FAULT CODES 1
None
| Fault code | Cause | Action (click on appropriate action) |
| 10 | Short circuit, outside temperature sensor | Check the outside temperature sensor and lead |
| 18 | Lead break, outside temperature sensor | Check the outside temperature sensor and lead |
| 30 | Short circuit, boiler water temperature sensor | Check boiler water temperature sensor |
| 38 | Lead break, boiler water temperature sensor | Check boiler water temperature sensor |
| 51 | Short circuit, outlet temperature sensor | Check sensor |
| 52 | Short circuit, flow sensor | Check connections, lead & sensor |
| 59 | Lead break, outlet temperature sensor | Check sensor |
| 5 A | Lead break, flow sensor | Check connections, lead & sensor |
| A9 | Communication error, Open Therm device | Not applicable for this boiler |
| b0 | Short circuit, flue gas temperature sensor | Check sensor |
| b8 | Lead break, flue gas temperature sensor | Check sensor |
| E3 | Fault in safety chain | Check the temperature limiter and connecting cables |
| E5 | Internal fault | Check the ionisation electrode and connecting cables |