VOKERA COMPACT 25

GLOBALLY REPLACED

Next: &1, *

INFORMATION CASE REMOVAL

Next: &3, !f2

OBSERVATION BOILER SELF CHECK

CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE NO DEMANDS & BOILER IS COOL

Next: &1039, ?1009, ?1011, ?1013

DHW FLOW RATE

Next: &89, f1041

OBSERVATION FAN RUNS

CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE BOILER IS COOL

Next: &103, f1053

OBSERVATION PUMP RUNS

Next: &216, f1187

OBSERVATION BURNER IGNITION & ESTABLISH

Next: &356, ?217, ?219, ?221, ?2343

PRESSURE GAS INLET (DHW DEMAND)

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: &763, !f357

CH OPERATION

Next: &nff, ?359, ?361, ?363, ?365

FUSE FURTHER INVESTIGATION

NOT USED

Next: &nff, f1608

DHW OPERATION

Next: &358, ?764, ?766, ?768, ?770

HOW TO CANCEL PURGE CYCLE

CH & DHW TEMPERATURE

Next: &73, !f1040

FAULT CODE SOLID RED

BLANK

Next: &nff, f1769

FAULT CODE RED BLINKING

BLANK

Next: &nff, f1729

FAULT CODE GREEN & RED FLASHING

BLANK

Next: &nff, f1799

HOW TO CANCEL PUMP PURGE CYCLE - FAULT CODES

CH & DHW TEMPERATURE

Next: &nff, !f1692

PREHEAT ENABLED

NOT USED

Next: &nff, f1863

COMBUSTION MODE

NOT USED

Next: &nff, f1867

NEW QADAI OPTIONS

OUTSIDE MODEL

Next: &nff, ?2193, ?2195, ?2197, ?2199, ?2201, ?2203, ?2205, ?2207, ?2209, ?2211, ?2213, ?2215, ?2217, ?2219, ?2221, ?2223, ?2225, ?2227, ?2229

