GLOWWORM ULTRACOM 2 CXI

GLOBALLY REPLACED

Next: &1, *

FUSE FURTHER INVESTIGATION

NOT USED

Next: nff

CASE REMOVAL

Next: &1599, !f2

POWER UP SELF TEST

ENSURE NO DEMANDS ARE PRESENT

Next: &715, ?10, ?1865

OBSERVATION PUMP RUNS

Next: &31, f2366

OBSERVATION BURNER IGNITION & ESTABLISH

Next: &1725, ?110, ?112, ?114, ?1635

DHW FLOW RATE

Next: &87, f44

OBSERVATION FAN RUNS - DHW DEMAND

TURN HOT TAP ON AND SET FLOW RATE TO 3.0 L/MIN
ENSURE BOILER IS COOL

Next: &29, ?88, ?90

CH OPERATION

Next: &nff, ?560, ?562, ?564

COMBUSTION CHECK

CONNECT FGA TO THE COMBUSTION TEST POINT ON THE BOILER
ENSURE CH SYSTEM IS COOL

Next: &333, f483

DHW OPERATION

Next: &334, ?336, ?338, ?340, ?342

TEST MODES

NOT USED

Next: &nff, f555

INSTALLATION SETTINGS

NOT USED

Next: &nff, f596

INITIAL SETUP

Next: &3, !f716

FAULT CODE F00/F10

NOT USED

Next: &nff, f735

FAULT CODE F23 - F24

NOT USED

Next: &nff, f1060

FAULT CODE F20

NOT USED

Next: &nff, f1199

FAULT CODE F01/F11

NOT USED

Next: &nff, f747

FAULT CODE F84

NOT USED

Next: &nff, f839

FAULT CODE F83

NOT USED

Next: &nff, f782

FAULT CODE F76

NOT USED

Next: &nff, f1378

FAULT CODE F73 - F74

NOT USED

Next: &nff, f931

FAULT CODE F71

NOT USED

Next: &nff, f1192

FAULT CODE F70

NOT USED

Next: &nff, f1422

FAULT CODE F61 TO F67

NOT USED

Next: &nff, f1388

FAULT CODE F49

NOT USED

Next: &nff, f1361

FAULT CODE F32

NOT USED

Next: &nff, f1152

FAULT CODE F26/F77

NOT USED

Next: &nff, f1142

FAULT CODE ERR

NOT USED

Next: &nff, f1582

FAULT CODE F86

NOT USED

Next: &nff, f1172

FAULT CODE F22

NOT USED

Next: &nff, f948

FACTORY RESET

NOT USED

Next: &nff, f1160

FUSE FURTHER INVESTIGATION

NOT USED

Next: &nff, f2486

FAULT CODE HISTORY

NOT USED

Next: &nff, f1594

OBSERVATION DISPLAY

ON/OFF SWITCH ON (RECESSED POSITION, PUSHED IN)

Next: &7, ?1600, ?1631, ?1674, ?2110

STATUS CODES

NOT USED

Next: &nff, f1671

LITE DIAGNOSTIC

DIAGNOSIS RELIES ON

Next: &nff, !f2316

QUICK ACCESS DATA AND INFORMATION

THE TABLE BELOW SHOW

Next: &nff, !f2318

HEADER FOR QADAI FLOW THERMISTOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2320

HEADER FOR QADAI RETURN THERMISTOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2324

HEADER FOR QADAI RESISTANCE GAS VALVE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2328

HEADER FOR QADAI VOLTAGE GAS VALVE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2333

HEADER FOR QADAI PRESSURE SENSOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2337

HEADER FOR QADAI FAN VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2342

HEADER FOR QADAI DIVERTER VALVE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2346

HEADER FOR QADAI PUMP VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2358

HEADER FOR QADAI PUMP AND HARNESS ERP

INTENTIONALL LEFT BLANK FOR QADAI

Next: &nff, f2461

HEADER FOR QADAI PUMP VOLTAGE ERP

INTENTIONALL LEFT BLANK FOR QADAI

Next: &nff, f2465

FAN DOES NOT RUN

SENSOR - TEMPERATURE

Next: End

FAN DOES NOT RUN 2

SENSOR - TEMPERATURE

Next: End

FAN DOES NOT RUN

PCB - MAIN

Next: End

FAULT CODE F23 - F24

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAULT CODE F23 - F24

MOTOR/PUMP

Next: End

FAN DOES NOT RUN

HARNESS DIN - MAIN

Next: End

FAULT CODE F23 - F24

SENSOR - TEMPERATURE

Next: End

FAULT CODE F23 - F24 2

SENSOR - TEMPERATURE

Next: End

FAULT CODE F23 - F24 4

SENSOR - TEMPERATURE

Next: End

FAULT CODE F23 - F24 3

SENSOR - TEMPERATURE

Next: End

FAULT CODE F23 - F24

VALVE ISOLATION

Next: End

FAULT CODE F23 - F24

HEAT EXCHANGER - WATER WAYS

Next: End

FAULT CODE F23 - F24

FILTER - HEATING

Next: End

FAULT CODE F23 - F24 2

VALVE ISOLATION

Next: End

FAULT CODE F26

GAS VALVE

Next: End

FAULT CODE F26

PCB - MAIN

Next: End

FACTORY RESET

Z REDIRECTION

Next: End

FAULT CODE F86

WIRE LINK UNDER FLOOR HEATING

Next: End

FAULT CODE F86

UNDER FLOOR SENSOR

Next: End

FAULT CODE F86

PCB - MAIN

Next: End

FAULT CODE F86 2

PCB - MAIN

Next: End

FAULT CODE F71

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAULT CODE F71

SENSOR - TEMPERATURE

Next: End

FAULT CODE F71

PCB - MAIN

Next: End

FAULT CODE F20

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20 2

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAULT CODE F20

VALVE ISOLATION

Next: End

SELF TEST

FROST PROTECTION NORMAL OPERATION

Next: End

FAULT CODE F20 4

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20 3

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20 5

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20 6

SENSOR - TEMPERATURE

Next: End

FAULT CODE F20

Next: End

FAULT CODE F20

FILTER - HEATING

Next: End

FAULT CODE F20

HEAT EXCHANGER - WATER WAYS

Next: End

FAULT CODE F20 4

MOTOR/PUMP

Next: End

FAULT CODE F20

PCB - MAIN - PUMP OVER-RUN

Next: End

FAULT CODE F32 3

PCB - MAIN

Next: End

FAULT CODE F32

PCB - MAIN

Next: End

FAULT CODE F32

HARNESS DIN - MAIN

Next: End

FAULT CODE F32 2

PCB - MAIN

Next: End

FAULT CODE F49

PCB - MAIN

Next: End

FAULT CODE F49 2

PCB - MAIN

Next: End

FAULT CODE F83

MOTOR/PUMP

Next: End

FAULT CODE F76

CABLE - SENSOR TO HARNESS - HEAT EXCHANGER

Next: End

FAULT CODE F76

PCB - MAIN

Next: End

FAULT CODE F70

PCB - MAIN

Next: End

FAULT CODE F70

MAIN DSN NUMBER

Next: End

SELF TEST

SENSOR - TEMPERATURE

Next: End

FAULT CODE ERR

CABLE - A1

Next: End

BURNER DOES NOT IGNITE

PCB - MAIN & GAS VALVE

Next: End

DHW FLOW RATE

FLOW RESTRICTOR

Next: End

FAULT CODE HISTORY

Z REDIRECTION

Next: End

NO DISPLAY

FUSE (FUSED SPUR)

