Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
4707723 BAXI 424 COMBI
WARNING - IMPORTA
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT
OBSERVATION CH DEMAND RECOGNISED
ENSURE EXTERNAL CONTROLS ARE CALLING FOR HEAT
OBSERVATION DHW DEMAND RECOGNISED
TURN HOT WATER TAP ON WITH A FLOW RATE OF 3 L/MIN
HEADER FOR FUSE INVESTIGATION
OK TO BE BLANK
HEADER FOR JUMPER FAULT CODES E02 19, 20,21
OK TO BE BLANK
HEADER FOR FLUE SENSOR ERROR CODES
OK TO BE BLANK
HEADER FOR RETURN SENSOR ERROR CODES
OK TO BE BLANK
HEADER FOR FLOW SENSOR ERROR CODES
OK TO BE BLANK
HEADER FOR ERROR CODE E02 00 BOILER RESET IN PROGRESS
OK TO BE BLANK
HEADER FOR ERROR CODE E01 20 MAX FLUE GAS TEMP REACHED
OK TO BE BLANK
HEADER FOR ERROR CODE E04 12 FALSE FLAME SIGNAL
OK TO BE BLANK
HEADER FOR ERROR CODE H03 01 COMM ERROR
OK TO BE BLANK
HEADER FOR ERROR CODE E01 11 INCORRECT FAN SPEED
OK TO BE BLANK
ERROR CODES H01 05, H01 08, H01 14, H01 18, H01 21
OK TO BE BLANK
ERROR CODES E02 47, E02 48
OK TO BE BLANK
HEADER FOR ERROR CODE E01 02
OK TO BE BLANK
HEADER FOR RESET E ERROR CODES
OK TO BE BLANK
HOW TO SET APPLIANCE TO MAX RATE
NOTE.
THE
OBSERVATION APPLIANCE INITIALISATION
ENSURE NO DEMANDS ARE PRESENT
HEADER FOR H01 00 ERROR CODE
OK TO BE BLANK
POOR FLOW RATE
PACK - TAP
POOR FLOW RATE
MAINS WATER SUPPLY
POOR FLOW RATE
DHW CARTRIDGE
TOO LOW
GAS INLET PRESSURE
DHW RUNS HOT THEN COLD
SYSTEM PRESSURE
DHW RUNS HOT THEN COLD
SENSOR (FLOW)
DHW RUNS HOT THEN COLD
SENSOR (RETURN)
PERMANENT FAULT CODES
ERROR CODES
PUMP DOES NOT RUN
COMBUSTION CONTROL UNIT
TEMPORARY FAULT CODES
ERROR CODES
PUMP DOES NOT RUN
HARNESS - WIRING - PUMP
DHW TOO HOT
SENSOR (FLOW)
RADS HEATING WITH NO DEMAND
COMBUSTION CONTROL UNIT
RADS HEATING WITH NO DEMAND
WIRING - 3 WAY VALVE MOTOR
POOR HW RADS REMAIN COOL
SYSTEM PRESSURE
POOR HW RADS REMAIN COOL
SENSOR (FLOW)
DHW TOO HOT
SENSOR (RETURN)
BOILER UP TO TEMP RADS COOL
FLOW AND RETURN ISOLATION VALVES
BOILER AND SYSTEM TEMP LOW
SENSOR (FLOW)
BOILER AND SYSTEM TEMP LOW
SENSOR (RETURN)
BURNER IGNITION
GAS INLET PRESSURE
IGNITES BUT DOES NOT ESTABLISH
LEAD IGNITION ELECTRODE
CASE OFF
ERROR CODES
BOILER NOISY
COMBUSTION SEALS
BOILER NOISY/BAFFLES
SILENCER
BOILER NOISY
BURNER ASSEMBLY
BOILER NOISY
CONDENSATE TRAP AND SYPHON
FUSE INVESTIGATION
DIVERTER VALVE COMPONENTS
FUSE INVESTIGATION
3 WAY VALVE MOTOR HEAD
FUSE INVESTIGATION
COMBUSTION CONTROL UNIT
FUSE INVESTIGATION 2
COMBUSTION CONTROL UNIT
BOILER RESET IN OPERATION
NORMAL OPERATION
ERROR CODE H03 01 COM ERROR
COMBUSTION CONTROL UNIT
ERROR CODE H0301 COM ERROR
WIRING - LOW VOLTAGE
OUT OF CALIBRATION
SENSOR (FLOW)
TEMP FAULT CODES
WIRING - SENSORS
LOW
SYSTEM PRESSURE
INCORRECTLY FITTED
SENSOR FITMENT
PARTIALLY/FULLY CLOSED
FLOW AND RETURN ISOLATION VALVES
WEAK
PUMP
NO VOLTAGE TO PUMP
COMBUSTION CONTROL UNIT
TEMP FAULT CODES
HARNESS - WIRING - PUMP
BLOCKED / RESTRICTED
FILTER - CH
RESTRICTED
HEAT EXCHANGER ASSEMBLY
BOILER AND SYSTEM TEMP LOW CH
JUMPER POSITIONS
INCORRECT PUMP OVERRUN
COMBUSTION CONTROL UNIT
PUMP OVERRUN
COMBUSTION CONTROL UNIT
SPARKING NO IGNITION
IGNITION ELECTRODE ASSEMBLY
INCORRECT SPARK GAP TO BURNER
IGNITION ELECTRODE ASSEMBLY (GAP TO BURNER)
INCORRECT FAN PRESSURE
CONDENSATE TRAP AND SYPHON
INCORRECT FAN PRESSURE
BURNER ASSEMBLY
INCORRECT FAN PRESSURE
HEAT EXCHANGER FLUEWAYS
IGNITES BUT DOES NOT ESTABLISH
GAS INLET PRESSURE
IGNITES BUT DOES NOT ESTABLISH
CONDENSATE TRAP AND SYPHON
IGNITES BUT DOES NOT ESTABLISH
SILENCER
IGNITES BUT DOES NOT ESTABLISH
IGNITION ELECTRODE ASSEMBLY
INITIAL SETUP PAGE INFO
ERROR CODES
NO VOLTAGE TO HALL SENSOR
COMBUSTION CONTROL UNIT
FAN DOES NOT RUN
WIRING - SENSORS
TURBINE NOT SPINNING FREELY
DHW CARTRIDGE
ACTIVATING CHIMNEY SWEEP FUNCTION
ERROR CODES
SPARKING PRESENT BUT DOES NOT IGNITE
LEAD IGNITION ELECTRODE