BOILER FIRES NO DEMAND

DOMESTIC PLUMBING

Next: End

BOILER FIRES NO DEMAND

ACTUATOR - DHW

Next: End

BOILER FIRES NO DEMAND

DETECTOR - WATER

Next: End

BOILER FIRES NO DEMAND

SENSOR - NTC

Next: End

USER CONTROLS

Z REDIRECT

Next: End

DHW FLOW RATE

COCK STOP - WATER SUPPLY

Next: End

DHW FLOW RATE

COLD WATER SUPPLY

Next: End

FAN DOES NOT RUN 4

HARNESS - WIRING

Next: End

FAN DOES NOT RUN

FAN

Next: End

FAN DOES NOT RUN

DETECTOR - WATER

Next: End

FAN DOES NOT RUN 2

DETECTOR - WATER

Next: End

FAN DOES NOT RUN

SENSOR - NTC

Next: End

FAN DOES NOT RUN

PRINTED CIRCUIT BOARD

Next: End

PUMP DOES NOT RUN

PRINTED CIRCUIT BOARD

Next: End

PUMP DOES NOT RUN

HARNESS - WIRING

Next: End

BURNER DOES NOT IGNITE

CONDENSATE

Next: End

BURNER DOES NOT IGNITE

GAS INLET PRESSURE

Next: End

BURNER DOES NOT IGNITE

PIPE - SUCTION

Next: End

BURNER DOES NOT IGNITE

COMPENSATION TUBE

Next: End

BURNER DOES NOT IGNITE 2

COMPENSATION TUBE

Next: End

BURNER DOES NOT IGNITE 2

PIPE - SUCTION

Next: End

BURNER DOES NOT IGNITE 2

HARNESS - WIRING

Next: End

BURNER DOES NOT IGNITE

FLUE

Next: End

BOILER DOES NOT EST

CONDENSATE

Next: End

BOILER DOES NOT EST

COMPENSATION TUBE

Next: End

BOILER DOES NOT EST

GAS INLET PRESSURE

Next: End

BOILER DOES NOT EST 2

ELECTRODE - DETECTION

Next: End

BOILER DOES NOT EST 2

PRINTED CIRCUIT BOARD

Next: End

BOILER DOES NOT EST

FLUE

Next: End

BURNER BAFFLES OR NOISY

CONDENSATE

Next: End

BURNER BAFFLES OR NOISY

COMPENSATION TUBE

Next: End

BURNER BAFFLES OR NOISY

FLUE

Next: End

BURNER BAFFLES OR NOISY

GAS INLET PRESSURE

Next: End

BURNER BAFFLES OR NOISY

PIPE - SUCTION

Next: End

DHW TOO HOT

SENSOR - NTC

Next: End

DHW COOL RADS COOL

PUMP

Next: End

DHW COOL RADS COOL

SENSOR - NTC

Next: End

DHW COOL RADS COOL

DETECTOR - WATER

Next: End

DHW COOL RADS COOL

PLUMBING ISSUE

Next: End

DHW COOL RADS COOL

BY-PASS VALVE - DHW

Next: End

DHW COOL RADS COOL

VALVE - NON RETURN

Next: End

DHW HOT THEN COOL

PUMP

Next: End

DHW HOT THEN COOL

SENSOR - NTC

Next: End

DHW HOT THEN COOL

DETECTOR - WATER

Next: End

DHW HOT THEN COOL

VALVE - NON RETURN

Next: End

CH OPERATION

EXPANSION VESSEL

Next: End

CH OPERATION

COCK 3/4 IN - HEATING - WATER

Next: End

CH OPERATION

DETECTOR - WATER

Next: End

CH OPERATION 2

DETECTOR - WATER

Next: End

CH OPERATION 2

PUMP

Next: End

RESISTANCE SPARK GENERATOR

TRANSFORMER - IGNITION

Next: End

FUSE FURTHER INVESTIGATION 2

GAS VALVE

Next: End

FUSE FURTHER INVESTIGATION

ACTUATOR

Next: End

FAULT CODE 2

Z REDIRECT

Next: End

FAULT CODES

Z REDIRECT

Next: End

FAULT CODE RED SOLID

THERMOSTAT - HIGH LIMIT

Next: End

FAULT CODE RED SOLID 2

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE RED SOLID 2

HARNESS - WIRING

Next: End

FAULT CODE RED SOLID 2

PUMP

Next: End

FAULT CODE RED SOLID

DETECTOR - WATER

Next: End

FAULT CODE RED SOLID 2

DETECTOR - WATER

Next: End

FAULT CODE RED SOLID

SENSOR - NTC

Next: End

FAULT CODE SOLID RED

DETECTOR - WATER

Next: End

FAULT CODE SOLID RED 2

DETECTOR - WATER

Next: End

FAULT CODE SOLID RED 3

HARNESS - WIRING

Next: End

FAULT CODE BLINKING RED GREEN 2

DETECTOR - WATER

Next: End

FAULT CODE BLINKING RED GREEN

DETECTOR - WATER

Next: End

FAULT CODE BLINKING RED GREEN

SENSOR - FLUE

Next: End

FAULT CODE BLINKING RED GREEN

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE GREEN BLINKING

PRINTED CIRCUIT BOARD

Next: End

CH DOES NOT RESPOND

PRINTED CIRCUIT BOARD

Next: End

CH DOES NOT RESPOND

MECHANICAL CLOCK

Next: End

CH DOES NOT RESPOND 3

PRINTED CIRCUIT BOARD

Next: End

CH DOES NOT RESPOND 3

MECHANICAL CLOCK

Next: End

CH DOES NOT RESPOND 2

PRINTED CIRCUIT BOARD

Next: End

CH DOES NOT RESPOND 2

MECHANICAL CLOCK

Next: End

FAULT CODE SOLID RED 4

HARNESS - WIRING

Next: End

PREHEAT

PRINTED CIRCUIT BOARD

Next: End

COMBUSTION MODE

PRINTED CIRCUIT BOARD

Next: End

DHW COOL RADS COOL

FLUE

Next: End

DHW COOL RADS COOL

PIPE - SUCTION

Next: End

DHW COOL RADS COOL 2

FLUE

Next: End

DHW COOL RADS COOL 2

PIPE - SUCTION

Next: End

DHW COOL RADS COOL 2

BY-PASS VALVE - DHW

Next: End

BOILER DOES NOT EST

ELECTRODE - DETECTION

Next: End

BURNER DOES NOT IGNITE

ELECTRODE - IGNITION

Next: End

FAN DOES NOT RUN 2

HARNESS - WIRING

Next: End

BURNER DOES NOT IGNITE

PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

HARNESS - WIRING

Next: End

FAULT CODE RED BLINKING

VALVE - NON RETURN

Next: End

FAULT CODE RED BLINKING

HEAT EXCHANGER ASSEMBLY - WATERWAYS

Next: End

FAULT CODE RED SOLID 3

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE BLINKING RED GREEN 4

HARNESS - WIRING

Next: End

BOILER DOES NOT EST

PIPE - SUCTION

Next: End

CASE REMOVAL

Z REDIRECT

Next: End

DHW OPERATION 4

PRINTED CIRCUIT BOARD

Next: End

DHW OPERATION 2

PRINTED CIRCUIT BOARD

Next: End

DHW OPERATION 3

PRINTED CIRCUIT BOARD

Next: End

FUSE FURTHER INVESTIGATION

SOLENOID

Next: End

DHW RADS BEGIN TO HEAT 2

PRINTED CIRCUIT BOARD

Next: End

DHW RADS BEGIN TO HEAT 2

HARNESS - WIRING

Next: End

CH OPERATION 4

PRINTED CIRCUIT BOARD

Next: End

CH OPERATION 2

HARNESS - WIRING

Next: End

CH OPERATION 3

PUMP

Next: End

CH OPERATION 2

BY-PASS VALVE - DHW

Next: End

DHW RADS BEGIN TO HEAT

PRINTED CIRCUIT BOARD

Next: End

CH OPERATION

HARNESS - WIRING

Next: End

CH OPERATION 2

PRINTED CIRCUIT BOARD

Next: End

CH OPERATION

PUMP

Next: End

CH OPERATION

BY-PASS VALVE - DHW

Next: End

DHW RADS BEGIN TO HEAT

HARNESS - WIRING

Next: End

CH RADS HEAT

CARTRIDGE

Next: End

CH RADS HEAT 2

CARTRIDGE

Next: End

FAULT CODE RED SOLID

SENSOR - FLUE

Next: End

FAULT CODE RED SOLID 6

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE RED SOLID 3

FAN

Next: End

FAULT CODE RED SOLID 5

HARNESS - WIRING

Next: End

FAULT CODE RED SOLID 5

PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

GAS VALVE & PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

SOLENOID - GAS VALVE & PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

THERMOSTAT - HIGH LIMIT

Next: End

NO VOLTAGE TO DIVERTER (QADAI)

PRINTED CIRCUIT BOARD

Next: End

INCORRECT RESISTANCE (QADAI)

ACTUATOR

Next: End

NO VOLTAGE TO SPARK GEN (QADAI)

PRINTED CIRCUIT BOARD

Next: End

INCORRECT RESISTANCE (QADAI)

TRANSFORMER - IGNITION

Next: End

FAULT CODE A03 (QADAI)

HARNESS - WIRING

Next: End

NO POWER TO FAN (QADAI)

PRINTED CIRCUIT BOARD

Next: End

NO POWER TO PUMP (QADAI)

PRINTED CIRCUIT BOARD

Next: End

NO POWER TO GAS VALVE (QADAI)

PRINTED CIRCUIT BOARD

Next: End

QADAI

SENSOR - FLUE

Next: End

QADAI

SENSOR - NTC

Next: End

OUT OF RANGE (QADAI) 2

DETECTOR - WATER

Next: End

OUT OF RANGE (QADAI)

DETECTOR - WATER

Next: End

DIAG LITE 2

Z REDIRECT

Next: End

QADAI 1

Z REDIRECT

Next: End

QADAI RESISTANCE SIEMENS

GAS VALVE

Next: End

QADAI RESISTANCE SIT

GAS VALVE

Next: End

LEDS DO NOT WORK

FUSE (FUSED SPUR)

