Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove electrical connector to diverter actuator
Measurement:
Measure for resistance across the actuator terminals as per table below:
| Isolate Mains Power to appliance as per TOPs P4 |
| Black test probe | Red test probe | Resistance |
| Pin 2 | Pin 1 | 7.0 - 8.5 Kohms or open circuit |
| Pin 2 | Pin 3 | 7.0 - 8.5 Kohms or open circuit |
Isolate as per TOPs P4
and refit as necessary