BURNER DOES NOT IGNITE
COMBUSTION CONTROL UNIT
FLAT
EXPANSION VESSEL
FAILED COMBUSTION TEST
CONDENSATE TRAP AND SYPHON
FAILED COMBUSTION TEST
COMBUSTION SEALS
FAILED COMBUSTION TEST
SILENCER
FAILED COMBUSTION TEST
BURNER ASSEMBLY
FAILED COMBUSTION TEST 2
COMBUSTION CONTROL UNIT
UNABLE TO ADJUST GAS VALVE 2
COMBUSTION CONTROL UNIT
COMBUSTION PERFORMANCE ANALYSIS
COMBUSTION VALUE ADJUSTMENT
FAILED COMBUSTION TEST
HEAT EXCHANGER FLUEWAYS
FAN DOES NOT RUN
COMBUSTION CONTROL UNIT
BOILER NOISY
GAS INLET PRESSURE
FAILED GAS RATE POOR HW
CONDENSATE TRAP AND SYPHON
FAILED GAS RATE POOR HW
SILENCER
FAILED GAS RATE POOR HW
BURNER ASSEMBLY
FAILED GAS RATE POOR HW
HEAT EXCHANGER FLUEWAYS
POOR HW RADS COOL
EXTERNAL MIXING
POOR HW RADS REMAIN COOL
SENSOR (RETURN)
ERROR CODES E02 47 48
EXTERNAL DEVICE
FUSE INVESTIGATION 2
PUMP
FUSE INVESTIGATION
PUMP
BOILER NOISY
HEAT EXCHANGER FLUEWAYS
E CODES NOT RESETTING
COMBUSTION CONTROL UNIT
BOILER UP TO TEMP RADS COLD
CARTRIDGE - BYPASS
BOILER UP TO TEMP RADS COLD
FILTER - CH
BOILER UP TO TEMP RADS COLD
COMBUSTION CONTROL UNIT
BOILER UP TO TEMP RADS COLD
WIRING - 3 WAY VALVE MOTOR
OUT OF CALIBRATION 1
SENSOR (FLOW)
TEMP FAULT CODES 3
WIRING - SENSORS
BLOCKED
HYDRAULIC BLOCK - RIGHT SECTION
SETTING APPLIANCE TO MAX RATE
ERROR CODES
BOILER NOISY
FLUE
FLUE SENSOR ERROR CODE
COMBUSTION CONTROL UNIT
RETURN SENSOR ERROR CODES
COMBUSTION CONTROL UNIT
FLOW SENSOR ERROR CODES
COMBUSTION CONTROL UNIT
ERROR CODE E01 20
WIRING - SENSORS
ERROR CODE E01 20
SENSOR (FLOW)
E01 20
WIRING - SENSORS
ERROR CODE E01 20
SYSTEM PRESSURE
ERROR CODE E01 20
HYDRAULIC BLOCK - RIGHT SECTION
ERROR CODE E01 20 NO VOLTAGE TO PUMP
COMBUSTION CONTROL UNIT
ERROR CODE E01 20
HARNESS - WIRING - PUMP
ERROR CODE E01 20
CONDENSATE TRAP AND SYPHON
ERROR CODE E01 20
SILENCER
ERROR CODE E01 20
BURNER ASSEMBLY
ERROR CODE E01 20
SENSOR FITMENT
FAULT CODE E01 20
WIRING - SENSORS
ERROR CODE E04 12
POLARITY
ERROR CODE E04 12 GAS VALVE PASSING
COMBUSTION CONTROL UNIT
LOW PRESSURE ERROR CODES
HYDRAULIC BLOCK - RIGHT SECTION
LOW PRESSURE FAULT CODES
SYSTEM PRESSURE
LOW PRESSURE
COMBUSTION CONTROL UNIT
FLUE SENSOR ERROR CODES
WIRING - SENSORS
RETURN SENSOR ERROR CODES
WIRING - SENSORS
FLOW SENSOR ERROR CODES
SENSOR (FLOW)
ERROR E04 12 FALSE FLAME SIGNAL
IGNITION ELECTRODE ASSEMBLY
ERROR CODE E04 08
SYSTEM PRESSURE
ERROR CODE E04 08
HYDRAULIC BLOCK - RIGHT SECTION
ERROR CODE E04 08
FLOW AND RETURN ISOLATION VALVES
ERROR CODE E0 408
SENSOR (FLOW)
FAULT CODE E04 08
WIRING - SENSORS
E04 08
COMBUSTION CONTROL UNIT
ERROR CODE E04 08
HARNESS - WIRING - PUMP
ERROR CODE E04 08
PUMP
FAILED PUMP OVERRUN
COMBUSTION CONTROL UNIT
ERROR CODE E08 04
HEAT EXCHANGER ASSEMBLY
ERROR CODE E08 04
FILTER - CH
ERROR CODE E04 08
LIMIT THERMOSTAT
ERROR CODE E01 02
SYSTEM PRESSURE
ERROR CODE E01 02
HYDRAULIC BLOCK - RIGHT SECTION
ERROR CODE E01 02
SENSOR FITMENT
ERROR CODE E01 02
PIPEWORK CONFIGURATION
ERROR CODE E01 02
FLOW AND RETURN ISOLATION VALVES
E01 02
COMBUSTION CONTROL UNIT
ERROR CODE E01 02
HARNESS - WIRING - PUMP
E01 02
PUMP
ERROR CODE E01 02
COMBUSTION CONTROL UNIT
ERROR CODE E01 02
HEAT EXCHANGER ASSEMBLY
ERROR CODE E01 02
FILTER - CH
ERROR CODE E01 02
SENSOR (FLOW)
E01 02
WIRING - SENSORS
ERROR CODE E01 11
CONDENSATE TRAP AND SYPHON
ERROR CODE E01 11
SILENCER
ERROR CODE E01 11
BURNER ASSEMBLY
ERROR CODE E0 11
HEAT EXCHANGER FLUEWAYS
ERROR CODE E01 11
FLUE
FAULT CODES E02 19 20 21
JUMPER POSITIONS
CH DOES NOT RESPOND 2
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND 2
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 6
WIRING - LOW VOLTAGE
CH DOES NOT RESPOND 6
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND 8
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 8
WIRING - LOW VOLTAGE
NO CH
WIRING - LOW VOLTAGE
NO CH 1
WIRING - LOW VOLTAGE