Next: End

LEDS DOT NOT WORK

MAINS INPUT FUSE

Next: End

LEDS DO NOT WORK

FUSE F1

Next: End

ONLY 1 ATTEMPT TO IGNITE

SENSOR - PRESSURE

Next: End

ONLY 1 ATTEMPT TO IGNITE

THERMOSTAT - HIGH LIMIT

Next: End

GAS INLET DHW DEMAMD

GAS INLET PRESSURE

Next: End

TYPE OF DIAGNOSTIC PROCEDURE

Z REDIRECT

Next: End

BOILER FIRES NO DEMAND

PRINTED CIRCUIT BOARD

Next: End

BOILER FIRES NO DEMAND

HARNESS - WIRING

Next: End

BOILER FIRES NO DEMAND

FROST PROTECTION MODE

Next: End

BOILER FIRES NO DEMAND 2

PRINTED CIRCUIT BOARD

Next: End

DHW FLOW RATE

HEAT EXCHANGER - PLATE

Next: End

DHW FLOW RATE

GOVERNOR - FLOW

Next: End

DHW FLOW RATE

ACTUATOR - DHW

Next: End

DHW FLOW RATE

INLET FILTER - DHW

Next: End

FAN DOES NOT RUN 3

PRINTED CIRCUIT BOARD

Next: End

FAN DOES NOT RUN 3

HARNESS - WIRING

Next: End

FAN DOES NOT RUN

SENSOR - PRESSURE

Next: End

FAN DOES NOT RUN 4

PRINTED CIRCUIT BOARD

Next: End

FAN DOES NOT RUN

ACTUATOR - DHW

Next: End

FAN DOES NOT RUN

GOVERNOR - FLOW

Next: End

FAN DOES NOT RUN 2

ACTUATOR - DHW

Next: End

FAN DOES NOT RUN

INLET FILTER - DHW

Next: End

FAN DOES NOT RUN

HARNESS - WIRING

Next: End

PUMP DOES NOT RUN

PUMP

Next: End

BURNER DOES NOT IGNITE 2

GAS VALVE

Next: End

BURNER DOES NOT IGNITE 2

BURNER ASSEMBLY

Next: End

BURNER DOES NOT IGNITE 2

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

BOILER DOES NOT EST

HARNESS - WIRING

Next: End

BOILER DOES NOT EST 2

HARNESS - WIRING

Next: End

BURNER BAFFLES OR NOISY

GAS VALVE

Next: End

BURNER BAFFLES OR NOISY

BURNER ASSEMBLY

Next: End

BURNER BAFFLES OR NOISY

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

DHW TOO HOT

PRINTED CIRCUIT BOARD

Next: End

DHW COOL RADS COOL

PRINTED CIRCUIT BOARD

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER - PLATE

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER ASSEMBLY - WATERWAYS

Next: End

DHW HOT THEN COOL

PRINTED CIRCUIT BOARD

Next: End

DHW HOT THEN COOL

HEAT EXCHANGER - PLATE

Next: End

DHW HOT THEN COOL

HEAT EXCHANGER ASSEMBLY - WATERWAYS

Next: End

CH OPERATION

PIPE

Next: End

CH OPERATION 3

PRINTED CIRCUIT BOARD

Next: End

CH OPERATION

PRESSURE GAUGE

Next: End

CH OPERATION

SYSTEM PRESSURE

Next: End

CH OPERATION 2

PRESSURE GAUGE

Next: End

CH OPERATION 2

SYSTEM PRESSURE

Next: End

DHW HOT THEN COOL

PRESSURE GAUGE

Next: End

DHW HOT THEN COOL

SYSTEM PRESSURE

Next: End

DHW COOL RADS COOL

PRESSURE GAUGE

Next: End

DHW COOL RADS COOL

SYSTEM PRESSURE

Next: End

FAN DOES NOT RUN

PRESSURE GAUGE

Next: End

FAN DOES NOT RUN

SYSTEM PRESSURE

Next: End

FUSE FURTHER INVESTIGATION

HARNESS - WIRING

Next: End

FUSE FURTHER INVESTIGATION 2

PRINTED CIRCUIT BOARD - FUSE BLOWN

Next: End

OBSERVATION GAS VALVE TYPE?

