Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Boiler in CH and DHW mode, NO demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
On initial start up the display should illuminate, if a fault code is displayed choose that option below.
If the appliance is not in a fault code the fan should run for approximately 8 seconds then stop.
The boiler should then enter standby, standby is indicated by the display showing the flow temperature, neither the tap or radiator symbols flashing, and the pump should not be running.
Does the appliance behave as described above?
Note:
If the appliance is showing a fault code the fan may still run.
If the appliance is not in a fault code the fan should run for approximately 8 seconds then stop.
The boiler should then enter standby, standby is indicated by the display showing the flow temperature, neither the tap or radiator symbols flashing, and the pump should not be running.
Does the appliance behave as described above?
Note:
If the appliance is showing a fault code the fan may still run.