CH DOES NOT RESPOND 5
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND 5
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 7
WIRING - LOW VOLTAGE
CH DOES NOT RESPOND 3
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND 3
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 5
WIRING - LOW VOLTAGE
CH DOES NOT RESPOND 4
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND 4
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 4
WIRING - LOW VOLTAGE
CH DOES NOT RESPOND
CONNECTOR - TIMER BRIDGE
CH DOES NOT RESPOND
CABLE - POWER SUPPLY - PCB/TIMER
CH DOES NOT RESPOND 3
WIRING - LOW VOLTAGE
PUMP RUNS CONTINUOUS
SENSOR (FLOW)
PUMP RUNS CONTINUOUS
SENSOR (RETURN)
ERROR CODES
ERROR CODES
BOILER FIRES WITH NO DEMAND
SENSOR (FLOW)
BOILER FIRES WITH NO DEMAND
SENSOR (RETURN)
ON WITH NO DEMAND 2
CONNECTION BOARD - WIRING
ON WITH NO DEMAND
CONNECTION BOARD - WIRING
BOILER FIRES WITH NO DEMAND
PLUMBING ISSUE
NO CH 3
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 7
WIRING - LOW VOLTAGE
NO CH 2
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 6
WIRING - LOW VOLTAGE
NO CH
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 2
WIRING - LOW VOLTAGE
NO CH 1
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 3
WIRING - LOW VOLTAGE
NO CH 5
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 5
WIRING - LOW VOLTAGE
NO CH 4
CABLE - POWER SUPPLY - PCB/TIMER
NO CH 4
WIRING - LOW VOLTAGE
BLOWN POWER UP SELF TEST
FUSE (MAINS)
BLANK DISPLAY
CONNECTION BOARD - WIRING
BLOWN POWER UP SELF TEST
FUSE F1
BLANK DISPLAY
WIRING - LOW VOLTAGE
PUMP RUNS CONTINUOUS NO DISPLAY
SENSOR (FLOW)
PUMP RUNS CONTINUOUS NO DISPLAY
SENSOR (RETURN)
BOILER FIRES WITH NO DEMAND NO DISPLAY
SENSOR (FLOW)
BOILER FIRES WITH NO DEMAND NO DISPLAY
SENSOR (RETURN)
BOILER FIRES WITH NO DEMAND NO DISPLAY
PLUMBING ISSUE
ON WITH NO DEMAND BLANK DISPLAY
CONNECTION BOARD - WIRING
ON WITH NO DEMAND NO DISPLAY
CONNECTION BOARD - WIRING
PUMP DOES NOT RUN NO DISPLAY
COMBUSTION CONTROL UNIT
PUMP DOES NOT RUN NO DISPLAY
HARNESS - WIRING - PUMP
POOR FLOW RATE NO DISPLAY
PACK - TAP
POOR FLOW RATE NO DISPLAY
MAINS WATER SUPPLY
POOR FLOW RATE NO DISPLAY
DHW CARTRIDGE
NO VOLTAGE TO HALL SENSOR NO DISPLAY
COMBUSTION CONTROL UNIT
FAN DOES NOT RUN NO DISPLAY
WIRING - SENSORS
TURBINE NOT SPINNING FREELY NO DISPLAY
DHW CARTRIDGE
BLANK DISPLAY
PCB - HMI CONTROL
ERROR CODE H01 00
COMBUSTION CONTROL UNIT - COMM ERROR
DIAGNOSTIC PROCEDURE
ERROR CODES
POOR FLOW RATE
DHW PLATE HEAT EXCHANGER ASSEMBLY
DHW RUNS HOT THEN COLD
COMBUSTION CONTROL UNIT
DHW RUNS HOT THEN COLD
DHW PLATE HEAT EXCHANGER ASSEMBLY
DOES NOT RUN
PUMP
RADS HEATING WITH NO DEMAND
3 WAY VALVE MOTOR HEAD
DHW TOO HOT
COMBUSTION CONTROL UNIT
BOILER AND SYSTEM TEMP LOW
COMBUSTION CONTROL UNIT
FUSE INVESTIGATION
WIRING - 3 WAY VALVE MOTOR
FUSE INVESTIGATION
FUSE FURTHER INVESTIGATION
ERROR CODE E02 00
PCB - HMI CONTROL (RESET BUTTON)
ERROR CODE H03 01 COM ERROR
PCB - HMI CONTROL
UNABLE TO RESET / SENSORS OK
COMBUSTION CONTROL UNIT
TEMP FAULT CODES 1
WIRING - SENSORS
OUT OF CALIBRATION
SENSOR (RETURN)
DHW RUNS HOT THEN COLD
HEAT EXCHANGER ASSEMBLY
TEMP FAULT CODES
PUMP
TEMP FAULT CODES
COMBUSTION CONTROL UNIT
RESTRICTED
DHW PLATE HEAT EXCHANGER ASSEMBLY
GAS VALVE NOT OPENING
COMBUSTION CONTROL UNIT
NO IGNITION
COMBUSTION CONTROL UNIT
FAN RESTRICTED
COMBUSTION CONTROL UNIT
FAN VENTURI RESTRICTED/BLOCKED
COMBUSTION CONTROL UNIT
DOES NOT RECOGNISE CH DEMAND
COMBUSTION CONTROL UNIT
NO VOLTAGE AT MAIN PCB CH
COMBUSTION CONTROL UNIT
DOES NOT RESPOND TO CH DEMAND 2
COMBUSTION CONTROL UNIT
DOES NOT RESPOND TO CH DEMAND 3
COMBUSTION CONTROL UNIT
NOT RECOGNISING DEMAND
COMBUSTION CONTROL UNIT
FAN DOES NOT RUN
HALL SENSOR ASSEMBLY
BLOCKED
PIPE ASSEMBLY - EXPANSION VESSEL
FAILED COMBUSTION TEST
ERROR CODES
IGNITES BUT DOES NOT ESTABLISH