PRINTED CIRCUIT BOARD - FUSE BLOWN

Next: End

FUSE FURTHER INVESTIGATION 3

HARNESS - WIRING

Next: End

FUSE FURTHER INVESTIGATION 2

HARNESS - WIRING

Next: End

FUSE FURTHER INVESTIGATION 4

HARNESS - WIRING

Next: End

FUSE FURTHER INVESTIGATION 5

HARNESS - WIRING

Next: End

FUSE FURTHER INVESTIGATION 6

HARNESS - WIRING

Next: End

FAULT CODE

Z REDIRECT

Next: End

FAULT CODE RED SOLID

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE RED SOLID

HARNESS - WIRING

Next: End

FAULT CODE RED SOLID

PRESSURE GAUGE

Next: End

FAULT CODE RED SOLID

SYSTEM PRESSURE

Next: End

FAULT CODE RED SOLID

PUMP

Next: End

FAULT CODE RED SOLID 2

THERMOSTAT - HIGH LIMIT

Next: End

FAULT CODE RED SOLID 4

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE SOLID RED

HARNESS - WIRING

Next: End

FAULT CODE SOLID RED 2

HARNESS - WIRING

Next: End

FAULT CODE SOLID RED

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE SOLID RED

FAULT CODE RESET - RETEST BOILER OPERATION

Next: End

FAULT CODE SOLID RED

Z REDIRECT

Next: End

FAULT CODE BLINKING RED GREEN 2

HARNESS - WIRING

Next: End

FAULT CODE BLINKING RED GREEN

HARNESS - WIRING

Next: End

FAULT CODE BLINKING RED GREEN 3

HARNESS - WIRING

Next: End

FAULT CODE BLINKING RED GREEN

FAULT CODE RESET - RETEST BOILER OPERATION

Next: End

FAULT CODE GREEN BLINKING

HARNESS - WIRING

Next: End

FAULT CODE GREEN BLINKING

SENSOR - PRESSURE

Next: End

FAULT CODE GREEN BLINKING

PRESSURE GAUGE

Next: End

FAULT CODE GREEN BLINKING

SYSTEM PRESSURE

Next: End

FAULT CODE GREEN BLINKING

FAULT CODE RESET - RETEST BOILER OPERATION

Next: End

FAULT CODE SOLID RED

FAN

Next: End

PREHEAT

PREHEAT - TURNED OFF

Next: End

COMBUSTION

COMBUSTION MODE - CANCELLED

Next: End

DHW COOL RADS COOL 2

PRINTED CIRCUIT BOARD

Next: End

DHW COOL RADS COOL

BURNER ASSEMBLY

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

DHW COOL RADS COOL 2

BURNER ASSEMBLY

Next: End

DHW COOL RADS COOL 2

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

DHW COOL RADS COOL 3

PRINTED CIRCUIT BOARD

Next: End

BOILER DOES NOT EST

BURNER ASSEMBLY

Next: End

BOILER DOES NOT EST

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

BOILER DOES NOT EST 3

ELECTRODE - DETECTION

Next: End

BOILER DOES NOT EST

PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

BURNER ASSEMBLY

Next: End

BURNER DOES NOT IGNITE

HEAT EXCHANGER ASSEMBLY - FLUEWAYS

Next: End

BURNER DOES NOT IGNITE 2

ELECTRODE - IGNITION

Next: End

BURNER DOES NOT IGNITE

GAS VALVE

Next: End

FAN DOES NOT RUN 2

PRINTED CIRCUIT BOARD

Next: End

FAN DOES NOT RUN 2

FAN

Next: End

BURNER DOES NOT IGNITE

TRANSFORMER - IGNITION

Next: End

FAULT CODE RED BLINKING 2

HEAT EXCHANGER - PLATE

Next: End

FAULT CODE RED SOLID

FAULT CODE - OVERHEAT

Next: End

FAULT CODE BLINKING RED GREEN 2

SENSOR - NTC

Next: End

DHW OPERATION 4

Next: End

DHW OPERATION 2

Next: End

DHW OPERATION 3

Next: End

DHW RADS BEGIN TO HEAT 2

CARTRIDGE

Next: End

DHW RADS BEGIN TO HEAT 3

ACTUATOR

Next: End

CH OPERATION 2

ACTUATOR

Next: End

CH OPERATION 2

Next: End

CH OPERATION

ACTUATOR

Next: End

CH OPERATION

Next: End

DHW RADS BEGIN TO HEAT

CARTRIDGE

Next: End

DHW RADS BEGIN TO HEAT 2

ACTUATOR

Next: End

FAULT CODE RED SOLID 3

HARNESS - WIRING

Next: End

FAULT CODE RED SOLID 6

HARNESS - WIRING

Next: End

FAULT CODE RED SOLID 2

FAN

Next: End

BURNER DOES NOT IGNITE 3

PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE 2

HARNESS & PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE 2

PRINTED CIRCUIT BOARD

Next: End

BURNER DOES NOT IGNITE

HARNESS & PRINTED CIRCUIT BOARD

Next: End

STOPPING PRESEQ BREAKING

Z DIRECTION

Next: End

DIVERTER VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

DIVERTER RESISTANCE SATISFACTORY

RESULT AS EXPECTED

Next: End

SPARK GENERATOR VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

SPARK GENERATOR SATISFACTORY

RESULT AS EXPECTED

Next: End

FAN SPEED CONTROL RESISTANCE SATISFACTORY

RESULT AS EXPECTED

Next: End

FAULT CODE A03 (QADAI)

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE A03 2 (QADAI)

PRINTED CIRCUIT BOARD

Next: End

FAN SPEED CONTROL VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

FAN VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

FAN RESISTANCE SATISFACTORY

RESULT AS EXPECTED

Next: End

PUMP VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

PUMP RESISTANCE SATISFACTORY

RESULT AS EXPECTED

Next: End

GAS VALVE VOLTAGE SATISFACTORY

RESULT AS EXPECTED

Next: End

FLUE THERMISTOR SATISFACTORY

RESULT AS EXPECTED

Next: End

DHW THERMISTOR SATISFACTORY

RESULT AS EXPECTED

Next: End

RETURN THERMISTOR SATISFACTORY

RESULT AS EXPECTED

Next: End

FLOW THERMISTOR SATISFACTORY

RESULT AS EXPECTED

Next: End

DIAG LITE 1

Z REDIRECT

Next: End

QADAI 2

Z REDIRECT

Next: End

GAS VALVE RESISTANCE SATISFACTORY (SIEMENS)

RESULT AS EXPECTED

Next: End

GAS VALVE RESISTANCE SATISFACTORY (SIT)

RESULT AS EXPECTED

Next: End

LEDS DO NOT WORK

Next: End

FUSE FIURTHER INVESTIGATION 2

Z REDIRECT

Next: End

LEDS DO NOT WORK

HARNESS - WIRING

Next: End

FUSE FIURTHER INVESTIGATION

Z REDIRECT

Next: End

FUSE FIURTHER INVESTIGATION 3

Z REDIRECT

Next: End

NO LEDS NO FAN

PRINTED CIRCUIT BOARD

Next: End

LEDS DO NOT WORK

PRINTED CIRCUIT BOARD

Next: End

SHORT TO EARTH NO DISPLAY

SENSOR - PRESSURE

Next: End

LED DOES NOT WORK

FAN

Next: End

SHORT TO EARTH NO DISPLAY

THERMOSTAT - HIGH LIMIT

Next: End

ONL Y 1 ATTEMPT TO IGNITE

PRINTED CIRCUIT BOARD

Next: End

FAULT CODE / NOTIFICATION PRESENT

CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK

Next: p1646

LEDS DO NOT ILLUMINATE

CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK

Next: p2288

BOILER ATTEMPTS TO FIRE AFTER SELF CHECK COMPLETE - NO DEMAND PRESENT

CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK

Next: p1014

1 FLOW RESTRICTOR BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1048

2 FLOW SENSOR BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1050

3 DHW INLET FILTER BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1052

TEST 1 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: p1061

TEST 1 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: !p1932

TEST 2 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: p1136

TEST 2 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: p1176

1 FLOW RESTRICTOR BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1180

2 FLOW SENSOR BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1182

3 DHW INLET FILTER BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS

Next: !p1184

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1294

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1296

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1389

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1391

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1509

DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH

CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: !p1481

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1841

DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH

CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

Next: !p1504

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1553

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1556

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1558

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1560

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1562

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1564

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1566

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1568

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1570

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1572

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1739

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1741

BOILER GOES TO FAULT CODE RED LED BLINKING BEFORE 80 °C

CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR

Next: !p1759

TEMPERATURE EXCEEDS 85 °C & CONTINUES TO FIRE

CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR

Next: !p1761

BOILER ATTEMPTS TO IGNITE 5 TIMES BEFORE LOCKOUT OCCURS

CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED

Next: !p1796

FAN RUNS - FAULT CODE OCCURS APPROXIMATELY 15 SECONDS AFTER FAN STARTS

CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED

Next: p1859

PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1831

SYSTEM PRESSURE LOW

CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM

Next: !p1833

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1884

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1886

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1895

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1897

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1907

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1909

DETECTION ELECTRODE - INCORRECT GAP AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS

Next: !p1911

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1921

HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

Next: !p1923

IGNITION ELECTRODE - INCORRECT GAP AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS

Next: !p1925

FAN DOES NOT RUN

CHARACTERISTIC TEST FROM OBSERVATION - FAULT CODE SOLID RED LED

Next: p2137

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p1193

BURNER IGNITES BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p1316

HEADER FOR DIAGNOSTICS LITE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2269

HEADER FOR QUICK ACCESS DATA AND INFORMATION

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2270

HEADER FOR QUICK ACCESS DATA FLOW THERMISTOR

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2198

HEADER FOR QUICK ACCESS DATA RETURN THERMISTOR

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2200

HEADER FOR QUICK ACCESS DATA DHW THERMISTOR

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2202

HEADER FOR QUICK ACCESS DATA GAS VALVE VOLTAGE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2206

HEADER FOR QUICK ACCESS DATA GAS VALVE RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2275

HEADER FOR QUICK ACCESS DATA PUMP RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2210

BURNER IGNITES BUT BAFFLES OR IS NOISY

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p1376

HEADER FOR QUICK ACCESS DATA PUMP VOLTAGE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2212

HEADER FOR QUICK ACCESS DATA FAN RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2214

HEADER FOR QUICK ACCESS DATA FAN VOLTAGE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2216

HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2218

HEADER FOR QUICK ACCESS DATA FAN SPEED CONTROL RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2220

HEADER FOR QUICK ACCESS DATA SPARK GENERATOR RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2222

HEADER FOR QUICK ACCESS DATA SPARK GENERATOR VOLTAGE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2224

HEADER FOR QUICK ACCESS DATA DIVERTER RESISTANCE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2226

HEADER FOR QUICK ACCESS DATA DIVERTER VOLTAGE

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: p2228

NEEDED OR PRESEQ MESSES UP DIVERTER VOLTAGE FOR SOME REASON

CHARACTERISTIC TEST FROM NEW QADAI OPTIONS

Next: !p2230

TEST 1 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: !p2244

TEST 2 - VOLTAGE NOT AS EXPECTED

CHARACTERISTIC TEST FROM VOLTAGE FAN - SIGNAL CONTROL

Next: !p2246

LEDS STOP WORKING WHEN CN9 RECONNECTED

CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS

Next: !p2338

LEDS STOP WORKING WHEN C10 RECONNECTED

CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS

Next: !p2340

LEDS STOP WORKING WHEN CN11 RECONNECTED

CHARACTERISTIC TEST FROM OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS

Next: !p2342

BOILER GOES TO SOLID RED LOCKOUT AFTER ONLY ONE IGNITION ATTEMPT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p2345

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1850

BOILER REACHES TEMPERATURE - RADIATORS DO NOT HEAT OR ONLY GET WARM

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1522

BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW - BOILER REMAINS LIT

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1538

EXCESSIVE SYSTEM PRESSURE RISE AS SYSTEM HEATS

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1519

DHW COOL - RADIATORS REMAIN COOL OR DO NOT INCREASE IN TEMPERATURE

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1417

DHW COOL - RADIATORS BEGIN TO HEAT OR INCREASE IN TEMPERATURE

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p2010

DHW TOO HOT

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1396

DHW RUNS HOT THEN COOL

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1483

ISOLATED COLD FEED (BOILER)

ISOLATE COLD FEED TO BOILER
ENSURE NO DEMANDS

Next: p1023, !f1024

RESISTANCE DHW FLOW SWITCH

DISCONNECT 1X ELECTRICAL CONNECTOR TO THE DHW FLOW SWITCH
ENSURE NO DEMANDS

Next: !p1027, !f1028

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1033, !f1034

VOLTAGE DHW FLOW SENSOR - DEMAND

GAIN ACCESS TO DHW FLOW SENSOR CONNECTIONS

Next: p1054, ?1060, ?1175

VOLTAGE FAN - POWER SUPPLY AT PCB

Next: !p1186, !f1185

RESISTANCE LOW WATER PRESSURE SWITCH

REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS

Next: !p1145, f1146

OBSERVATION PRESSURE SYSTEM

Next: !p1164, ?1569, ?1571

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p1188, !f1189

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}

Next: p1275, f2168

VOLTAGE DETECTION ELECTRODE AT PCB

{GAINPCBACS}

Next: !p1341, f1342

VOLTAGE DETECTION ELECTRODE DISCONNECTED AT PCB

REMOVE DETECTION ELECTRODE CONNECTION FA2
FROM THE PCB & MAKE SAFE

Next: p1351, !f1354

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: p1473, ?1478, ?1480

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: p1497, ?1501, ?1503

DISCONNECT EXTERNAL CONTROLS - CH OPERATION

{GAINPCBACS}
DISC

Next: !p2004, !f2005

RESISTANCE PUMP AND HARNESS

REMOVE CONNECTOR CN2 FROM THE PCB

Next: p1609, f1610

RESISTANCE PUMP

REMOVE PUMP ELECTRICAL COVER
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY

Next: !p1611, !f1612

RESISTANCE FAN

REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY

Next: !p1639, !f1643

RESISTANCE SPARK GENERATOR

REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.

