Set Appliance State:

Gas Off
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Air heater switch set to constant
Thermistor-stat set to maximum
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the ignition sequence to commence and burner ignite.
After approximately 90 seconds measure the voltage across connections 1 (pink lead) and connection 2 (red lead) on the control module.
Voltage should increase from approximately 90 volts to approximately 210 volts with fan running at full speed.