Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
HALSTEAD FINEST / WICKES
GLOBALLY REPLACED
OBSERVATION PUMP AND FAN RUNS
DHW TEMPERATURE SET TO MAX
OBSERVATION BURNER IGNITION
REFIT COMBUSTION CHA
OBSERVATION BOILER RESPONDS TO CH DEMAND
CH TEMPERATURE SET TO MAX
OPERATION DHW
DHW TEMPERATURE SET TO MAX
OPERATION CH
CH TEMPERATURE CONTROL SET TO MAX
OBSERVATION PUMP OVERRUN
CH TEMPERATURE SET TO MAX
FUSE FURTHER INVESTIGATION TREE
OUTSIDE MODEL
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
OBSERVATION DHW MODULATION
ADJUST DHW FLOW RATE
OBSERVATION CH MODULATION
CH TEMPERATURE CONTR
OBSERVATION BOILER STANDBY
ENSURE NO DEMANDS
BAFFLING - FLUEWAYS RESTRICTED
HEAT EXCHANGER
BLOCKED - BAFFLES
BURNER ASSEMBLY
BLOCKED - BAFFLES
FLUE
POWER ON LED NOT ILLUMINATED
MAINS FUSE
FAULTY LED
Z REDIRECT
POWER ON LED NOT ILLUMINATED
FUSE 250V F2AH (F2)
POWER ON LED NO ILLUMINATED
FUSE 250V F2AL (F1)
NO POWER TO PUMP
PCB - COMBINED - PACTROL
OPEN CIRCUIT TO PUMP
HARNESS NO10-15 240V
BLOCKED - APS SHORTED
TUBE 10MM - CLEAR SILICONE
BLOCKED - APS SHORTED
FAN VENTURI
OPEN CIRCUIT TO FAN
HARNESS NO10-15 240V
FAN NOT RUNNING DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
UNABLE TO RESET
THERMOSTAT - OVERHEAT CUT-OFF
RUNNING SLOW - OVERHEAT INVESTIGATION
PUMP 6M - GRUNDFOS UPS 15/16
OVERHEAT INVESTIGATION - WATERWAYS RECTRICTED
HEAT EXCHANGER
RESTRICTED - OVERHEAT INVESTIGATION
PLATE HEAT EXCHANGER - ALFA LAVAL
OVERHEAT INVESTIGATION - NO PUMP OVERRUN
PCB - COMBINED - PACTROL
OPEN CIRCUIT TO APS
HARNESS NO10-15 240V
BLOCKED - SAFETY LED LIT
TUBE 10MM - CLEAR SILICONE
BLOCKED - SAFETY LED LIT
FAN VENTURI
SAFETY LED LIT - FLUEWAYS RESTRICTED
HEAT EXCHANGER
OPEN CIRCUIT
THERMOSTAT - OVERHEAT CUT-OFF
SAFETY LED LIT CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
PUMP PROVING STUCK OPEN FAN SAFETY LED LIT
MICROSWITCH ASSEMBLY
FIRING WITN NO DEMAND CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
FIRING WITH NO DEMAND
TIMER (INTERNAL OR EXTERNAL)
BOILER AND RADIATOR TEMP LOW CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW TOO COOL DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW TOO COOL
INLET PRESSURE
DHW TOO COOL - MODUREG
GAS VALVE - HONEYWELL
DHW TOO COOL - VOLTAGE TO GAS VALVE INCORRECT
PCB - COMBINED - PACTROL
NO IGNITION - NO PRESSURE - RESISTANCE
GAS VALVE - HONEYWELL
NO POWER TO GAS VALVE
PCB - COMBINED - PACTROL
OVERHEAT INVESTIGATION
PCB - CHECK JUMPER
OVERHEAT INVESTIGATION
INLET PRESSURE
OVERHEAT INVESTIGATION - MODUREG
GAS VALVE - HONEYWELL
OVERHEAT INVESTIGATION - VOLTAGE TO GAS VALVE INCORRECT
PCB - COMBINED - PACTROL
OVERHEAT INVESTIGATION - MINIMUM WRONG
GAS VALVE - HONEYWELL
NOT ESTABLISHING - POOR CONDITION
ELECTRODE - DETECTION
BLOCKED - NOT ESTABLISHING
BURNER ASSEMBLY
