Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
RAVENHEAT RSF 820-20
WARNING - IMPORTA
EXPANSION VESSEL
MODE SELECTOR SWITCH TO CH POSITION
CENTRAL HEATING
MAIN SWITCH IN ON POSITION
SUMMER/WINTER SWITCH IN WINTER POSITION
HOT WATER
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
CH MODULATION
MAIN SWITCH IN ON PO
CH BURNER IGNITES
MAIN SWITCH IN ON POSITION
SUMMER/WINTER SWITCH IN WINTER POSITION
CH PUMP RUNS
MAIN SWITCH IN ON PO
CH HIGH FAN
MAIN SWITCH IN ON POSITION
SUMMER/WINTER SWITCH IN WINTER POSITION
DHW MODULATION
MAIN SWITCH IN ON PO
DHW BURNER IGNITES
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
DHW PUMP RUNS
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
DHW HIGH FAN
MAIN SWITCH IN ON PO
PILOT IGNITES
GAS ON
PILOT HIGH FAN
MAIN SWITCH IN ON POSITION
ELECTRODE SPARKING
MAIN SWITCH IN ON POSITION
RAVENHEAT RSF 820-20
G.C. NUMBER 47 581 0
SLOW FAN
MAIN SWITCH IN ON POSITION
REMOVE COMBUSTION COVER
HEADER FOR 3 AMP FUSE INVESTIGATION
INTENTIONALLY BLANK - HEADER FOR FUSE INVESTIGATION
BURNER PRESSURE NOT AT A MAXIMUM FROM START
DHW THERMOSTAT
DHW MODULATION
MODULATOR COIL
BURNER PRESSURE DOES NOT REDUCE TO A MINIMUM
DHW THERMOSTAT
BURNER PRESSURE NOT AT MAXIMUM FROM START
HEATING THERMOSTAT
NO DEMAND
PRINTED CIRCUIT BOARD
NOT SWITCHING
CH CONTROLS
CH HIGH FAN
SUMMER/ WINTER SWITCH
PILOT HIGH FAN
PRINTED CIRCUIT BOARD
PILOT HIGH FAN
FAN RESISTOR
STUCK HIGH FAN
DIVERTER VALVE
ELECTRICAL SAFETY CHECKS
ELECTRICAL CHECKS
STUCK ON HIGH FAN
IGNITION MICROSWITCHES
FAN DOES NOT RUN
PRINTED CIRCUIT BOARD
PILOT FLAME FAILURE
GAS VALVE ASSEMBLY
EXPANSION VESSEL
EXPANSION VESSEL
ELECTRODE SPARKING
SPARK ELECTRODE LEAD
ELECTRODE SPARKING
IGNITION MICROSWITCHES
CH BURNER IGNITES
HEATING THERMOSTAT
DHW HIGH FAN
HIGH LIMIT THERMOSTAT
CH PUMP RUNS
PRINTED CIRCUIT BOARD
BLOWN
FUSE MAINS
ELECTRODE SPARKING
FUSE 3 15A
ELECTRODE SPARKING
MAINS SWITCH
BLOWING FUSE
PUMP
BLOWING FUSE
FAN
BLOWING FUSE
GAS VALVE ASSEMBLY
BLOWING FUSE
SPARK GENERATOR
BLOWING FUSE
TIMER
PILOT IGNITES
PILOT INJECTOR
PILOT ESTABLISHED
THERMOCOUPLE & CUTOFF THERMOSTAT
DHW DEMAND
DHW THROTTLE VALVE
DHW DEMAND
DHW FILTER
DHW HIGH FAN
FUSE
DHW HIGH FAN
IGNITION MICROSWITCHES
DHW PUMP RUNS
PRINTED CIRCUIT BOARD
DHW BURNER IGNITES
PRINTED CIRCUIT BOARD
DHW BURNER IGNITES
AIR PRESSURE SWITCH TUBES
DHW BURNER IGNITES
FLUE
DHW BURNER IGNITES
FLUE VENTURI
ELECTRICAL
GAS VALVE ASSEMBLY
DHW MODULATION
DHW MICROSWITCHES
