Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
WORCESTER 28 SI II - LPG
WARNING - IMPORTA
DHW FAN RUNS
DHW TEMPERATURE CONTROL SET TO MAXIMUM
DHW FLOW RATE
{ISOLATEMAINSPOWER}
WORCESTER 28 SI II - LPG
{ISOLATEMAINSPOWER}<
CH OPERATION
CH TEMPERATURE CONTROL SET TO MAXIMUM
DHW OPERATION
DHW TEMPERATURE CONTROL SET TO MAXIMUM
BURNER FULL RATE
{ISOLATEMAINSPOWER}<
DHW BURNER IGNITES
DHW TEMPERATURE CONTROL SET TO MAXIMUM
AUTO FROST
{ISOLATEMAINSPOWER}<
CH DEMAND
CH TEMPERATURE CONTROL SET TO MAXIMUM
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY CHECKS
SYSTEM CHECKS
SYSTEM CHECKS
BURNER ESTABLISHES
FLAME SENSE ELECTRODE
BURNER ESTABLISHES
FLAME SENSE ELECTRODE LEAD
SYSTEM PRESSURE RISE
EXPANSION VESSEL
DHW BURNER IGNITES (SPARKING)
GAS INLET PRESSURE
DHW BURNER IGNITES (SPARKING)
CONTROL PCB
DHW BURNER IGNITES (SPARKING) ELECTRICAL
GAS VALVE
DHW BURNER IGNITES (SPARKING)
ELECTRODE IGNITION
OVERRUNS
PRIMARY SENSOR
DHW BURNER IGNITES SPARKING PRESENT
OVERHEAT THERMOSTAT
AUTOFROST PROTECTION
PRIMARY SENSOR
DHW FLOW RATE
DHW INLET FILTER
DHW FLOW RATE
DHW FLOW REGULATOR
BURNER FULL RATE
GAS INLET PRESSURE
BURNER ESTABLISHES
GAS INLET PRESSURE
DHW FLOW RATE
DHW SERVICE VALVE
BURNER ESTABLISHES
HEAT EXCHANGER FLUE WAYS
BURNER ESTABLISHES
FLUE
BURNER ESTABLISHES
PRIMARY SENSOR
BURNER FULL RATE ELECTRICAL
GAS VALVE
BURNER FULL RATE
PRIMARY SENSOR
BURNER FULL RATE
DHW SENSOR
DHW OPERATION
PRIMARY SENSOR
DHW OPERATION
DHW SENSOR
DHW OPERATION
BURNER MANIFOLD
DHW OPERATION DHW TOO HOT
PRIMARY SENSOR
DHW OPERATION DHW TOO HOT
DHW SENSOR
DHW OPERATION DHW RUNS HOT THEN COLD
PRIMARY SENSOR
DHW OPERATION DHW RUNS HOT THEN COLD
OVERHEAT THERMOSTAT
DHW OPERATION DHW RUNS HOT THEN COLD
DHW SENSOR
CH OPERATION BOILER COOL RADIATORS COOL
PRIMARY SENSOR
CH OPERATION CH NOISY OPERATION
INTEGRAL BYPASS
CH OPERATION CH NOISY OPERATION
PRIMARY SENSOR
CH OPERATION CH NOISY OPERATION
CONTROL PCB
CH OPERATION CH NOISY OPERATION PUMP VOLTAGE
CONTROL PCB
CH DEMAND PROGRAMMER FITTED
CONTROL PCB
DHW FAN RUNS (FAN RUNS)
DHW SENSOR
FAN RUNS CH (FAN RUNS)
AIR PRESSURE SWITCH TUBES
DHW FAN RUNS (FAN RUNS)
VENTURI (AIR FLOW SENSOR)
DHW FAN RUNS (FAN RUNS)
OVERHEAT THERMOSTAT
DHW FAN RUNS (FAN RUNS FOR VERY SHORT TIME)
CONTROL PCB
DHW BURNER IGNITES (NO SPARKING)
AIR PRESSURE SWITCH TUBES
DHW BURNER IGNITES (NO SPARKING)
VENTURI (AIR FLOW SENSOR)
DHW BURNER IGNITES (NO SPARKING)
ELECTRODE IGNITION LEADS
DHW BURNER IGNITES (NO SPARKING)
ELECTRODE IGNITION
DHW FAN RUNS (FAN DOES NOT RUN)
FUSE F1
DHW FAN RUNS (FAN DOES NOT RUN)
FUSE F2
DHW FAN RUNS (FAN DOES NOT RUN)
TRANSFORMER
DHW FAN RUNS (FAN DOES NOT RUN)
AIR PRESSURE SWITCH TUBES
DHW FAN RUNS (FAN DOES NOT RUN)
VENTURI (AIR FLOW SENSOR)
DHW FAN RUNS (FAN DOES NOT RUN)
PRIMARY SENSOR
DHW FAN RUNS (FAN DOES NOT RUN)
CODE PLUG