Next: !p1638, !f1624

RESISTANCE DIVERTER VALVE ACTUATOR

REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR

Next: !p1640, !f1645

RESISTANCE GAS VALVE AND HARNESS (SIEMENS - VALVE) - FUSE

REMOVE CONNECTOR CN2 FROM THE PCB

Next: !p1631, f1632

RESISTANCE GAS VALVE (SIT - VALVE) - FUSE

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p1641, !f2009

RESISTANCE GAS VALVE (SIEMENS - VALVE) - FUSE

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p1642, !f1637

RESET APPLIANCE

ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL

Next: p1730, f1731

RESISTANCE OVERHEAT STAT & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: !p1732, f1733

RESISTANCE OVERHEAT STAT

REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT

Next: !p1734, !f1735

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p1744, !f1745

RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p1770, f1771

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: !p1772, !f1773

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: !p1776, !f1777

RESISTANCE WIRING HARNESS CN11

REMOVE CONNECTOR CN11 FROM THE PCB

Next: !p1792, !f1793

RESISTANCE FLUE TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p1800, f1819

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: !p1803, !f1804

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: !p1807, !f1808

RESISTANCE FLUE TEMPERATURE SENSOR

REMOVE CONNECTOR FROM THE FLUE SENSOR

Next: !p1820, !f1821

RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1825, f1826

RESISTANCE LOW WATER PRESSURE SWITCH

REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS

Next: !p1827, f1828

OBSERVATION PRESSURE SYSTEM

Next: !p1829, ?1830, ?1832

DISCONNECT EXTERNAL CONTROLS - CH OPERATION

{GAINPCBACS}
DISC

Next: !p2002, !f2003

DISCONNECT EXTERNAL CONTROLS - CH OPERATION

{GAINPCBACS}
DISC

Next: !p2006, !f2007

OBSERVATION - PREHEAT TURNED OFF

DISENGAGE DHW CONTRO

Next: !p1864, !f1865

VOLTAGE SPARK GENERATOR AT PCB

{GAINPCBACS}

Next: p1939, !f1938

TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: p1954, !f1959

RESISTANCE DHW TEMPERATURE SENSOR HARNESS

REMOVE ELECTRICAL CONNECTOR TO DHW TEMPERATURE SENSOR
& CONNECTOR CN9 FROM THE PCB

Next: !p1970, !f1971

OBSERVATION DIVERTER VALVE OPERATION DHW (2X LOCKING PIN)

REMOVE ACTUATOR FROM THE 3-WAY VALVE ASSEMBLY & PLACE IN A SAFE POSITION TO OBSERVE ITS OPERATION

Next: !p2020, f2021

VOLTAGE DIVERTER VALVE AT PCB

{GAINPCBACS}

Next: p2022, !f2023

OBSERVATION DIVERTER VALVE OPERATION CH (2X LOCKING PIN)

REMOVE ACTUATOR FROM THE 3-WAY VALVE ASSEMBLY & PLACE IN A SAFE POSITION TO OBSERVE ITS OPERATION

Next: p2109, f2042

VOLTAGE DIVERTER VALVE AT PCB (CH)

{GAINPCBACS}

Next: p2043, !f2044

RESISTANCE ACTUATOR HARNESS

REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR

Next: !p2081, !f2082

RESISTANCE ACTUATOR HARNESS

REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR

Next: !p2102, !f2103

RESISTANCE FLUE TEMPERATURE SENSOR

REMOVE CONNECTOR FROM THE FLUE SENSOR

Next: !p2131, !f2132

VOLTAGE FAN - POWER SUPPLY AT PCB

Next: !p2140, !f2141

RESISTANCE OVERHEAT STAT

REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT

Next: p2180, !f2191

RESISTANCE GAS VALVE AND HARNESS (SIEMENS - VALVE)

REMOVE CONNECTOR CN2 FROM THE PCB

Next: !p2183, f2184

RESISTANCE GAS VALVE (SIEMENS - VALVE)

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p2185, !f2186

RESISTANCE GAS VALVE (SIT - VALVE)

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p2189, !f2190

RESISTANCE GAS VALVE (SIEMENS - VALVE)