Next: End

NO DISPLAY

SYSTEM PRESSURE SENSOR

Next: End

NO DISPLAY

FAN

Next: End

FAULT CODES

Z REDIRECTION

Next: End

STATUS CODES

Z REDIRECTION

Next: End

GAS RATIO ADJUSTMENT

GAS VALVE ADJUSTMENT

Next: End

CH DOES NOT RESPOND 1

PCB - MAIN

Next: End

CH DOES NOT RESPOND 2

PCB - MAIN

Next: End

CH DOES NOT RESPOND

PCB - MAIN

Next: End

CH DOES NOT RESPOND 4

PCB - MAIN

Next: End

CH DOES NOT RESPOND 3

PCB - MAIN

Next: End

BOILER FIRES SELF TEST

PCB - MAIN

Next: End

BOILER FIRES SELF TEST 2

PCB - MAIN

Next: End

SELF TEST 3

PCB - MAIN

Next: End

SELF TEST 2

PCB - MAIN

Next: End

LOW PRESSURE

SYSTEM PRESSURE

Next: End

SYSTEM PRESSURE

DEVICE - FILLING

Next: End

FAULT CODE F20

DEVICE - FILLING

Next: End

FAULT CODE F22

DEVICE - FILLING

Next: End

FAULT CODE F23

DEVICE - FILLING

Next: End

FAULT CODE F73-74

DEVICE - FILLING

Next: End

FAULT CODE F83

DEVICE - FILLING

Next: End

CASE OFF

DIRECTION CHOICE OR CONTINUE

Next: End

DHW COOL RADS COOL

DEVICE - FILLING

Next: End

DHW COOL RADS COOL

MOTOR/PUMP

Next: End

DHW COOL RADS COOL

AIR BOX

Next: End

DHW COOL RADS COOL

SENSOR - TEMPERATURE INSTALLATION

Next: End

DHW COOL RADS COOL

SENSOR - TEMPERATURE

Next: End

DHW COOL RADS COOL 2

SENSOR - TEMPERATURE

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER - WATER WAYS

Next: End

DHW COOL RADS COOL

FILTER - HEATING

Next: End

DHW COOL RADS COOL

MAIN DSN NUMBER

Next: End

DHW TOO HOT

SENSOR - TEMPERATURE INSTALLATION

Next: End

DHW TOO HOT

SENSOR - TEMPERATURE

Next: End

DHW TOO HOT 2

SENSOR - TEMPERATURE

Next: End

DHW RUNS HOT THEN COLD

MOTOR/PUMP

Next: End

DHW RUNS HOT COOL

SENSOR - TEMPERATURE INSTALLATION

Next: End

DHW RUNS HOT THEN COLD

HEAT EXCHANGER - WATER WAYS

Next: End

DHW RUNS HOT THEN COLD

FILTER - HEATING

Next: End

DHW RUNS HOT THEN COLD

SENSOR - TEMPERATURE

Next: End

DHW RUNS HOT THEN COLD 2

SENSOR - TEMPERATURE

Next: End

DHW RUNS HOT THEN COOL

DEVICE - FILLING

Next: End

NO DISPLAY

FUSE PCB

Next: End

NO DISPLAY

PCB - MAIN

Next: End

BURNER DOES NOT IGNITE 2

HARNESS DIN - MAIN

Next: End

FAN DOES NOT RUN

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAN DOES NOT RUN 4

SENSOR - TEMPERATURE

Next: End

FAN DOES NOT RUN 3

SENSOR - TEMPERATURE

Next: End

RESET OPTION

Z REDIRECTION

Next: End

BURNER DOES NOT IGNITE 3

HARNESS DIN - MAIN

Next: End

BURNER DOES NOT IGNITE 4

HARNESS DIN - MAIN

Next: End

BURNER DOES NOT ESTABLISH

PCB - MAIN

Next: End

BURNER DOES NOT ESTABLISH

ELECTRODE - IGNITION

Next: End

BURNER DOES NOT ESTABLISH

HARNESS DIN - MAIN

Next: End

DOES NOT EST

SYPHON

Next: End

DHW COOL RADS COOL

GAS INLET PRESSURE

Next: End

FAULT CODE F83 2

SENSOR - TEMPERATURE

Next: End

FAULT CODE F83

SENSOR - TEMPERATURE

Next: End

FAULT CODE F83 4

SENSOR - TEMPERATURE

Next: End

FAULT CODE F83 3

SENSOR - TEMPERATURE

Next: End

FAULT CODE F61-67

GAS VALVE

Next: End

FAULT CODE F61 - 67

PCB - MAIN & GAS VALVE

Next: End

FAULT CODE F61 - 67

MAIN CONNECTIONS

Next: End

FAULT CODE F61 - 67

MAIN DSN NUMBER

Next: End

FAULT CODE F61 - 67

PCB - MAIN

Next: End

DHW NOT RECOGNISED

PCB - MAIN

Next: End

F84 - RUNNING SLOW

MOTOR/PUMP

Next: End

FAULT CODE F84 2

PCB - MAIN

Next: End

DHW COOL RADS COOL 2

MAIN DSN NUMBER

Next: End

BURNER DOES NOT IGNITE 2

ELECTRODE - IGNITION

Next: End

BURNER DOES NOT IGNITE

FLUE

Next: End

BURNER DOES NOT IGNITE

BURNER

Next: End

BURNER DOES NOT IGNITE

HEAT EXCHANGER

Next: End

F70 HAD TO SAVE INCORRECT DS NUMBER FIRST

MAIN DSN NUMBER

Next: End

FAULT CODE F32 3

HARNESS DIN - MAIN

Next: End

FAULT CODE F32 3

FAN

Next: End

FAULT CODE F32 2

HARNESS DIN - MAIN

Next: End

FAULT CODE F32 2

FAN

Next: End

BLANK FOR LITE DIAGNOSTIC

Z REDIRECTION

Next: End

BLANK FOR QADAI

Z REDIRECTION

Next: End

QADAI RETURN

SENSOR - TEMPERATURE

Next: End

QADAI FLOW

SENSOR - TEMPERATURE

Next: End

QADAI VOLTAGE TO DIVERTER VALVE

PCB - MAIN

Next: End

QADAI

GAS VALVE

Next: End

QADAI VOLTAGE TO GAS VALVE

PCB - MAIN

Next: End

QADAI

PCB - MAIN

Next: End

QADAI

MOTOR/PUMP

Next: End

FAN QADAI

PCB - MAIN

Next: End

PUMP DOES NOT RUN

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN

PCB - MAIN

Next: End

BURNER DOES NOT IGNITE

GAS INLET PRESSURE

Next: End

PUMP DOES NOT RUN 1

PCB - MAIN

Next: End

PUMP DOES NOT RUN 3

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 2

PCB - MAIN

Next: End

PUMP DOES NOT RUN 5

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 7

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 3

PCB - MAIN

Next: End

PUMP DOES NOT RUN 4

PCB - MAIN

Next: End

PUMP DOES NOT RUN 8

MOTOR/PUMP

Next: End

QADAI RESISTANCE

MOTOR/PUMP

Next: End

NO VOLTAGE TO ERP PUMP

PCB - MAIN

Next: End

PUMP NOT RUNNING ERP

PCB - MAIN

Next: End

BURNER DOES NOT IGNITE 2

GAS VALVE

Next: End

ERP FUSE FURTHER INVESTIGATION

MOTOR/PUMP

Next: End

FUSE FURTHER INVESTIGATION

MOTOR/PUMP

Next: End

ERP PUMP NOT RUNNING

PUMP CABLE (ERP)

