47-581-29 RAVENHEAT LS80

WARNING - IMPORTA

Next: &1, *

RAVENHEAT LITTLE STAR LS80

G.C. NUMBER 47 581 2

Next: &661, !f2

OPERATIONAL SEQUENCE

Next: &5, !f658

DHW FLOW RATE

Next: &15, f6

DHW PUMP RUNS

Next: &37, f16

DHW FAN RUNS

Next: &51, f38

DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)

LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.

Next: &106, ?52, ?54, ?58, ?393

DHW OPERATION

Next: &127, ?107, ?109, ?111, ?113

DHW MODULATION

LOOSEN THE OUTLET TE

Next: &135, f128

CH IGNITION

Next: &147, f740

CH OPERATION

LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.

Next: &170, ?148, ?150, ?152

SYSTEM PRESSURE RISE

SELECTOR SWITCH TO HEATING AND HOT WATER POSITION

Next: &172, !f171

CH MODULATION

LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.

Next: &178, f173

CH PUMP OVERRUNS

Next: &nff, f179

GAS VALVE VARIATION

DURING THE PRODUCTIO

Next: &3, !f662

BURNER PRESSURE LOW

GAS INLET PRESSURE

Next: End

MOD SOL

GAS VALVE

Next: End

DHW MODULATION

DHW POTENTIOMETER

Next: End

BOILER UP TO TEMP, RADIATORS COLD

3 WAY VALVE

Next: End

BOILER NOISY, KETTLING

3 WAY VALVE

Next: End

EXP VESS

EXPANSION VESSEL

Next: End

CH MODULATION

CH SENSOR

Next: End

CH MODULATION

CH POTENTIOMETER

Next: End

CH PUMP OVERRUNS

CH SENSOR

Next: End

PUMP RUNS

ON/OFF SWITCH

Next: End

DHW PUMP RUNS

FUSE F1 (2A)

Next: End

START

START

Next: End

LOW BURNER PRESS

CH SENSOR

Next: End

BURNER PRESSURE LOW

DHW SENSOR

Next: End

LOW BRUNER PRESS

DHW POTENTIOMETER

Next: End

SPARKING

FLUE

Next: End

SPARKING

FLUE VENTURI

Next: End

SPARKING

AIR PRESSURE SWITCH TUBES

Next: End

SPARKING

CASE NOT SEALING CORRECTLY

Next: End

OH THERMOSTAT

OVERHEAT THERMOSTAT

Next: End

HEAT EX FLUE

HEAT EXCHANGER (FLUEWAYS)

Next: End

GAS INLET PRES

GAS INLET PRESSURE

Next: End

BAFFLES OUT

CASE NOT SEALING CORRECTLY

Next: End

AIR PRESSURE SWITCH TUBES

AIR PRESSURE SWITCH TUBES

Next: End

DOESN'T CROSS LIGHT, PRESSURE ABSENT

GAS INLET PRESSURE

Next: End

MOD SOL - NOT CROSS LIGHTING

GAS VALVE

Next: End

FLUE VENTURI

FLUE VENTURI

Next: End

FLUE

FLUE

Next: End

NOT LIGHTING

PCB

Next: End

NOT LIGHTING

GAS VALVE

Next: End

NOT LIGHTING

BURNER

Next: End

DHW SENSOR (FULL DEMAND)

DHW SENSOR

Next: End

DHW CYCLING

PUMP

Next: End

DHW TOO COOL RADIATORS COLD

DHW SENSOR

Next: End

DHW MODULATION

DHW SENSOR

Next: End

BOILER COLD, RADIATORS COLD

CH POTENTIOMETER

Next: End

BOILER COLD, RADIATORS COLD

CH SENSOR

Next: End

BOILER NOISY, KETTLING

PUMP

Next: End

TOO HOT

CH POTENTIOMETER

Next: End

TOO HOT

CH SENSOR

Next: End

SYSTEM BYPASS

Next: End

SHUTING OFF EARLY

CH SENSOR

Next: End

SHUTING DOWN EARLY

CH POTENTIOMETER

Next: End

SPARKING

ELECTRODE LEAD

Next: End

SPARK GAP

ELECTRODE

Next: End

NOT CROSS LIGHTING

BURNER INJECTOR

Next: End

NOT CROSS LIGHTING

BURNER

Next: End

NOT CROSS LIGHTING

HEAT EXCHANGER (FLUEWAYS)

