Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Reconnect 4 wire connector at fan if you have not already done so
NO demands
NO demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the White wire at the fan DC connector (4 wire) and a suitable earth.
As the power is turned on to the appliance the voltage should be approximately 16 VDC or greater.
Voltage will be present for approximately 8 seconds and then the voltage will drop to approximately 1.3 VDC, repeat test as necessary.
As the power is turned on to the appliance the voltage should be approximately 16 VDC or greater.
Voltage will be present for approximately 8 seconds and then the voltage will drop to approximately 1.3 VDC, repeat test as necessary.

Isolate as per TOPs P4
and refit as necessary