BLOCKED - NOT ESTABLISHING
INJECTOR
NO IGNITION - LOW PRESSURE - MODUREG
GAS VALVE - HONEYWELL
NOT CHANGING GAS VALVE VOLTAGE - DOES NOT IGNITE
PCB - COMBINED - PACTROL
NOT ESTABLISHING - LOW PRESSURE - MODUREG
GAS VALVE - HONEYWELL
NOT ESTABLISHING - NOT CHANGING GAS VALVE VOLTAGE
PCB - COMBINED - PACTROL
BOILER DOES NOT REACT TO CH DEMAND
PCB - CHECK JUMPER
BOILER DOES NOT REACT TO CH DEMAND NOT RECOGNISING DEMAND
PCB - COMBINED - PACTROL
OVERHEAT INVESTIGATION CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
OVERHEAT INVESTIGATION DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
NOT ESTABLISHING
HARNESS - IGNITION
OPEN CIRCUIT - OVERHEAT INVESTIGATION
HARNESS NO 6 - 9 - CLOCK
BOILER DOES NOT REACT TO CH DEMAND
HARNESS NO 6 - 9 - CLOCK
SHORT CIRCUIT ON MAINS - FUSE INVESTIGATION
HARNESS NO 1 - 5 - MAINS INLET
SHORTED MODULATING SOLNEOID - FUSE INVESTIGATION
GAS VALVE - HONEYWELL
NO SPARKING - POOR CONDITION
ELECTRODE - IGNITION (FROM SN FGX)
NO SPARKING
HARNESS - IGNITION
NO SPARKING - POOR CONDITION
IGNITION ASSEMBLY - OUTER (UP TO SN FG...)
NO SPARKING - OPEN CCT
IGNITION ASSEMBLY - OUTER (UP TO SN FG...)
INSUFFICIENT DHW FLOW RATE
BALL VALVE 15MM
BLOCKED
PIPE - HIGH / LOW PRESSURE DHW
DHW NOT MAKING
MICROSWITCH ASSEMBLY
PUMP NOT RUNNING CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
PUMP NOT RUNNING DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
INSUFFICIENT PRESSURE
WATER SUPPLY
FAN DOES NOT RUN DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
FAN DOES NOT RUN CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW TOO COOL CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW RUNS THEN SAFETY LED LIT
HARNESS NO10-15 240V
DHW RUNS THEN SAFETY LED LIT - BLOCKED
TUBE 10MM - CLEAR SILICONE
DHW RUNS HOT COLD - WATERWAYS RESTRICTED
HEAT EXCHANGER
DHW RUNS HOT COLD - MINIMUM WRONG
GAS VALVE - HONEYWELL
DHW RUNS HOT COLD
INLET PRESSURE
DHW RUNS HOT COLD - MODUREG
GAS VALVE - HONEYWELL
DHW RUNS HOT COLD - VOLTAGE TO GAS VALVE INCORRECT
PCB - COMBINED - PACTROL
DHW RUNS THEN SAFETY LED LIT - FLUEWAYS RESTRICTED
HEAT EXCHANGER
DHW RUNS THEN SAFETY LED LIT - BLOCKED
FAN VENTURI
PUMP PROVING DIAPHRAGM SAFETY LED LIT
KIT - SERVICE - WATER PRESSURE SWITCH
PUMP MICROSWITCH MOVING SLOWLY
KIT - SERVICE - WATER PRESSURE SWITCH / WEEP TUBE
NO IGNITION - LOW PRESSURE
INLET PRESSURE
NO IGNITION - NO PRESSURE
INLET PRESSURE
BLOCKED - NO IGNITION
BURNER ASSEMBLY
NOT ESTABLISHING
INLET PRESSURE
INFORMATION CASE REMOVAL
Z REDIRECT
DHW TOO COOL
KNOB PLASTIC
RUNNING SLOW - DHW TOO COOL
PUMP 6M - GRUNDFOS UPS 15/16
DHW TOO COOL - WATERWAYS RESTRICTED
HEAT EXCHANGER
DHW TOO HOT DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW TOO HOT
KNOB PLASTIC
