Set Appliance State:
Mains Power Off
| Isolate Mains Power to appliance as per TOP's P4 |
Turn Hot Water Tap On
DHW temperature control to maximum
CH temperature control to minimum
DHW temperature control to maximum
CH temperature control to minimum
Remove plastic cover from the PCB
Measurement:
Allow the fan to run and the ignition sequence to commence.
Expect approx. 100V AC
Check for mains voltage at connector M10 on the PCB across the red and yellow leads.
Expect approx. 100V AC
Check for mains voltage at connector M10 on the PCB across the red and yellow leads.

Isolate as per TOPs P4
and refit as necessary