Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
VOKERA COMPACT A DIN
GLOBALLY REPLACED
OBSERVATION BOILER SELF CHECK
CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE NO DEMANDS & BOILER IS COOL
OBSERVATION FAN RUNS
ENSURE DHW FLOW RATE
PRESSURE GAS INLET (DHW DEMAND)
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
FUSE FURTHER INVESTIGATION
NOT USED
HOW TO CANCEL PURGE CYCLE
CH & DHW TEMPERATURE
FAULT CODE A02
NOT USED
FAULT CODE A04
NOT USED
HOW TO CANCEL PUMP PURGE CYCLE - FAULT CODES
CH & DHW TEMPERATURE
FAULT CODE A03
NOT USED
FAULT CODE A06
NOT USED
FAULT CODE A07
NOT USED
FAULT CODE A08
NOT USED
FAULT CODE A09
NOT USED
FAULT CODE A11
NOT USED
OBSERVATION FAN SPEEDS
{GAINPCBACS}
LOCA
DHW PREHEAT OPERATION
ENSURE THERE IS A DEMAND FOR PREHEAT, BOILER COOL
DIAGNOSTICS LITE
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW
HEADER FOR QUICK ACCESS DATA FLOW THERMISTOR
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA RETURN THERMISTOR
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA GAS VALVE VOLTAGE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA GAS VALVE RESISTANCE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA DHW THERMISTOR
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA PUMP VOLTAGE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA FAN RESISTANCE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA FAN VOLTAGE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR RESISTANCE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA SPARK GENERATOR VOLTAGE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA DIVERTER VOLTAGE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA DIVERTER RESISTANCE
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL
OUTSIDE MODEL
HEADER FOR QUICK ACCESS DATA PUMP RESISTANCE (ERP)
OUTSIDE MODEL
BOILER FIRES NO DEMAND
DOMESTIC PLUMBING
BOILER FIRES NO DEMAND
ACTUATOR - DHW
USER CONTROLS
Z REDIRECT
DHW FLOW RATE
STOP COCK - WATER SUPPLY
DHW FLOW RATE
COLD WATER SUPPLY
PUMP DOES NOT RUN
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
CONDENSATE
BURNER DOES NOT IGNITE
GAS INLET PRESSURE
BURNER DOES NOT IGNITE
PIPE - SUCTION
BURNER DOES NOT IGNITE
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
PIPE - SUCTION
BURNER DOES NOT IGNITE 2
HARNESS - WIRING
BOILER DOES NOT EST
CONDENSATE
BOILER DOES NOT EST
COMPENSATION TUBE
BOILER DOES NOT EST
GAS INLET PRESSURE
BOILER DOES NOT EST 2
ELECTRODE - DETECTION
BOILER DOES NOT EST 2
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
FLUE
BURNER BAFFLES OR NOISY
CONDENSATE
BURNER BAFFLES OR NOISY
COMPENSATION TUBE
BURNER BAFFLES OR NOISY
GAS INLET PRESSURE
BURNER BAFFLES OR NOISY
PIPE - SUCTION
DHW TOO HOT
SENSOR - NTC
DHW COOL RADS COOL
PUMP
DHW COOL RADS COOL
SENSOR - NTC
DHW COOL RADS COOL
DETECTOR - WATER
DHW COOL RADS COOL
PLUMBING ISSUE
DHW COOL RADS COOL
VALVE - BY-PASS
DHW COOL RADS COOL
VALVE - NON RETURN
DHW HOT THEN COOL
PUMP
DHW HOT THEN COOL
SENSOR - NTC
DHW HOT THEN COOL
DETECTOR - WATER