Next: End

ERP FAULT CODE F83

PUMP CABLE (ERP)

Next: End

PUMP NOT RUNNING ERP F83

PCB - MAIN

Next: End

ERP FAULT CODE F84

PUMP CABLE (ERP)

Next: End

PUMP NOT RUNNING ERP F84

PCB - MAIN

Next: End

ERP FAULT CODE F23 F24

PUMP CABLE (ERP)

Next: End

PUMP NOT RUNNING ERP F23 F24

PCB - MAIN

Next: End

ERP FAULT CODE F20

PUMP CABLE (ERP)

Next: End

PUMP NOT RUNNING ERP F20

PCB - MAIN

Next: End

QADAI

SYSTEM PRESSURE SENSOR

Next: End

QADAI

SENSOR - FLOW

Next: End

SELF TEST 2

SENSOR - TEMPERATURE

Next: End

BURNER DOES NOT IGNITE

SYPHON

Next: End

BURNER NOISY/ BAFFLES OUT

SYPHON

Next: End

BURNER NOISY/ BAFFLES OUT

GAS INLET PRESSURE

Next: End

BURNER NOISY/ BAFFLES OUT

AIR BOX

Next: End

BURNER NOISY/ BAFFLES OUT

FLUE

Next: End

BURNER NOISY/ BAFFLES OUT

BURNER

Next: End

BURNER NOISY/ BAFFLES OUT

HEAT EXCHANGER

Next: End

BURNER DOES NOT IGNITE

AIR BOX

Next: End

DHW COOL RADS HEAT

PCB - MAIN

Next: End

DHW COOL RADS HEAT 2

PCB - MAIN

Next: End

DHW COOL RADS HEAT

HARNESS DIN - MAIN

Next: End

TYPE DIAG PROCEDURE

DIRECTION CHOICE OR CONTINUE

Next: End

DHW FLOW RATE

VALVE ISOLATION DHW

Next: End

FLOW RATE

COLD WATER SUPPLY

Next: End

COMBUSTION CHECK

GAS INLET PRESSURE

Next: End

AIR/GAS RATIO INCORRECT

FLUE

Next: End

AIR/GAS RATIO INCORRECT

COMBUSTION SEALS

Next: End

AIR/GAS RATIO INCORRECT

AIR BOX

Next: End

AIR/GAS RATIO INCORRECT

SYPHON

Next: End

AIR/GAS RATIO INCORRECT

BURNER

Next: End

AIR/GAS RATIO INCORRECT

HEAT EXCHANGER

Next: End

TEST MODE

DIRECTION CHOICE OR CONTINUE

Next: End

RADS DO NOT HEAT

VALVE ISOLATION

Next: End

RADS DO NOT HEAT

MOTOR/PUMP

Next: End

RADS DO NOT HEAT

PCB - MAIN

Next: End

RADS DO NOT HEAT

HARNESS DIN - MAIN

Next: End

RADS DO NOT HEAT 2

PCB - MAIN

Next: End

SYSTEM PRESSURE RISES

EXPANSION VESSEL

Next: End

RAD TEMP LOW

SENSOR - TEMPERATURE

Next: End

RAD TEMP LOW 2

PCB - MAIN

Next: End

CH RAD TEMP LOW

ADJUSTMENT PARAMETER SETTING

Next: End

RADS DO NOT HEAT

BYPASS

Next: End

INSTALLATION SETTINGS

DIRECTION CHOICE OR CONTINUE

Next: End

RAD TEMP LOW 2

SENSOR - TEMPERATURE

Next: End

INITIAL SET UP

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F00/F10

PCB - MAIN

Next: End

FAULT CODE F00/F10

SENSOR - TEMPERATURE

Next: End

FAULT CODE F01/F11

SENSOR - TEMPERATURE

Next: End

FAULT CODE F01/F11

PCB - MAIN

Next: End

FAULT CODE F83

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAULT CODE F83

HEAT EXCHANGER - WATER WAYS

Next: End

FAULT CODE F83

FILTER - HEATING

Next: End

FAULT CODE F84

SENSOR - TEMPERATURE INSTALLATION

Next: End

FAULT CODE F84

SENSOR - TEMPERATURE

Next: End

FAULT CODE F84 2

SENSOR - TEMPERATURE

Next: End

FAULT CODE F84

PCB - MAIN

Next: End

FAULT CODE F73 - F74

PCB - MAIN

Next: End

FAULT CODE F73 - F74

HARNESS DIN - MAIN

Next: End

FAULT CODE F73 - F74 2

PCB - MAIN

Next: End

FAULT CODE F22

PCB - MAIN

Next: End

FAULT CODE F22 2

PCB - MAIN

Next: End

DHW NOT RECOGNISED

HARNESS DIN - MAIN

Next: End

FAN DOES NOT RUN 2

PCB - MAIN

Next: End

BOILER RESET

FAULT CODE F22

Next: End

FAN DOES NOT RUN

FAN

Next: End

FAULT CODE F23 - F24 2

PCB - MAIN

Next: End

FAULT CODE F23 - F24

FAULT CODE RESET

Next: End

FAULT CODE F23 - F24

HEAT EXCHANGER - PLATE TO PLATE

Next: End

FAULT CODE F26

HARNESS DIN - MAIN

Next: End

FAULT CODE F26

FAULT CODE RESET

Next: End

FACTORY RESET

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F86

FAULT CODE RESET

Next: End

FAULT CODE F86 2

FAULT CODE RESET

Next: End

FAULT CODE F71

FAULT CODE RESET

Next: End

FAULT CODE F20

PCB - MAIN

Next: End

FAULT CODE F20

FAULT CODE RESET

Next: End

FAULT CODE F20 2

PCB - MAIN

Next: End

FAULT CODE F20 3

PCB - MAIN

Next: End

FAULT CODE F20

HEAT EXCHANGER - PLATE TO PLATE

Next: End

FAULT CODE F32

FAN

Next: End

FAULT CODE F32

FAULT CODE RESET

Next: End

FAULT CODE RESET - F49

FAULT CODE RESET - F49

Next: End

FAULT CODE F49

EBUS CONTROLS

Next: End

FAULT CODE F76

FAULT CODE RESET

Next: End

HEAT EXCHANGER - THERMAL FUSE

HEAT EXCHANGER - THERMAL FUSE

Next: End

FAULT CODE F70

FAULT CODE RESET

Next: End

FAULT CODE F70

FACTORY RESET

Next: End

FAULT CODE F70

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE ERR

FAULT CODE RESET

Next: End

FAULT CODE ERR

FACTORY RESET

Next: End

FAULT CODE ERR

PCB - INTERFACE

Next: End

DHW FLOW RATE

HEAT EXCHANGER - PLATE TO PLATE

Next: End

FAULT CODE HISTORY

DIRECTION CHOICE OR CONTINUE

Next: End

NO DISPLAY

Next: End

FUSE FURTHER INVESTIGATION

Z REDIRECTION

Next: End

FAULT CODES

DIRECTION CHOICE OR CONTINUE

Next: End

BURNER DOES NOT IGNITE

PCB - MAIN - HARNESS DIN - MAIN

Next: End

STATUS CODES

DIRECTION CHOICE OR CONTINUE

Next: End

CH DOES NOT RESPOND 6

INTERNAL PROGRAMMER

Next: End

CH DOES NOT RESPOND

EBUS CONTROLS

Next: End

CH DOES NOT RESPOND 8

INTERNAL PROGRAMMER

Next: End

BOILER FIRES SELF TEST 2

INTERNAL PROGRAMMER

Next: End

SELF TEST

EBUS CONTROLS

Next: End

SELF TEST 2

EBUS CONTROLS

Next: End

LOW SYSTEM PRESSURE

Z REDIRECTION

Next: End

LOW SYSTEM PRESSURE 2

SYSTEM PRESSURE SENSOR

Next: End

LOW SYSTEM PRESSURE

SYSTEM PRESSURE SENSOR

Next: End

LOW SYSTEM PRESSURE

INLET BLOCK ASSEMBLY

Next: End

FAULT CODE F20

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F20 2

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F20

INLET BLOCK ASSEMBLY

Next: End

FAULT CODE F22

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F22 2

