARNESS
GAIN ACCESS TO PCB
REMOVE CONNECTOR FROM PUMP
INSPECTION SUMP AND FLUE MANIFOLD
REMOVE SUMP INSPECTION COVER
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
DISCONNECT X8 AT THE PCB
INSPECT LOW WATER PRESSURE SENSOR (BLOCKAGE)
ISOLATE BOILER FROM THE HEATING CIRCUIT AND DRAIN BOILER
REMOVE LOW WATER PRESSURE SENSOR
VOLTAGE FAN CONTROL
REMOVE DC ELECTRICAL CONNECTOR FROM FAN ASSEMBLY (5 PIN CONNECTOR) & MAKE SAFE
RESISTANCE HARNESS FAN POWER
DISCONNECT MAINS VOLTAGE PLUG FROM FAN
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE HARNESS FAN CONTROL
REMOVE LOW VOLTAGE CONNECTOR FROM FAN
RESISTANCE HARNESS FAN POWER
DISCONNECT MAINS VOLTAGE PLUG FROM FAN
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
OBSERVATION DISCONNECT OUTDOOR SENSOR
DISCONNECT X7 PLUG FOR OUTDOOR SENSOR
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X1 FROM THE PCB
RESISTANCE FAN AND HARNESS (MAINS POWER)
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS AND DIVERTER VALVE
REMOVE X2 CONNECTOR FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS AND SPARK GENERATOR
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X1 FROM THE PCB
RESISTANCE FAN AND HARNESS (MAINS POWER)
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS AND DIVERTER VALVE
REMOVE X2 CONNECTOR FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE HARNESS AND SPARK GENERATOR
REMOVE CONNECTOR X3 FROM THE PCB
OBSERVATION DISCONNECT OUTDOOR SENSOR (CH OP)
DISCONNECT X7 PLUG FOR OUTDOOR SENSOR
VOLTAGE DIVERTER VALVE (HEATING)
{ALLDEMANDOFF}
SE
VOLTAGE PUMP SPEED CONTROL
DISCONNECT PUMP SPEE
INSPECTION INTERNAL BYPASS
DRAIN BOILER PRIMARY CIRCUIT
TWIST AND LIFT / PRISE OUT INTERNAL BYPASS
INSPECTION INTERNAL BYPASS
DRAIN BOILER PRIMARY CIRCUIT
TWIST AND LIFT / PRISE OUT INTERNAL BYPASS
INSPECTION INJECTOR
REMOVE GAS INJECTOR FROM THE FAN VENTURI
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
RESISTANCE POTENTIOMETER - DHW TEMPERATURE
GAIN ACCESS TO CONTROL PCB
INSPECTION FAN MECHANICAL
REMOVE THE FAN
INSPECTION GAS VALVE INLET FILTER
REMOVE THE GAS VALVE ASSEMBLY
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
INSPECTION INJECTOR
REMOVE GAS INJECTOR FROM THE FAN VENTURI
INSPECTION CONDENSATE TRAP
REMOVE THE CONDENSATE TRAP FROM THE BOILER
RESISTANCE POTENTIOMETER - DHW TEMPERATURE
GAIN ACCESS TO CONTROL PCB
INSPECTION FAN MECHANICAL
REMOVE THE FAN
INSPECTION GAS VALVE INLET FILTER
REMOVE THE GAS VALVE ASSEMBLY
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION HEAT EXCHANGER (FLUE WAYS)
REMOVE THE BURNER FROM THE BOILER
OBSERVATION BYPASS EXTERNAL CONTROLS
PLACE A WIRE LINK BE
RESISTANCE SELECTOR SWITCH
GAIN ACCESS TO THE CONTROL PCB
(THE MAIN PCB WILL NEED TO BE REMOVED)
RESISTANCE SELECTOR SWITCH
GAIN ACCESS TO THE CONTROL PCB
(THE MAIN PCB WILL NEED TO BE REMOVED)
OBSERVATION DISCONNECT OUTDOOR SENSOR (CH DEMAND)
DISCONNECT X7 PLUG FOR OUTDOOR SENSOR
OBSERVATION TEMPERATURE FLOW AND RETURN
CH TEMPERATURE CONTR
RESISTANCE HARNESS GAS VALVE
REMOVE CONNECTOR FROM GAS VALVE
PULL X3 BACK SLIGHTLY TO EXPOSE TEST PINS
RESISTANCE OUTDOOR SENSOR AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X7 FROM PCB
RESISTANCE SENSOR FLOW AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR RETURN AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
VOLTAGE EXTERNAL FROST STAT
{ALLDEMANDOFF}
PREHEAT OFF
GAIN ACCESS TO THE BOILERS MAIN TERMINAL STRIP
RESISTANCE SENSOR FLOW
REMOVE THE ELECTRICA
RESISTANCE POTENTIOMETER - DHW TEMPERATURE
GAIN ACCESS TO CONTROL PCB
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
EXPANSION VESSEL PRESSURE
SYSTEM PRESSURE DISCHARGED
RESISTANCE SENSOR FLOW AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR RETURN AND HARNESS
GAIN ACCESS TO PCB
DISCONNECT PLUG X6 FROM PCB
RESISTANCE SENSOR RETURN
DISCONNECT PLUG FROM RETURN SENSOR
VOLTAGE FROM HOT WATER FLOW TURBINE
PREHEAT OFF
GAIN ACCESS TO PCB (USE INSULATION MAT AS REQUIRED)
RUN HOT WATER TAP AT 3 L/MIN
VOLTAGE PUMP AT PCB
GAIN ACCESS TO PCB (
System Information
- Total Tests: 765
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control