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p2286, !f2279

VOLTAGE MAINS INPUT - PCB

{GAINPCBACS}

Next: p2311, f2312

VOLTAGE MAINS INPUT - BOILER

Next: p2313, f2314

RESISTANCE FUSED SPUR

REMOVE FUSE FROM FUSED SPUR

Next: !p2315, f2316

FUSE FURTHER INVESTIGATION - FUSED SPUR

THE INFORMATION PROV

Next: !p2317, !f2318

FUSE FURTHER INVESTIGATION - MAINS INPUT

THE INFORMATION PROV

Next: !p2321, !f2322

FUSE FURTHER INVESTIGATION - F1 PCB FUSE

THE INFORMATION PROV

Next: !p2325, !f2326

DISCONNECT DHW FLOW SWITCH

DISCONNECT 1X CONNECTOR TO THE DHW FLOW SWITCH & MAKE SAFE
ENSURE NO DEMANDS

Next: p1021, f1022

DISCONNECT EXTERNAL CONTROLS

{GAINPCBACS}
DISCONNECT EXTERNAL CONTROLS FROM CONNECTOR CN5 & MAKE SAFE
NO DEMANDS

Next: p1029, !f1030

RESISTANCE DHW FLOW SWITCH & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB
ENSURE NO DEMANDS

Next: !p1025, f1026

TEMPERATURE FLOW PIPE - FROST PROTECTION

ATTACH FGA TEMPERATURE SENSOR TO THE BOILER'S FLOW PIPE

Next: !p1031, f1032

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: !p1035, !f1036

OBSERVATION COLD WATER SUPPLY

Next: p1044, !f1045

INSPECTION DHW FLOW COMPONENTS

DRAIN THE DOMESTIC H

Next: !p1046, ?1047, ?1049, ?1051

RESISTANCE HARNESS DHW FLOW SENSOR

REMOVE CONNECTOR CN9 FROM THE PCB

Next: !p1174, !f1063

VOLTAGE FAN - SIGNAL CONTROL

{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS

Next: p1929, ?1070, ?1072

FAN RUNS - SIGNAL CONTROL DISCONNECTED

REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p1064, !f1098

RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1137, f1144

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1138, !f1139

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: p1140, !f1141

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: !p1142, !f1143

INSPECTION DHW FLOW COMPONENTS

DRAIN THE DOMESTIC H

Next: !p1177, ?1179, ?1181, ?1183

RESISTANCE PUMP HARNESS

REMOVE CONNECTOR CN2 FROM THE PCB
DISCONNECT ELECTRICAL CONNECTIONS AT PUMP

Next: !p1192, !f1191

INSPECTION CONDENSATE

Next: p1215, !f1195

OBSERVATION GAS VALVE OPENS

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
ENSURE NO DEMANDS

Next: p1231, f1219

PRESSURE GAS INLET

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p1194, !f1218

OBSERVATION SPARKING OCCURS

REMOVE ELECTRODE LEA

Next: p1257, f1936

INSPECTION AIR INTAKE

Next: p1918, !f1239

INSPECTION COMPENSATION TUBE

Next: p1232, !f1271

INSPECTION COMPENSATION TUBE

Next: p1284, !f1277

INSPECTION AIR INTAKE

Next: p1305, !f1291

INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: !p1292, ?1293, ?1295

RESISTANCE GAS VALVE HARNESS

REMOVE CONNECTOR CN2 FROM THE PCB & ELECTRICAL CONNECTOR AT GAS VALVE

Next: p1285, !f1304

INSPECTION FLUE

Next: p1297, !f1315

INSPECTION CONDENSATE

Next: p1317, !f1318

INSPECTION COMPENSATION TUBE

Next: p1972, !f1320

PRESSURE GAS INLET

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p1321, !f1322

VOLTAGE DETECTION ELECTRODE

ENSURE NO DEMANDS

Next: p1904, f1324

INSPECTION DETECTION ELECTRODE

REMOVE DETECTION ELECTRODE

Next: !p1352, !f1353

INSPECTION FLUE

Next: p1319, !f1375

INSPECTION CONDENSATE

Next: p1377, !f1378

INSPECTION COMPENSATION TUBE

Next: p1379, !f1380

INSPECTION FLUE

Next: p1385, !f1382

PRESSURE GAS INLET

ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT

Next: p1383, !f1384

INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: !p1386, ?1388, ?1390

INSPECTION AIR INTAKE

Next: p1381, !f1392

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: !p1397, !f1398

OBSERVATION PRESSURE SYSTEM

Next: p1426, ?1565, ?1567

PUMP LIMPET TEST

Next: p1420, !f1421

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1423, !f1422

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1424, !f1425

TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: p1435, f1472

GAS RATE

Next: p1443, ?1872, ?1874

INSPECTION BY-PASS VALVE

ENSURE BOILER IS COO

Next: !p1446, !f1445

INSPECTION NON-RETURN VALVE

ENSURE BOILER IS COO

Next: !p1475, !f1476

OBSERVATION PRESSURE SYSTEM

Next: p1484, ?1561, ?1563

PUMP LIMPET TEST

Next: p1486, !f1487

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1488, !f1489

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1490, !f1491

TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: !p1496, f1493

INSPECTION NON-RETURN VALVE

ENSURE BOILER IS COO

Next: !p1499, !f1500

DISCONNECT TIMER - CH OPERATION

{GAINPCBACS}
DISC

Next: p1837, !f1838

INSPECTION EXPANSION VESSEL PRESSURE

DRAIN BOILER PRIMARY SYSTEM WATER

Next: !p1520, !f1521

OBSERVATION PRESSURE SYSTEM

Next: p2026, ?1557, ?1559

OBSERVATION PRESSURE SYSTEM

Next: p1545, ?1552, ?1554

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1541, !f1542

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: !p1543, !f1544

PUMP LIMPET TEST

Next: p1539, !f1551

RESISTANCE FAN AND HARNESS

REMOVE CONNECTOR CN3 FROM THE PCB

Next: p1613, f1614

RESISTANCE SPARK GENERATOR AND HARNESS

REMOVE CONNECTOR CN1 FROM THE PCB

Next: p1615, f1616

RESISTANCE DIVERTER VALVE ACTUATOR & HARNESS

REMOVE CONNECTOR CN4 FROM THE PCB

Next: p1617, f1618

OBSERVATION GAS VALVE TYPE?

Next: p1627, f1628

RESISTANCE GAS VALVE AND HARNESS (SIT - VALVE) - FUSE

REMOVE CONNECTOR CN2 FROM THE PCB

Next: !p1633, f1630

FAULT CODE / NOTIFICATION

Next: !p1647, !f1648

OBSERVATION PRESSURE SYSTEM

Next: p1736, ?1738, ?1740

OBSERVATION PUMP RUNS

Next: p1742, f1743

PUMP LIMPET TEST

Next: p1748, !f1749

RESISTANCE PUMP HARNESS

REMOVE CONNECTOR CN2 FROM THE PCB
DISCONNECT ELECTRICAL CONNECTIONS AT PUMP

Next: !p1746, !f1747

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: p1750, !f1751

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: p1752, !f1753

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1942, !f1755

OBSERVATION CH - OVERHEAT OCCUR

ATTACH FGA TEMPERATURE CLAMP TO THE FLOW PIPE

Next: p1962, ?1758, ?1760

RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p2116, f1775

RESET APPLIANCE - SOLID RED LED

ENSURE NO DEMANDS ARE PRESENT

Next: p1790, f1791

OBSERVATION - FAULT CODE SOLID RED LED

Next: !p1794, ?1795, ?1797, ?2135

RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p1801, f1802

RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p1965, f1806

RESET APPLIANCE - RED & GREEN BLINKING

ENSURE NO DEMANDS ARE PRESENT

Next: !p1822, !f1823

RESET APPLIANCE - GREEN LED BLINKING

ENSURE NO DEMANDS ARE PRESENT

Next: !p1834, !f1835

RESISTANCE TIMER SWITCH

LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH

Next: !p1839, !f1840

DISCONNECT TIMER - CH OPERATION

{GAINPCBACS}
DISC

Next: p1846, !f1847

RESISTANCE TIMER SWITCH

LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH

Next: !p1848, !f1849

DISCONNECT TIMER - CH OPERATION

{GAINPCBACS}
DISC

Next: p1855, !f1856

RESISTANCE TIMER SWITCH

LOCATE 2X WIRES WHICH ARE CONNECTED TO THE
INTERNAL TIMER / PROGRAMMER SWITCH

Next: !p1857, !f1858

RESISTANCE FAN HARNESS

REMOVE SIGNAL CONTRO

Next: !p1860, !f1861

INSPECTION FLUE

Next: p1877, !f1878

INSPECTION AIR INTAKE

Next: p1879, !f1880

INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: !p1881, ?1883, ?1885

INSPECTION FLUE

Next: p1888, !f1889

INSPECTION AIR INTAKE

Next: p1890, !f1891

INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: p1898, ?1894, ?1896

INSPECTION BY-PASS VALVE

ENSURE BOILER IS COO

Next: !p1899, !f1900

INSPECTION BURNER, DETECTION ELECTRODE & HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: p1912, ?1906, ?1908, ?1910