COMBUSTION CONTROL UNIT
IGNITES BUT DOES NOT ESTABLISH
BURNER ASSEMBLY
NOT ESTABLISHING
IGNITION ELECTRODE ASSEMBLY (GAP TO BURNER)
POOR HW RADS REMAIN COOL
DHW PLATE HEAT EXCHANGER ASSEMBLY
POOR HW RADS REMAIN COLD
HEAT EXCHANGER ASSEMBLY
DOES NOT RESPOND TO CH DEMAND
COMBUSTION CONTROL UNIT
DOES NOT RESPOND TO CH DEMAND 1
COMBUSTION CONTROL UNIT
FAILED GAS RATE POOR HW
COMBUSTION CONTROL UNIT
POOR HOT WATER RADS COOL
COMBUSTION CONTROL UNIT
FUSE INVESTIGATION
PWM PUMP WIRING
FUSE INVESTIGATION
HARNESS - WIRING - PUMP
BOILER NOISY/BAFFLES
COMBUSTION CONTROL UNIT
RETEST APPLIANCE ERROR CODE RESET
ERROR CODE RESET
BOILER UP TO TEMP RADS COLD
3 WAY VALVE MOTOR HEAD
RADS HEATING WITH NO DEMAND
CARTRIDGE 3 WAY VALVE
TEMP FAULT CODES 2
WIRING - SENSORS
OUT OF CALIBRATION 1
SENSOR (RETURN)
BLOCKED
PRESSURE GAUGE
FLUE SENSOR ERROR CODES
ERROR CODE RESET
RETURN SENSOR ERROR CODES
ERROR CODE RESET
FLOW SENSOR ERROR CODES
ERROR CODE RESET
E01 20
COMBUSTION CONTROL UNIT
ERROR CODE E01 20
NTC SENSOR (FLUE)
ERROR E01 20
WIRING - SENSORS
ERROR CODE E01 20
SENSOR (RETURN)
ERROR CODE E01 20
PRESSURE GAUGE
ERROR CODE E01 20
PUMP
ERROR CODE E01 20
COMBUSTION CONTROL UNIT
ERROR CODE E01 20
HEAT EXCHANGER FLUEWAYS
E01 20
NTC SENSOR (FLUE)
LOW PRESSURE FAULT CODES
PRESSURE GAUGE
LOW PRESSURE FAULT CODES
ERROR CODE RESET
LOW PRESSURE FAULT CODES
WIRING - SENSORS
LOW PRESSURE FAULT CODES
PRESSURE SWITCH
LOW PRESSURE FAULT CODES
HYDRAULIC BLOCK - LEFT SECTION
LOW WATER PRESSURE FAULT CODES 1
PRESSURE SWITCH
LOW WATER FAULT CODES
CARTRIDGE - BYPASS
FLUE SENSOR ERROR CODES
NTC SENSOR (FLUE)
RETURN SENSOR ERROR CODES
SENSOR (RETURN)
FLOW SENSOR ERROR CODES
WIRING - SENSORS
ERROR CODE E04 12 FALSE FLAME SIGNAL
COMBUSTION CONTROL UNIT
ERROR CODE E04 08
PRESSURE GAUGE
E04 08
WIRING - SENSORS
ERROR CODE E04 08
SENSOR (RETURN)
E04 08
PUMP
ERROR CODE E08 04
DHW PLATE HEAT EXCHANGER ASSEMBLY
NORMAL OPERATION
OVERHEAT
ERROR CODE E04 08 CONTINUES TO HEAT
COMBUSTION CONTROL UNIT
ERROR CODE E08 04 OVERHEATS EARLY
LIMIT THERMOSTAT
ERROR CODE E04 08
COMBUSTION CONTROL UNIT
ERROR CODE E04 08
WIRING - SENSORS
ERROR CODE E01 02
PRESSURE GAUGE
ERROR CODE E01 02
PUMP
ERROR CODE E01 02
DHW PLATE HEAT EXCHANGER ASSEMBLY
ERROR E01 02
COMBUSTION CONTROL UNIT
ERROR CODE E01 02
WIRING - SENSORS
FAULT CODE E01 02
COMBUSTION CONTROL UNIT
ERROR CODE E01 02
SENSOR (RETURN)
ERROR CODE E01 11
COMBUSTION CONTROL UNIT
FAULT CODES E02 19 20 21
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 10
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 12
CONNECTION BOARD - WIRING
NO CH 4
CONNECTION BOARD - WIRING
NO CH 5
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 13
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 5
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 11
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 3
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 1
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 4
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 8
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 2
CONNECTION BOARD - WIRING
PUMP RUNS CONTINOUSLY
FROST PROTECTION
PUMP RUNS CONTINUOUS
COMBUSTION CONTROL UNIT
ERROR CODES
ERROR CODES
NORMAL OPERATION
FROST PROTECTION
BOILER FIRES WITH NO DEMAND
INTERNAL PROGRAMMER / TIMER
FIRING WITH NO DEMAND
COMBUSTION CONTROL UNIT
CH DOES NOT RESPOND 4
INTERNAL PROGRAMMER / TIMER
NO CH 8
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 3
INTERNAL PROGRAMMER / TIMER
NO CH 7
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 5
INTERNAL PROGRAMMER / TIMER
NO CH 2
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 6
INTERNAL PROGRAMMER / TIMER
NO CH 3
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND 1
INTERNAL PROGRAMMER / TIMER
NO CH
CONNECTION BOARD - WIRING