BURNER PRESSURE DOES NOT REDUCE TO MINIMUM
HEATING THERMOSTAT
CH MODULATION
DHW MICROSWITCHES
HOT WATER
DIVERTER VALVE
HOT WATER
HEAT EXCHANGER
CENTRAL HEATING
HEAT EXCHANGER
DHW DEMAND
HEAT EXCHANGER (SCALED)
DHW HIGH FAN MAINS ABSENT
PRINTED CIRCUIT BOARD
CH HIGH FAN
DHW MICROSWITCHES
CH HIGH FAN
HEATING THERMOSTAT
CH HIGH FAN
PRINTED CIRCUIT BOARD
PILOT HIGH FAN
IGNITION MICROSWITCHES
PILOT HIGH FAN
FAN
FAN STUCK ON HIGH
DHW MICROSWITCHES
STUCK ON HIGH FAN
PRINTED CIRCUIT BOARD
SLOW FAN
FAN
SLOW FAN
IGNITION MICROSWITCHES
ELECTRODE SPARKING
SPARK ELECTRODE
ELECTRODE SPARKING
SPARK GENERATOR
DHW HIGH FAN MAINS PRESENT
PRINTED CIRCUIT BOARD
DHW HIGH FAN
DHW MICROSWITCHES
BLANK FOR MAINS FUSE
Z DIRECTION CHOICE OR CONTINUE
BLANK FOR FUSE
Z DIRECTION CHOICE OR CONTINUE
ELECTRODE SPARKING
PRINTED CIRCUIT BOARD
BLOWING FUSE
PCB FUSE BLOWN
PILOT IGNITES
GAS VALVE ASSEMBLY
PILOT ESTABLISHED
GAS VALVE ASSEMBLY
DHW DEMAND
DIVERTER VALVE DIAPHRAGM
DHW PUMP RUNS
PUMP
DHW BURNER IGNITES
AIR PRESSURE SWITCH
DHW BURNER IGNITES
BURNER
MECHANICAL
GAS VALVE ASSEMBLY
BURNER PRESSURE NOT AT MAXIMUM FROM START
CHARACTERISTIC TEST FROM DHW MODULATION
BURNER PRESSURE DOES NOT REDUCE TO MINIMUM
CHARACTERISTIC TEST FROM DHW MODULATION
HW NOISY OPERATION
CHARACTERISTIC TEST FROM HOT WATER
HW QUIET OPERATION & WARM RADIATORS
CHARACTERISTIC TEST FROM HOT WATER
CH NOISY OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH QUIET OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING
FAN RUNS ON HIGH SPEED
CHARACTERISTIC TEST FROM SLOW FAN
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM SLOW FAN
BURNER PRESSURE NOT AT MAXIMUM FROM START
CHARACTERISTIC TEST FROM DHW MODULATION
BURNER PRESSURE DOES NOT REDUCE TO MINIMUM
CHARACTERISTIC TEST FROM DHW MODULATION
30/01/2018 14:28:39 1801_1_50_1 06/03/2018 13:52:59
06/02/2018 09:58:08
OBSERVATION CH HIGH FAN CONTROLS LINKED OUT
FIT A LINK BETWEEN T
WINTER SWITCH VOLTAGE
MAIN SWITCH IN ON PO
RESISTANCE SUMMER / WINTER SWITCH
SUMMER/WINTER SWITCH
FAN RESISTOR IN VOLTAGE SPARKING
MAIN SWITCH IN ON POSITION
RELAY 2A NC VOLTAGE
{GAINPCBACS}
MAIN SWITCH IN ON POSITION
RESISTANCE ELECTRODE LEAD
DISCONNECT THE SPARK ELECTRODE LEAD FROM THE ELECTRODE AND FROM THE GENERATOR
RESISTANCE DHW HIGH LIMIT STAT
DISCONNECT LEADS FROM THE HIGH LIMIT STAT
RESISTANCE MAINS FUSE
GAIN ACCESS TO MAINS FUSE
FUSE FURTHER INVESTIGATION (MAINS)
THE INFORMATION PROV
FURTHER INVESTIGATION FUSE 3 15A