DHW HOT THEN COOL
VALVE - NON RETURN
CH OPERATION
EXPANSION VESSEL
CH OPERATION
COCK - HEATING
CH OPERATION
DETECTOR - WATER
CH OPERATION 2
DETECTOR - WATER
CH OPERATION 2
PUMP
LEDS DO NOT WORK
FUSE (FUSED SPUR)
LEDS DOT NOT WORK
MAINS INPUT FUSE
LEDS DO NOT WORK
FUSE F1
FAULT CODE 2
Z REDIRECT
FAULT CODES
Z REDIRECT
FAULT CODE A02 2
THERMOSTAT - HIGH LIMIT
FAULT CODE A02 2
PRINTED CIRCUIT BOARD
FAULT CODE A02 2
DETECTOR - WATER
FAULT CODE A02
DETECTOR - WATER
FAULT CODE A02
SENSOR - NTC
FAULT CODE A04
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND
MECHANICAL CLOCK
CH DOES NOT RESPOND 3
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND 3
MECHANICAL CLOCK
CH DOES NOT RESPOND 2
PRINTED CIRCUIT BOARD
CH DOES NOT RESPOND 2
MECHANICAL CLOCK
DHW COOL RADS COOL
FLUE
DHW COOL RADS COOL
PIPE - SUCTION
DHW COOL RADS COOL 2
FLUE
DHW COOL RADS COOL 2
PIPE - SUCTION
DHW COOL RADS COOL 2
VALVE - BY-PASS
BOILER DOES NOT EST
ELECTRODE - DETECTION
BURNER DOES NOT IGNITE
ELECTRODE - IGNITION
BURNER DOES NOT IGNITE
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
HARNESS - WIRING
FAULT CODE A02
VALVE - NON RETURN
FAULT CODE A02
HEAT EXCHANGER ASSEMBLY - WATERWAYS
FAULT CODE A02
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
PIPE - SUCTION
CASE REMOVAL
Z REDIRECT
DHW OPERATION 4
PRINTED CIRCUIT BOARD
DHW OPERATION 2
PRINTED CIRCUIT BOARD
DHW OPERATION 3
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 4
HARNESS - WIRING
FAN DOES NOT RUN
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN
FAN
FAN DOES NOT RUN
DETECTOR - WATER
FAN DOES NOT RUN 2
DETECTOR - WATER
FAN DOES NOT RUN
SENSOR - NTC
FAN DOES NOT RUN 2
HARNESS - WIRING
DHW RADS BEGIN TO HEAT 2
PRINTED CIRCUIT BOARD
DHW RADS BEGIN TO HEAT 2
HARNESS - WIRING
CH OPERATION 4
PRINTED CIRCUIT BOARD
CH OPERATION 2
HARNESS - WIRING
CH RADS HEAT 2
CARTRIDGE - 3 WAY VALVE
CH OPERATION 3
PUMP
CH OPERATION 2
VALVE - BY-PASS
BOILER FIRES NO DEMAND
DETECTOR - WATER
BOILER FIRES NO DEMAND
SENSOR - NTC
SELF CHECK
PRINTED CIRCUIT BOARD
SELF CHECK 2
PRINTED CIRCUIT BOARD
SELF CHECK
MECHANICAL CLOCK
FAULT CODE A03 5
HARNESS - WIRING
FAULT CODE A03 3
PRINTED CIRCUIT BOARD
FAULT CODE A03 2
FAN
FAULT CODE A03 2
DETECTOR - WATER
FAULT CODE A03
DETECTOR - WATER
FAULT CODE A03
SENSOR - NTC
FAULT CODE A03
HARNESS - WIRING
FAULT CODE A06
HARNESS - WIRING
FAULT CODE A06
PRINTED CIRCUIT BOARD
FAULT CODE A07
DETECTOR - WATER
FAULT CODE A08 2
DETECTOR - WATER
FAULT CODE A08
PRINTED CIRCUIT BOARD
FAULT CODE A09
SENSOR - FLUE
FAULT CODE A07
PRINTED CIRCUIT BOARD
FAULT CODE A07 2
PRINTED CIRCUIT BOARD
FAULT CODE A07 2
PUMP
FAULT CODE A07 2
DETECTOR - WATER
FAULT CODE A07
HEAT EXCHANGER ASSEMBLY - WATERWAYS
FAULT CODE A07
VALVE - NON RETURN
FAULT CODE A07 3
PRINTED CIRCUIT BOARD
FAULT CODE A07
DETECTOR - WATER X2
FAULT CODE A08 2
PRINTED CIRCUIT BOARD
FAULT CODE A08 2
PUMP
FAULT CODE A08
DETECTOR - WATER
FAULT CODE A08
HEAT EXCHANGER ASSEMBLY - WATERWAYS
FAULT CODE A08
VALVE - NON RETURN
FAULT CODE A08
DETECTOR - WATER X2
