Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect spade connectors from modulating solenoid
Disconnect plug from safety solenoids
Disconnect plug from safety solenoids
Measurement:
Test 1:
Measure the resistance across the modulating
solenoid coil terminals.
Resistance should be approximately 125 Ohms.
Test 2:
Measure the resistance across the safety solenoid terminals.
Resistance should be approximately 890 Ohms.
Measure the resistance across the modulating
solenoid coil terminals.
Resistance should be approximately 125 Ohms.
Test 2:
Measure the resistance across the safety solenoid terminals.
Resistance should be approximately 890 Ohms.

Isolate as per TOPs P4
and refit as necessary