CH DOES NOT RESPOND
INTERNAL PROGRAMMER / TIMER
NO CH 6
CONNECTION BOARD - WIRING
FURTHER INVESTIGATION MAINS
ERROR CODES
BLANK DISPLAY
CABLE - POWER SUPPLY - PCB/TIMER
NO POWER TO DISPLAY PCB
COMBUSTION CONTROL UNIT
FURTHER INVESTIGATION FUSE F1
ERROR CODES
FAN DOES NOT RUN NO DISPLAY
COMBUSTION CONTROL UNIT
PUMP RUNS CONTINOUSLY NO DISPLAY
FROST PROTECTION
PUMP RUNS CONTINUOUS NO DISPLAY
COMBUSTION CONTROL UNIT
NORMAL OPERATION NO DISPLAY
FROST PROTECTION
BOILER FIRES WITH NO DEMAND NO DISPLAY
INTERNAL PROGRAMMER / TIMER
BLANK DISPLAY FURTHER INVESTIGATION
PCB - HMI CONTROL - FURTHER INVESTIGATION
POOR FLOW RATE NO DISPLAY
DHW PLATE HEAT EXCHANGER ASSEMBLY
NOT RECOGNISING DEMAND BLANK DISPLAY
COMBUSTION CONTROL UNIT
FAN DOES NOT RUN NO DISPLAY
HALL SENSOR ASSEMBLY
DHW RUNS HOT THEN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
TEMPERATURE RISE UNSATISFACTORY, RADIATORS REMAINS COOL
CHARACTERISTIC TEST FROM OPERATION DHW
TEMPERATURE RISE UNSATISFACTORY, RADIATORS HEAT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
APPLIANCE DOES NOT RESPOND TO A CH DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
PUMP SPEED CONTROL RESISTANCES NOT AS ABOVE
CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS - FUSE INVESTIGATION
PUMP MAINS SUPPLY RESISTANCES NOT AS ABOVE
CHARACTERISTIC TEST FROM RESISTANCE PUMP AND HARNESS - FUSE INVESTIGATION
FAN PRESSURE DOES NOT REACH 2.5 - 3MB OR PRESSURE IS NEGATIVE
CHARACTERISTIC TEST FROM PRESSURE FAN DURING IGNITION PHASE
FAN PRESSURE EXCEEDS 2.5 - 3MB (E G 4MB)
CHARACTERISTIC TEST FROM PRESSURE FAN DURING IGNITION PHASE
FAN PRESSURE REACHES 2.5 - 3MB BUT DOES NOT CHANGE TO 0MB
CHARACTERISTIC TEST FROM PRESSURE FAN DURING IGNITION PHASE
3VDC PRESENT ON TEST 1 BUT DOES NOT DROP TO 0 VDC
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
VOLTAGE ABSENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT BAFFLES OUT AND/OR NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
3VDC PRESENT ON TEST 1 BUT DOES NOT DROP TO 0VDC
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
VOLTAGE ABSENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
BURNER RESTRICTED / BLOCKED AND/OR IN POOR CONDITION
CHARACTERISTIC TEST FROM INSPECTION BURNER AND SPARK GAP TO BURNER
SPARK GAP TO BURNER INCORRECT
CHARACTERISTIC TEST FROM INSPECTION BURNER AND SPARK GAP TO BURNER
APPLIANCE DOES NOT RESPOND TO A CH DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
3VDC PRESENT ON TEST 1 BUT DOES NOT DROP TO 0VDC
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
VOLTAGE ABSENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE CH DEMAND AT MAIN PCB
HYDRAULIC MANIFOLD BLOCKED
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SWITCH AND HYDRAULIC MANIFOLD
PRESSURE SWITCH BLOCKED
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SWITCH AND HYDRAULIC MANIFOLD
BYPASS BLOCKED
CHARACTERISTIC TEST FROM INSPECTION PRESSURE SWITCH AND HYDRAULIC MANIFOLD
APPLIANCE CONTINUES TO HEAT BEYOND 85°C
CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMPERATURE
APPLIANCE OVERHEATS BEFORE 85°C IS REACHED
CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMPERATURE
DISPLAY BLANK
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
APPLIANCE FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
ERROR CODE DISPLAYED
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
PUMP RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION - NO DISPLAY
APPLIANCE FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
PUMP RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM OBSERVATION BOILER INITIALISATION
BOILER AND SYSTEM TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
BOILER UP TO TEMPERATURE, RADIATORS DO NOT HEAT SUFFICIENTLY
CHARACTERISTIC TEST FROM OPERATION CH