FAULT CODE A08 3
PRINTED CIRCUIT BOARD
FAULT CODE AO9
PRINTED CIRCUIT BOARD
FAULT CODE A09
PRINTED CIRCUIT BOARD
FAULT CODE A09 2
PUMP
FAULT CODE A09
DETECTOR - WATER
FAULT CODE A11
CONDENSATE
FAULT CODE A11
FLUE
FAULT CODE A11 2
PRINTED CIRCUIT BOARD
FAN SPEED
FAN SPEED INCORRECT
DISABLE PREHEAT
Z REDIRECT
PREHEAT 2
PRINTED CIRCUIT BOARD
FAULT CODE A11 2
GAS VALVE
FAULT CODE A11 2
ELECTRODE - DETECTION
BOILER FIRES NO DEMAND 2
HARNESS - WIRING
BURNER DOES NOT IGNITE
THERMOSTAT - HIGH LIMIT
NO DISPLAY
THERMOSTAT - HIGH LIMIT
ONLY 1 ATTEMPT TO IGNITE
SENSOR - PRESSURE
ONLY 1 ATTEMPT TO IGNITE
THERMOSTAT - HIGH LIMIT
BLANK FOR DIAGNOSICS LITE
Z REDIRECT
BLANK FOR QUICK ACCESS DATA AND INFORMATION
Z REDIRECT
OUT OF RANGE (QADAI)
DETECTOR - WATER
OUT OF RANGE (QADAI) 2
DETECTOR - WATER
NO POWER TO GAS VALVE (QADAI)
PRINTED CIRCUIT BOARD
RESISTANCE WRONG (QADAI)
GAS VALVE
QADAI
SENSOR - NTC
QADAI
SENSOR - FLUE
NO POWER TO FAN (QADAI)
PRINTED CIRCUIT BOARD
NO POWER TO PUMP (QADAI)
PRINTED CIRCUIT BOARD
INCORRECT RESISTANCE (QADAI)
TRANSFORMER - IGNITION
NO VOLTAGE TO SPARK GEN (QADAI)
PRINTED CIRCUIT BOARD
INCORRECT RESISTANCE (QADAI)
ACTUATOR
NO VOLTAGE TO DIVERTER (QADAI)
PRINTED CIRCUIT BOARD
FAULT CODE A03 (QADAI)
HARNESS - WIRING
NO DISPLAY
SENSOR - PRESSURE
QADAI
PUMP
OBSERVATION PUMP RUNS - ERP PUMP
HARNESS - WIRING
FAULT CODE A02 - ERP PUMP
HARNESS - WIRING
FAULT CODE A07 - ERP PUMP
HARNESS - WIRING
FAULT CODE A08 - ERP PUMP
HARNESS - WIRING
FAULT A09 - ERP PUMP
HARNESS - WIRING
RESISTANCE SPARK GENERATOR ERP PUMP
TRANSFORMER - IGNITION
FUSE FURTHER INVESTIGATION ERP PUMP
ACTUATOR
FUSE INVESTIGATION
PUMP
BURNER DOES NOT IGNITE
HARNESS & PRINTED CIRCUIT BOARD
FUSE FURTHER INVESTIGATION 5 ERP PUMP
HARNESS - WIRING
GAS INLET DHW DEMAMD
GAS INLET PRESSURE
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
BOILER FIRES NO DEMAND
PRINTED CIRCUIT BOARD
BOILER FIRES NO DEMAND
HARNESS - WIRING
DHW FLOW RATE
HEAT EXCHANGER - PLATE
DHW FLOW RATE
GOVERNOR - FLOW
DHW FLOW RATE
ACTUATOR - DHW
DHW FLOW RATE
INLET FILTER - DHW
BURNER DOES NOT IGNITE 2
GAS VALVE
BURNER DOES NOT IGNITE 2
BURNER ASSEMBLY
BURNER DOES NOT IGNITE 2
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BOILER DOES NOT EST
HARNESS - WIRING
BOILER DOES NOT EST 2
HARNESS - WIRING
BURNER BAFFLES OR NOISY
GAS VALVE
BURNER BAFFLES OR NOISY
BURNER ASSEMBLY
BURNER BAFFLES OR NOISY
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW TOO HOT
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
HEAT EXCHANGER - PLATE
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
DHW HOT THEN COOL
PRINTED CIRCUIT BOARD
DHW HOT THEN COOL
HEAT EXCHANGER - PLATE
DHW HOT THEN COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
CH OPERATION
PIPE - FLEXIBLE
CH OPERATION 3
PRINTED CIRCUIT BOARD
CH OPERATION
PRESSURE GAUGE
CH OPERATION
SYSTEM PRESSURE
CH OPERATION 2
PRESSURE GAUGE
CH OPERATION 2
SYSTEM PRESSURE
DHW HOT THEN COOL
PRESSURE GAUGE
DHW HOT THEN COOL
SYSTEM PRESSURE
DHW COOL RADS COOL
PRESSURE GAUGE