DHW RUNS HOT COLD DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW RUNS HOT COLD CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
EXCESSIVE PRESSURE RISE
EXPANSION VESSEL
BYPASS STUCK OPEN
MANIFOLD - FLOW
SHUT - BOILER UP TO TEMP RADS COOL
ISOLATION VALVES FLOW AND RETURN
CH STAYS LIT BUT TEMP LOW
KNOB PLASTIC
NO PUMP OVERRUN
PCB - COMBINED - PACTROL
RUNNING SLOW - BOILER UP TO TEMP RADIATORS COOL
PUMP 6M - GRUNDFOS UPS 15/16
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
SHORTED - FUSE INVESTIGATION
PUMP 6M - GRUNDFOS UPS 15/16
SHORTED - FUSE INVESTIGATION
COMBI FAN ASSEMBLY
SHORTED - FUSE INVESTIGATION
GAS VALVE - HONEYWELL
DHW MODULATION
GAS VALVE - HONEYWELL
CH DOES NOT MODULATE CH SENSOR
THERMISTOR 10 OHM - CROSSLAND
DHW DOES NOT MODULATE DHW SENSOR
THERMISTOR 10 OHM - CROSSLAND
RUNNING SLOW - DHW RUNS HOT COLD
PUMP 6M - GRUNDFOS UPS 15/16
FIRING WITH NO DEMAND
FROST PROTECTION
DHW STUCK MADE
MICROSWITCH ASSEMBLY
RUNNING SLOW - BAFFLES
COMBI FAN ASSEMBLY
BOILER UP TO TEMP RADS COOL
KIT - DIVERTER VALVE SERVICE
FIRING WITH NO DEMAND
DIAPHRAGM - DIVERTER VALVE
FIRING WITH NO DEMAND
CHAMBER - DHW DIAPHRAGM
BOILER UP TO TEMP RADS COOL
DIAPHRAGM - DIVERTER VALVE
BOILER UP TO TEMP RADS COOL
CHAMBER - DHW DIAPHRAGM
MAINS FUSE BLOWN
Z REDIRECT
F2 FUSE BLOWN
Z REDIRECT
FAULTY LED
PCB - COMBINED - PACTROL
F1 FUSE BLOWN
Z REDIRECT
POWER ON LED NOT ILLUMINATED
PCB - COMBINED - PACTROL
NOT RUNNING
PUMP 6M - GRUNDFOS UPS 15/16
SHORT CIRCUIT TO APS
HARNESS NO10-15 240V
SHORTED
PRESSURE SWITCH - AIR
SEIZED
COMBI FAN ASSEMBLY
NO POWER TO FAN
PCB - COMBINED - PACTROL
BLOCKED OVERHEAT INVESTIGATION
PRESSURE GAUGE 4 BAR
OVERHEAT INVESTIGATION
SYSTEM PRESSURE
TRIPPING EARLY - OVERHEAT INVESTIGATION
THERMOSTAT - OVERHEAT CUT-OFF
OVERHEAT INVESTIGATION - NOT SHUTTING DOWN
PCB - COMBINED - PACTROL
NO FAULT FOUND
OVERHEAT
BLOCKED SAFETY LED LIT
PRESSURE GAUGE 4 BAR
PUMP PROVING SPINDLE SAFETY LED LIT
SYSTEM PRESSURE
NOT MAKING PUMP PROVING SWITCH SAFETY LED LIT
PUMP 6M - GRUNDFOS UPS 15/16
NOT SWITCHING - SAFETY LED LIT
PRESSURE SWITCH - AIR
RUNNING SLOW - SAFETY LED LIT
COMBI FAN ASSEMBLY
OPEN CIRCUIT TO OVERHEAT
HARNESS NO10-15 240V
SAFETY LED LIT - CH THERMISTOR
HARNESS NO16-31 24V
SAFETY LET LIT
PCB - COMBINED - PACTROL
OPEN CIRCUIT TO PUMP PROVING MICROSWITCH SAFETY LED LIT
HARNESS NO16-31 24V
FIRING WITH NO DEMAND
PCB - COMBINED - PACTROL
CH MODULATION
PCB - COMBINED - PACTROL
CUTTING OUT / MODULATING EARLY - BOILER AND RADIATOR TEMPERATURE LOW
PCB - COMBINED - PACTROL
DHW TOO COOL - MODUREG
HARNESS NO16-31 24V
DHW TOO COOL
GAS VALVE ADJUSTMENT
DHW TOO COOL
GAS VALVE - HONEYWELL
OPEN CIRCUIT TO GAS VALVE
HARNESS NO10-15 240V
NO IGNITION NO PRESSURE
GAS VALVE - HONEYWELL
OVERHEAT INVESTIGATION - MODUREG
HARNESS NO16-31 24V
OVERHEAT INVESTIGATION
