Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Unclip the hall sensor from below the turbine then
remove the connector from the hall sensor
remove the connector from the hall sensor
Measurement:
Measure the resistance of each of the wires in the hall
sensor harness as stated in the table below.
Expect continuity / zero resistance on each of the wires.
Also visually inspect the harness for good general condition.
sensor harness as stated in the table below.
| Pin on connector X5 | Hall Sensor Connector | 2 (White) | White |
| 3 (Green) | Green |
| 4 (Brown) | Brown |
Expect continuity / zero resistance on each of the wires.
Also visually inspect the harness for good general condition.

Isolate as per TOPs P4
and refit as necessary