Next: End

DHW PUMP RUNS

Next: End

FAN IMPELLOR

FAN IMPELLOR

Next: End

PUMP RUNS

DHW SENSOR

Next: End

PUMP RUNS

CH SENSOR

Next: End

DHW PUMP RUNS

3 WAY VALVE MICROSWITCH

Next: End

PUMP RUNS

3 WAY VALVE

Next: End

LOW WATER

SYSTEM PRESSURE

Next: End

SEQ OF OPS

SEQ OF OPS

Next: End

GAS VALVE VARIATION

GAS VALVE VARIATION

Next: End

FLOW SENSOR - FAN NOT RUNNING

CH SENSOR

Next: End

FAN NOT RUNNING

DHW SENSOR

Next: End

FAN NOT RUNNING

DHW POTENTIOMETER

Next: End

DHW NOISY

DHW POTENTIOMETER

Next: End

DHW NOISY

DHW SENSOR

Next: End

DHW COOL

BURNER INJECTOR

Next: End

PUMP RUNS

SUMMER/WINTER SWITCH

Next: End

TIMER

Next: End

EXTERNAL CONTROLS

Next: End

NO HEATING

CH SENSOR

Next: End

CH POT

CH POTENTIOMETER

Next: End

DHW FLOW RATE

DHW ISOLATING VALVE

Next: End

DHW FLOW RATE

DHW INLET FILTER

Next: End

DHW TOO COOL RADIATORS COLD

HEAT EXCHANGER

Next: End

BLOCKED

3 WAY VALVE

Next: End

DHW PUMP RUNS

PUMP

Next: End

CH MODULATION

PCB

Next: End

CH PUMP OVERRUNS

PCB

Next: End

FAN

FAN

Next: End

FLOW SENSOR - LOW BURNER PRESS

WIRING HARNESS

Next: End

DHW SENSOR - LOW BURNER PRESS

WIRING HARNESS

Next: End

BURNER PRESSURE LOW

PCB

Next: End

SPARKING

AIR PRESSURE SWITCH

Next: End

BAFFLES OUT

FLAME SENSE ELECTRODE

Next: End

BAFFELS OUT

HARNESS FLAME SENSE

Next: End

FLAME SENSE

PCB

Next: End

AIR PRESSURE SWITCH

AIR PRESSURE SWITCH

Next: End

NOT LIGHTING

GAS INLET PRESSURE

Next: End

NOT LIGHTING

BURNER INJECTOR

Next: End

DHW SENSOR - HOT WATER CYCLES

WIRING HARNESS

Next: End

DHW CYCLING

SECONDARY (DHW) HEAT EXCHANGER

Next: End

DHW SENSOR - DHW TOO COOL

WIRING HARNESS

Next: End

DHW OPERATION NOISY

HEAT EXCHANGER

Next: End

DHW MODULATION

PCB

Next: End

DHW SENSOR - MOD

WIRING HARNESS

Next: End

FLOW SENSOR - BOILER AND RADS COLD

WIRING HARNESS

Next: End

BOILER TOO HOT

PCB

Next: End

FLOW SENSOR - BOILER TOO HOT

WIRING HARNESS

Next: End

BOILER NOISY, KETTLING

HEAT EXCHANGER

Next: End

BOILER TOO HOT

Next: End

FLOW SENSOR - BOILER SHUT DOWN RADS COLD

WIRING HARNESS

Next: End

SHUTTING DOWN EARLY

PCB

Next: End

APS AIR DETECT

PCB

Next: End

NOT CROSS LIGHTING

FLUE

Next: End

DHW SENSOR - PUMP RUNS

WIRING HARNESS

Next: End

FLOW SENSOR - PUMP RUNS

WIRING HARNESS

Next: End

DV PUMP RUNS

PCB

Next: End

LOW WATER

LOW WATER PRESSURE SWITCH

Next: End

FLOW SENSOR - FAN NOT RUNNING

WIRING HARNESS

Next: End

FAN NOT RUNNING DHW SENSOR

WIRING HARNESS

Next: End

FAN NOT RUNNING

PCB

Next: End

FAN

WIRING HARNESS

Next: End

LOW IGN PRESSURE

GAS VALVE ADJUSTMENT

Next: End

GAS INLET PRESSURE (FULL DEMAND)