DHW COOL RADS COOL
SYSTEM PRESSURE
FUSE FIURTHER INVESTIGATION 2
Z REDIRECT
LEDS DO NOT WORK
HARNESS - WIRING
FUSE FIURTHER INVESTIGATION
Z REDIRECT
FUSE FIURTHER INVESTIGATION 3
Z REDIRECT
FAULT CODE
Z REDIRECT
FAULT CODE A02 3
PRINTED CIRCUIT BOARD
FAULT CODE A02 2
HARNESS - WIRING
FAULT CODE A02
PRESSURE GAUGE
FAULT CODE A02
SYSTEM PRESSURE
FAULT CODE A02
THERMOSTAT - HIGH LIMIT
FAULT CODE RED A02
PRINTED CIRCUIT BOARD
FAULT CODE A04
HARNESS - WIRING
FAULT CODE A04
SENSOR - PRESSURE
FAULT CODE A04
PRESSURE GAUGE
FAULT CODE A04
SYSTEM PRESSURE
FAULT CODE A04
FAULT CODE RESET - RETEST BOILER OPERATION
DHW COOL RADS COOL 2
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
BURNER ASSEMBLY
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL 2
BURNER ASSEMBLY
DHW COOL RADS COOL 2
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL 3
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
BURNER ASSEMBLY
BOILER DOES NOT EST
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BOILER DOES NOT EST 3
ELECTRODE - DETECTION
BOILER DOES NOT EST
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
BURNER ASSEMBLY
BURNER DOES NOT IGNITE
HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BURNER DOES NOT IGNITE 2
ELECTRODE - IGNITION
BURNER DOES NOT IGNITE
GAS VALVE
BURNER DOES NOT IGNITE
TRANSFORMER - IGNITION
FAULT CODE A02
HEAT EXCHANGER - PLATE
FAULT CODE A02
FAULT CODE - A02 - A07 -A08
FAN DOES NOT RUN
ACTUATOR - DHW
FAN DOES NOT RUN
GOVERNOR - FLOW
FAN DOES NOT RUN 2
ACTUATOR - DHW
FAN DOES NOT RUN
INLET FILTER - DHW
FAN DOES NOT RUN 4
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 5
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN
HARNESS - WIRING
FAN DOES NOT RUN 2
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 3
HARNESS - WIRING
FAN DOES NOT RUN
SENSOR - PRESSURE
FAN DOES NOT RUN
PRESSURE GAUGE
FAN DOES NOT RUN
SYSTEM PRESSURE
FAN DOES NOT RUN 3
PRINTED CIRCUIT BOARD
DHW RADS BEGIN TO HEAT 2
CARTRIDGE - 3 WAY VALVE
DHW RADS BEGIN TO HEAT 3
ACTUATOR
CH OPERATION 2
ACTUATOR
BOILER FIRES NO DEMAND
FROST PROTECTION MODE
BOILER FIRES NO DEMAND 2
PRINTED CIRCUIT BOARD
FAULT CODE A03 3
FAN
FAULT CODE A03 3
HARNESS - WIRING
FAULT CODE A03
PRINTED CIRCUIT BOARD
FAULT CODE A03 2
HARNESS - WIRING
FAULT CODE A03
SENSOR - PRESSURE
FAULT CODE A03
PRESSURE GAUGE
FAULT CODE A03
SYSTEM PRESSURE
FAULT CODE A03 2
PRINTED CIRCUIT BOARD
FAULT CODE A03
FAN
FAULT CODE A06
SENSOR - NTC
FAULT CODE A06
FAULT CODE RESET - RETEST BOILER OPERATION
FAULT CODE A07
HARNESS - WIRING
FAULT CODE AO8
HARNESS - WIRING
FAULT CODE A09
HARNESS - WIRING
FAULT CODE A07
PRESSURE GAUGE
FAULT CODE A07
SYSTEM PRESSURE
FAULT CODE A07
HEAT EXCHANGER - PLATE
FAULT CODE A07
FAULT CODE - A02 - A07 -A08
FAULT CODE A08
PRESSURE GAUGE
FAULT CODE A08
SYSTEM PRESSURE
FAULT CODE A08
HEAT EXCHANGER - PLATE
FAULT CODE A08
FAULT CODE - A02 - A07 -A08
FAULT CODE A09
PRESSURE GAUGE
FAULT CODE A09
SYSTEM PRESSURE
FAULT CODE A09
FAULT CODE RESET - A09
FAULT CODE A09 2
SENSOR - FLUE
