Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect right connector from PCB (16-31)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With the pump running and the microswitch spindle fully extended measure the resistance between the violet wires (18 & 19) at the disconnected plug.
Resistance should be short circuit (zero resistance).