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F22

INLET BLOCK ASSEMBLY

Next: End

FAULT CODE F23 - F24

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F23 - F24 2

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F23 - F24

INLET BLOCK ASSEMBLY

Next: End

FAULT CODE F73 - F74 2

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F73 - F74 3

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F73 - F74

INLET BLOCK ASSEMBLY

Next: End

FAULT CODE F83

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F83 2

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F83

INLET BLOCK ASSEMBLY

Next: End

DHW COOL RADS COOL 2

SYSTEM PRESSURE SENSOR

Next: End

DHW COOL RADS COOL

SYSTEM PRESSURE SENSOR

Next: End

DHW COOL RADS COOL

INLET BLOCK ASSEMBLY

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER - PLATE TO PLATE

Next: End

DHW COOL RADS COOL

PCB - MAIN

Next: End

DHW COOL RADS COOL

DIRECTION CHOICE OR CONTINUE

Next: End

DHW TOO HOT

PCB - MAIN

Next: End

DHW RUNS HOT THEN COLD

HEAT EXCHANGER - PLATE TO PLATE

Next: End

DHW RUNS HOT THEN COLD

PCB - MAIN

Next: End

DHW RUNS HOT THEN COOL

SYSTEM PRESSURE SENSOR

Next: End

DHW RUNS HOT THEN COOL 2

SYSTEM PRESSURE SENSOR

Next: End

DHW RUNS HOT THEN COOL

INLET BLOCK ASSEMBLY

Next: End

NO DISPLAY

DIRECTION CHOICE OR CONTINUE

Next: End

NO DISPLAY 2

PCB - INTERFACE

Next: End

BURNER DOES NOT IGNITE 2

FAN

Next: End

DHW NOT RECOGNISED 2

PCB - MAIN

Next: End

RESET OPTIONS

DIRECTION CHOICE OR CONTINUE

Next: End

BURNER DOES NOT IGNITE

SPARK GENERATOR

Next: End

BURNER DOES NOT IGNITE 2

PCB - MAIN

Next: End

BURNER DOES NOT ESTABLISH 2

PCB - MAIN

Next: End

BURNER DOES NOT ESTABLISH

SPARK GENERATOR

Next: End

FAULT CODE F83

PCB - MAIN

Next: End

FAULT CODE F61 - 67

FAULT CODE RESET

Next: End

FAULT CODE F61 - 67

PCB - MAIN - HARNESS DIN - MAIN

Next: End

FAULT CODE F61 TO F67

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE F61 - 67

FACTORY RESET

Next: End

INTERNALLY SHORTED

SENSOR - FLOW

Next: End

FAULT CODE F84

FAULT CODE RESET

Next: End

DHW COOL RADS COOL - GAS RATE LOW

PCB - MAIN

Next: End

DHW COOL RADS COOL 2

DIRECTION CHOICE OR CONTINUE

Next: End

BURNER DOES NOT IGNITE

GAS VALVE

Next: End

FAULT CODE F32 5

PCB - MAIN

Next: End

FAULT CODE F32 4

PCB - MAIN

Next: End

FLOW THERMISTOR

RESULT AS EXPECTED

Next: End

RETURN THERMISTOR

RESULT AS EXPECTED

Next: End

GAS VALVE

RESULT AS EXPECTED

Next: End

DIVERTER VALVE

RESULT AS EXPECTED

Next: End

GAS VALVE VOLTAGE

RESULT AS EXPECTED

Next: End

PRESSURE SENSOR

RESULT AS EXPECTED

Next: End

FAN

RESULT AS EXPECTED

Next: End

PUMP VOLTAGE

RESULT AS EXPECTED

Next: End

MOTOR/PUMP

RESULT AS EXPECTED

Next: End

PUMP DOES NOT RUN 2

MOTOR/PUMP

Next: End

BURNER DOES NOT IGNITE

ELECTRODE - IGNITION

Next: End

PUMP DOES NOT RUN 1

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 4

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 6

MOTOR/PUMP

Next: End

PUMP DOES NOT RUN 9

MOTOR/PUMP

Next: End

BURNER DOES NOT IGNITE

PCB - MAIN

Next: End

ERP PUMP

RESULT AS EXPECTED

Next: End

PUMP VOLTAGE ERP

RESULT AS EXPECTED

Next: End

BURNER DOES NOT IGNITE

HARNESS DIN - MAIN

Next: End

ERP 1

MOTOR/PUMP

Next: End

NO DISPLAY ERP

FUSE FURTHER INVESTIGATION

Next: End

NO DISPLAY

FUSE FURTHER INVESTIGATION

Next: End

ERP FAULT CODE F83

MOTOR/PUMP

Next: End

ERP FAULT CODE F84

MOTOR/PUMP

Next: End

ERP FAULT CODE F23 F24

MOTOR/PUMP

Next: End

ERP FAULT CODE F20

MOTOR/PUMP

Next: End

FLOW SENSOR

RESULT AS EXPECTED

Next: End

BURNER NOISY/ BAFFLES OUT

GAS VALVE

Next: End

SELF TEST

PCB - MAIN

Next: End

DHW COOL RADS HEAT

VALVE - ASSEMBLED

Next: End

DHW COOL RADS HEAT

THREE WAY VALVE - MOTOR

Next: End

DHW COOL RADS HEAT 2

THREE WAY VALVE - MOTOR

Next: End

COMBUSTION CHECK

Z REDIRECTION

Next: End

DHW FLOW RATE

SENSOR - FLOW

Next: End

DHW FLOW RATE

FILTER STEEL - FLOW SENSOR

Next: End

AIR/GAS RATIO INCORRECT

GAS VALVE

Next: End

TEST MODE

Z REDIRECTION

Next: End

RADS DO NOT HEAT

THREE WAY VALVE - MOTOR

Next: End

RADS DO NOT HEAT 2

THREE WAY VALVE - MOTOR

Next: End

SYSTEM PRESSURE RISES

PIPE EXPANSION VESSEL

Next: End

RAD TEMP LOW

Z REDIRECTION

Next: End

RADS DO NOT HEAT

Next: End

INSTALLATION SETTINGS

Z REDIRECTION

Next: End

RAD TEMP LOW

PCB - MAIN

Next: End

FAULT CODE F00/F10

FAULT CODE RESET

Next: End

FAULT CODE F00/F10

HARNESS DIN - MAIN

Next: End

FAULT CODE F01/F11

HARNESS DIN - MAIN

Next: End

FAULT CODE F01/F11

FAULT CODE RESET

Next: End

FAULT CODE F83

HEAT EXCHANGER - PLATE TO PLATE

Next: End

FAULT CODE F83

FAULT CODE RESET

Next: End

FAULT CODE F73 - F74

SYSTEM PRESSURE SENSOR

Next: End

FAULT CODE F73 - F74

FAULT CODE RESET

Next: End

DHW NOT RECOGNISED

SENSOR - FLOW

Next: End

CH SYMBOL FLASHING AND CH FLOW TEMPERATURE BELOW 12 °C (FIG 2)

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p11

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p234

BURNER IGNITES SMOOTHLY BUT DOES NOT ESTABLISH - SPARKING CONTINUES

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p2126

BURNER IGNITES BUT IS NOISY AND/OR BAFFLES OUT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p279

BOILER GOES TO FAULT CODE F20 - TEMPERATURE BELOW 97°C

CHARACTERISTIC TEST FROM RUN BOILER TO MAX TEMP - FAULT CODE F20

Next: p1302

BOILER FLOW TEMPERATURE EXCEEDS 85°C AND BOILER STILL FIRED

CHARACTERISTIC TEST FROM RUN BOILER TO MAX TEMP - FAULT CODE F20

Next: p1304

FAN DOES NOT RUN