FAULT CODE A09
HEAT EXCHANGER ASSEMBLY
FAULT CODE A11
ELECTRODE - DETECTION
FAULT CODE A11
FAULT CODE RESET - RETEST BOILER OPERATION
BOILER FIRES NO DEMAND 3
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE 2
PRINTED CIRCUIT BOARD
ONL Y 1 ATTEMPT TO IGNITE
PRINTED CIRCUIT BOARD
FLOW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
RETURN THERMISTOR SATISFACTORY
RESULT AS EXPECTED
GAS VALVE VOLTAGE SATISFACTORY
RESULT AS EXPECTED
GAS VALVE RESISTANCE SATISFACTORY
RESULT AS EXPECTED
DHW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
FLUE THERMISTOR SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR SATISFACTORY
RESULT AS EXPECTED
FAN VOLTAGE SATISFACTORY
RESULT AS EXPECTED
PUMP VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FAN RESISTANCE SATISFACTORY
RESULT AS EXPECTED
SPARK GENERATOR VOLTAGE SATISFACTORY
RESULT AS EXPECTED
DIVERTER RESISTANCE SATISFACTORY
RESULT AS EXPECTED
DIVERTER VOLTAGE SATISFACTORY
RESULT AS EXPECTED
FAULT CODE A03 (QADAI)
PRINTED CIRCUIT BOARD
FAULT CODE A03 2 (QADAI)
PRINTED CIRCUIT BOARD
FAN SPEED CONTROL RESISTANCE SATISFACTORY
RESULT AS EXPECTED
FAN SPEED CONTROL VOLTAGE SATISFACTORY
RESULT AS EXPECTED
PUMP RESISTANCE SATISFACTORY ERP
RESULT AS EXPECTED
LEDS DO NOT WORK
PRINTED CIRCUIT BOARD
FAULT CODE A02
PUMP
FAULT CODE A07
PUMP
FAULT CODE A08
PUMP
FAULT CODE A09
PUMP
FUSE FURTHER INVESTIGATION 2 ERP PUMP
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 3 ERP PUMP
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 4 ERP PUMP
HARNESS - WIRING
OBSERVATION GAS VALVE TYPE? ERP PUMP
PRINTED CIRCUIT BOARD - FUSE BLOWN
FUSE FURTHER INVESTIGATION
HARNESS - WIRING
BURNER DOES NOT IGNITE
SOLENOID - GAS VALVE & PRINTED CIRCUIT BOARD
FUSE FURTHER INVESTIGATION ERP PUMP
SOLENOID
FAULT CODE / NOTIFICATION PRESENT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
DISPLAY DOES NOT OPERATE
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BOILER ATTEMPTS TO FIRE AFTER SELF CHECK WITH PREHEAT DISABLED
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
BOILER GOES TO FAULT CODE A02 BEFORE 75 °C
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
TEMPERATURE EXCEEDS 85 °C & CONTINUES TO FIRE
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
DETECTION ELECTRODE - INCORRECT GAP AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS
BURNER RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
IGNITION ELECTRODE - INCORRECT GAP AND/OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
FROST SYMBOL DISPLAYED
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY
RADIATOR SYMBOL DISPLAYED
CHARACTERISTIC TEST FROM OBSERVATION DISPLAY
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
FAULT CODE A09 OCCURS - FLUE GAS TEMPERATURE BELOW 90°C
CHARACTERISTIC TEST FROM OBSERVATION FLUE GAS TEMPERATURE
FLUE TEMPERATURE EXCEEDS 90°C & BOILER STILL FIRING
CHARACTERISTIC TEST FROM OBSERVATION FLUE GAS TEMPERATURE
BOILER GOES TO IGNITION LOCKOUT (A01) AFTER ONLY 1 ATTEMPT AT IGNITION