GAS VALVE ADJUSTMENT

Next: End

DOESNT CROSS LIGHT

GAS VALVE ADJUSTMENT

Next: End

DHW MODULATION

GAS VALVE ADJUSTMENT

Next: End

CH MODULATION

GAS VALVE ADJUSTMENT

Next: End

DHW NOISY

GAS VALVE ADJUSTMENT

Next: End

DHW NOISY

PCB

Next: End

DHW NOISY

WIRING HARNESS

Next: End

DHW NOISY OPERATION KETTLES

SECONDARY (DHW) HEAT EXCHANGER

Next: End

DHW TOO COOL RADIATORS COLD

DHW POTENTIOMETER

Next: End

FLOW SENSOR - NO HEATING

WIRING HARNESS

Next: End

SCALED

SECONDARY (DHW) HEAT EXCHANGER

Next: End

DHW RUNS HOT AND COLD, BURNER CYCLES ON AND OFF

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p470

DHW TOO COOL, RADIATORS HOT

CHARACTERISTIC TEST FROM DHW OPERATION

Next: !p110

DHW INLET FILTER BLOCKED

CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER

Next: !p12

DHW TOO COOL, RADS COLD

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p112

DHW NOISY OPERATION, KETTLES

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p114

DIVERTER VALVE BLOCKED

CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER

Next: !p14

BOILER NOISY, KETTLING

CHARACTERISTIC TEST FROM CH OPERATION

Next: p149

BOILER HOT BUT RADIATORS COLD

CHARACTERISTIC TEST FROM CH OPERATION

Next: p151

BOILER COLD, RADIATORS COLD

CHARACTERISTIC TEST FROM CH OPERATION

Next: p567

BURNER DOES NOT CROSS LIGHT CORRECTLY

CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)

Next: p394

LEAD OK BUT ELECTRODE IN POOR CONDITION

CHARACTERISTIC TEST FROM FLAME SENSE ELECTRODE AND LEAD

Next: !p405

ELECTRODE OK BUT LEAD IN POOR CONDITION

CHARACTERISTIC TEST FROM FLAME SENSE ELECTRODE AND LEAD

Next: !p407

PRESSURE DROPS AWAY COMPLETELY

CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)

Next: !p458

NO DROP OBSERVED

CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)

Next: p460

BURNER LIGHTS BUT PRESSURE REMAINS LOW

CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)

Next: p53

BURNER DOES NOT LIGHT

CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)

Next: p337

BURNER LIGHTS BUT BAFFLES OUT

CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)

Next: p59

23/12/2011 15:49:12 1_1_50_2 05/01/2012 13:22:15

13/12/2011 13:48:15

Next: End

DHW MODULATION VOLTAGE

SET FLOW RATE AT TAP TO APPROXIMATELY 5 L/MIN

Next: !p716, f130

DHW POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: p494, !f132

PUMP VOLTAGE

Next: !p17, f18

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: p174, !f175

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p180, !f181

ON/OFF SWITCH VOLTAGE (INPUT)

Next: p182, !f636

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: p223, f224

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p225, !f232

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p248, !f242

OVERHEAT THERMOSTAT RESISTANCE

REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT.

Next: p352, !f379

CASE FITTED CORRECTLY

Next: p356, !f378

AIR PRESSURE SWITCH RESISTANCE (NORMALLY OPEN)

REMOVE PLASTIC COVER FROM THE PCB
DISCONNECT THE CONNECTOR AT M3 FROM THE PCB

Next: p39, f40

AIR PRESSURE SWITCH TUBES

Next: p41, !f42

GAS INLET PRESSURE

ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT

Next: p418, !f420

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p474, !f475

PUMP LIMPET TEST

Next: !p479, !f480

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p482, !f483

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p497, !f498

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p572, !f573

PUMP LIMPET TEST

Next: !p605, !f591

MODULATION VOLTAGE - CH

Next: !p717, f596

CH POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: p597, !f598

DHW ISOLATING VALVE

Next: p7, !f8

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p601, !f602

PUMP LIMPET TEST

Next: p608, !f609

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p615, !f616

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p642, !f643

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p646, !f647

SYSTEM PRESSURE

Next: !p653, !f655

FAN VOLTAGE FROM PCB

Next: !p712, f700

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: p701, f702

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p703, !f704

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p707, !f708

DHW MODULATION

LOOSEN THE OUTLET TE

Next: p728, f719

DHW MODULATION VOLTAGE

SET FLOW RATE AT TAP TO APPROXIMATELY 5 L/MIN

Next: !p720, f721

DHW POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: p722, !f723

RESISTANCE DHW SENSOR

DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)

Next: !p726, !f727

BURNER INJECTOR CONDITION

REMOVE GAS RAIL FROM BOILER FOR INSPECTION.

Next: !p732, !f733

SUMMER/WINTER SWITCH RESISTANCE

REMOVE 1 CONNECTOR FROM THE RIGHT HAND SWITCH (PINK LEADS)

Next: p741, !f742

RESISTANCE FLOW SENSOR

DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)

Next: !p756, !f757

GAS VALVE MODULATION RESISTANCE

DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID

Next: !p713, !f105

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: p119, f481

GAS RATE

Next: !p121, f731

DIVERTER VALVE CH POSITION

Next: p589, !f165

DIVERTER VALVE CH POSITION

Next: p606, !f159

CH POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: !p176, !f177

ON/OFF SWITCH VOLTAGE (OUTPUT)