CHARACTERISTIC TEST FROM ? OBSERVATION FAN RUNS - FAULT CODE F32

Next: p1344

FAN RUNS AND/OR STOPS AND RESTARTS - FAULT CODE F32 OCCURS

CHARACTERISTIC TEST FROM ? OBSERVATION FAN RUNS - FAULT CODE F32

Next: p2310

DISPLAY NOT ILLUMINATED (BLANK)

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY

Next: p1601

FAULT CODE DISPLAYED

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY

Next: p1632

FAULT CODE F32 DISPLAYED

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p2305

LOW SYSTEM PRESSURE DISPLAYED

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY

Next: p1941

24 VOLT EXTERNAL CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED

Next: p1846

EBUS CONTROLS FITTED

CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED

Next: p1854

CH SYMBOL FLASHING AND CH FLOW TEMP ABOVE 12°C (FIG 3)

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p1867

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1956

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1958

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1963

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1965

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1971

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1973

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1979

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1981

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1987

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1989

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1995

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p1997

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p2006

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p2008

SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p2062

MANIFOLD RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

Next: !p2064

RESET DISPLAYED

CHARACTERISTIC TEST FROM OBSERVATION DISPLAY

Next: p2111

GAS RATE INCORRECT

Next: p2274

TEMPERATURE RISE UNSATISFACTORY, RADIATORS HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p346

TEMPERATURE RISE UNSATISFACTORY, RADIATORS REMAIN COOL

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p1999

DHW TOO HOT

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p2033

DHW RUNS HOT THEN COOL

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p2040

FLOW SENSOR RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR FLOW - DHW

Next: !p52

FILTER RESTRICTED AND/OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION SENSOR FLOW - DHW

Next: !p54

BOILER REACHES TEMPERATURE RADIATORS DO NOT HEAT

CHARACTERISTIC TEST FROM CH OPERATION

Next: p561

EXCESSIVE SYSTEM PRESSURE AS CH TEMPERATURE RISES

CHARACTERISTIC TEST FROM CH OPERATION

Next: p563

BOILER AND RADIATOR TEMPERATURE LOW

CHARACTERISTIC TEST FROM CH OPERATION

Next: p565

FAN DOES NOT RUN - DHW DEMAND RECOGNISED (TAP SYMBOL FLASHING)

CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - DHW DEMAND

Next: p99

FAN DOES NOT RUN - DHW DEMAND NOT RECOGNISED (TAP SYMBOL NOT FLASHING)

CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - DHW DEMAND

Next: p92

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p102, !f103

RESET APPLIANCE - FAULT CODE F20 TO F24

ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL

Next: p1061, f1089

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1090, !f1091

RESISTANCE GAS VALVE AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: p1147, f1144

RESISTANCE GAS VALVE

REMOVE LEFT - HAND SIDE BOILER CASE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE

Next: !p1148, !f1149

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: p1153, !f1339

FACTORY RESET PROCEDURE

FACTORY RESET PRO

Next: !p1161, !f1162

OBSERVATION UNDERFLOOR HEATING

Next: p1175, f1180

RESISTANCE SENSOR UNDER FLOOR

{GAINPCBACS}
REMOVE UNDER FLOOR HEATING SENSOR CONNECTOR FROM X18 ON THE PCB

Next: p1185, !f1186

RESET APPLIANCE - FAULT CODE F20 TO F24

ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL

Next: p1206, f1201

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1202, !f1203

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: p1314, !f1321

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1362, f1363

OBSERVATION ARE ANY EBUS CONTROLS FITTED

{GAINPCBACS}

Next: p1364, !f1365

RESISTANCE THERMAL FUSE AND HARNESS

REMOVE CONNECTOR X20 FROM THE PCB

Next: p1384, f1380

RESISTANCE HARNESS THERMAL FUSE

REMOVE CONNECTOR X20 FROM THE PCB
REMOVE CONNECTOR TO THERMAL FUSE

Next: !p1387, !f1382

RESET APPLIANCE - FAULT CODE F61 - F67

ENSURE NO DEMANDS ARE PRESENT

Next: p2231, f2235

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1423, f1424

OBSERVATION DSN NUMBER

PARAMETER DSN NUM

Next: p2300, f1426

DSN NUMBER ALTERED CORRECTLY

THE DSN PARAMETER IS

Next: !p1429, !f1430

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1583, f1584

FACTORY RESET - PCB MAIN

FACTORY RESET PRO

Next: !p1585, f1586

RESISTANCE HARNESS INTERFACE

REMOVE CONNECTOR X51 FROM THE PCB
REMOVE PCB TO INTERFACE PCB CONNECTOR

Next: !p1587, !f1588
Next: !p1595, !f1596

RESISTANCE FUSE (FUSED SPUR)

REMOVE FUSE FROM FUSED SPUR

Next: !p1604, f1605

FUSE FURTHER INVESTIGATION (FUSED SPUR)

THE INFORMATION PROV

Next: !p1606, !f1607

ACTIVATE STATUS CODES

STATUS CODES OF T

Next: !p1672, !f1673

OBSERVATION EXTERNAL CONTROLS FITTED

{GAINPCBACS}

Next: p1858, ?1845, ?1853

OBSERVATION EXTERNAL CONTROLS FITTED - SELF TEST

{GAINPCBACS}

Next: p1881, f1885

DISCONNECT INTERNAL PROGRAMMER (SELF TEST)