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
TEST 1 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
TEST 2 - VOLTAGE NOT AS EXPECTED
CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
BOILER REACHES TEMPERATURE - RADIATORS DO NOT HEAT OR ONLY GET WARM
CHARACTERISTIC TEST FROM CH OPERATION
BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW - BOILER REMAINS LIT
CHARACTERISTIC TEST FROM CH OPERATION
EXCESSIVE SYSTEM PRESSURE RISE AS SYSTEM HEATS
CHARACTERISTIC TEST FROM CH OPERATION
DHW COOL - RADIATORS REMAIN COOL OR DO NOT INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW COOL - RADIATORS BEGIN TO HEAT OR INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
DHW RUNS HOT THEN COOL
CHARACTERISTIC TEST FROM DHW OPERATION
20/03/2023 13:26:04 2212_1_46_1 21/06/2023 10:45:03
22/03/2023 08:24:55
ISOLATED COLD FEED (BOILER)
ISOLATE COLD FEED TO BOILER
ENSURE NO DEMANDS
RESISTANCE DHW FLOW SWITCH
REMOVE CONNECTORS TO THE DHW FLOW SWITCH
ENSURE NO DEMANDS
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
VOLTAGE DETECTION ELECTRODE AT PCB
{GAINPCBACS}
VOLTAGE DETECTION ELECTRODE DISCONNECTED AT PCB
REMOVE DETECTION ELECTRODE CONNECTION FA2
FROM THE PCB & MAKE SAFE
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE P
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE P
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE FUSED SPUR
REMOVE FUSE FROM FUSED SPUR
FUSE FURTHER INVESTIGATION - FUSED SPUR
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - MAINS INPUT
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - F1 PCB FUSE
THE INFORMATION PROV
RESISTANCE PUMP AND HARNESS (ERP)
REMOVE CONNECTOR CN2 FROM THE PCB
RESET APPLIANCE
ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL
RESISTANCE OVERHEAT STAT & HARNESS
REMOVE CONNECTOR CN11 FROM THE PCB
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
DISCONNECT EXTERNAL CONTROLS - CH OPERATION
{GAINPCBACS}
DISC
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
0TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)
ATTACH TEMPERATURE P
VOLTAGE DHW FLOW SENSOR - DEMAND
GAIN ACCESS TO DHW FLOW SENSOR CONNECTIONS
VOLTAGE FAN - POWER SUPPLY AT PCB
{GAINPCBACS}
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
VOLTAGE DIVERTER VALVE AT PCB (CH)
{GAINPCBACS}
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
DISCONNECT EXTERNAL CONTROLS - SELF CHECK
{GAINPCBACS}
DISCONNECT EXTERNAL CONTROLS FROM CONNECTOR CN5 & MAKE SAFE
OBSERVATION FAN RUNS
ENSURE DHW FLOW RATE
VOLTAGE FAN - POWER SUPPLY AT PCB
{GAINPCBACS}
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR HARNESS
REMOVE ELECTRICAL CONNECTOR TO DHW TEMPERATURE SENSOR
& CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS - (FAULT CODE)
REMOVE CONNECTOR CN11 FROM THE PCB
ENSURE BOILER IS COOL
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS - (FAULT CODE)
REMOVE CONNECTOR CN11 FROM THE PCB
ENSURE BOILER IS COOL
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE FLUE TEMPERATURE SENSOR & HARNESS - (FAULT CODE)