SYSTEM PRESSURE RISE IS EXCESSIVE
CHARACTERISTIC TEST FROM OPERATION CH
24/10/2017 10:32:22 1710_1_50_1 10/11/2017 11:33:36
30/10/2017 09:57:56
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
VOLTAGE DEMAND FROM HALL SENSOR
{GAINPCBACS}
ENSURE NO DEMANDS
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE TO DIVERTER VALVE (DHW DEMAND)
{GAINPCBACS}
INSPECTION DIVERTER VALVE - FUSE INVESTIGATION
REMOVE ELECTRICAL CO
RESISTANCE DIVERTER VALVE MOTOR - FUSE INVESTIGATION
REMOVE ELECTRICAL CONNECTOR FROM THE DIVERTER MOTOR
VOLTAGE TO DISPLAY PCB
{GAINPCBACS}
OBSERVATION RESET APPLIANCE - ENSURE APPLIANCE IS COOL
ENSURE APPLIANCE IS COOL
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
VOLTAGE PUMP AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION HEATING FILTER
BOILER DRAINED AND DISCHARGED
VOLTAGE CH DEMAND AT MAIN PCB
{GAINPCBACS}
ENSURE NO DEMANDS
BYPASS EXTERNAL CONTROLS - 24V
DISCONNECT 24V EXTER
BYPASS EXTERNAL CONTROLS - 24V
DISCONNECT 24V EXTER
AIR INLET TEST
REMOVE AIR INLET TEST POINT
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
BYPASS EXTERNAL CONTROLS - 24V
DISCONNECT 24V EXTER
OBSERVATION RESET APPLIANCE - ERROR CODE
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
VOLTAGE TO DIVERTER VALVE (CH DEMAND)
{GAINPCBACS}
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
INSPECTION HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER FROM THE APPLIANCE
REMOVE PRESSURE GAUGE FROM MANIFOLD
RESISTANCE FLUE SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION RESET APPLIANCE - ENSURE APPLIANCE IS COOL
ENSURE APPLIANCE IS COOL
RESISTANCE FLUE SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLUE SENSOR HARNESS
REMOVE CONNECTOR X5 FROM THE MAIN PCB
REMOVE CONNECTOR FROM THE FLUE SENSOR
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
INSPECTION HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER FROM THE APPLIANCE
REMOVE PRESSURE GAUGE FROM MANIFOLD
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE FLUE SENSOR HARNESS
REMOVE CONNECTOR X5 FROM THE MAIN PCB
REMOVE CONNECTOR FROM THE FLUE SENSOR
VOLTAGE POLARITY
GAIN ACCESS TO THE MAINS CONNECTOR ON THE CONNECTION PCB
INSPECTION HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER FROM THE APPLIANCE
REMOVE PRESSURE GAUGE FROM MANIFOLD
RESISTANCE PRESSURE SWITCH
REMOVE THE LEADS FROM THE PRESSURE SWITCH
INSPECTION PRESSURE SWITCH AND HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER
RESISTANCE FLUE SENSOR HARNESS
REMOVE CONNECTOR X5 FROM THE MAIN PCB
REMOVE CONNECTOR FROM THE FLUE SENSOR
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
OBSERVATION RESET APPLIANCE - ENSURE APPLIANCE IS COOL
ENSURE APPLIANCE IS COOL
INSPECTION HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER FROM THE APPLIANCE
REMOVE PRESSURE GAUGE FROM MANIFOLD
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
VOLTAGE PUMP AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION HEATING FILTER
BOILER DRAINED AND DISCHARGED
RESISTANCE LIMIT THERMOSTAT AND HARNESS
REMOVE CONNECTOR X5 FROM THE MAIN PCB
RESISTANCE LIMIT THERMOSTAT
REMOVE THE LEADS FROM THE LIMIT THERMOSTAT
OBSERVATION RESET APPLIANCE - ENSURE APPLIANCE IS COOL
ENSURE APPLIANCE IS COOL
INSPECTION HYDRAULIC MANIFOLD
DRAIN PRIMARY WATER FROM THE APPLIANCE
REMOVE PRESSURE GAUGE FROM MANIFOLD
VOLTAGE PUMP AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION HEATING FILTER
BOILER DRAINED AND DISCHARGED
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR
REMOVE CONNECTOR FROM THE FLOW SENSOR (RED WIRES)
RESISTANCE RETURN SENSOR HARNESS
REMOVE CONNECTOR X5
INSPECTION JUMPER POSITIONS
GAIN ACCESS TO THE CONNECTION PCB
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE INTERNAL TIMER BYPASS LINK AT X3
SLIDE CONNECTION PCB OUT AND REMOVE CONNECTOR X3