INSPECTION DETECTION ELECTRODE

REMOVE DETECTION ELECTRODE

Next: !p1913, !f1914

INSPECTION BURNER, IGNITION ELECTRODE & HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: p1926, ?1920, ?1922, ?1924

INSPECTION IGNITION ELECTRODE AND LEAD

REMOVE IGNITION ELECTRODE FROM BOILER

Next: !p1927, !f1928

RESISTANCE FAN HARNESS

REMOVE SIGNAL CONTRO

Next: !p1933, !f1934

RESISTANCE SPARK GENERATOR HARNESS

REMOVE CN1 FROM THE PCB

Next: !p1940, !f1941

TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER

ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS

Next: p1754, f1953

INSPECTION NON-RETURN VALVE

ENSURE BOILER IS COO

Next: !p1957, !f1958

OBSERVATION PUMP OVERRUN

Next: !p1963, !f1964

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN9 FROM THE PCB

Next: p1805, f1969

INSPECTION AIR INTAKE

Next: p1355, !f1996

OBSERVATION DIVERTER VALVE TYPE

Next: p2055, f2019

RESISTANCE ACTUATOR HARNESS

REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR

Next: !p2024, !f2025

OBSERVATION DIVERTER VALVE TYPE

Next: p2028, f2040

VOLTAGE DIVERTER VALVE AT PCB (CH)

{GAINPCBACS}

Next: p2084, !f2083

PUMP LIMPET TEST

Next: p2047, !f2048

RESISTANCE ACTUATOR HARNESS

REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR

Next: !p2045, !f2046

INSPECTION BY-PASS VALVE

ENSURE BOILER IS COO

Next: !p2049, !f2050

VOLTAGE DIVERTER VALVE AT PCB

{GAINPCBACS}

Next: p2066, !f2057

PUMP LIMPET TEST

Next: p2074, !f2094

INSPECTION BY-PASS VALVE

ENSURE BOILER IS COO

Next: !p2097, !f2098

INSPECTION DIVERTER VALVE SPINDLE (1X LOCKING PIN)

ACTUATOR REMOVED AND PRIMARY WATER DRAINED FROM PREVIOUS TEST

Next: p2096, !f2108

RESISTANCE FLUE TEMPERATURE SENSOR & HARNESS

REMOVE CONNECTOR CN11 FROM THE PCB

Next: p1789, f2130

FAN RUNS - SIGNAL CONTROL DISCONNECTED

REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE

Next: p2142, !f2143

VOLTAGE FAN - SIGNAL CONTROL

{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS

Next: p2144, !f2167

RESISTANCE FAN HARNESS

REMOVE SIGNAL CONTRO

Next: !p2165, !f2166

OBSERVATION GAS VALVE TYPE?

Next: p2181, f2182

RESISTANCE GAS VALVE AND HARNESS (SIT - VALVE)

REMOVE CONNECTOR CN2 FROM THE PCB

Next: !p2187, f2188

RESISTANCE FLOW TEMPERATURE SENSOR

REMOVE CONNECTORS FROM FLOW SENSOR

Next: !p2267, !f2268

RESISTANCE RETURN TEMPERATURE SENSOR

REMOVE CONNECTORS FROM RETURN SENSOR

Next: !p2265, !f2266

RESISTANCE DHW TEMPERATURE SENSOR & HARNESS (QADAI)

REMOVE CONNECTOR CN9 FROM THE PCB

Next: !p2263, !f2264

RESISTANCE FLUE TEMPERATURE SENSOR

REMOVE CONNECTOR FROM THE FLUE SENSOR

Next: !p2261, !f2262

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}

Next: !p2259, !f2260

RESISTANCE PUMP

REMOVE PUMP ELECTRICAL COVER
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY

Next: !p2255, !f2256

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2253, !f2254

RESISTANCE FAN

REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY

Next: !p2251, !f2252

VOLTAGE FAN - POWER SUPPLY AT FAN

Next: !p2249, !f2250

VOLTAGE FAN - SIGNAL CONTROL

{GAINPCBACS}
REMOVE CONNECTOR CN10 FROM THE PCB AND MAKE SAFE
ENSURE NO DEMANDS

Next: p2241, ?2243, ?2245

RESISTANCE FAN SPEED CONTROL AND HARNESS (QADAI)

{GAINPCBACS}
DISCONNECT CN10 AT PCB

Next: !p2239, !f2240

RESISTANCE SPARK GENERATOR

REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.

Next: !p2237, !f2238

VOLTAGE SPARK GENERATOR AT PCB

{GAINPCBACS}

Next: !p2235, !f2236

RESISTANCE DIVERTER VALVE ACTUATOR

REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR

Next: !p2233, !f2234

VOLTAGE DIVERTER VALVE AT PCB (QADAI)

{GAINPCBACS}

Next: !p2231, !f2232

RESISTANCE FAN HARNESS

REMOVE SIGNAL CONTRO

Next: !p2247, !f2248

DIAGNOSTICS LITE

DIAGNOSIS RELIES ON

Next: !p2271, !f2272

QUICK ACCESS DATA AND INFORMATION


THE TABLE BELOW

Next: !p2274, !f2273

OBSERVATION GAS VALVE TYPE? DUMMY

OUTSIDE MODEL

Next: p2276, f2277

RESISTANCE GAS VALVE (SIT - VALVE)

REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE

Next: !p2287, !f2283

OBSERVATION IS FAN RUNNING CONSTANTLY

REMOVE COMBUSTION COVER

Next: p2331, f2310

RESISTANCE FUSE - PCB

REMOVE FUSE FROM PCB

Next: !p2336, f2324

RESISTANCE FUSE - MAINS INPUT

REMOVE MAINS INPUT FUSE FROM TERMINAL BLOCK

Next: !p2319, f2320

OBSERVATION DISCONNECT LOW VOLTAGE COMPONENTS

{GAINPCBACS}
DISC

Next: !p2335, ?2337, ?2339, ?2341

RESISTANCE LOW WATER PRESSURE SWITCH

REMOVE 1X ELECTRICAL CONNECTOR FROM LWPS

Next: p2346, !f2347

RESISTANCE OVERHEAT STAT

REMOVE 1X ELECTRICAL CONNECTOR FROM THE OVERHEAT STAT

Next: !p2348, !f2349