REMOVE CONNECTOR CN11 FROM THE PCB
ENSURE BOILER IS COOL
RESISTANCE FLUE TEMPERATURE SENSOR
REMOVE CONNECTOR FROM THE FLUE SENSOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
0TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)
ATTACH TEMPERATURE P
VOLTAGE PUMP AT PCB
{GAINPCBACS}
0TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)
ATTACH TEMPERATURE P
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESET APPLIANCE - FAULT CODE A11
ENSURE NO DEMANDS ARE PRESENT
OBSERVATION DETECTION ELECTRODE DISCONNECTED
REMOVE LEAD TO DETECTION ELECTRODE & MAKE SAFE
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB & ELECTRICAL CONNECTOR AT GAS VALVE
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE FLUE TEMPERATURE SENSOR
REMOVE CONNECTOR FROM THE FLUE SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS (QADAI)
REMOVE CONNECTOR CN9 FROM THE PCB
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE FAN
REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
VOLTAGE DIVERTER VALVE AT PCB (QADAI)
{GAINPCBACS}
RESISTANCE DIVERTER VALVE ACTUATOR
REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE FAN SPEED CONTROL AND HARNESS (QADAI)
{GAINPCBACS}
DISCONNECT CN10 AT PCB
RESISTANCE PUMP (ERP)
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY
RESISTANCE FAN
REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.
RESISTANCE DIVERTER VALVE ACTUATOR
REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB & ELECTRICAL CONNECTOR AT GAS VALVE
RESISTANCE PUMP (ERP)
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY
VOLTAGE MAINS INPUT - PCB
{GAINPCBACS}
DISCONNECT DHW FLOW SWITCH
DISCONNECT LEADS TO THE DHW FLOW SWITCH & MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE DHW FLOW SWITCH & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
ENSURE NO DEMANDS
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
OBSERVATION GAS VALVE OPENS
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
ENSURE NO DEMANDS
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
OBSERVATION SPARKING OCCURS
REMOVE ELECTRODE LEA
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB & ELECTRICAL CONNECTOR AT GAS VALVE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
VOLTAGE DETECTION ELECTRODE
GAIN ACCESS TO DETECTION ELECTRODE CONNECTION
ENSURE NO DEMANDS
INSPECTION DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
INSPECTION EXPANSION VESSEL PRESSURE
DRAIN BOILER PRIMARY SYSTEM WATER
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE FUSE - PCB
REMOVE FUSE FROM PCB
RESISTANCE FUSE - MAINS INPUT
REMOVE MAINS INPUT FUSE FROM TERMINAL BLOCK
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
OBSERVATION CH - OVERHEAT OCCUR
ATTACH FGA TEMPERATURE CLAMP TO THE FLOW PIPE
RESET APPLIANCE - FAULT CODE A04
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
DISCONNECT TIMER - CH OPERATION
{GAINPCBACS}
DISC
RESISTANCE TIMER SWITCH
LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE
INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION IGNITION ELECTRODE AND LEAD
REMOVE IGNITION ELECTRODE FROM BOILER
RESISTANCE SPARK GENERATOR HARNESS
REMOVE CN1 FROM THE PCB
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
OBSERVATION DISCONNECT LOW WATER PRESSURE SWITCH
REMOVE ELECTRICAL CONNECTORS FROM THE LOW WATER PRESSURE SWITCH AND MAKE SAFE
RESISTANCE HARNESS DHW FLOW SENSOR
REMOVE CONNECTOR CN9 FROM THE PCB
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
INSPECTION DIVERTER VALVE SPINDLE
ACTUATOR REMOVED AND PRIMARY WATER DRAINED FROM PREVIOUS TEST
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
OBSERVATION DISPLAY
ENSURE NO DEMANDS PRESENT
TEMPERATURE FLOW PIPE - FROST PROTECTION
ATTACH FGA TEMPERATURE SENSOR TO THE BOILER'S
FLOW PIPE NEAR THE FLOW THERMISTOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
DISCONNECT TIMER/PROGRAMMER- SELF CHECK
{GAINPCBACS}
DISCONNECT WIRES FROM CONNECTOR CN5 & MAKE SAFE
RESISTANCE TIMER SWITCH - SELF CHECK
ENSURE NO CH DEMAND
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
VOLTAGE FAN - SIGNAL CONTROL
{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR CN9 FROM THE PCB
RESET APPLIANCE - FAULT CODE (SENSORS)
ENSURE NO DEMANDS ARE PRESENT
RESET APPLIANCE - FAULT CODE (SENSORS)
ENSURE NO DEMANDS ARE PRESENT
RESET APPLIANCE - FAULT CODE (SENSORS)
ENSURE NO DEMANDS ARE PRESENT
RESET APPLIANCE - FAULT CODE (SENSORS)
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
OBSERVATION FLUE GAS TEMPERATURE
INSERT TEMPERATURE PROBE INTO FLUE GAS TEST POINT
INSPECTION DETECTION ELECTRODE - FAULT CODE A11
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE HARNESS DHW FLOW SENSOR (SELF CHECK)
DISCONNECT LEADS ON THE DHW FLOW SWITCH
REMOVE CONNECTOR CN9 FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
OBSERVATION DISCONNECT OVERHEAT STAT
REMOVE ELECTRICAL CONNECTORS FROM THE OVERHEAT STAT AND MAKE SAFE
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS
RESISTANCE OVERHEAT STAT
REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT
RESISTANCE FAN HARNESS
REMOVE SIGNAL CONTRO
DISCONNECT FAN SPEED CONTROL CONNECTOR
REMOVE FAN SPEED CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE PUMP HARNESS (ERP)
REMOVE CONNECTOR FROM PUMP AND UNCLIP
COVER TO EXPOSE ELECTRICAL CONNECTIONS
RESISTANCE PUMP HARNESS (ERP)
REMOVE CONNECTOR FROM PUMP AND UNCLIP
COVER TO EXPOSE ELECTRICAL CONNECTIONS
RESISTANCE PUMP HARNESS (ERP)
REMOVE CONNECTOR FROM PUMP AND UNCLIP
COVER TO EXPOSE ELECTRICAL CONNECTIONS
RESISTANCE PUMP HARNESS (ERP)
REMOVE CONNECTOR FROM PUMP AND UNCLIP
COVER TO EXPOSE ELECTRICAL CONNECTIONS
RESISTANCE PUMP HARNESS (ERP)
REMOVE CONNECTOR FROM PUMP AND UNCLIP
COVER TO EXPOSE ELECTRICAL CONNECTIONS
RESISTANCE FAN AND HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE DIVERTER VALVE ACTUATOR & HARNESS
REMOVE CONNECTOR CN4 FROM THE PCB
RESISTANCE GAS VALVE AND HARNESS - FUSE
REMOVE CONNECTOR CN2 FROM THE PCB
System Information
- Total Tests: 694
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control