Set Appliance State:
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Enter the appliances parameter setting mode, click here for a guide on how to do this.
Check parameter P04, this is the % of maximum output at ignition, this can change if the appliance experiences electrical supply fluctuations and can also be set incorrectly on a brand new PCB causing poor ignition.
On this appliance the parameter P04 should be set to "40", if set to a different value it should be changed to "40"
Once the parameter has been set correctly run the appliance again to see if the ignition is now smooth.
Check parameter P04, this is the % of maximum output at ignition, this can change if the appliance experiences electrical supply fluctuations and can also be set incorrectly on a brand new PCB causing poor ignition.
On this appliance the parameter P04 should be set to "40", if set to a different value it should be changed to "40"
Once the parameter has been set correctly run the appliance again to see if the ignition is now smooth.