GAIN ACCESS TO UPPER

Next: !p1879, !f1880

DISCONNECT EBUS CONTROLS - SELF TEST

REMOVE EBUS WIRING C

Next: !p1886, !f1887

DISCONNECT EBUS CONTROLS - SELF TEST

REMOVE EBUS WIRING C

Next: !p1888, !f1889

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1953, !f1952

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1960, !f1966

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1976, !f1982

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1984, !f1990

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1992, !f1998

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p2001, !f2002

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: p2022, !f2023

DSN NUMBER ALTERED CORRECTLY

THE DSN PARAMETER IS

Next: !p2028, !f2029

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: p2048, !f2049

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p2057, !f2058

FUSE FURTHER INVESTIGATION

THE INFORMATION PROV

Next: !p2092, !f2093

VOLTAGE FAN HALL SENSOR AT PCB

{GAINPCBACS}

Next: p2122, f2100

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: !p2101, !f2102

RESISTANCE HARNESS SPARK GENERATOR

REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB

Next: !p2115, !f2116

INSPECTION ELECTRODE IGNITION

REMOVE IGNITION ELECTRODE

Next: p2132, !f2133

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2198, !f2199

RESISTANCE GAS VALVE AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: p2236, f2237

RESISTANCE GAS VALVE

REMOVE LEFT - HAND SIDE BOILER CASE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE

Next: !p2238, !f2239

DSN NUMBER ALTERED CORRECTLY

THE DSN PARAMETER IS

Next: !p2244, !f2245

VOLTAGE FLOW SENSOR - SEND (FLOW SENSOR DISCONNECTED)

REMOVE THE CONNECTOR FROM THE DHW FLOW SENSOR AND MAKE SAFE

Next: !p2249, !f2250

DSN NUMBER ALTERED CORRECTLY

THE DSN PARAMETER IS

Next: !p2282, !f2283

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: !p2321, !f2340

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p2325, !f2326

RESISTANCE GAS VALVE

REMOVE LEFT - HAND SIDE BOILER CASE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE

Next: !p2331, !f2349

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE AND MAKE SAFE

Next: !p2351, !f2350

VOLTAGE SENSOR SYSTEM PRESSURE - RETURN

{GAINPCBACS}

Next: !p2352, !f2568

VOLTAGE FAN 22 VDC AT PCB

REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY, LEAVE IN A SAFE LOCATION

Next: !p2355, !f2365

VOLTAGE DIVERTER VALVE AT PCB - DIVERTER DISCONNECTED

REMOVE ELECTRICAL CONNECTOR TO DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS ARE PRESENT

Next: !p2347, !f2348

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2359, !f2360

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: !p2363, !f2364

OBSERVATION TYPE OF PUMP

Next: p2367, f2369

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: p2370, !f2371

VOLTAGE SPARK GENERATOR AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND MAKE SAFE

Next: p238, f2098

OBSERVATION TYPE OF PUMP

Next: p2563, f2380

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: p2381, !f2435

OBSERVATION TYPE OF PUMP

Next: p2558, f2391

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: p2392, !f2448

OBSERVATION TYPE OF PUMP

Next: p2548, f2405

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: p2406, !f2444

OBSERVATION TYPE OF PUMP

Next: p2553, f2418

RESISTANCE PUMP AND HARNESS

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: p2419, !f2445

RESISTANCE GAS VALVE AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: !p246, f247

RESISTANCE PUMP AND HARNESS ERP

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: !p2462, !f2463

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2466, !f2467

RESISTANCE GAS VALVE

REMOVE LEFT - HAND SIDE BOILER CASE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE

Next: !p1669, !f1589

OBSERVATION TYPE OF PUMP

Next: p2540, f2543

RESISTANCE GAS VALVE

REMOVE LEFT - HAND SIDE BOILER CASE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE

Next: !p252, !f253

RESISTANCE PUMP AND HARNESS (FUSE FURTHER INVESTIGATION)

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: !p2544, !f2545

VOLTAGE FLOW SENSOR DHW - RETURN

{GAINPCBACS}
ENSURE A FLOW RATE OF 3 LITRES PER MINUTE

Next: !p2571, !f2572

VOLTAGE DIVERTER VALVE AT PCB

{GAINPCBACS}
ENSURE NO DEMANDS ARE PRESENT

Next: p369, f383

VOLTAGE DIVERTER VALVE AT PCB - DIVERTER DISCONNECTED

REMOVE ELECTRICAL CONNECTOR TO DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS ARE PRESENT

Next: p384, !f385

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p504, !f485

INSPECTION BURNER ASSEMBLY

REMOVE COMBUSTION BLOCK FROM BOILER
REMOVE LEFT-HAND SIDE CASE IF REQUIRED

Next: p549, !f550

TEST MODE ACTIVATION

Next: !p556, !f557

VOLTAGE DIVERTER VALVE AT PCB

{GAINPCBACS}
ENSURE NO DEMANDS ARE PRESENT

Next: p573, f574

VOLTAGE DIVERTER VALVE AT PCB - DIVERTER DISCONNECTED

REMOVE ELECTRICAL CONNECTOR TO DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS ARE PRESENT

Next: p575, !f576
Next: p588, !f590

RESISTANCE THERMISTOR FLOW AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: p736, f737

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: !p740, !f741

RESISTANCE THERMISTOR RETURN AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: p748, f749

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p750, !f751

RESET APPLIANCE - FAULT CODE 83

ENSURE NO DEMANDS ARE PRESENT

Next: p785, f2197

INSPECTION FILTER HEATING

ISOLATED COLD WATER

Next: !p803, !f804

VOLTAGE SENSOR SYSTEM PRESSURE - RETURN

{GAINPCBACS}

Next: p932, f933

VOLTAGE FLOW SENSOR - SEND

Next: p95, f2248

ADJUST PRIMARY SYSTEM PRESSURE - FAULT CODE F22

{GAINPCBACS}
LOCATE PRIMARY SYSTEM FILLING LOOP

Next: p949, f950

VOLTAGE FAN 22 VDC AT PCB

REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY, LEAVE IN A SAFE LOCATION

Next: p106, !f107

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p104, !f105

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: !p108, !f109

OBSERVATION SYSTEM PRESSURE

Next: p1062, f1975

OBSERVATION PUMP RUNS

Next: p1097, f2389

PUMP LIMPET TEST

Next: p1077, !f1078

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

ENSURE DHW FLOW RATE

Next: p1130, f1135

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p1092, !f1093

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1111, !f1125

TEMPERATURE FLOW - FROST PROTECTION

REMOVE LEFT HAND SID

Next: p12, !f13

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: p1071, !f1126

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: !p1128, !f1129

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: p1137, !f1138

INSPECTION FILTER HEATING

ISOLATED COLD WATER

Next: !p1139, !f1140

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1150, !f1151

OBSERVATION FAN RUNS - FAULT CODE F32

Next: !p1358, ?1340, ?1342

RESISTANCE LINK UNDER FLOOR HEATING CONNECTOR

{GAINPCBACS}
REMOVE UNDER FLOOR HEATING SENSOR CONNECTOR FROM X18 ON THE PCB

Next: p1183, !f1184

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1189, !f1190

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1191, !f1188

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1195, !f1196

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1197, !f1198

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p24, !f15

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p1204, !f1205

OBSERVATION SYSTEM PRESSURE

Next: p1240, f1959

OBSERVATION PUMP RUNS

Next: p1286, f2378

PUMP LIMPET TEST

Next: p1287, !f1322

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

ENSURE DHW FLOW RATE

Next: p1289, f1313

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

ATTACH TEMPERATURE C

Next: p1323, !f1319

RUN BOILER TO MAX TEMP - FAULT CODE F20

REMOVE LEFT HAND SID

Next: !p1299, ?1301, ?1303

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1305, !f1306

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p1309, !f1310

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p1307, !f1308

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p1311, !f1312

INSPECTION FILTER HEATING

ISOLATED COLD WATER

Next: !p1318, !f1320

OBSERVATION PUMP OVERRUN TIME

Next: p1297, !f1338

VOLTAGE FAN CONTROL PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY, LEAVE IN A SAFE LOCATION

Next: p1345, !f1355

VOLTAGE FAN 22 VDC AT PCB

REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY, LEAVE IN A SAFE LOCATION

