Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN3 from the PCB
Measurement:
Test 1. Measure for resistance across pins blue and brown of connector CN3.
Expected resistance greater than 1Mohm.
Test 2. Measure for resistance across brown and a suitable earth connection.
Expected resistance greater than 1Mohm.
Expected resistance greater than 1Mohm.
Test 2. Measure for resistance across brown and a suitable earth connection.
Expected resistance greater than 1Mohm.

Isolate as per TOPs P4
and refit as necessary