DHW FAN RUNS (FAN DOES NOT RUN)
FLOW SWITCH
FAN
HARNESS
DHW OPERATION DHW NOISY OPERATION
HEAT EXCHANGER
DHW BURNER IGNITES (SPARKING) MECHANICAL
GAS VALVE
DHW BURNER IGNITES (SPARKING)
BURNER MANIFOLD
OVERRUNS
CONTROL PCB
AUTO FROST PROTECTION
CONTROL PCB
DHW FLOW RATE
HEAT EXCHANGER
BURNER ESTABLISHES
CONTROL PCB
BURNER FULL RATE
CONTROL PCB
BURNER FULL RATE MECHANICAL
GAS VALVE
DHW OPERATION DHW TOO COLD
HEAT EXCHANGER
DHW OPERATION DHW RUNS HOT THEN COLD
CONTROL PCB
DHW OPERATION DHW TOO HOT
CONTROL PCB
CH OPERATION BOILER COOL RADIATORS COOL
CONTROL PCB
CH OPERATION CH NOISY OPERATION
HEAT EXCHANGER
CH DEMAND PROGRAMMER FITTED
INTEGRAL PROGRAMMER
DHW FAN RUNS (FAN RUNS)
AIR PRESSURE SWITCH
DHW FAN RUNS (FAN RUNS)
CONTROL PCB
DHW FAN RUNS (FAN RUNS FOR VERY SHORT TIME)
FAN ASSEMBLY
DHW BURNER IGNITES (NO SPARKING)
AIR PRESSURE SWITCH
DHW BURNER IGNITES (NO SPARKING)
CONTROL PCB
DHW FAN RUNS 2
CONTROL PCB
DHW FAN RUNS (FAN DOES NOT RUN)
CONTROL PCB
DHW FAN RUNS (FAN DOES NOT RUN)
AIR PRESSURE SWITCH
DHW FAN RUNS
CONTROL PCB
FAN NEUTRAL
CONTROL PCB
DHW FAN RUNS (FAN DOES NOT RUN)
FAN ASSEMBLY
Sparking present
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
No sparking
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
DHW noisy operation
CHARACTERISTIC TEST FROM DHW OPERATION
DHW too cold
CHARACTERISTIC TEST FROM DHW OPERATION
DHW too hot
CHARACTERISTIC TEST FROM DHW OPERATION
CH noisy operation
CHARACTERISTIC TEST FROM CH OPERATION
Boiler to temperature, radiators cool
CHARACTERISTIC TEST FROM CH OPERATION
Boiler and radiators cool
CHARACTERISTIC TEST FROM CH OPERATION
Fan does not run
CHARACTERISTIC TEST FROM DHW FAN RUNS
DHW runs hot then cold
CHARACTERISTIC TEST FROM DHW OPERATION
Fan runs for approximately 2 seconds then stops
CHARACTERISTIC TEST FROM DHW FAN RUNS
Fan runs for approximately 35 seconds then stops
CHARACTERISTIC TEST FROM DHW FAN RUNS
MAINS VOLTAGE ABSENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE TO FAN HIGH SPEED
MAINS VOLTAGE PRESENT BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE TO FAN HIGH SPEED
07/01/2013 13:49:30 1303_2_30_1 10/01/2013 13:26:32
07/01/2013 14:19:50
DHW STOP COCK
{ISOLATEMAINSPOWER}
SET THE DHW STOP COCK TO FULLY OPEN
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
EXTERNAL CONTROLS VOLTAGE OUTPUT
{ISOLATEMAINSPOWER}
EXTERNAL CONTROLS VOLTAGE INPUT
{ISOLATEMAINSPOWER}
AIR PRESSURE SWITCH TUBES
{ISOLATEMAINSPOWER}
AIR PRESSURE SWITCH TUBES
{ISOLATEMAINSPOWER}
EXTERNAL CONTROLS VOLTAGE INPUT
{ISOLATEMAINSPOWER}
MAINS POWER SUPPLY
{ISOLATEMAINSPOWER}
AIR PRESSURE SWITCH TUBES
{ISOLATEMAINSPOWER}
FLAME SENSE ELECTRODE LEAD
{ISOLATEMAINSPOWER}<
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
OVERHEAT THERMOSTAT
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE OVERHEAT THERMOSTAT
