Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Remove the control box from the gas valve and position it as shown - if not possible use an insulation mat and position it elsewhere - DO NOT hold the control box
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance as necessary.
Test 1:
Allow the fan to run and ignition sequence to commence.
During the sparking stage of the ignition cycle measure the AC voltage between pins 1 and 2 on the ignition control box gas valve connector - expect mains voltage.
Test 2:
Allow the fan to run and ignition sequence to commence.
During the sparking stage of the ignition cycle measure the AC voltage between pins 2 and 3 on the ignition control box gas valve connector - expect mains voltage.
Note:
Appliance may go to lockout during this test, reset as necessary to confirm result.
Are the voltages measured as expected?