GAS VALVE ADJUSTMENT
OVERHEAT INVESTIGATION
GAS VALVE - HONEYWELL
OVERHEAT INVESTIGATION - MINIMUM WRONG
GAS VALVE ADJUSTMENT
NOT RECOGNISING FLAME
PCB - COMBINED - PACTROL
NO IGNITION - LOW PRESSURE - MODUREG
HARNESS NO16-31 24V
NO IGNITION - LOW PRESSURE
GAS VALVE - HONEYWELL
NOT ESTABLISHING - LOW PRESSURE - MODUREG
HARNESS NO16-31 24V
NOT ESTABLISHING - LOW PRESSURE
GAS VALVE - HONEYWELL
NOT ESTABLISHING - OPEN CIRCUIT
ELECTRODE - DETECTION (FROM SN FG...)
SHORT CIRCUIT - FUSE INVESTIGATION
PCB - COMBINED - PACTROL
SHORT CIRCUIT - FUSE INVESTIGATION
HARNESS NO 6 - 9 - CLOCK
FUSE INVESTIGATION MODULATING SOLENOID
HARNESS NO16-31 24V
FURTHER INVESTIGATION
FUSE BLOWN
NO SPARKING - 3 TOTAL
PCB - COMBINED - PACTROL
NO SPARKING - OPEN CCT
ELECTRODE - IGNITION (FROM SN FGX)
NO SPARKING - 2 TOTAL
PCB - COMBINED - PACTROL
NOT ESTABLISHING - OPEN CIRCUIT
IGNITION ASSEMBLY - OUTER (UP TO SN FG...)
NOT MOVING DHW SPINDLE
DIAPHRAGM - DIVERTER VALVE
NOT MOVING SPINDLE
CHAMBER - DHW DIAPHRAGM
DHW SPINDLE NOT MOVING
KIT - DIVERTER VALVE SERVICE
PUMP DOES NOT RUN
REGULATOR
PUMP DOES NOT RUN
KIT - SANITARY WATER SERVICE
OPEN CIRCUIT TO DHW MICROSWITCH
HARNESS NO16-31 24V
CH THERMISTOR
HARNESS NO16-31 24V
OBSERVATION PUMP RUNS
PCB - COMBINED - PACTROL
DHW THERMISTOR
HARNESS NO16-31 24V
FAN DOES NOT RUN
PCB - COMBINED - PACTROL
RESTRICTED - LOW FLOW RATE
PLATE HEAT EXCHANGER - ALFA LAVAL
DHW RUNS THEN SAFETY LED LIT - NOT SWITCHING
PRESSURE SWITCH - AIR
RESTRICTED - DHW RUNS HOT COLD
PLATE HEAT EXCHANGER - ALFA LAVAL
DHW RUNS HOT COLD - BURNER PRESSURE OK
PCB - COMBINED - PACTROL
DHW RUNS HOT COLD - MINIMUM WRONG
GAS VALVE ADJUSTMENT
DHW RUNS HOT COLD - MODUREG
HARNESS NO16-31 24V
DHW RUNS HOT COLD
GAS VALVE ADJUSTMENT
DHW RUNS HOT COLD
GAS VALVE - HONEYWELL
RESTRICTED
REGULATOR
DHW RUNS THEN SAFETY LED LIT - RUNNING SLOW
COMBI FAN ASSEMBLY
DHW FILTER RESTRICTED
KIT - SANITARY WATER SERVICE
OPEN CIRCUIT TO PCB
HARNESS NO 1 - 5 - MAINS INLET
BLOCKED - NO IGNITION
INJECTOR
STUCK IN - DHW TOO COOL RADIATORS HEAT
KIT - DIVERTER VALVE SERVICE
BLOCKED - DHW COOL
INJECTOR
RESTRICTED - DHW TOO COOL
PLATE HEAT EXCHANGER - ALFA LAVAL
DHW TOO HOT
PCB - COMBINED - PACTROL
EXCESSIVE PRESSURE RISE
FLEXIBLE HOSE
SHORTED - FUSE INVESTIGATION
HARNESS NO10-15 240V
SHORT CIRCUIT TO GAS VALVE - FUSE INVESTIGATION
HARNESS NO10-15 240V
SHORT CIRCUIT TO FAN - FUSE INVESTIGATION
HARNESS NO10-15 240V
NOT MODULATING ON DHW
PCB - COMBINED - PACTROL
DHW MODULATION
GAS VALVE ADJUSTMENT
BLOCKED DHW RUNS HOT COLD
PRESSURE GAUGE 4 BAR
DHW RUNS HOT / COLD
SYSTEM PRESSURE
BLOCKED DHW TOO COOL
PRESSURE GAUGE 4 BAR
DHW TOO COOL
SYSTEM PRESSURE
SHORT CIRCUIT TO DHW MICROSWITCH
HARNESS NO16-31 24V
STUCK OUT - FIRING WITH NO DEMAND
KIT - DIVERTER VALVE SERVICE