Next: p1351, !f1352

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: !p1353, !f1354

DISCONNECT EBUS CONTROLS

REMOVE CONNECTOR X17 FROM THE PCB

Next: !p1366, !f1367

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1385, !f1386

FACTORY RESET - PCB MAIN

FACTORY RESET PRO

Next: !p1427, !f1428

INSPECTION RESTRICTOR FLOW (DHW)

ISOLATED COLD WATER

Next: !p1591, !f1592

VOLTAGE MAINS POWER INPUT AT PCB

{GAINPCBACS}

Next: p2065, f1603

DISCONNECT WATER PRESSURE SENSOR CONNECTOR

REMOVE WATER PRESSURE SENSOR CONNECTOR AND MAKE SAFE

Next: p1608, !f1609

DISCONNECT FAN CONNECTOR

REMOVE ELECTRICAL CONNECTOR TO FAN ASSEMBLY AND MAKE SAFE

Next: p1610, !f1611

VOLTAGE DISPLAY AT INTERFACE PCB

GAIN ACCESS TO INTERFACE PCB (USE INSULATION MAT AS REQUIRED)

Next: !p2096, !f2097

FAULT CODES

Next: !p1633, !f1634

BYPASS EXTERNAL CONTROLS - 24V

DISCONNECT 24V EXTER

Next: !p1847, f1848

DISCONNECT INTERNAL PROGRAMMER

GAIN ACCESS TO UPPER

Next: !p1851, !f1852

DISCONNECT EBUS CONTROLS - CH DEMAND

DISCONNECT EBUS WIRING CONNECTIONS TO CONNECTOR X17 AND MAKE SAFE

Next: !p1855, !f1856

BYPASS EXTERNAL CONTROLS - 240V

DISCONNECT 240V EXTE

Next: !p1859, f1860

DISCONNECT INTERNAL PROGRAMMER

GAIN ACCESS TO UPPER

Next: !p1863, !f1864

OBSERVATION EXTERNAL CONTROLS FITTED - SELF TEST

{GAINPCBACS}

Next: p1876, f1884

DISCONNECT EXTERNAL CONTROLS

REMOVE ALL EXTERNAL

Next: !p1877, f1878

DISCONNECT EXTERNAL CONTROLS

REMOVE ALL EXTERNAL

Next: !p1882, !f1883

SYSTEM PRESSURE SET CORRECTLY

THE SYSTEM PRESSURE

Next: !p1949, !f1950

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1954, ?1955, ?1957

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1961, ?1962, ?1964

INSPECTION FILLING LOOP

ISOLATE COLD FEED AS REQUIRED

Next: p1968, !f1974

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1969, ?1970, ?1972

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1977, ?1978, ?1980

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1985, ?1986, ?1988

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p1993, ?1994, ?1996

OBSERVATION SYSTEM PRESSURE

Next: p2138, f2000

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p2003, ?2005, ?2007

PUMP LIMPET TEST

Next: p2010, !f2011

INSPECTION AIR BOX

REMOVE AIR BOX FROM GAS VALVE

Next: p2012, !f2013

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2016, !f2017

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: p2018, !f2019

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

ENSURE DHW FLOW RATE

Next: p2262, f2021

OBSERVATION DSN NUMBER - DHW

PARAMETER DSN NUM

Next: !p2026, f2027

INSPECTION FILTER HEATING

ISOLATED COLD WATER

Next: !p2024, !f2025

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2036, !f2037

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p2038, !f2039

OBSERVATION SYSTEM PRESSURE

Next: p2041, f2056

PUMP LIMPET TEST

Next: p2042, !f2043

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

ENSURE DHW FLOW RATE

Next: p2046, f2047

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2052, !f2053

INSPECTION FILTER HEATING

ISOLATED COLD WATER

Next: !p2050, !f2051

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p2054, !f2055

INSPECTION SENSOR SYSTEM PRESSURE AND MANIFOLD

DRAIN PRIMARY SYSTEM

Next: !p2059, ?2061, ?2063

RESISTANCE FUSE PCB

REMOVE FUSE FROM PCB

Next: p1602, f2091

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2106, !f2107

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p2108, !f2109

RESET OPTIONS

Next: !p2112, !f2113

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: !p2123, !f2124

INSPECTION CONDENSATE PIPE

Next: p2127, !f2137

VOLTAGE RECTIFICATION AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND MAKE SAFE
ENSURE NO DEMANDS

Next: p2128, !f2129

RESISTANCE HARNESS SPARK GENERATOR

REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB

Next: !p2134, !f2135

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2009, !f2162

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p2179, !f2195

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: p788, !f2196

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p2200, !f2201

OBSERVATION GAS VALVE CLOSURE

Next: !p2232, !f2233

OBSERVATION PCB CONNECTIONS

Next: p2240, !f2241

OBSERVATION DSN NUMBER

PARAMETER DSN NUM

Next: p2242, f2243

FACTORY RESET - PCB MAIN

FACTORY RESET PRO

Next: !p2246, !f2247

OBSERVATION PUMP RUNS

Next: p2252, f2416

PUMP LIMPET TEST

Next: p2258, !f2259

DHW OPERATION - FAULT CODE

Next: !p2260, !f2261

GAS RATE

Next: p2020, ?2270, ?2272

OBSERVATION DSN NUMBER - DHW

PARAMETER DSN NUM

Next: p2284, f2281

INSPECTION FLUE ASSEMBLY

Next: p2275, !f2276

INSPECTION BURNER ASSEMBLY

REMOVE COMBUSTION BLOCK FROM BOILER
REMOVE LEFT-HAND SIDE CASE IF REQUIRED

Next: p2277, !f2278

INSPECTION FLUEWAYS HEAT EXCHANGER

Next: !p2279, !f2280

INSPECTION FLUE ASSEMBLY

Next: p2285, !f2286

INSPECTION BURNER ASSEMBLY

REMOVE COMBUSTION BLOCK FROM BOILER
REMOVE LEFT-HAND SIDE CASE IF REQUIRED

Next: p2287, !f2288

INSPECTION FLUEWAYS HEAT EXCHANGER

Next: !p2289, !f2290

INSPECTION ELECTRODE IGNITION

REMOVE IGNITION ELECTRODE

Next: p2292, !f2293

INSPECTION FLUE ASSEMBLY

Next: p2294, !f2295

INSPECTION BURNER ASSEMBLY

REMOVE COMBUSTION BLOCK FROM BOILER
REMOVE LEFT-HAND SIDE CASE IF REQUIRED

Next: p2296, !f2297

INSPECTION FLUEWAYS HEAT EXCHANGER

Next: !p2298, !f2299

OBSERVATION DS NUMBER RESET

SOMETIMES THE SOFTWA

Next: p1425, !f2304