THE INFORMATION PROV
SWITCHED MAINS VOLTAGE
{GAINPCBACS}
MAIN SWITCH IN ON POSITION
RESISTANCE PUMP - FUSE INVESTIGATION
REMOVE PUMP COVER
REMOVE WIRES FROM PUMP TERMINALS
THERMOCOUPLE & CUT OFF VOLTAGE
MAIN SWITCH IN ON POSITION
24V AC SUPPLY
{GAINPCBACS}
MAIN SWITCH IN ON POSITION
FUSE
REMOVE FUSE FROM PCB
DHW THERMOSTAT IN VOLTAGE
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
OPERATOR SOLENOID VOLTAGE
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
AIR PRESSURE SWITCH IN VOLTAGE
{GAINPCBACS}
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
GV OPERATOR SOLENOID RESISTANCE
REMOVE ONE WIRE FROM OPERATOR SOLENOID.
DHW THERMOSTAT OUT VOLTAGE
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
HEATING THERMOSTAT 1ST STAGE OUT VOLTAGE
MAIN SWITCH IN ON PO
HEATING THERMOSTAT 2ND STAGE VOLTAGE
MAIN SWITCH IN ON PO
RESISTANCE FAN RESISTOR
DISCONNECT CONNECTIONS FROM FAN RESISTOR
RESISTANCE DHW MICROSWITCH
DISCONNECT THE 4 WAY PLUG AT THE BACK LEFT OF THE PCB
RESISTANCE FAN MICROSWITCH
DISCONNECT THE 4 WAY PLUG AT THE BACK LEFT OF THE PCB
SLOW FAN VOLTAGE
MAIN SWITCH IN ON POSITION
OBSERVATION SPARK ELECTRODE
MAIN SWITCH IN ON PO
VOLTAGE SPARK GENERATOR MAINS INPUT
MAIN SWITCH IN ON POSITION
RESISTANCE FUSE 3 15A
REMOVE FUSE FROM HOLDER ON PCB
MAINS ON/OFF SWITCH RESISTANCE
REMOVE THE TWO UPPER MOST SPADE
CONNECTORS ON THE MAINS ON/OFF SWITCH
RESISTANCE FAN - FUSE INVESTIGATION
REMOVE WIRES FROM FAN ASSEMBLY NOTING THEIR LOCATIONS
RESISTANCE GAS VALVE - FUSE INVESTIGATION
REMOVE THE WIRES FROM THE MAIN SOLENOID
RESISTANCE SPARK GENERATOR FUSE INVESTIGATION
REMOVE THE WIRES FROM THE SPARK GENERATOR
NOTING THEIR LOCATIONS
RESISTANCE INTEGRAL TIMER
REMOVE THE TWO LEFT HAND TIRES TO THE TIMER
DHW FILTER
DHW CIRCUIT DRAINED AND ISOLATED
BOILER PRIMARY CIRCUIT DRAINED AND ISOLATED
RESISTANCE DHW HIGH LIMIT STAT AND MICROSWITCHES
DISCONNECT THE 4 WAY PLUG AT THE BACK LEFT OF THE PCB
TRANSFORMER PRIMARY VOLTAGE
MAIN SWITCH IN ON POSITION
WATER PUMP SUPPLY
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
BURNER PRESSURE
MAIN SWITCH IN ON PO
DHW MODULATION VOLTAGE
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
DHW MODULATION VOLTAGE
MAIN SWITCH IN ON POSITION
HOT WATER CONTROL THERMOSTAT SET TO MAXIMUM
MODULATION COIL RESISTANCE
REMOVE ONE WIRE FROM MODULATION COIL.
System Information
- Total Tests: 160
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control