DHW DIAPHRAGM DAMAGED OR WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
SPINDLE OR CHAMBER HOUSING DAMAGED / WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
DHW DIAPHRAGM DAMAGED OR WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
SPINDLE OR CHAMBER HOUSING DAMAGED / WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
FAN RUNS BUT PUMP DOES NOT
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
PUMP RUNS BUT FAN DOES NOT
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
PUMP AND FAN RUN THEN SAFETY LED ILLUMINATES
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
PRESSURE DOES NOT INCREASE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
PRESSURE LOW BUT INCREASES WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL CH
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL CH
OVERHEAT TRIPS BEFORE 82°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
FLOW TEMPERATURE ABOVE 88°C AND BOILER DOES NOT SHUT DOWN
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
PRESSURE DOES NOT INCREASE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
PRESSURE LOW BUT INCREASES WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
MINIMUM PRESSURE CORRECT BUT MAXIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
MAXIMUM PRESSURE CORRECT BUT MINIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
NEITHER PUMP OR FAN RUN
CHARACTERISTIC TEST FROM OBSERVATION PUMP AND FAN RUNS
DHW DIAPHRAGM DAMAGED OR WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
SPINDLE OR CHAMBER HOUSING DAMAGED / WORN
CHARACTERISTIC TEST FROM INSPECTION DHW DIAPHRAGM
REGULATOR RESTRICTED OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DHW FILTER AND REGULATOR
FILTER / VENTURI RESTRICTED OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DHW FILTER AND REGULATOR
PUMP RUNS BUT FAN DOES NOT
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
DHW RUNS FOR A SHORT PERIOD THEN SAFETY LED ILLUMINATES
CHARACTERISTIC TEST FROM OPERATION DHW
REGULATOR RESTRICTED OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DHW FILTER AND REGULATOR
FILTER / VENTURI RESTRICTED OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION DHW FILTER AND REGULATOR
MINIMUM PRESSURE CORRECT BUT MAXIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
MAXIMUM PRESSURE CORRECT BUT MINIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
BURNER IGNITES BUT BAFFLES
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
BURNER IGNITES SMOOTHLY BUT DOES NOT ESTABLISH (SPARKING CONTINUES)
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION
PRESSURE PRESENT BUT BELOW APPROX 5MB
CHARACTERISTIC TEST FROM PRESSURE IGNITION
PRESSURE REMAINS AT 0MBAR
CHARACTERISTIC TEST FROM PRESSURE IGNITION