Next: p197, !f184

FUSE F1 RESISTANCE

REMOVE CONTROL BOX COVER
REMOVE FUSE F1 FROM PCB

Next: p638, !f198

FAN FREE TO SPIN

Next: !p220, !f637

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: p247, f241

DHW POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: !p249, !f250

SPARKING AT ELECTRODE

Next: p455, f351

AIR PRESSURE SWITCH AIR DETECT

REMOVE PLASTIC COVER FROM THE PCB
REMOVE AIR PRESSURE SWITCH CONNECTOR FROM M3 ON THE PCB

Next: p621, f355

AIR PRESSURE SWITCH TUBES

Next: p358, !f377

FLUE VENTURI

Next: p360, !f376

FLUE CHECK

Next: !p374, !f375

FAN VOLTAGE

Next: p219, f687

GAS PRESSURE ON IGNITION (BURNER)

ON/OFF SWITCH IN OFF

Next: p626, f417

GAS INLET PRESSURE

ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT

Next: p400, !f401

FLAME SENSE ELECTRODE AND LEAD

DISCONNECT FLAME SENSOR LEAD FROM ELECTRODE AND PCB.

Next: p402, ?404, ?406

FLUE CHECK

Next: p410, !f409

FLUE VENTURI

Next: p43, !f44

CASE FITTED CORRECTLY

Next: !p412, !f411

GAS VALVE MODULATION RESISTANCE

DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID

Next: !p715, !f422

FLUE CHECK

Next: !p45, !f46

GAS INLET PRESSURE DROP

ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT

Next: p456, ?457, ?459

BURNER CONDITION

REMOVE THE BURNER ASSEMBLY FROM THE BOILER.

Next: !p465, !f466

GAS VALVE VOLTAGE

REMOVE PLASTIC COVER FROM THE PCB

Next: p461, !f462

GAS VALVE SOLENOID RESISTANCE

REMOVE THE PLUG FROM THE GAS VALVE.

Next: !p714, !f464

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: p472, f473

DHW POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: !p476, !f477

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: !p495, f496

CH POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: p568, !f569

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: !p570, f571

HEAT EXCHANGER

REMOVE THE BURNER ASSEMBLY FROM THE BOILER.

Next: p399, !f395

GAS PRESSURE - CH

ATTACH U-GAUGE TO GAS VALVE OUTLET PRESSURE TEST POINT

Next: p593, f594

SYSTEM BYPASS

Next: !p603, !f604

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: !p599, f600

SYSTEM BYPASS

Next: !p610, !f611

CH POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: p613, !f618

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: !p617, f614

ELECTRODE LEAD INSPECTION

DISCONNECT ELECTRODE LEAD FROM PCB AND ELECTRODE.

Next: p622, !f623

BURNER INJECTOR CONDITION

REMOVE GAS RAIL FROM BOILER FOR INSPECTION.

Next: p631, !f628

BURNER CONDITION

REMOVE THE BURNER ASSEMBLY FROM THE BOILER.

Next: p633, !f632

HEAT EXCHANGER

REMOVE THE BURNER ASSEMBLY FROM THE BOILER.

Next: !p634, !f635

LOW WATER PRESSURE SWITCH MADE

LOCATE AND REMOVE CONNECTOR M12 FROM THE PCB

Next: p639, f652

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: p640, f641

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: p644, f645

DIVERTER VALVE MICROSWITCH (RESISTANCE)

DISCONNECT PLUG CONN

Next: p648, !f649

PCB DIVERTER VALVE VOLTS

Next: !p650, !f651

FLOW BLOCKAGE OR DAMAGE

BOILERS DHW CIRCUIT FULLY DRAINED AND DISCHARGED.

Next: !p9, ?11, ?13

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: p705, f706

DHW POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: !p709, !f710

RESISTANCE HARNESS AND DHW SENSOR

DISCONNECT M12 PLUG FROM THE PCB.

Next: !p724, f725

PUMP LIMPET TEST

Next: !p729, !f730

TEST EXTERNAL CONTROLS VOLTAGE SUPPLY

REMOVE CONTROL BOX COVER
REMOVE AND MAKE SAFE ONE WIRE FROM THE M5 - TIMER TERMINAL

Next: p743, !f744

TEST TIMER SWITCHING

REMOVE CONTROL BOX COVER
ON/OFF SWITCH IN THE ON POSITION

Next: p745, !f746

TEST ROOM STAT VOLTAGE SUPPLY

REMOVE CONTROL BOX COVER
REMOVE AND MAKE SAFE ONE WIRE FROM THE M5 - "ROOM STAT" TERMINAL

Next: p747, !f748

TEST ROOM STAT SWITCHING

REMOVE CONTROL BOX COVER

Next: p753, !f750

RESISTANCE HARNESS AND FLOW SENSOR

DISCONNECT SENSOR PLUG FROM THE PCB

Next: p754, f755

CH POTENTIOMETER RESISTANCE

REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11

Next: !p758, !f759

GAS INLET PRESSURE

ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT

Next: p102, !f103