BURNER PRESSURE
{ISOLATEMAINSPOWER}<
IGNITION ELECTRODE
{ISOLATEMAINSPOWER}
GAS VALVE VOLTAGE
{ISOLATEMAINSPOWER}<
GAS VALVE RESISTANCE
{ISOLATEMAINSPOWER}
REMOVE PLUG CONNECTOR ST16 FROM THE PCB
DHW INLET FILTER
{ISOLATEMAINSPOWER}<
DHW FLOW REGULATOR
{ISOLATEMAINSPOWER}
ENSURE APPLIANCE IS DRAINED AND DISCHARGED
GAS VALVE MODULATING SOLENOID VOLTAGE
{ISOLATEMAINSPOWER}<
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
GAS INLET PRESSURE
{ISOLATEMAINSPOWER}
ATTACH PRESSURE GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
HEAT EXCHANGER (FLUE WAYS)
{ISOLATEMAINSPOWER}
GAS VALVE MODULATING SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
REMOVE PLUG CONNECTOR ST16 FROM THE PCB
DHW SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE DHW SENSOR
VOLTAGE TO FAN (HIGH SPEED)
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB, USE ISOLATION MAT AS REQUIRED.
DHW SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE DHW SENSOR
BURNER MANIFOLD
{ISOLATEMAINSPOWER}
DHW SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE DHW SENSOR
OVERHEAT THERMOSTAT
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE OVERHEAT THERMOSTAT
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
DHW SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE DHW SENSOR
INTEGRAL PROGRAMMER
{ISOLATEMAINSPOWER}<
PUMP VOLTAGE
{ISOLATEMAINSPOWER}<
PUMP VOLTAGE
{ISOLATEMAINSPOWER}<
INTEGRAL BYPASS
{ISOLATEMAINSPOWER}
TURN OFF DHW STOP COCK
DRAIN AND DISCHARGE APPLIANCE
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
CH MODULATION
{ISOLATEMAINSPOWER}<
VOLTAGE TO FAN (LOW SPEED)
{ISOLATEMAINSPOWER}
GAIN ACCESS TO PCB, USE ISOLATION MAT AS REQUIRED.
DHW SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE DHW SENSOR
AIR PRESSURE SWITCH PROVING
{ISOLATEMAINSPOWER}<
OVERHEAT THERMOSTAT
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE OVERHEAT THERMOSTAT
VENTURI
{ISOLATEMAINSPOWER}
AIR PRESSURE SWITCH PROVING
{ISOLATEMAINSPOWER}<
IGNITION ELECTRODE LEADS
{ISOLATEMAINSPOWER}
REMOVE THE IGNITION ELECTRODE LEADS
VENTURI
{ISOLATEMAINSPOWER}
IGNITION ELECTRODE
{ISOLATEMAINSPOWER}
AIR PRESSURE SWITCH N/O
{ISOLATEMAINSPOWER}
REMOVE THE BLUE WIRE FROM THE AIR PRESSURE SWITCH
FUSE F2
{ISOLATEMAINSPOWER}
REMOVE FUSE F2 FROM THE PCB
FUSE F1
{ISOLATEMAINSPOWER}
REMOVE FUSE F1 FROM THE PCB
TRANSFORMER RESISTANCE
{ISOLATEMAINSPOWER}
REMOVE THE TRANSFORMER FROM THE CONTROL BOX
PRIMARY SENSOR
{ISOLATEMAINSPOWER}
REMOVE ONE OF THE WIRES FROM THE PRIMARY SENSOR
VENTURI
{ISOLATEMAINSPOWER}
CODE PLUG
{ISOLATEMAINSPOWER}
MAIN ON/OFF CONTROL SET TO OFF POSITION
FLOW SWITCH
{ISOLATEMAINSPOWER}
CONTINUITY FAN HARNESS
{ISOLATEMAINSPOWER}
DISCONNECT CONNECTOR ST1 FROM THE PCB.
System Information
- Total Tests: 190
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control