OBSERVATION INTERNAL TIMER BYPASS LINK FITTED
REMOVE BLANKING PANEL FROM LEFT SIDE OF APPLIANCE
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
DISCONNECT INTERNAL TIMER - SELF TEST
SLIDE THE CONNECTION
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE MAINS SUPPLY FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
VOLTAGE MAINS POWER AT CONNECTION PCB
{GAINPCBACS}
SLID
RESISTANCE FUSE F1
REMOVE THE FUSE FROM THE PCB
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
DISCONNECT INTERNAL TIMER - SELF TEST
SLIDE THE CONNECTION
INSPECTION DHW CARTRIDGE
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
DRAIN THE HOT WATER CIRCUIT
OBSERVATION DIVERTER VALVE HEAD OPERATION - DHW
REMOVE THE LOCKING P
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH TEMPERATURE C
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE HARNESS DIVERTER
REMOVE CONNECTOR X3 FROM THE MAIN PCB
DISCONNECT THE HARNESS FROM THE DIVERTER MOTOR HEAD
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION DIVERTER VALVE HEAD OPERATION - CH
REMOVE THE LOCKING P
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT
RESISTANCE IGNITION LEAD
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE AND THE PCB
INSPECTION SPARK ELECTRODE
REMOVE THE SPARK ELECTRODE ASSEMBLY
PRESSURE FAN DURING IGNITION PHASE
ATTACH THE TUBE TO L
INSPECTION SPARK ELECTRODE
REMOVE THE SPARK ELECTRODE ASSEMBLY
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
RESISTANCE DIVERTER MOTOR AND HARNESS - FUSE INVESTIGATION
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP AND HARNESS - FUSE INVESTIGATION
REMOVE CONNECTOR X2
RESISTANCE PUMP (SPEED CONTROL)
DISCONNECT PUMP SPEED CONTROL ELECTRICAL PLUG FROM THE PUMP (RIGHT SIDE)
RESISTANCE PUMP (MAINS SUPPLY)
DISCONNECT MAINS SUPPLY ELECTRICAL PLUG FROM THE PUMP (LEFT SIDE)
RESISTANCE FAN - FUSE INVESTIGATION
GAIN ACCESS TO MAIN
RESISTANCE GAS VALVE - FUSE INVESTIGATION
DISCONNECT THE ELECTRICAL CONNECTOR FROM THE GAS VALVE
RESISTANCE HARNESS DISPLAY PCB
DISCONNECT THE HARNESS FROM THE DISPLAY PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH TEMPERATURE C
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
INSPECTION JUMPER POSITIONS
GAIN ACCESS TO THE CONNECTION PCB
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION SPARK GAP TO BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER AND SPARK GAP TO BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
VOLTAGE CH DEMAND AT MAIN PCB
{GAINPCBACS}
ENSURE NO DEMANDS
OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO THE CONNECTION PCB
BYPASS EXTERNAL CONTROLS - 240V
DISCONNECT 240V EXTE
OBSERVATION IS SPARKING PRESENT
REMOVE IGNITION LEAD FROM SPARK GENERATOR AND MAKE SAFE
PRESSURE GAS INLET
ATTACH PRESSURE GAUGE TO GAS PRESSURE INLET TEST POINT
OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO THE CONNECTION PCB
BYPASS EXTERNAL CONTROLS - 240V
DISCONNECT 240V EXTE
RESISTANCE HALL SENSOR HARNESS
UNCLIP THE HALL SENSOR FROM BELOW THE TURBINE THEN
REMOVE THE CONNECTOR FROM THE HALL SENSOR
INSPECTION FLOW TURBINE
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
DRAIN THE HOT WATER CIRCUIT
RESISTANCE IGNITION LEAD
REMOVE THE IGNITION LEAD FROM THE SPARK ELECTRODE AND THE PCB
PRESSURE EXPANSION VESSEL
APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
OBSERVATION CAN COMBUSTION VALUES BE ADJUSTED
CONNECT FGA TO THE COMBUSTION TEST POINT
COMBUSTION VALUES CORRECTLY ADJUSTED
THE COMBUSTION READI
AIR INLET TEST
REMOVE AIR INLET TEST POINT
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH TEMPERATURE C
VOLTAGE CH DEMAND AT MAIN PCB
{GAINPCBACS}
ENSURE NO DEMANDS
OBSERVATION WHAT TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO THE CONNECTION PCB
BYPASS EXTERNAL CONTROLS - 240V
DISCONNECT 240V EXTE