DHW TOO COOL, RADIATORS REMAIN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO COOL, RADIATORS BEGIN TO HEAT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW RUNS HOT / COLD
CHARACTERISTIC TEST FROM OPERATION DHW
BOILER UP TO TEMPERATURE RADIATORS COOL
CHARACTERISTIC TEST FROM OPERATION CH
BOILER AND RADIATOR TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CH
SYSTEM PRESSURE READS CORRECTLY BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
PRESSURE LOW BUT INCREASES WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
SYSTEM PRESSURE READS CORRECTLY BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
PRESSURE LOW BUT INCREASES WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SYSTEM
POWER ON LED DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
BOILER FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
20/09/2018 09:20:25 1809_1_50_1 24/10/2018 08:06:51
01/10/2018 15:11:03
INSPECTION DHW DIAPHRAGM
DHW SYSTEM ISOLATED AND DRAINED
VOLTAGE MAINS POWER IN AT PCB
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FUSE (MAINS FUSE)
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE AIR PRESSURE SWITCH AT PCB (NORMALLY CLOSED)
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
RESISTANCE AIR PRESSURE SWITCH AT APS (NORMALLY CLOSED)
DISCONNECT WIRE MARKED COM OR C FROM THE AIR PRESSURE SWITCH
RESISTANCE AIR PRESSURE SWITCH WITH KIT AT PCB
DISCONNECT CONNECTOR X6 FROM THE PCB
RESISTANCE HARNESS AIR PRESSURE SWITCH
DISCONNECT RIGHT HAND PLUG FROM THE PCB
RESISTANCE OVERHEAT
DISCONNECT 1 WIRE FROM THE OVERHEAT THERMOSTAT
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE MICROSWITCH PUMP PROVING
REMOVE THE PLASTIC COVER FROM THE PUMP PROVING
MICROSWITCH AND DISCONNECT WIRES
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
RESISTANCE GAS VALVE MAIN SOLENOID
DISCONNECT LEAD FROM GAS VALVE
RESISTANCE HARNESS EXTERNAL CONTROLS
DISCONNECT LEFT HAND PLUG (PINS 1-5) FROM THE PCB
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
OBSERVATION LINK OUT EXTERNAL CONTROLS
FIT A WIRE LINK BETWEEN THE TWO RIGHT HAND TERMINALS AT THE MAINS INLET TERMINAL BLOCK
RESISTANCE HARNESS EXTERNAL CONTROLS
DISCONNECT LEFT HAND PLUG (PINS 1-5) FROM THE PCB
OBSERVATION TYPE OF ELECTRODE
PLEASE SELECT WHICH TYPE OF IGNITION / DETECTION ELECTRODES ARE FITTED TO THE APPLIANCE.
RESISTANCE RECTIFICATION LEAD
DISCONNECT RECTIFICATION LEAD FROM THE PCB AND FROM THE RECTIFICATION ELECTRODE
RESISTANCE MAINS INTO BOILER AT TERMINAL BLOCK
DISCONNECT PLUG FOR PINS 1-5 FROM THE PCB
RESISTANCE CLOCK MOTOR
DISCONNECT RED WIRES FROM THE CLOCK
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
OBSERVATION TYPE OF ELECTRODE
PLEASE SELECT WHICH TYPE OF IGNITION / DETECTION ELECTRODES ARE FITTED TO THE APPLIANCE.