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: p2306, !f2307

VOLTAGE FAN HALL SENSOR AT PCB

{GAINPCBACS}

Next: !p2308, !f2309

RESISTANCE HARNESS FAN

REMOVE ELECTRICAL CONNECTORS X20 FROM THE PCB AND TO THE FAN ASSEMBLY

Next: p2311, !f2312

VOLTAGE FAN HALL SENSOR AT PCB

{GAINPCBACS}

Next: !p2313, !f2314

INSPECTION CONDENSATE PIPE

Next: p235, !f270

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p295, !f243

RESISTANCE PUMP HARNESS ERP

REMOVE X14 PUMP CONNECTOR FROM THE PCB
DISCONNECT PLUG FROM THE PUMP

Next: p2522, !f2547

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2372, !f2373

OBSERVATION SPARKING HEARD

REMOVE IGNITION LEAD FROM SPARK GENERATOR AND MAKE SAFE

Next: !p240, f2114

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2433, !f2434

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2437, !f2438

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p30, !f26

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2459, !f2446

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p2441, !f2447

VOLTAGE GAS VALVE AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE AND MAKE SAFE

Next: p244, f245

RESISTANCE GAS VALVE AND HARNESS

{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB

Next: p2291, f251

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2523, !f2524

RESISTANCE PUMP AND HARNESS ERP

{GAINPCBACS}
REMOVE X14 PUMP CONNECTOR FROM THE PCB

Next: !p2541, !f2542

RESISTANCE PUMP HARNESS ERP

REMOVE X14 PUMP CONNECTOR FROM THE PCB
DISCONNECT PLUG FROM THE PUMP

Next: p2549, !f2550

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2551, !f2552

RESISTANCE PUMP HARNESS ERP

REMOVE X14 PUMP CONNECTOR FROM THE PCB
DISCONNECT PLUG FROM THE PUMP

Next: p2554, !f2555

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2556, !f2557

RESISTANCE PUMP HARNESS ERP

REMOVE X14 PUMP CONNECTOR FROM THE PCB
DISCONNECT PLUG FROM THE PUMP

Next: p2559, !f2560

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2561, !f2562

RESISTANCE PUMP HARNESS ERP

REMOVE X14 PUMP CONNECTOR FROM THE PCB
DISCONNECT PLUG FROM THE PUMP

Next: p2564, !f2565

VOLTAGE PUMP AT PCB ERP

{GAINPCBACS}

Next: !p2566, !f2567

INSPECTION CONDENSATE PIPE

Next: p284, !f281

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p282, !f283

INSPECTION FLUE ASSEMBLY

Next: p289, !f290

INSPECTION AIR BOX

REMOVE AIR BOX FROM GAS VALVE

Next: p280, !f288

INSPECTION BURNER ASSEMBLY

REMOVE COMBUSTION BLOCK FROM BOILER
REMOVE LEFT-HAND SIDE CASE IF REQUIRED

Next: p291, !f292

INSPECTION AIR BOX

REMOVE AIR BOX FROM GAS VALVE

Next: p242, !f321

VOLTAGE DIVERTER VALVE - POWER UP

REMOVE ELECTRICAL CONNECTOR TO DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS ARE PRESENT

Next: !p375, !f376

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR X2 FROM THE PCB AND
ELECTRICAL CONNECTOR TO THE DIVERTER VALVE

Next: !p386, !f387

INSPECTION SENSOR FLOW - DHW

ISOLATE COLD FEED TO BOILER
DRAIN DHW CIRCUIT
REMOVE DHW FLOW SENSOR

Next: p1590, ?51, ?53

INSPECTION FLUE ASSEMBLY

Next: p486, !f487

INSPECTION COMBUSTION SEALS

Next: p488, !f489

ADJUSTMENT AIR/GAS RATIO

CONNECT FGA TO THE COMBUSTION TEST POINT ON THE BOILER
ENSURE CH SYSTEM IS COOL

Next: p490, f548

AIR/GAS RATIO - ADJUSTED CORRECTLY

THE COMBUSTION READI

Next: !p502, !f1686

INSPECTION AIR BOX

REMOVE AIR BOX FROM GAS VALVE

Next: p526, !f524

INSPECTION CONDENSATE PIPE

Next: p484, !f546

INSPECTION EXPANSION VESSEL PRESSURE

DISCHARGE PRIMARY SYSTEM WATER

Next: !p581, !f582

PUMP LIMPET TEST

Next: p568, !f569

TEMPERATURE DIFFERENTIAL - INTERNAL BYPASS

ENSURE RADIATORS ARE

Next: !p593, !f594

VOLTAGE DIVERTER VALVE - POWER UP

REMOVE ELECTRICAL CONNECTOR TO DIVERTER VALVE AND MAKE SAFE
ENSURE NO DEMANDS ARE PRESENT

Next: !p579, !f580

RESISTANCE HARNESS DIVERTER VALVE

REMOVE CONNECTOR X2 FROM THE PCB AND
ELECTRICAL CONNECTOR TO THE DIVERTER VALVE

Next: !p577, !f578

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p599, !f586

PARAMETER SET CORRECTLY - RADIATOR TEMPERATURE LOW

THE MAXIMUM HEATING

Next: !p591, !f592

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: !p600, !f601

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p738, !f739

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p752, !f753

OBSERVATION SYSTEM PRESSURE

Next: p786, f1991

OBSERVATION PUMP RUNS

Next: p790, f2403

PUMP LIMPET TEST

Next: p797, !f1377

CH OPERATION - FAULT CODE F83

Next: p799, !f800

DHW OPERATION - FAULT CODE F83

Next: !p807, f802

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE RED LEADS TO FLOW THERMISTOR

Next: p842, !f843

RESISTANCE THERMISTOR RETURN

REMOVE LEFT HAND SIDE PANEL
REMOVE BLUE LEADS TO RETURN THERMISTOR

Next: p846, !f845

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: p2251, !f848

VOLTAGE FLOW SENSOR DHW - RETURN

{GAINPCBACS}
ENSURE A FLOW RATE OF 3 LITRES PER MINUTE

Next: p2103, f94

ADJUST PRIMARY SYSTEM PRESSURE

LOCATE PRIMARY SYSTEM FILLING LOOP

Next: p938, f1983

RESISTANCE HARNESS SENSOR SYSTEM PRESSURE

REMOVE CONNECTOR X2 FROM THE PCB
REMOVE CONNECTOR TO SYSTEM PRESSURE SENSOR

Next: !p936, !f937

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p945, !f946

RESET APPLIANCE - FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1059, !f952

RESISTANCE HARNESS FLOW SENSOR

REMOVE ELECTRICAL CONNECTORS X2 FROM THE PCB AND
TO THE DHW FLOW SENSOR

Next: !p97, !f98

VOLTAGE FAN CONTROL PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM FAN ASSEMBLY, LEAVE IN A SAFE LOCATION

Next: p100, f101