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
INSPECTION BYPASS OPERATION
APPLIANCE DRAINED AND DISCHARGED
INSPECTION HEATING FILTER
BOILER DRAINED AND DISCHARGED
RESISTANCE HARNESS DIVERTER
REMOVE CONNECTOR X3 FROM THE MAIN PCB
DISCONNECT THE HARNESS FROM THE DIVERTER MOTOR HEAD
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION RESET APPLIANCE - ERROR CODE
ENSURE NO DEMANDS ARE PRESENT
OBSERVATION RESET APPLIANCE - ERROR CODE
ENSURE NO DEMANDS ARE PRESENT
OBSERVATION RESET APPLIANCE - ERROR CODE
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
TEMPERATURE FLUE GAS
PLACE TEMPERATURE PROBE IN THE FLUE SAMPLE TEST POINT
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
RESISTANCE FLUE SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
INSPECTION SPARK ELECTRODE
REMOVE THE SPARK ELECTRODE ASSEMBLY
RESISTANCE PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR X5 FROM THE MAIN PCB
OBSERVATION RESET APPLIANCE - ERROR CODE
ENSURE NO DEMANDS ARE PRESENT
RESISTANCE FLOW SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH TEMPERATURE C
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMPERATURE
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE AS INDICATED BY THE RED ARROW
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH TEMPERATURE C
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE C
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
INSPECTION SILENCER
REMOVE THE BURNER DO
INSPECTION BURNER
REMOVE THE BURNER DOOR ASSEMBLY C/W FAN AND GAS VALVE ASSEMBLY
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
BYPASS INTERNAL PROGRAMMER / TIMER
REMOVE THE INTERNAL
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X3
SLIDE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
TEMPERATURE FLOW - FROST PROTECTION
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE, AS CLOSE TO THE FLOW THERMISTOR AS POSSIBLE.
TEMPERATURE FLOW
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE, AS CLOSE TO THE FLOW THERMISTOR AS POSSIBLE.
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION WHICH DEMAND IS FLASHING
ENSURE NO DEMANDS
OBSERVATION ISOLATE COLD MAINS SUPPLY
ISOLATE THE COLD MAINS SUPPLY
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
RESISTANCE HARNESS X11 / X6
REMOVE CONNECTOR X6 FROM THE MAIN PCB
REMOVE CONNECTOR X11 FROM THE CONNECTION PCB
VOLTAGE MAINS POWER INPUT TO APPLIANCE
GAIN ACCESS TO THE MAINS CONNECTOR ON THE CONNECTION PCB
VOLTAGE MAINS POWER AT MAIN PCB
{GAINPCBACS}
VOLTAGE TO DISPLAY PCB
{GAINPCBACS}
RESISTANCE HARNESS DISPLAY PCB
DISCONNECT THE HARNESS FROM THE DISPLAY PCB
INFORMATION BLANK DISPLAY
THE TESTS CARRIED OU
OBSERVATION BOILER INITIALISATION - NO DISPLAY
ENSURE NO DEMANDS ARE PRESENT
VOLTAGE PUMP AT PCB
{GAINPCBACS}
TEMPERATURE FLOW - FROST PROTECTION
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE, AS CLOSE TO THE FLOW THERMISTOR AS POSSIBLE.
TEMPERATURE FLOW
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE, AS CLOSE TO THE FLOW THERMISTOR AS POSSIBLE.
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE RETURN SENSOR AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
OBSERVATION ISOLATE COLD MAINS SUPPLY
ISOLATE THE COLD MAINS SUPPLY
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
RESISTANCE PUMP MAINS SUPPLY HARNESS
REMOVE CONNECTOR X2
VOLTAGE DEMAND FROM HALL SENSOR
{GAINPCBACS}
ENSURE NO DEMANDS
INSPECTION DHW CARTRIDGE
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
DRAIN THE HOT WATER CIRCUIT
RESISTANCE HALL SENSOR HARNESS
UNCLIP THE HALL SENSOR FROM BELOW THE TURBINE THEN
REMOVE THE CONNECTOR FROM THE HALL SENSOR
INSPECTION FLOW TURBINE
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
DRAIN THE HOT WATER CIRCUIT
System Information
- Total Tests: 754
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control