RESISTANCE IGNITION LEADS (3 TOTAL)
REMOVE ELECTRODE LEADS FROM SPARK GENERATOR
INSPECTION DHW SPINDLE
SET FLOW RATE TO 2.8 LITRES A MINUTE
INSPECTION DHW DIAPHRAGM
DHW SYSTEM ISOLATED AND DRAINED
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE HARNESS AIR PRESSURE SWITCH
DISCONNECT RIGHT HAND PLUG FROM THE PCB
TEMPERATURE DIFFERENTIAL CH
ATTACH A TEMPERATURE
RESISTANCE GAS VALVE MODUREG
DISCONNECT WHITE WIRES FROM GAS VALVE MODUREG
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
TEMPERATURE DIFFERENTIAL CH
ATTACH A TEMPERATURE
RESISTANCE MAINS INTO BOILER
REPLACE DAMAGED FUSE(S)
RESISTANCE PUMP
REMOVE PUMP COVER
REMOVE WIRES FROM PUMP CONNECTIONS
RESISTANCE FAN
DISCONNECT WIRES TO THE FAN
RESISTANCE GAS VALVE MAIN SOLENOID
DISCONNECT LEAD FROM GAS VALVE
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
VOLTAGE DC GAS VALVE MODULATION
ADJUST DHW FLOW RATE
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
OBSERVATION ISOLATE DHW
REMOVE LOWER PANEL FROM APPLIANCE
TURN DHW ISOLATION VALVE OFF
OBSERVATION ISOLATE DHW
REMOVE LOWER PANEL FROM APPLIANCE
TURN DHW ISOLATION VALVE OFF
INSPECTION DHW DIAPHRAGM
DHW SYSTEM ISOLATED AND DRAINED
RESISTANCE FUSE F1 (PCB)
GAIN ACCESS TO INSIDE OF PCB HOUSING (6X SCREWS)
REMOVE FUSE F1 FROM ITS HOLDER
INFORMATION FAULTY LED
TESTS CARRIED OUT HA
RESISTANCE FUSE F2 (PCB)
REMOVE FUSE F2 FROM ITS HOLDER
VOLTAGE PUMP AT PUMP
REMOVE PUMP COVER
VOLTAGE FAN AT FAN
GAIN ACCESS TO FAN
INSPECTION FAN VENTURI
REMOVE FAN ASSEMBLY
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
OVERHEAT FURTHER INVESTIGATION
ENSURE APPLIANCE IS
PRESSURE BURNER MAX AND MIN
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SET TO MAX
TEMPERATURE DIFFERENTIAL CH
ATTACH A TEMPERATURE
TEMPERATURE DIFFERENTIAL DHW
ATTACH A TEMPERATURE
TEMPERATURE DIFFERENTIAL DHW
ATTACH A TEMPERATURE
OBSERVATION RUN BOILER UP TO TEMPERATURE
ATTACH TEMPERATURE P
OBSERVATION PUMP OVERRUN
CH TEMPERATURE SET TO MAX
INSPECTION PUMP PROVING DIAPHRAGM
DRAIN BOILER PRIMARY CIRCUIT
UNCLIP PUMP PROVING SWITCH
RESISTANCE OVERHEAT AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
INSPECTION FAN VENTURI
REMOVE FAN ASSEMBLY
RESISTANCE SENSOR CH AND HARNESS
DISCONNECT RIGHT HAND PLUG FROM PCB
RESISTANCE MICROSWITCH PUMP PROVING AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
ADJUSTMENT PRESSURE MAX
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR SET TO MAX
RESISTANCE GAS VALVE MAIN SOLENOID AND HARNESS
DISCONNECT PLUG FOR PINS 10-15 FROM THE PCB
OBSERVATION LINK OUT EXTERNAL CONTROLS
FIT A WIRE LINK BETWEEN THE TWO RIGHT HAND TERMINALS AT THE MAINS INLET TERMINAL BLOCK
OBSERVATION LINK OUT INTEGRAL TIMER
REMOVE PCB FROM APPL
RESISTANCE HARNESS CLOCK
GAIN ACCESS TO CLOCK WIRING
DISCONNECT ORANGE WIRES FROM THE CLOCK
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
ADJUSTMENT PRESSURE MAX
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR SET TO MAX
ADJUSTMENT PRESSURE MIN
ATTACH U-GAUGE TO BU
INSPECTION RECTIFICATION ELECTRODE
GAIN ACCESS TO BURNER
RESISTANCE RECTIFICATION LEAD AND ELECTRODE
GAIN ACCESS TO AND D
INSPECTION INJECTOR
REMOVE BURNER ASSEMBLY
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
OBSERVATION LINK OUT INTEGRAL TIMER
REMOVE PCB FROM APPL
RESISTANCE HARNESS CLOCK
GAIN ACCESS TO CLOCK WIRING
DISCONNECT ORANGE WIRES FROM THE CLOCK
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE CLOCK MOTOR AND HARNESS
REMOVE PCB FROM APPLIANCE
DISCONNECT PLUG FOR PINS 6-9 FROM THE PCB
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
RESISTANCE IGNITION LEADS AND ELECTRODES (3 TOTAL)
REMOVE PCB FROM APPLIANCE
REMOVE ELECTRODE LEADS FROM SPARK GENERATOR ON THE PCB
RESISTANCE IGNITION LEADS AND ELECTRODE (2 TOTAL)
REMOVE PCB FROM APPLIANCE
REMOVE ELECTRODE LEADS FROM SPARK GENERATOR ON THE PCB
RESISTANCE MICROSWITCH DHW AND HARNESS
SET FLOW RATE TO 2.8 LITRES A MINUTE
DISCONNECT RIGHT HAND PLUG FROM THE PCB
RESISTANCE SENSOR CH AND HARNESS
DISCONNECT RIGHT HAND PLUG FROM PCB
RESISTANCE MICROSWITCH DHW
REMOVE THE PLASTIC C
INSPECTION DHW DIFFERENTIAL PIPES
DHW SYSTEM ISOLATED AND DRAINED
INSPECTION DHW FILTER AND REGULATOR
DHW SYSTEM ISOLATED AND DRAINED
RESISTANCE SENSOR DHW AND HARNESS
DISCONNECT RIGHT HAND PLUG FROM THE PCB
INSPECTION DHW FILTER AND REGULATOR
DHW SYSTEM ISOLATED AND DRAINED
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
RESISTANCE AIR PRESSURE SWITCH WITH KIT AT PCB
DISCONNECT CONNECTOR X6 FROM THE PCB
TEMPERATURE DIFFERENTIAL DHW
ATTACH A TEMPERATURE
PRESSURE BURNER MAX AND MIN
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SET TO MAX
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
ADJUSTMENT PRESSURE MIN
ATTACH U-GAUGE TO BU
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
ADJUSTMENT PRESSURE MAX
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR SET TO MAX
INSPECTION FAN VENTURI
REMOVE FAN ASSEMBLY
OBSERVATION SPARKING AT ELECTRODES
IF APPLIANCE HAS LEA
PRESSURE IGNITION
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
PRESSURE GAS INLET
ATTACH U-GAUGE TO INLET PRESSURE TEST POINT
PRESSURE IGNITION
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
TEMPERATURE DIFFERENTIAL DHW
ATTACH A TEMPERATURE
PRESSURE BURNER MAXIMUM
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
DHW TEMPERATURE SET TO MAX
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE SENSOR DHW
DISCONNECT PLUG FROM DHW SENSOR
RESISTANCE SENSOR CH
DISCONNECT PLUG FROM CH SENSOR
PRESSURE EXPANSION VESSEL
DISCHARGE PRIMARY SYSTEM WATER
TEMPERATURE INTEGRAL BYPASS
ENSURE RADIATORS ARE
RESISTANCE FAN AND HARNESS
DISCONNECT PLUG FOR PINS 10-15 FROM THE PCB
RESISTANCE GAS VALVE MAIN SOLENOID AND HARNESS
DISCONNECT PLUG FOR PINS 10-15 FROM THE PCB
RESISTANCE PUMP AND HARNESS
DISCONNECT PLUG FOR PINS 10-15 FROM THE PCB
ADJUSTMENT PRESSURES MAX AND MIN
ATTACH U-GAUGE TO BU
RESISTANCE MICROSWITCH DHW AND HARNESS (OPEN)
DISCONNECT RIGHT CONNECTOR FROM PCB (16-31)
OBSERVATION DISCONNECT EXTERNAL CONTROLS
DISCONNECT THE EXTER
RESISTANCE MICROSWITCH DHW (OPEN)
REMOVE THE PLASTIC COVER FROM THE HOT WATER
MICROSWITCH AND DISCONNECT WIRES
System Information
- Total Tests: 460
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control